ONSEMI AMIS49587C5871RG

AMIS-- 49587
Product Preview
Power Line Carrier Modem
ON Semiconductor’s AMIS--49587 is an IEC 61334--5--1
compliant power line carrier modem using spread--FSK (S--FSK)
modulation for robust low data rate communication over power lines.
AMIS--49587 is built around an ARM 7TDMI processor core, and
includes the MAC layer. With this robust modulation technique,
signals on the power lines can pass long distances. The half--duplex
operation is automatically synchronized to the mains, and can be up to
2400 bits/sec.
The product configuration is done via its serial interface, which
allows the user to concentrate on the development of the application.
The AMIS--49587 is implemented in ON Semiconductor mixed
signal technology, combining both analog circuitry and digital
functionality on the same IC.
http://onsemi.com
281
1
PLCC 28 Lead
CASE 776AA
52
QFN52 8x8, 0.5P
CASE 485M
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
Power Line Carrier Modem for 50 and 60 Hz Mains
Fully compliant to IEC 61334--5--1 and CENELEC EN 50065--1
Complete Handling of Protocol Layers Physical to MAC
Programmable Carrier Frequencies from 9 to 95 kHz in 10 Hz Steps
Half Duplex
Data Rate Selectable:
300 – 600 – 1200 – 2400 baud (@ 50 Hz)
360 – 720 – 1440 – 2880 baud (@ 60 Hz)
Synchronization on Mains
Repetition Algorithm Boost the Robustness of Communication
SCI Port to Application Microcontroller
SCI Baudrate Selectable: 4.8 – 9.6 – 19.2 – 34.4 kb
Power Supply 3.3 V
Ambient Temperature Range: --40°C to +80°C
These Devices are Pb--Free and are RoHS Compliant*
MARKING DIAGRAMS
XXXXYZZ
AMIS49587
C587--NAF
ON
ARM
XXXXYZZ
AMIS49587
C587--NAF
ARM: Automated Remote Meter Reading (Télérelevé)
Remote Security Control
Streetlight Control
Transmission of Alerts (Fire, Gas Leak, Water Leak)
e3
52
1
Typical Applications
•
•
•
•
ARM
ON
XXXX
Y
ZZ
e3
= Date Code
= Plant Identifier
= Traceability Code
ORDERING INFORMATION
See detailed ordering and shipping information in the
package dimensions section on page 3 of this data sheet.
*For additional information on our Pb--Free strategy and soldering details, please
download the ON Semiconductor Soldering and Mounting Techniques
Reference Manual, SOLDERRM/D.
This document contains information on a product under development. ON
Semiconductor reserves the right to change or discontinue this product without notice.
© Semiconductor Components Industries, LLC, 2009
December, 2009 -- Rev. P2
1
Publication Order Number:
AMIS--49587/D
AMIS--49587
1 APPLICATION
1.1 APPLICATION EXAMPLE
3V3_D
VDD
VDDA
3V3_A
TX_OUT
T_REQ
NCS5650
TXD
TX _ENB
RXD
BR0
RX_OUT
Application
m Controller
BR1
RX_IN
RESB
AMIS--49587
1:2
REF_OUT
MAINS
3V3_A
ALC_IN
Meter
Interface
VSS
VSSA
XTAL_OUT
XTAL_IN
M50HzIN
Figure 1. Typical Application for the AMIS--49587 S--FSK Modem
http://onsemi.com
2
AMIS--49587
Table 1. ORDERING INFORMATION
Temperature Range
Package
Shipping†
AMIS49587C5871G
--40°C -- +80°C
PLCC--28
(Pb--Free)
Tube
AMIS49587C5871RG
--40°C -- +80°C
PLCC--28
(Pb--Free)
Tape & Reel
AMIS49587C5872G
--40°C -- +80°C
QFN--52
(Pb--Free)
Tube
AMIS49587C5872RG
--40°C -- +80°C
QFN--52
(Pb--Free)
Tape & Reel
Part No.
†For information on tape and reel specifications, including part orientation and tape sizes, please refer to our Tape and Reel Packaging
Specification Brochure, BRD8011/D.
Table of Contents
Detailed Hardware Description . . . . . . . . . . . . . . . . . . . . . . . . 18
Clock and Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Transmitter Path Description (S-FSK Modulator) . . . . 22
Receiver Path Description . . . . . . . . . . . . . . . . . . . . . . . 24
Communication Controller . . . . . . . . . . . . . . . . . . . . . . . 26
Detailed Software Description . . . . . . . . . . . . . . . . . . . . . . . . . 33
Configure the AMIS--49587 . . . . . . . . . . . . . . . . . . . . . . . . 33
Obtaining Status Messages . . . . . . . . . . . . . . . . . . . . . . 33
Configuration of the AMIS-49587 . . . . . . . . . . . . . . . . . 35
Send and Receive Network Data with the AMIS-49587
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Retrieve Statistical Data from the AMIS-49587 . . . . . 52
Package Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Application Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Normal Operating Conditions . . . . . . . . . . . . . . . . . . . . . . 4
Pin Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
PLCC Packaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
QFN Packaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Detailed Pin Description . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
DC and AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . 11
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
http://onsemi.com
3
AMIS--49587
2 ABSOLUTE MAXIMUM RATINGS2.1
Stresses above those listed in this clause may cause permanent device failure. Exposure to absolute maximum ratings for
extended periods may affect device reliability.
2.1.1 Power Supply Pins VDD, VDDA, VSS, VSSA
Table 2. ABSOLUTE MAXIMUM RATINGS SUPPLY
Rating
Absolute maximum digital power supply
Absolute maximum analog power supply
Symbol
Min
Max
Unit
VDD_ABSM
VSS --0.3
3.9
V
VDDA_ABSM
VSSA --0.3
3.9
V
Absolute maximum difference between digital and analog power supply
VDD --VDDA_ABSM
--0.3
0.3
V
Absolute maximum difference between digital and analog ground
VSS --VSSA_ABSM
--0.3
0.3
V
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
2.1.2 Non 5V Safe Pins: TX_OUT, ALC_IN, RX_IN, RX_OUT, REF_OUT, M50HZ_IN, XIN, XOUT, TDO, TDI, TCK, TMS,
TRSTB, TEST
Table 3. ABSOLUTE MAXIMUM RATINGS NON 5V SAFE PINS
Rating
Absolute maximum input for normal digital inputs and analog inputs
Absolute maximum voltage at any output pin
Symbol
Min
Max
Unit
VIN_ABSM
VSS* --0.3
VDD*+0.3
V
VOUT_ABSM
VSS* --0.3
VDD*+0.3
V
2.1.3 5V Safe Pins: TX_ENB, TXD, RXD, BR0, BR1, RESB, RX_DATA, TREQ, CRC, TX_DATA/PRE_SLOT
Table 4. ABSOLUTE MAXIMUM RATINGS 5V SAFE PINS
Rating
Symbol
Min
Max
Unit
Absolute maximum input for digital 5 V safe inputs
V5VS_ABSM
VSS --0.3
6.0
V
Absolute maximum voltage at 5 V safe output pin
VOUT5V_ABSM
VSS --0.3
3.9
V
2.2 Normal Operating Conditions
Operating ranges define the limits for functional operation and parametric characteristics of the device as described in the
Receiver Block Diagram Section and for the reliability specifications as listed in the Local Transfer and Configuration
Commands (LTC) Section. Functionality outside these limits is not implied.
Total cumulative dwell time outside the normal power supply voltage range or the ambient temperature under bias, must
be less than 0.1% of the useful life as defined in the Local Transfer and Configuration Commands (LTC) Section.
Table 5. OPERATING RANGES
Rating
Power Supply Voltage Range
Ambient Temperature
http://onsemi.com
4
Symbol
Min
Max
Unit
VDD
3.0
3.6
V
TA
--25
70
°C
AMIS--49587
2
1
ALC_IN
VSSA
3
TX_OUT
RX_OUT
4
VDDA
REF_OUT
3.1 PLCC Packaging
RX_IN
3 PIN DESCRIPTION
28 27 26
M50Hz_IN
5
25 TX _ENB
RX_DATA
6
24 TEST
TDO
7
23 RESB
TDI
8
TCK
9
21 BR0
TMS 10
20 BR1
22 CRC
AMIS--49587
TRSTB 11
19 T_REQ
RXD
TXD
VDD
VSS
XOUT
XIN
TX_DATA/
PRE_SLOT
12 13 14 15 16 17 18
Figure 2. Pinout
Table 6. AMIS--49587 PLCC PIN FUNCTION DESCRIPTION
Pin No.
Pin Name
1
VSSA
2
RX_OUT
3
RX_IN
4
P:
A:
D:
I/O
Type
Description
P
Analog ground
Out
A
Output of receiver low noise operational amplifier
In
A
Positive input of receiver low noise operational amplifier
REF_OUT
Out
A
Reference output for stabilization
5
M50HZ_IN
In
A
50/60 Hz input for mains zero cross detection
6
RX_DATA
Out
D, 5V Safe
Data reception indication (open drain output)
7
TDO
Out
D
Test data output
8
TDI
In
D
Test data input (internal pulldown)
9
TCK
In
D
Test clock (internal pulldown)
10
TMS
In
D
Test mode select (internal pulldown)
11
TRSTB
In
D
Test reset bar (internal pulldown, active low)
12
TX_DATA/
PRE_SLOT
Out
D, 5V Safe
Data output corresponding to transmitted data or PRE_SLOT signal
(open drain output)
13
XIN
In
A
Xtal input (can be driven by an internal clock)
14
XOUT
Out
A
Xtal output (output floating when XIN driven by external clock)
15
VSS
P
Digital ground
16
VDD
P
3.3 V digital supply
17
TXD
Out
D, 5V Safe
SCI transmit output (open drain)
18
RXD
In
D, 5V Safe
SCI receive input (Schmitt trigger input)
19
T_REQ
In
D, 5V Safe
Transmit request input
20
BR1
In
D, 5V Safe
SCI baud rate selection
21
BR0
In
D, 5V Safe
SCI baud rate selection
22
CRC
Out
D, 5V Safe
Correct frame CRC indication (open drain output)
23
RESB
In
D, 5V Safe
Master reset bar (Schmitt trigger input, active low)
24
TEST
In
D
25
TX_ENB
Out
D, 5V Safe
26
TX_OUT
Out
A
Transmitter output
27
ALC_IN
In
A
Automatic level control input
28
VDDA
P
3.3 V analog supply
Power pin
Analog pin
Digital pin
Test enable (internal pulldown)
TX enable bar (open drain)
5V Safe:
Out:
In:
In/Out:
IO that support the presence of 5V on bus line
Output signal
Input signal
Bi--directional pin
http://onsemi.com
5
AMIS--49587
3.2 QFN Packaging
NC
NC
TX_OUT
ALC_IN
NC
NC
40
41
42
43
44
45
48
VDDA
VSSA
RX_OUT
49
50
1
2
3
4
5
6
7
8
9
10
11
12
13
46
47
RX_IN
NC
52
51
REF_OUT
NC
M50Hz_IN
NC
NC
NC
NC
RX _DATA
TDO
TDI
TCK
TMS
TRST
NC
NC
39
38
37
36
35
34
33
32
31
30
29
28
27
AMIS--49587
NC
NC
TX_EN
TEST
RES
NC
CRC
BR0
BR1
NC
T_REQ
NC
NC
26
25
24
23
22
21
20
19
NC
NC
RXD
NC
TXD
VDD
VSS
NC
XOUT
TX_DATA /
NC PRE_SLOT
XIN
NC
18
15
17
16
14
Figure 3. QFN Pin--out of AMIS--49587 (Top view)
Table 7. AMIS--49587 QFN PIN FUNCTION DESCRIPTION
Pin
No.
Pin Name
I/O
Type
1
M50HZ_IN
In
A
50/60Hz input for mains zero cross detection
6
RX_DATA
Out
D, 5V Safe
Data reception indication (open drain output)
7
TDO
Out
D
Test data output
8
TDI
In
D
Test data input (internal pull down)
9
TCK
In
D
Test clock (internal pull down)
10
TMS
In
D
Test mode select (internal pull down)
11
TRSTB
In
D
Test reset bar (internal pull down, active low)
16
TX_DATA/PRE_SLOT
Out
D, 5V Safe
17
XIN
In
A
Xtal input (can be driven by an internal clock)
18
XOUT
Out
A
Xtal output (output floating when XIN driven by external clock)
20
VSS
P
Digital ground
21
VDD
P
3.3 V digital supply
22
TXD
Out
D, 5V Safe
SCI transmit output (open drain)
24
RXD
In
D, 5V Safe
SCI receive input (Schmitt trigger input)
29
T_REQ
In
D, 5V Safe
Transmit Request input
31
BR1
In
D, 5V Safe
SCI baud rate selection
32
BR0
In
D, 5V Safe
SCI baud rate selection
33
CRC
Out
D, 5V Safe
Correct frame CRC indication (open drain output)
35
RESB
In
D, 5V Safe
Master reset bar (Schmitt trigger input, active low)
TEST
In
36
P:
A:
D:
Power pin
Analog pin
Digital pin
D
Description
Data output corresponding to transmitted data or PRE_SLOT signal
(open drain)
Test enable (internal pull down)
5V Safe: IO that support the presence of 5 V on bus line
Out:
Output signal
In:
Input signal
http://onsemi.com
6
AMIS--49587
Table 7. AMIS--49587 QFN PIN FUNCTION DESCRIPTION
Pin
No.
Pin Name
I/O
Type
37
TX_ENB
Out
D, 5V Safe
42
TX_OUT
Out
A
Transmitter output
43
ALC_IN
In
A
Automatic level control input
46
VDDA
P
3.3 V analog supply
47
VSSA
P
Analog ground
48
RX_OUT
Out
A
Output of receiver low noise operational amplifier
49
RX_IN
In
A
Positive input of receiver low noise operational amplifier
51
REF_OUT
Out
A
Reference output for stabilization
2, 3, ..
50, 52
NC
P:
A:
D:
Power pin
Analog pin
Digital pin
Description
TX enable bar (open drain)
Pins 2, 3, 4, 5, 12, 13, 14, 15, 19,23, 25, 26, 27, 28, 30, 34, 38, 39, 40,
42, 44, 45, 50, 52 are not connected. These pins need to be left open or
connected to the GND plane
5V Safe: IO that support the presence of 5 V on bus line
Out:
Output signal
In:
Input signal
3.3 Detailed Pin Description
VDDA
VDDA is the positive analog supply pin. Nominal voltage is 3.3 V. A ceramic decoupling capacitor CDA = 100 nF ±10% must
be placed between this pin and the VSSA. Connection path of this capacitance to the VSSA on the PCB should be kept as short
as possible in order to minimize the serial resistance.
REF_OUT
REF_OUT is the analog output pin which provides the voltage reference used by the A/D converter. This pin must be
decoupled to the analog ground by a 1 mF ±10 percent ceramic capacitance CDREF. The connection path of this capacitor to
the VSSA on the PCB should be kept as short as possible in order to minimize the serial resistance.
VSSA
VSSA is the analog ground supply pin.
VDD
VDD is the 3.3 V digital supply pin. A ceramic decoupling capacitor CDD = 100 nF ±10% must be placed between this pin
and the VSS. Connection path of this capacitance to the VSS on the PCB should be kept as short as possible in order to minimize
the serial resistance.
VSS
VSS is the digital ground supply pin.
http://onsemi.com
7
AMIS--49587
GROUND
CDA
CDREF
3,3V SUPPLY
5
6
1 28 27 26
VSSA
2
VDDA
3
REF_OUT
4
25
24
22
9
21
10
20
11
19
VDD
23
8
VSS
7
12 13 14 15 16 17 18
CDD
Figure 4. Recommended Layout of the Placement of Decoupling Capacitors for PLCC--28
RX_OUT
RX_OUT is the output analog pin of the receiver low noise input op--amp. This op--amp is in a negative feedback
configuration.
RX_IN
RX_IN is the positive analog input pin of the receiver low noise input op--amp. Together with RX_OUT and REF_OUT, an
active high pass filter is realized. This filter removes the main frequency (50 or 60 Hz) from the received signal. The filter
characteristics are determined by external capacitors and resistors. A typical application schematic can be found in paragraph
50/60 Hz suppression filter.
M50Hz_IN
M50HZ_IN is the mains frequency analog input pin. The signal is used to detect the zero crossing of the 50 or 60 Hz sine wave.
This information is used, after filtering with the internal PLL, to synchronize frames with the mains frequency. In case of direct
connection to the mains it is advised to use a series resistor of 1 MΩ in combination with two external clamp diodes in order
to limit the current flowing through the internal protection diodes.
RX_DATA
RX_DATA is a 5 V compliant open drain output. An external pull--up resistor defines the logic high level as illustrated in
Figure 5. A typical value for the pull--up resistance “R” is 10 kΩ. The signal on this output depends on the status of the data
reception. If AMIS--49587 waits for configuration RX_DATA outputs a pulse train with a 10 Hz frequency. After
Synchronization Confirm Time out RX_DATA = 0. If AMIS--49587 is searching for synchronization RX_DATA = 1.
+5V
R
Output
VSSD
Figure 5. Representation of 5V Safe Output
http://onsemi.com
8
AMIS--49587
TDO, TDI, TCK, TMS, and TRSTB
All these pins are part of the JTAG bus interface. The JTAG interface is used during production test of the IC and will not be
described here. Input pins (TDI, TCK, TMS, and TRSTB) contain internal pull--down resistance. TDO is an output. When
not used, the JTAG interface pins may be left floating.
TX_DATA/PRE_SLOT
TX_DATA/PRE_SLOT is the output for either the transmitting data (TX_DATA) or a synchronization signal with the
time--slots (PRE_SLOT). More information can be found in paragraph Local Port.
XIN
XIN is the analog input pin of the oscillator. It is connected to the interval oscillator inverter gain stage. The clock signal can
be created either internally with the external crystal and two capacitors or by connecting an external clock signal to XIN. For
the internal generation case, the two external capacitors and crystal are placed as shown in Figure 6. For the external clock
connection, the signal is connected to XIN and XOUT is left unused.
XTAL _IN
RX
XTAL_ OUT
24 MHz
CX
CX
V SSA
Figure 6. Placement of the Capacitors and Crystal with Clock Signal Generated Internally
The crystal is a classical parallel resonance crystal of 24 MHz. The values of the capacitors CX are given by the manufacturer
of the crystal. A typical value is 30 pF. The crystal has to fulfill impedance characteristics specified in the AMIS--49587 data
sheet. As an oscillator is sensitive and precise, it is advised to put the crystal as close as possible on the board and to ground
the case.
XOUT
XOUT is the analog output pin of the oscillator. When the clock signal is provided from an external generator, this output must
be floating. When working with a crystal, this pin cannot be used directly as clock output because no additional loading is
allowed on the pin (limited voltage swing).
TXD
TXD is the digital output of the asynchronous serial communication (SCI) unit. Only half--duplex transmission is supported.
It is used to realize the communication between the AMIS--49587 and the application microcontroller. The TXD is an open
drain IO (5 V safe). External pull--up resistances (typically 10 kΩ) are necessary to generate the 5 V level. See Figure 5 for
the circuit schematic.
RXD
This is the digital input of the asynchronous SCI unit.
Only half--duplex transmission is supported. This pin supports a 5 V level. It is used to realize the communication between
the AMIS--49587 and the application microcontroller. RXD is a 5 V safe input.
T_REQ
T_REQ is the transmission request input of the Serial Communication Interface. When pulled low its initiate a local
communication from the application micro controller to AMIS--49587. T_REQ is a 5 V safe input.
BR1, BR0
BR0 and BR1 are digital input pins. They are used to select the baud rate (bits/second) of the Serial Communication Interface
unit. The rate is defined according to Table 28: BR1, BR0 Baud Rates. The values are taken into account after a reset, hardware
or software. Modification of the baud rate during function is not possible. BR0 and BR1 are 5 V safe.
http://onsemi.com
9
AMIS--49587
CRC
CRC is a 5V compliant open drain output. An external pull--up resistor defines the logic high level as illustrated in Figure 5.
A typical value for this pull--up resistance “R” is 10 kΩ. The signal on this output depends on the cyclic redundancy code result
of the received frame. If the cyclic redundancy code is correct CRC = 1 during the pause between 2 time slots.
RESB
RESB is a digital input pin. It is used to perform a hardware reset of the AMIS--49587. This pin supports a 5 V voltage level.
The reset is active when the signal is low (0 V).
TEST
TEST is a digital input pin. It is used to enable the test mode of the chip. Normal mode is activated when TEST signal is low
(0 V). For normal operation, the TEST pin may be left unconnected. Due to the internal pulldown, the signal is maintained
to low (0 V). TEST pin is not 5 V safe.
TX_ENB
TX_ENB is a digital output pin. It is low when the transmitter is activated. The signal is available to turn on the line driver.
TX_ENB is a 5 V safe with open drain output, hence a pull--up resistance is necessary achieve the requested voltage level
associated with a logical one. See also Figure 5 for reference.
TX_OUT
TX_OUT is the analog output pin of the transmitter. The provided signal is the S--FSK modulated frames. A filtering operation
must be performed to reduce the second order harmonic distortion. For this purpose an active filter is realized. Figure 7 gives
the representation of this filter.
Transmitter (S--FSK Modulator)
FROM LINE
DRIVER
C4
ALC _IN
R3
ALC
control
C3
R2
TO TX POWER
OUTPUT STAGE
R1
C2
C1
TX_OUT
LP
Filter
ARM
Interface
&
Control
TX_EN
VSSA
Figure 7. TX_OUT Filter
ALC_IN
ALC_IN is the automatic level control analog input pin. The signal is used to adjust the level of the transmitted signal. The
signal level adaptation is based on the AC component. The DC level on the ALC_IN pin is fixed internally to 1.65 V.
Comparing the peak voltage of the AC signal with two internal thresholds does the adaptation of the gain. Low threshold is
fixed to 0.4 V. A value under this threshold will result in an increase of the gain. The high threshold is fixed to 0.6 V. A value
over this threshold will result in a decrease of the gain. A serial capacitance is used to block the DC components. The level
adaptation is performed during the transmission of the first two bits of a new frame. Eight successive adaptations are
performed.
http://onsemi.com
10
AMIS--49587
4 ELECTRICAL CHARACTERISTICS
4.1 DC AND AC CHARACTERISTICS
4.1.1 Oscillator: Pin XIN, XOUT
In production the actual oscillation of the oscillator and duty cycle will not be tested. The production test will be based on the
static parameters and the inversion from XIN to XOUT in order to guarantee the functionality of the oscillator.
Table 8. OSCILLATOR
Parameter
Test Conditions
Symbol
Min
Typ
Max
Unit
fCLK
--100 ppm
24
+100 ppm
MHz
60
%
Crystal frequency
(Note 1)
Duty cycle with quartz connected
(Note 1)
Start--up time
(Note 1)
Tstartup
50
ms
Maximum Capacitive load on XOUT
XIN used as clock input
CLXOUT
50
pF
Low input threshold voltage
XIN used as clock input
VILXOUT
High input threshold voltage
XIN used as clock input
VIHXOUT
0.7 VDD
V
Low output voltage
XIN used as clock input,
XOUT = 2 mA
VOLXOUT
0.3
V
High input voltage
XIN used as clock input
VOHXOUT
VDD --0.3
V
Max
Unit
20
mA
40
0.3 VDD
V
1. Guaranteed by design. Maximum allowed series loss resistance up to 80 Ω.
4.1.2 Zero Crossing Detector and 50/60 Hz PLL: Pin M50HZ_IN
Table 9. ZERO CROSSING DETECTOR AND 50/60 Hz PLL
Parameter
Test Conditions
Maximum peak input current
Symbol
Min
ImpM50HZIN
--20
Typ
Maximum average input current
During 1 ms
Mains voltage (ms) range
With protection resistor at
M50HZIN
Rising threshold level
(Note 2)
VIRM50HZIN
Falling threshold level
(Note 2)
VIFM50HZIN
0.9
V
Hysteresis
(Note 2)
VHY50HZIN
0.4
V
Lock range for 50 Hz (Note 3)
MAINS_FREQ = 0 (50 Hz)
Flock50Hz
45
55
Hz
Lock range for 60 Hz (Note 3)
MAINS_FREQ = 0 (60 Hz)
Flock60Hz
54
66
Hz
Lock time (Note 3)
MAINS_FREQ = 0 (50 Hz)
Tlock50Hz
15
s
Lock time (Note 3)
MAINS_FREQ = 0 (60 Hz)
Tlock60Hz
20
s
Frequency variation without going out of
lock (Note 3)
MAINS_FREQ = 0 (50 Hz)
DF60Hz
0.1
Hz/s
Frequency variation without going out of
lock (Note 3)
MAINS_FREQ = 0 (60 Hz)
DF50Hz
0.1
Hz/s
25
ms
Jitter of CHIP_CLK (Note 3)
ImavgM50HZIN
--2
2
mA
VMAINS
90
550
V
1.9
V
JitterCHIP_CLK
--25
2. Measured relative to VSS.
3. These parameters will not be measured in production since the performance is totally dependent of a digital circuit which will be guaranteed
by the digital test patterns.
http://onsemi.com
11
AMIS--49587
4.1.3 Transmitter External Parameters: Pin TX_OUT, ALC_IN, TX_ENB
To guarantee the transmitter external specifications the TX_CLK frequency must be 12 MHz ± 100 ppm.
Table 10. TRANSMITTER EXTERNAL PARAMETERS
Parameter
Test Conditions
Symbol
Min
0.85
0.76
Typ
Max
Unit
1.15
1.22
Vp
Maximum peak output level
fTX_OUT = 23.75 kHz
fTX_OUT = 95 kHz
Level control at max. output
VTX_OUT
Second order harmonic distortion
fTX_OUT = 95 kHz
Level control at max. output
HD2
--56
dB
Third order harmonic distortion
fTX_OUT = 95 kHz
Level control at max. output
HD3
--58
dB
Frequency accuracy of the
generated sine wave
(Notes 4 and 6)
DfTX_OUT
30
Hz
Capacitive output load at pin
TX_OUT
(Note 4)
CLTX_OUT
20
pF
Resistive output load at pin
TX_OUT
RLTX_OUT
5
TdTX_ENB
0.25
0.5
ms
Automatic level control attenuation
step
ALCstep
2.9
3.1
dB
Maximum attenuation
ALCrange
20.3
21.7
dB
Low threshold level on ALC_IN
VTLALC_IN
--0.46
--0.36
V
High threshold level on ALC_IN
VTHALC_IN
--0.68
--0.54
V
Input impedance of ALC_IN pin
RALC_IN
111
189
kΩ
PSRRTX_OUT
10 (Note 7)
35 (Note 8)
dB
Turn off delay of TX_ENB output
(Note 5)
Power supply rejection ration of the
transmitter section
kΩ
4.
5.
6.
7.
This parameter will not be tested in production.
This delay corresponds to the internal transmit path delay and will be defined during design.
Taking into account the resolution of the DDS and an accuracy of 100 ppm of the crystal.
A sinusoidal signal of 10 kHz and 100 mVpp is injected between VDDA and VSSA. The digital AD converter generates an idle pattern. The
signal level at TX_OUT is measured to determine the parameter.
8. A sinusoidal signal of 50 Hz and 100 mVpp is injected between VDDA and VSSA. The digital AD converter generates an idle pattern. The
signal level at TX_OUT is measured to determine the parameter.
The LPF filter + amplifier must have a frequency characteristic between the limits listed below. The absolute output level
depends on the operating condition. In production the measurement will be done for relative output levels where the 0 dB
reference value is measured at 50 kHz with a signal amplitude of 100 mV.
Table 11. TRANSMITTER FREQUENCY CHARACTERISTICS
Attenuation
Frequency (kHz)
Min
Max
Unit
10
--0.5
0.5
dB
95
--1.3
0.5
dB
130
--4.5
--2.0
dB
165
--3.0
dB
330
--18.0
dB
660
--36.0
dB
1000
--50
dB
2000
--50
dB
http://onsemi.com
12
AMIS--49587
4.1.4 Receiver External Parameters: Pin RX_IN, RX_OUT, REF_OUT
Table 12. RECEIVER EXTERNAL PARAMETERS: Pin RX_IN, RX_OUT, REF_OUT
Parameter
Test Conditions
Symbol
Min
Typ
Max
Unit
Input offset voltage 42 dB
AGC gain = 42 dB
VOFFS_RX_IN
5
mV
Input offset voltage 0 dB
AGC gain = 0 dB
VOFFS_RX_IN
50
mV
Max. peak input voltage
(corresponding to 62.5% of the SD
full scale)
AGC gain = 0 dB (Note 9)
VMAX_RX_IN
1.15
Vp
Input referred noise of the analog
receiver path
AGC gain = 42 dB
(Notes 9 and 10)
150
nV/√Hz
0.85
NFRX_IN
Input leakage current of receiver
input
ILE_RX_IN
--1
1
mA
IMax_REF_OUT
--300
300
mA
PSRRLPF_OUT
10
35
AGC gain step
AGCstep
5.7
6.3
dB
AGC range
AGCrange
39.9
44.1
dB
Analog ground reference output
voltage
VREF_OUT
1.52
1.78
V
SNAD_OUT
54
VCLIP_AGC_IN
1.15
Max. current delivered by REF_OUT
Power supply rejection ratio of the
receiver input section
Signal to noise ratio at 62.5% of the
SD full scale
AGC gain = 42 dB (Note 11)
AGC gain = 42 dB (Note 12)
(Notes 9 and 13)
Clipping level at the output of the
gain stage (RX_OUT)
dB
dB
1.65
Vp
9. Input at RX_IN, no other external components.
10. Characterization data only. Not tested in production.
11. A sinusoidal signal of 10 kHz and 100 mVpp is injected between VDDA and VSSA. The signal level at the differential LPF_OUT and
REF_OUT output is measured to determine the parameter.
12. A sinusoidal signal of 50 Hz and 100 mVpp is injected between VDDA and VSSA. The signal level at the differential LPF_OUT output is
measured to determine the parameter.
13. These parameters will be tested in production with an input signal of 95 kHz and 1 Vp by reading out the digital samples at the point AD_OUT
with the default settings of T_RX_MOD[7], SDMOD_TYP, DEC_TYP, and COR_F_ENA. The AGC gain is switched to 0 dB.
The receive LPF filter + AGC + low noise amplifier must have a frequency characteristic between the limits listed below. The
absolute output level depends on the operating condition. In production the measurement will be done for relative output levels
where the 0 dB reference value is measured at 50 kHz with a signal amplitude of 100 mV.
Table 13. RECEIVER FREQUENCY CHARACTERISTICS
Attenuation
Frequency (kHz)
Min
Max
Unit
10
--0.5
0.5
dB
95
--1.3
0.5
dB
130
--4.5
--2.0
dB
165
--3.0
dB
330
--18.0
dB
660
--36.0
dB
1000
--50
dB
2000
--55
dB
http://onsemi.com
13
AMIS--49587
4.1.5 Power--on--Reset (POR)
Table 14. POWER--ON--RESET (POR)
Parameter
Test Conditions
POR threshold
Power supply rise time
0 V to 3 V
Symbol
Min
VPOR
1.7
TRPOR
1
Symbol
Min
Typ
Max
Unit
2.7
V
ms
4.1.6 Digital Outputs: TDO, CLK_OUT
Table 15. DIGITAL OUTPUTS: TDO, CLK_OUT
Parameter
Test Conditions
Low output voltage
IXOUT = 4 mA
VOL
High output voltage
IXOUT = --4 mA
VOH
0.85 VDD
Symbol
Min
Typ
Max
Unit
0.4
V
V
4.1.7 Digital Outputs with Open Drains: TX_ENB, TXD
Table 16. DIGITAL OUTPUTS WITH OPEN DRAIN: TX_END, TXD
Parameter
Test Conditions
Low output voltage
IXOUT = 4 mA
Typ
VOL
Max
Unit
0.4
V
Max
Unit
0.2 VDD
V
4.1.8 Digital Inputs: BR0, BR1
Table 17. DIGITAL INPUTS: BR0, BR1
Parameter
Test Conditions
Low input level
Symbol
Min
Typ
VIL
High input level
0 V to 3 V
Input leakage current
VIH
0.8 VDD
ILEAK
--10
V
10
mA
Max
Unit
0.2 VDD
V
4.1.9 Digital Inputs with Pulldown: TDI, TMS, TCK, TRSTB, TEST
Table 18. DIGITAL INPUTS WITH PULLDOWN: TDI, TMS, TCK, TRSTB, TEST
Parameter
Test Conditions
Symbol
Min
Low input level
VIL
High input level
VIH
0.8 VDD
RPU
7
Symbol
Min
Pulldown resistor
(Note 14)
Typ
V
50
kΩ
Max
Unit
0.8 VDD
V
14. Measured around a bias point of VDD/2.
4.1.10 Digital Schmitt Trigger Inputs: RXD, RESB
Table 19. DIGITAL SCHMITT TRIGGER INPUTS: RXD, RESB
Parameter
Test Conditions
Rising threshold level
VT+
Falling threshold level
VT--
0.2 VDD
Input leakage current
ILEAK
--10
http://onsemi.com
14
Typ
V
1--
mA
AMIS--49587
4.1.11 Current Consumption
Table 20. CURRENT CONSUMPTION
Parameter
Test Conditions
Symbol
Min
Current consumption in receive mode
Current through VDD and VDDA
(Note 15)
IRX
Current consumption in transmit mode
Current through VDD and VDDA
(Note 15)
ITX
Current consumption when RESB = 0
Current through VDD and VDDA
(Note 15)
IRESET
Typ
Max
Unit
60
80
mA
60
80
mA
4
mA
15. CLKARM is < 12 MHz, fCLK = 24 MHz.
4.1.12 Main Modem Characteristics
Table 21. OPERATING CHARACTERISTICS
Parameter
Value
Unit
3.0 to 3.6
--0.7 to + 0.3
V
V
Max peak output level
1.2
Vp
HD2
--60
dB
HD3
--60
dB
ALC Steps
3
dB
ALC Range
(0 ... --21)
dB
Maximum input signal
1.15
Vp
Input impedance
100
kΩ
Input sensitivity
0.4
mV
AGC steps
6
dB
AGC range
(0 ... +42)
dB
Positive supply voltage
Negative supply voltage
Maximum 50 Hz variation
0, 1
Hz/s
300/360 (Note 22)
600/720 (Note 22)
1200/1440 (Note 22)
2400/2880(Note 22)
baud
baud
baud
baud
Frequency minimum
9
kHz
Frequency maximum
95
kHz
Frequency deviation between pairs
>10
kHz
40 (Note 16)
60 (Note 17)
80 (Note 18)
dB
dB
dB
Data rate
Programmable carrier (Note 21)
Frequency band
Dynamic range
Narrow band interfere BER (Note 19)
10E--5
Maximum 50 Hz variation
0.1
Hz/s
16. FER = 0%.
17. FER = 0.3%.
18. FER = 8.0%.
19. Signal between --60 dB and 0 dB interference signal level is 30 dB above signal level between 20 kHz and 95 kHz.
20. Input at --40 dB, duty cycle between 10 -- 50% pulse noise frequency between 100 to 1000 Hz. BER: Bit error rate FER: Frame error rate
(1frame is 288 bits).
21. Carriers frequency is programmable by steps of 10 Hz.
22. 60 Hz mains frequency.
http://onsemi.com
15
AMIS--49587
5 INTRODUCTION
5.1 GENERAL DESCRIPTION
digital. At the back--end side, the interface to the application
is done through a serial interface. The digital processing of
the signal is partitioned between hardwired blocks and a
microprocessor block. The microprocessor is controlled by
firmware. Where timing is most critical, the functions are
implemented with dedicated hardware. For the functions
where the timing is less critical, typically the higher level
functions, the circuit makes use of the ARM 7TDMI
microprocessor core.
The processor runs DSP algorithms and, at the same time,
handles the communication protocol. The communication
protocol, in this application, contains the MAC = Medium
Access Control Layer. The program running on the
microprocessor is stored into ROM. The working data
necessary for the processing is stored in an internal RAM.
At the back--end side the link to the application hardware is
provided by a Serial Communication Interface (SCI). The
SCI is an easy to use serial interface, which allows
communication between an external processor used for the
application software and the AMIS--49587 modem. The
SCI works on two wires: TXD and RXD. Baud rate is
programmed by setting 2 bits (BR0, BR1).
Because the low protocol layers are handled in the circuit,
the AMIS--49587 provides an innovative architectural split.
Thanks to this, the user has the benefit of a higher level
interface of the link to the PLC medium. Compared to an
interface at the physical level, the AMIS--49587 allows
faster development of applications. The user just needs to
send the raw data to the AMIS--49587 and no longer has to
take care of the protocol detail of the transmission over the
specific medium. This last part represents usually 50
percent of the software development costs.
The AMIS--49587 is a single chip half duplex S--FSK
modem dedicated to power line carrier (PLC) data
transmission on low-- or medium--voltage power lines. The
device offers complete handling of the protocol layers from
the physical up to the MAC. AMIS--49587 complies with
the CENELEC EN 50065--1 and the IEC 61334--5--1
standards. It operates from a single 3.3 V power supply and
is interfaced to the power line by an external power driver
and transformer. An internal PLL is locked to the mains
frequency and is used to synchronize the data transmission
at data rates of 300, 600, 1200 and 2400 baud for a 50Hz
mains frequency, or 360, 720, 1440 and 2880 baud for a
60 Hz mains frequency. In both cases this corresponds to
3,6,12 or 24 data bits per half cycle of the mains period.
S--FSK is a modulation and demodulation technique that
combines some of the advantages of a classical spread
spectrum system (e.g. immunity against narrow band
interferers) with the advantages of the classical FSK system
(low complexity). The transmitter assigns the space
frequency fS to “data 0” and the mark frequency fM to “data
1”. The difference between S--FSK and the classical FSK
lies in the fact that fS and fM are now placed far from each
other, making their transmission quality independent from
each other (the strengths of the small interferences and the
signal attenuation are both independent at the two
frequencies). The frequency pairs supported by the
AMIS--49587 are in the range of 9--95 kHz with a typical
separation of 10 kHz.
The conditioning and conversion of the signal is
performed at the analog front--end of the circuit. The further
processing of the signal and the handling of the protocol is
CLIENT
Application
SERVER
Application
SERVER
Application
SPY
Application
TEST
Application
AMIS--49587 in
MASTER mode
AMIS--49587 in
SLAVE mode
AMIS--49587 in
SLAVE mode
AMIS--49587 in
MONITOR mode
AMIS--49587 in
TEST mode
Major User Type
Minor User Type
Figure 8. Application Examples
AMIS--49587 intended to connect equipment using
Distribution Line Carrier (DLC) communication. It serves
two major and two minor types of applications:
• Major types:
♦ Master or Client:
A Master is a client to the data served by one or
many slaves on the power line. It collects data from
and controls the slave devices. A typical application
is a concentrator system.
Slave or Server:
A Slave is a server of the data to the Master. A
typical application is an electricity meter equipped
with a PLC modem.
• Minor type:
♦ Spy or Monitor:
Spy or Monitor mode is used to only listen to the
data that comes across the power line. Only the
physical layer frame correctness is checked. When
♦
http://onsemi.com
16
AMIS--49587
♦
5.2 FUNCTIONAL DESCRIPTION
the frame is correct, it is passed to the external
processor.
Test Mode:
The Test Mode is used to test the compliance of a
PLC modem conforms to CENELEC. EN 50065--1
by a Continuous broadcast of fS or fM.
The block diagram below represents the main functional
units of the AMIS--49587:
Transmitter (S--FSK Modulator)
Communication Controller
TX_ENB
TO Power Amplifier
LP
Filter
TX_OUT
Transmit Data
& Sine Synthesizer
D/A
TxD
RxD
T_REQ
BR 0
Serial
Comm.
Interface
ALC_IN
TO Application
Micro Controller
BR 1
Receiver (S-- FSK Demodulator)
RX _OUT
FROM Line Coupler
RX _IN
AAF
AGC
S--FSK
Demodulator
A/D
5
Test
Control
REF
REF_OUT
Watchdog
Zero
crossing
Clock Generator
& Timer
PLL
Timer 1 & 2
OSC
Data
RAM
AMIS--49587
VDDA
JTAG I /F
TEST
RESB
POR
Clock and Control
M50Hz_IN
RX _DATA
CRC
TX_DATA / PRE _SLOT
Local Port
ARM
Risc
Core
VSSA
VDDD
VSSD
XIN
Program
ROM
XOUT
Interrupt
Control
PC20091019.2
Figure 9. S--FSK Modem AMIS--49587 Block Diagram
5.2.1 Transmitter
”repetition with credit” function (also known as chorus
transmission). The clock generator makes use of a precise
quartz oscillator master. The clock signals are then obtained
by the use of a programmed division scheme. The support
circuits are also contained in this block. The support circuits
include the necessary blocks to supply the references
voltages for the AD and DA converters, the biasing currents
and power supply sense cells to generate the right power off
and startup conditions.
The AMIS--49587 Transmitter function block prepares
the communication signal which will be sent on the
transmitting channel during the transmitting phase. This
block is connected to a power amplifier which injects the
output signal on the mains through a line--coupler.
5.2.2 Receiver
The analog signal coming from the line--coupler is low
pass filtered in order to avoid aliasing during the
conversion. Then the level of the signal is automatically
adapted by an automatic gain control (AGC) block. This
operation maximizes the dynamic range of the incoming
signal. The signal is then converted to its digital
representation using sigma delta modulation. From then on,
the processing of the data is done in a digital way. By using
dedicated hardware, a direct quadrature demodulation is
performed. The signal demodulated in the base band is then
low pass filtered to reduce the noise and reject the image
spectrum.
24 bit @ 1200 baud
20 ms
Figure 10. Data Stream is in Sync with Zero
Crossings of the Mains (Example for 50 Hz)
Clock and Control
According to the IEC--61334--5--1 standard, the frame
data is transmitted at the zero crossing of the mains voltage.
In order to recover the information at the zero crossing, a
zero crossing detection of the mains is performed. A
phase--locked loop (PLL) structure is used in order to allow
a more reliable reconstruction of the synchronization. This
PLL permits as well a safer implementation of the
5.2.3 Communication Controller
The Communication Controller block includes the
micro--processor, its peripherals: RAM, ROM, UART,
TIMER, and the Power on reset. The processor uses the
ARM Reduced Instruction Set Computer (RISC)
http://onsemi.com
17
AMIS--49587
indicates if Receiving is in progress, or if AMIS--49587 is
waiting for synchronization, or of it configures. CRC
indicates if the received frames are valid (CRC = OK).
TX_DATA / PRE_SLOT is the output for either the
transmitting data (TX_DATA) or a synchronization signal
with the time--slots (PRE_SLOT).
architecture optimized for IO handling. For most of the
instructions, the machine is able to perform one instruction
per clock cycle. The microcontroller contains the necessary
hardware to implement interrupt mechanisms, timers and is
able to perform byte multiplication over one instruction
cycle. The microcontroller is programmed to handle the
physical layer (chip synchronization), and the MAC layer
conform to IEC 61334--5--1. The program is stored in a
masked ROM. The RAM contains the necessary space to
store the working data. The back--end interface is done
through the Serial Communication Interface block. This
back--end is used for data transmission with the application
micro controller (containing the application layer for
concentrator, power meter, or other functions) and for the
definition of the modem configuration.
5.2.5 Serial Communication Interface
The local communication is a half duplex asynchronous
serial link using a receiving input (RxD) and a transmitting
output (TxD). The input port T_REQ is used to manage the
local communication with the application micro controller
and the baud rate can be selected depending on the status of
two inputs BR0, BR1. These two inputs are taken in account
after an AMIS--49587 reset. Thus when the application
micro controller wants to change the baud rate, it has to set
the two inputs and then provoke a reset.
5.2.4 Local Port
The controller uses 3 output ports to inform about the
actual status of the PLC communication. RX_DATA
6 DETAILED HARDWARE DESCRIPTION
6.1 CLOCK AND CONTROL
M50Hz_IN
Zero
crossing
PLL
CHIP_CLK
Clock Generator
& Timer
Figure 11. Clock and Control Block
6.1.1 Zero Crossing Detector
PRE_SLOT
PRE_F RAME_CLK
FRAME_CLK
BYTE_CLK
BIT_CLK
Clock and Control
PRE_BYTE_CLK
output of this block is the clock signal CHIP_CLK, 8 times
over sampled with the bit rate. The oscillator makes use of
a precise 24 MHz quartz. This clock signal together with
CHIP_CLK is fed into the Clock Generator and time block.
Here several internal clock signals and timings are obtained
by the use of a programmed division scheme.
According to the IEC 61334--5--1 standard, the frame data
is transmitted at the zero crossing of the mains voltage. In
order to recover the information at the zero crossing, a zero
crossing detection of the mains is performed. A
phase--locked loop (PLL) structure is used in order to allow
a more reliable reconstruction of the synchronization. The
OSC
XIN
XOUT
frequency. In case of direct connection to the mains it is
advised to use a series resistor of 1 MΩ in combination with
two external clamp diodes in order to limit the current
flowing through the internal protection diodes.
M50HZ_IN is the mains frequency analog input pin. The
signal is used to detect the zero crossing of the 50 or 60 Hz
sine wave. This information is used, after filtering with the
internal PLL, to synchronize frames with the mains
http://onsemi.com
18
AMIS--49587
Clock & Control
3V3_A
FROM
MAINS
1 MΩ
M50Hz_IN
Debounce
Filter
ZeroCross
PLL
CHIP_CLK
Figure 12. Zero Cross Detector with Falling Edge Debouncer
The zero crossing detector output is logic zero when the
input is lower than the falling threshold level and a logic one
when the input is higher than the rising threshold level. The
falling edges of the output of the zero crossing detector are
de--bounced by a period between 0.5 ms and 1 ms. The
Rising edges are not de--bounced.
VMAINS
VIRM50HZIN
VIFM50HZIN
t
ZeroCross
tZCD
tDEBOUNCE = 0,5 .. 1 ms
10 ms
Figure 13. Zero Cross Detector Signals and Timing (Example for 50 Hz)
6.1.2 50/60 Hz PLL
Table 22. CHIP_CLK IN FUNCTION OF SELECTED
BAUD RATE AND MAINS FREQUENCY
The output of the zero crossing detector is used as an input
for a PLL. The PLL generates the clock CHIP_CLK which
is 8 times the bit rate and which is in phase with the rising
edge crossings. The PLL locks on the zero crossing from
negative to positive phase. The bit rate is always an even
multiple of the mains frequency, so following combinations
are possible:
BAUD[1:0]
MAINS_FREQ
00
01
10
50 Hz
Baudrate
CHIP_CLK
300
2400 Hz
600
4800 Hz
1200
9600Hz
11
2400
19200 Hz
00
360
2880 Hz
01
720
5760 Hz
1440
11520Hz
2880
23040 Hz
10
11
60 Hz
In case no zero crossings are detected the PLL freezes its
internal timers in order to maintain the CHIP_CLK timing.
http://onsemi.com
19
AMIS--49587
V MAINS
VIR M 50HZIN
t
6 bit @ 300 baud
ZeroCross
t ZCD
PLL in lock
CHIP _CLK
Start of Physical PreFrame*
10 ms
*The start of the Physical Subframe is shifted back with R_ZC_ADJUST[7:0] x 26 mS = tZCD to compensate for the zero cross delay
Figure 14. Zero Cross Adjustment to Compensate for Zero Cross Delay (Example for 50 Hz)
The phase difference between the zero crossing of the
mains and CHIP_CLK can be tuned. This opens the
possibility to compensate for external delay tZCD(e.g. opto
coupler) and for the 1.9 V positive threshold VIRM50HZIN
of the zero crossing detector. This is done by pre--loading the
PLL counter with a number value stored in register
R_ZC_ADJUST[7:0]. The adjustment period or granularity
is 26 ms. The maximum adjustment is 255 x 26 ms = 6.6 ms
which corresponds with 1/3rd of the mains sine period.
XTAL _IN
CX
0 ms
0000 0001
26 ms
0000 0010
52 ms
0000 0011
78 ms
…
…
1111 1101
6589 ms
1111 1110
6615 ms
1111 1111
6641 ms
CX
VSSA
Figure 15. Placement of the Capacitors and Crystal
with Clock Signal Generated Internally
Compensation
0000 0000
XTAL _ OUT
24 MHz
Table 23. ZERO CROSS DELAY COMPENSATION
R_ZC_ADJUST[7:0]
RX
For correct functionality the external circuit illustrated in
Figure 15 must be connected to the oscillator pins. For a
crystal requiring a parallel capacitance of 20 pF CX must be
around 30 pF. (Values of capacitors are indicative only and
are given by the crystal manufacturer). To guarantee startup
the series loss resistance of the crystal must be smaller than
80 Ω. A parallel resistor RX = 1 MΩ is recommended to
improve the clock symmetry.
The oscillator output fCLK = 24 MHz is the base
frequency for the complete IC. The clock frequency for the
ARM fARM = fCLK. The clock for the transmitter, fTX_CLK
is equal to fCLK / 2 or 12 MHz. All the transmitter internal
clock signals will be derived from fTX_CLK. The clock for
the receiver, fRX_CLK is equal to fCLK / 4 or 6 MHz. All the
receiver internal clock signals will be derived from
fRX_CLK.
6.1.3 Oscillator
The oscillator works with a standard parallel resonance
crystal of 24 MHz. XIN is the input to the oscillator inverter
gain stage and XOUT is the output.
http://onsemi.com
20
AMIS--49587
6.1.4 Clock Generator and Timer
The timing generator is the same for transmit and receive
mode. When AMIS--49587 switches from receive to
transmit and back from transmit to receive, the
R_CHIP_CNT counter value is maintained. As a result all
timing signals for receive and transmit have the same
relative timing. The following timing signals are defined as:
The CHIP_CLK and fCLK are used to generate a number
of timing signals used for the synchronization and interrupt
generation. The timing generation has a fixed repetition rate
which corresponds to the length of a physical subframe. (see
paragraph Send and Receive network data).
Start of the physical subframe
R_CHIP_CNT
2871 2872
2879
0
1
2
3
4
5
6
7
8
9
63
64
65
CHIP_CLK
BIT_CLK
BYTE_CLK
FRAME_CLK
PRE_BYTE_CLK
PRE_FRAME_CLK
PRE_SLOT
Figure 16. Timing Signals
CHIP_CLK is the output of the PLL and 8 times the bit rate on the physical interface. See also paragraph 50/60 Hz PLL
BIT_CLK is active at counter values 0,8,16, .. 2872 and inactive at all other counter values. This signal is used to indicate
the transmission of a new bit.
BYTE_CLK is active at counter values 0,64,128, .. 2816 and inactive at all other counter values. This signal is used to indicate
the transmission of a new byte.
FRAME_CLK is active at counter values 0 and inactive at all other counter values. This signal is used to indicate the
transmission or reception of a new frame.
PRE_BYTE_CLK is a signal which is 8 CHIP_CLK sooner than BYTE_CLK. This signal is used as an interrupt for the
internal microcontroller and indicates that a new byte for transmission must be generated.
PRE_FRAME_CLK is a signal which is 8 CHIP_CLK sooner than FRAME_CLK. This signal is used as an interrupt for
the internal microcontroller and indicates that a new frame will start at the next FRAME_CLK.
PRE_SLOT is logic 1 between the rising edge of PRE_FRAME_CLK and the rising edge of FRAME_CLK. This signal can
be provided at the digital output pin TX_DATA_PRE_SLOT when R_CONF[7] = 0 (See paragraph WriteConfigRequest, field
TX_DATA_PRE--SLOT_SEL) and can be used by the external host controller to synchronize its software with the
FRAME_CLK of AMIS--49587.
http://onsemi.com
21
AMIS--49587
6.2 TRANSMITTER PATH DESCRIPTION (S--FSK
modulation technique is used. In the analog domain, the
signal is low pass filtered, in order to remove the high
frequency quantization noise, and passed to the automatic
level controller (ACL) block, where the level of the
transmitted signal can be adjusted. The determination of the
signal level is done through the sense circuitry.
MODULATOR)
For the generation of the space and mark frequencies, the
direct digital synthesis (DDS) of the sine wave signals is
performed under the control of the microprocessor. After a
signal conditioning step, a digital to analog conversion is
performed. As for the receive path, a sigma delta
Transmitter (S--FSK Modulator)
TX_EN
ALC_IN
ALC
control
TX_OUT
LP
Filter
ARM
Interface
&
Control
D/A
Transmit Data
& Sine Synthesizer
fMI
f MQ
fSI
fSQ
TO RECEIVER
Figure 17. Transmitter Block Diagram
6.2.1 ARM Interface and Control
Table 24. FS AND FM STEP REGISTERS
The interface with the ARM consists in a 8--bit data
registers R_TX_DATA, 2 control registers R_TX_CTRL
and R_ALC_CTRL, a flag TX_RXB defining transmit and
receive and 2 16--bit wide frequency step registers R_FM
and R_FS defining fM (mark frequency = data 1) and fS
(space frequency = data 0). All these registers are memory
mapped. Some of them are for internal use only and cannot
be accessed by the user.
The processing of the physical frame (preamble, MAC
address, CRC) is done by the ARM.
ARM
Register
Hard
Reset
Soft
Reset
R_FS[15:0]
0000h
0000h
Step register for the
space frequency fS
R_FM[15:0]
0000h
0000h
Step register for the
mark frequency fM
Description
The space and mark frequency can be calculated as:
• fS = R_FS[15:0]_dec x fDDS/218
• fM = R_FM[15:0]_dec x fDDS/218
6.2.2 Sine Wave Generator
Or the content of both R_FS[15:0] and R_FM[15:0] are
defined as:
• R_FS[15:0]_dec = Round(218 x fS/fDDS)
• R_FM[15:0]_dec = Round(218 x fM/fDDS)
Where fDDS = 3 MHz is the direct digital synthesizer
clock frequency.
After a hard or soft reset or at the start of the transmission
(when TX_RXB goes from 0 to 1) the phase accumulator
A sine wave is generated with a direct digital synthesizer
DDS. The synthesizer generates in transmission mode a sine
wave either for the space frequency (fS, data 0) or for the
mark frequency (fM, data1). In reception the synthesizer
generates the sine and cosine waves for the mixing process,
fSI, fSQ, fMI, fMQ (space and mark signals in phase and
quadrature). The space and mark frequencies are defined in
an individual step 16 bit wide register.
http://onsemi.com
22
AMIS--49587
0 when AMIS--49587 is in transmit mode. When going from
transmit to receive mode (TX_RXB goes from 1 to 0) the
TX_ENB signal is kept active for a short period of
tdTX_ENB.
The control logic for the transmitter generates a signal
TX_DATA which corresponds to the transmitted S--FSK
signal. When transmitting fM TX_DATA is logic 1. When
transmitting fS TX_DATA is logic 0. When the transmitter
is not enabled (TX_RXB = 0) TX_DATA goes to logic 1 at
the next BIT_CLK.
must start at it’s 0 phase position, corresponding with a 0 V
output level. When switching between fM and fS the phase
accumulator must give a continuous phase and not restart
from phase 0.
When AMIS--49587 goes into receive mode (when
TX_RXB goes from 1 to 0) the sine wave generator must
make sure to complete the active sine period.
The control logic for the transmitter generates a signal
TX_ENB to enable the external power amplifier. TX_ENB
is 1 when the AMIS--49587 is in receive mode. TX_ENB is
BIT_CLK
TX_DATA
TX_RXB
TX_ENB
TX_OUT
tdTX_ENB
Figure 18. TX_ENB Timing
6.2.3 DA Converter
After hard or soft reset the level is set at minimum level
(maximum attenuation) When going to reception mode
(when TX_RXB goes from 1 to 0) the level is kept in
memory so that the next transmit frame starts with the old
level. The evaluation of the level is done during 1
CHIP_CLK period.
Depending on the value of peak level on ALC_IN the
attenuation is updated:
-- VpALC_IN < VTLALC: Increase the level with 1 step
-- VTLALC ≤ VpALC_IN ≤ VTHALC: Don’t change the
level
-- VpALC_IN > VTHALC: Decrease the level with 1 step
The gain changes in the next CHIP_CLK period.
An evaluation phase and a level adjustment takes 2
CHIP_CLK periods. ALC operation is enabled only during
the first 16 CHIP_CLK cycles after a hard or soft reset or
after going into transmit mode.
The automatic level control can be disabled by setting
register R_ALC_CTRL[3] = 1. In this case the transmitter
A digital to analog ΣΔ converter converts the sine wave
digital word to a pulse density modulated (PDM) signal.
The PDM signal is converted to an analog signal with a first
order switched capacitor filter.
6.2.4 Low Pass Filter
A 3rd order continuous time low pass filter in the transmit
path filters the quantization noise and noise generated by the
ΣΔ DA converter. The low pass filter has a circuit which
tunes the RC time constants of the filter towards the process
characteristics. The C values for the LPF filter are controlled
by the ARM micro controller.
6.2.5 Amplifier with Automatic Level Control (ALC)
The pin ALC_IN is used for level control of the
transmitter output level. First a peak detection is done. The
peak value is compared to 2 thresholds levels: VTLALC_IN
and VTHALC_IN. The result of the peak detection is used to
control the setting of the level of TX_OUT. The level of
TX_OUT can be attenuated in 8 steps of 3 dB typical.
http://onsemi.com
23
AMIS--49587
6.3 RECEIVER PATH DESCRIPTION
output level is fixed to the programmed level in the register
R_ALC_CTRL[2:0].
See
also
paragraph.
WriteConfigRequest.
6.3.1 Receiver Block Diagram
The receiver takes in the analog signal from the line
coupler, conditions it and demodulates it in a data--stream to
the communication controller. The operation mode and the
baud rate are made according to the setting in R_CONF,
R_FS and R_FM. The receive signal is applied first to a high
pass filter. Therefore AMIS--49587 has a low noise
operational amplifier at the input stage which can be used to
make a high pass active filter to attenuate the mains
frequency. This high pass filter output is followed by a gain
stage which is used in an automatic gain control loop. This
block also performs a single ended input to differential
output conversion. This gain stage is followed by a
continuous time low pass filter to limit the bandwidth. A 4th
order sigma delta converter converts the analog signal to
digital samples. A quadrature demodulation for fS and fM is
than performed by the ARM micro, as well the handling of
the bits and the frames.
Table 25. FIXED TRANSMITTER OUTPUT
ATTENUATION
ALC_CTRL[2:0]
Attenuation
000
0 dB
001
--3 dB
010
--6 dB
011
--9 dB
100
--12 dB
101
--15 dB
110
--18 dB
111
--21 dB
Remark: The analog part of AMIS--49587 works with an
analogue ground REF_OUT. When connecting
AMIS--49587 to external circuitry working with another
ground one must make sure to place a decoupling capacitor.
RX_OUT
Receiver (Analog Path)
FROM
DIGITAL
LOW NOISE
OPAMP
RX_IN
Gain
4th
Order
ΣΔ AD
LPF
TO
DIGITAL
REF_OUT
REF
1.65 V
Figure 19. Analog Path of the Receiver
FROM TRANSMITTER
Receiver (Digital Path)
fMI
fMQ fSI
2nd
FROM
ANALOG
Quadrature Demodulator
f SQ
IM
Decimator
Noise
Shaper
st
1
Decimator
Sliding
Filter
fM
f MQ
Compen-sator
2nd
QM
Sliding
Filter
IS
Sliding
Filter
Decimator
fSI
TO
GAIN
2nd
AGC
Control
Abs
value
accu
fSQ
Decimator
2nd
Decimator
QS
Sliding
Filter
fS
SOFTWARE
Figure 20. Digital Path of the Receiver ADC and Quadrature Demodulation
http://onsemi.com
24
AMIS--49587
6.3.2 50/60 Hz Suppression Filter
minimum number of external components. Pin RX_IN is
the positive input and RX_OUT is the output of the input
low noise operational amplifier. The pin REF_OUT can be
use as an analog ground (1.65 V) for the external circuitry.
AMIS--49587 receiver input provides a low noise input
operational amplifier in a follower configuration which can
be used to make a 50/60 Hz suppression filter with a
R2
C2
Received
Signal
C1
RX_OUT
RX_IN
2
Receiver (S-- FSK Demodulator)
LOW NOISE
OPAMP
3
TO AGC
R1
REF_OUT
4
1, 65 V
CDREF
REF
V SSA
Figure 21. External Component Connection for 50/60 Hz Suppression Filter
attenuation of 85 dB at 50 Hz is obtained. Figure 21
represents external components connection. In a typical
application the coupling transformer in combination with a
parallel capacitance forms a high pass filter with a typical
attenuation of 60 dB. The combined effect of the two filters
decreases the voltage level of 230 Vrms at the mains
frequency well below the sensitivity of the AMIS--49587.
RX_IN is the positive analog input pin of the receiver low
noise input op--amp. Together with the output RX_OUT an
active high pass filter is realized. This filter removes the
main frequency (50 Hz or 60 Hz) from the received signal.
The filter characteristics are determined by external
capacitors and resistors. Typical values are given in
Table 26. For these values and after this filter, a typical
Vin/Vrx_out (dB)
20
--20
--60
--100
--140
10
100
1k
Frequency (Hz)
10k
Figure 22. Transfer Function of 50 Hz Suppression Circuit
REF_OUT is the analog output pin which provides the
voltage reference used by the A/D converter. This pin must
be decoupled from the analog ground by a 1 mF ceramic
capacitance (CDREF). It is not allowed to load this pin.
The low noise operational amplifier can be bypassed and
powered down by setting the bit R_RX_MOD[7] to 1. In
this mode the pin RX_OUT must be used as input of the
AGC.
http://onsemi.com
25
100k
AMIS--49587
6.3.5 A/D Converter
Table 26. VALUE OF THE RESISTORS AND
CAPACITORS
Component
Value
Unit
C1
1.5
nF
C2
1.5
nF
CDREF
1
mF
R1
22
kΩ
R2
11
kΩ
The output of the low pass filter is input for an analog 4th
order sigma--delta converter. The DAC reference levels are
supplied from the reference block. The digital output of the
converter is fed into a noise shaping circuit blocking the
quantization noise from the band of interest, followed by a
sinc5 decimation and a compensation step.
6.3.6 Quadrature Demodulator
The quadrature demodulation block takes the AD signal
and mixes it with the in--phase and quadrature phase of the
fS and fM carrier frequencies. After a low pass filter and
rectification the mixer output signals are further processed
in software. There the accumulation over a period of
CHIP_CLK is done which results in the discrimination of
data 0 and data 1.
Remark: The analog part of AMIS--49587 is referenced
to the internal analog ground REF_OUT = 1.65 V (typical
value). If the external circuitry works with a different
analogue reference level one must be sure to place a
decoupling capacitor.
6.3.3 Auto Gain Control (AGC)
6.4 COMMUNICATION CONTROLLER
The receiver path has a gain stage which is used for
automatic gain control. The gain can be changed in 8 steps
of 6 dB. The control of the AGC is done by a digital circuit
which measures the signal level after the AD converter, and
regulates the average signal in a window around a
percentage of the full scale. The AGC works in 2 cycles: a
measurement cycle at the rising edge of the CHIP_CLK and
an update cycle starting at the next CHIP_CLK.
The Communication Controller block includes the ARM
32 bit RISC processor operating in the 16--bit Thumb mode,
its peripherals: Data RAM, Program ROM, TIMERS 1 & 2,
Interrupt Control, TEST Control, Watchdog & Power On
Reset (POR), I/O ports and the Serial Communication
Interface (SCI). The micro--processor is programmed to
handle the physical layer (chip synchronization), and the
MAC layer conform to IEC 61334--5--1. The program is
stored in a masked ROM. The RAM contains the necessary
space to store the working data. The back--end interface is
done through the Local Port and Serial Communication
Interface block. This back--end is used for data transmission
with the application micro controller (containing the
application layer for concentrator, power meter, or other
functions) and for the definition of the modem
configuration.
6.3.4 Low Noise Anti Aliasing Filter
The receiver has a 3rd order continuous time low pass
filter in the signal path. This filter is in fact the same block
as in the transmit path which can be shared because
AMIS--49587 works in half duplex mode. It has a circuit
which tunes the RC time constants of the filter towards the
process characteristics. The C values for the LPF filter are
controlled by the ARM micro controller. When switching
between receive and transmit mode (and visa versa) the tune
circuit does not need to be updated.
http://onsemi.com
26
AMIS--49587
TX_ENB
Communication Controller
Data
RAM
Program
ROM
Serial
Comm.
Interface
TxD
RxD
T_REQ
BR0
BR1
ARM
Risc
Core
Local Port
Timer 1 & 2
POR
TO
TRANSMIT
FROM
RECEIVER
RX_DATA
CRC
TX_DATA / PRE _SLOT
RESB
Watchdog
Test
Control
Interrupt
Control
TEST
TRSTB
TCK
TMS
TDO
TDI
Figure 23. Communication Controller
6.4.1 Local Port
indicates if the received frames are valid: the cyclic
redundancy code (CRC) is correct. TX_DATA/PRE_SLOT
is the output for either the transmitting data (TX_DATA) or
a synchronization signal with the time--slots (PRE_SLOT).
The controller uses 3 output ports to inform the actual
status of the PLC communication. RX_DATA indicates if
AMIS--49587 is waiting for its configuration, if it is in
research of synchronization, or if it is receiving data. CRC
http://onsemi.com
27
AMIS--49587
Table 27. OVERVIEW FUNCTIONALITY LOCAL PORT
Port
Function
Value
Explanation
Remark
RX_DATA
Data reception
10 Hz
Waiting for configuration
Output is oscillating
0
After Synchro Confirm Time--out
1
Research of synchronization
CRC
TX_DATA /
PRE_SLOT
CRC OK
0
TX_DATA
PRE_SLOT
1
During the pause between 2 timeslots when a correct
frame is received
See paragraph Send
and Receive
Network Data with
the AMIS--49587
0
Transmit of fS
R_CONF[7] = 1
1
Transmit of fM
0
See Figure 16: Timing Signals
1
See Figure 16: Timing Signals
6.4.2 Serial Communication Interface (SCI)
♦
The Serial Communication
Interface allows
asynchronous communication. It can communicate with a
UART = Universal Asynchronous Receiver Transmitter,
ACIA = Asynchronous Communication Interface Adapter
and all other chips that employ standard asynchronous serial
communication. The serial communication interface has
following characteristics:
♦
♦
♦
♦
♦
Half duplex.
Standard NRZ format.
Start bit, 8 data bits and 1 stop bit.
Hardware programmable baud--rate (4800, 9600,
19200 and 38400 baud).
0--5 V levels with open drain for TxD.
0--5 V levels for RxD and T_REQ.
AMIS-- 49587
TxD
RxD
Serial
Comm.
Interface
T_REQ
BR0
ARM
Risc
Core
BR1
Application
Micro
Controller
RX_DATA
CRC
Local Port
TX_DATA /
PRE_SLOT
Communication Controller
Figure 24. Connection to the Application Microcontroller
http://onsemi.com
28
R_CONF[7] = 0
AMIS--49587
BR0, BR1: Baud rate selection inputs.
These pins are externally strapped to a value or controlled
by the external application micro controller.
6.4.3 Serial Communication Interface Physical Layer
Description
The following pins control the serial communication
interface.
TXD: Transmit data output.
It is the data output of the AMIS--49587 and the input of the
application micro controller.
RXD: Receive data input.
It is the data input of the AMIS--49587 and the output of the
application micro controller.
T_REQ:Transmit Request input
Request for data transmission received from the application
micro controller.
IDLE (mark)
Table 28. BR1, BR0 BAUD RATES
BR1
BR0
SCI Baud Rate
0
0
4800
0
1
9600
1
0
19200
1
1
38400
LSB
Start
D0
MSB
D1
D2
tBIT
D3
D4
8 data bits
D5
D6
D7
IDLE (mark)
Stop
tBIT
1 character
Figure 25. Data Format
6.4.4 Arbitration and Transfer
AMIS--49587 answers within the tPOLL delay with the status
message in which the application micro controller can read
if the communication channel is available. If the
communication is possible, the application micro controller
can start to send its local frame within the tSR delay. It should
pull up the T_REQ signal as soon as the first character
(STX) has been sent. If the beginning of the local frame is
not received before the tSR delay was issued, the
AMIS--49587 ignores the local frame. At the end of the data
reception sent by the application micro controller on the
RxD line, the AMIS--49587 sends a byte on the TxD line in
order to inform about the status of the transmitting <ACK>
(=0x06) or <NAK> (=0x15).
Remark: If the application micro controller only wants to
know the state of the AMIS--49587, it has just to pull up the
T_REQ signal after the reception of the status message.
In order to avoid collisions between the data sent by the
AMIS--49587 and the application micro controller, the
AMIS--49587 is chosen as the transmitting controller. This
means that when there is no local transfer, the AMIS--49587
can initiate a local communication without taking account
of the application micro controller state. On the other hand,
when the application micro controller wants to send data
(using a local frame), it must first send a request for
communication through the local input port named T_REQ
(Transmitting Request). Then the AMIS--49587 answers
with a status message.
6.4.5 Transfer from Application Microcontroller to
AMIS--49587
When the application micro controller wants to initiate a
local transfer, it must pull down the T_REQ signal. The
http://onsemi.com
29
AMIS--49587
T_REQ
tPOLL
TxD
Status Message
ACK
tSR
RxD
t ACK
Local Frame from Base Micro
Figure 26. Transfer from Application Microcontroller to AMIS--49587
6.4.6 Transfer from AMIS--49587 to Application
Microcontroller
If the length and the checksum of the local frame are both
correct, the AMIS--49587 acknowledges with an <ACK>
character. In other cases, it answers with a <NAK>
character. In case of <NAK> response, or no
acknowledgement from AMIS--49587 in the tACK time--out,
a complete sequence must be restarted to repeat the frame.
When the AMIS--49587 wants to send a frame, it can
directly send it without any previous request.
T_REQ
TxD
Local Frame from
AMIS--49587
Local Frame from
AMIS--49587
tACK
t WBC
tACK
NAK
RxD
Local Frame from
AMIS--49587
t WBC
ACK
Figure 27. Transfer from AMIS--49587 to Application Microcontroller
application micro controller or a framing error when an
<ACK> character is awaited is considered as an
acknowledgment.
If the length and the checksum of the local frame are both
correct, the application micro controller acknowledges with
an <ACK> character. In other cases, it answers with a
<NAK> character. In case of <NAK> response from the
Application micro controller, the AMIS--49587 will repeat
the frame only once after a delay corresponding to tWBC
(Wait Before Continue). A non response from the
6.4.7 Character Time--out in Reception
The time between two consecutive characters in a local
frame should not exceed tIC (Time--out Inter Character):
tIC
Character
Character
Figure 28. Character Time--out
http://onsemi.com
30
t
AMIS--49587
After this delay, the frame reception is finished. If the
length and the checksum are both correct, the local frame is
taken in account otherwise all previous characters are
discarded. The time out Inter Character (tIC) is set by default
at 10 ms after a reset. The time out Inter character (tIC) is
modified by the bit 7 of repeater parameter in the
configuration frame:
♦
♦
bit 7 = 1 --> the tIC value is constant at 10 ms,
bit 7 = 0 --> the tIC value represents 5 characters
depending on the communication speed (defined by
two local input ports BR0 and BR1).
See Table 29: Timings for Time--out Values.
Table 29. TIME-OUT VALUES
Time-out
Meaning
Value
Tpoll
Delay max. awaited by the base micro between the T_REQ pull down
and the status message transmission (delay polling)
Tsr
Delay max. awaited by the AMIS--49587 between the end of the status
transmitting and the reception of the STX character in the base micro
frame (delay status/reception)
200 ms
Tack
Delay max. awaited by either the AMIS--49587 or the base micro
between the end of a transmitting and the reception of the ACK or NAK
character sent by the other (delay ACK).
40 ms
Twbc
Delay max. awaited by either the AMIS--49587 or the base micro
between the end of a reception and the transmission of the next frame
(delay waiting before continue).
5 ms
Tic
Delay max. awaited by either the AMIS 49587 or the
base micro between two characters
(delay inter characters)
Programmable with bit 7 of the repeater parameter in the
configuration frame
6.4.8 Watchdog
20 ms
Bit 7 = 1
Bit 7 = 0
10 ms
4800 baud
10 ms
9600 baud
5 ms
19200 baud
2.5 ms
38400 baud
1.25 ms
interface. See also paragraph Configuration of the
AMIS--49587. An overview of the accessible configuration
registers is given below:
R_CONFIG register configures the AMIS_49587 in the
correct mode. The R_CONFIG register is controlled by the
embedded software and can be accessed via a
WriteConfig_Request.
The watchdog supervises the ARM and in case the
firmware doesn’t acknowledge at periodic times, a hard
reset is generated.
6.4.9 Configuration Registers
A number of configuration registers can be accessed by
the user by sending a WriteConfig_Request over the SCI
Table 30. R_CONF[9:0] (See Table 41: Configuration Parameters)
ARM Register
Hard Reset
Soft Reset
Description
R_CONF[7]
0
--
TX_DATA_PRE_SLOT_SEL
R_CONF[5:3]
000
--
MODE
R_CONF[2:1]
00
--
BAUDRATE
R_CONF[0]
0
--
MAINS_FREQ
Where:
TX_DATA_PRE_SLOT_SEL:
MODE:
BAUDRATE:
0:
1:
000:
001:
010:
011:
1xx:
00:
01:
10:
TX_DATA/PRE_SLOT is PRE_SLOT output pin
TX_DATA/PRE_SLOT is TX_DATA output pin
Initialization
Master Mode
Slave Mode
Reserved
Test Mode
6 data bits per mains period = 300 baud @ 50 Hz
12 data bits per mains period = 600 baud @ 50 Hz
24 data bits per mains period = 1200 baud @ 50 Hz
http://onsemi.com
31
AMIS--49587
11:
48 data bits per mains period = 2400 baud @ 50 Hz
0:
50 Hz
1:
60 Hz
R_FS and R_FM step registers are defining the space and mark frequency. Explanation on the values can be found in paragraph
Sine wave generator. This register can be accessed via a WriteConfig_Request.
MAINS_FREQ:
Table 31. FS AND FM STEP REGISTERS (See Table 41: Configuration Parameters)
ARM Register
Hard Reset
Soft Reset
Description
R_FS[15:0]
0000h
0000h
Step register for the space frequency fS
R_FM[15:0]
0000h
0000h
Step register for the mark frequency fM
R_ZC_ADJUST register defines the value which is pre--loaded in the PLL counter. This is used to fine tune the phase
difference between HIP_CLK, CIP_CLK and the – to + zero crossing of the mains. Explanation on the values can be found
in paragraph 50/60 Hz PLL. This register can be accessed via a WriteConfig_Request.
Table 32. ZC_ADJUST REGISTERS (See Table 41: Configuration Parameters)
ARM Register
Hard Reset
Soft Reset
Description
R_ZC_ADJUST[7:0]
02h
02h
Fine tuning of phase difference between CHIP_CLK and rising
edge of Mains zero crossing
R_ALC_CTRL register enables or disables the Automatic Level Control. In case ALC is disabled the attenuation of the
TX output driver is fixed according to the value in R_ALC_CTRL[2:0]. Explanation on the attenuation values can be found
in paragraph Amplifier with Automatic Level Control. This register can be accessed via a WriteConfig_Request.
Table 33. ALC_CTRL REGISTERS (See appendix C)
ARM Register
Hard Reset
Soft Reset
Description
R_ALC_CTRL[3:0]
00h
00h
Control register for the automatic level control
Where:
R_ALC_CTRL[3]:
R_ALC_CTRL[2:0]:
0:
Automatic level control is enabled
1:
Automatic level control is disabled and attenuation is fixed
Fixed attenuation value
hard reset is active when pin RESB = 0 or when the power
supply VDD < VPOR (See Table 14 Power On Reset). When
switching on the power supply the output of the crystal
oscillator is disable until a few 1000 clock pulses have been
detected, this to enable the oscillator to start up.
The soft reset initializes part of the hardware. The soft
reset is activated when going into initialization mode for the
duration of maximum 1 CHIP_CLK. Initialization mode is
entered by R_CONF[5:3] = 000.
The concept of AMIS--49587 has a number of provisions
to have low power consumption. When working in transmit
mode the analogue receiver path and most of the digital
receive parts are disabled. When working in receive mode
the analog transmitter and most of the digital transmit parts,
except for the sine generation, are disabled.
When the pin RESB = 0 the power consumption is
minimal. Only a limited power is necessary to maintain the
bias of a minimum number of analog functions and the
oscillator cell.
Table 34. FIXED TRANSMITTER OUTPUT
ATTENUATION
ALC_CTRL[2:0]
Attenuation
000
0 dB
001
--3 dB
010
--6 dB
011
--9 dB
100
--12 dB
101
--15 dB
110
--18 dB
111
--21 dB
6.4.10 Reset and Low Power
AMIS--49587 has 2 reset mode: hard reset and soft reset.
The hard reset initializes the complete IC (hardware and
ARM) excluding the data RAM for the ARM. This makes
sure that start--up of hardware and ARM is guaranteed. A
http://onsemi.com
32
AMIS--49587
7 DETAILED SOFTWARE DESCRIPTION
Figure 29 depicts a typical PLC network with one master and 2 slaves. Each AMIS--49587 is controlled by an external CPU
over a RS232 interface. See paragraph Serial Communication Interface Physical Layer Description for a description on
hardware signals and timings.
LCC
layer
External CPU
RS232
MAC
layer
Physical
Layer
AMIS49587
Physical
Layer
AFE
PLC Master or Client
Power Line
AFE
MAC
layer
RS232
AMIS49587
LCC
layer
External CPU
PLC Slave or Server
Physical
Layer
AFE
MAC
layer
AMIS49587
RS232
LCC
layer
External CPU
PLC Slave or Server
Figure 29. Typical PLC Network Architecture
This document describes how the RS232 frames need to be
composed to:
♦ Get status information from the AMIS--49587
♦ Configure the AMIS--49587
♦ Send and Receive network data with the
AMIS--49587
♦ Get performance and data path statistics from
AMIS--49587
This is the state of the AMIS--49587 after a
hardware reset or after a reset command has been
sent to it.
Each mode has its own configuration parameters and
subset of commands.
7.2 OBTAINING STATUS MESSAGES
Opposite to all other commands over the serial interface,
the status message is retrieved from the AMIS--49587 by a
hardware event only. To get the status message the serial
driver on the external CPU needs to pull the T_REQ HW pin
low, like described in paragraph Serial Communication
Interface Physical Layer Description.
Whenever the external controller sends a command to the
AMIS--49587, the T_REQ HW pin should be pulled low to
get a new status message from the MODEM. Only when the
status message indicates that the buffer is not busy, the
command may be send. The AMIS49587 is the master on
the serial interface and needs to be queried to get access to
the bus.
The format of the status message depends on the active
configuration of the AMIS--49587 (not set, slave, master or
monitor).
7.1 CONFIGURE THE AMIS--49587
The AMIS--49587 can operate in different configurations:
♦ Master or Client configuration: A Master is a client
to the data served by one or many slaves on the
power line. It collects data from and controls the
slave devices.
♦ Slave or Server configuration: A Slave is a server of
the data to the Master.
♦ Spy or Monitor configuration: Spy or Monitor mode
is used to only listen to the data that comes across
the power line. Only the physical layer frame
correctness is checked (preamble and SSD, see
Figure 34 Power Line Data Frame Structure). When
the frame is correct, it is passed to the external
processor.
♦ Not set configuration: No valid configuration
command has been passed to the AMIS--49587 after
reset. No power line communication is possible.
Table 35. SERIAL PORT STATUS FRAME LAYOUT
START
http://onsemi.com
33
Status_Data
AMIS--49587
Table 36.
Field
Byte Length
Value
Description
START
1
3Fh
Character (”?”), indicating start of status message.
Status_Data
4
Byte String
4 bytes encoding different status bits
Important: Frame in little endian format (LSByte first)
STATUS MESSAGE IN NOT SET MODE
Structure
Byte
Content
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
1
Start
0
1
1
1
1
1
1
1
2
Data 1
x
x
x
x
x
x
Not SET
X
3
Data 2
4
Data 3
RSV[7:0]
SVN[7:4]
Where:
Not SET
RSV[7:0]
SVN[7:4]
SVN[3:0]
x
SVN[3:0]
Indicates if AMIS--49587 has received a valid configuration
Reserved
Software Version Number: major release
Software Version Number: minor release
Not Used
7.2.1 Status Message in SLAVE or SERVER MODE:
STATUS MESSAGE IN SLAVE MODE
Structure
Byte
Content
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
1
Start
0
1
1
1
1
1
1
1
2
Data 1
x
x
x
Not
LOCKED
NEW
Not SYNC
Not
SET
Buffer
BUSY
3
Data 2
TS_Nb[2:0]
x
x
x
ALARM
_EN
PLL
_LOCK
4
Data 3
DEP[2:0]
Where:
Not LOCKED
NEW
Not SYNC
Not SET
Buffer BUSY
TS_Nb[2:0]
Alarm_EN
PLL_LOCK
DEP[2:0]
MDC[2:0]
REP[1:0]
x
MDC[2:0]
Indication if AMIS 4958x is Unlocked
Indication if AMIS 4958x is New
Indication of synchronization with mains
Indicates if AMIS--49587 has received a valid configuration
Indication if PLC buffer is busy
Time slot counter
Alarm detection status
PLL lock status
Delta Electrical Phase
Minimum Delta Credit Value
Repeater Mode
Not Used
http://onsemi.com
34
REP[1:0]
AMIS--49587
7.2.2 Status Message in MASTER or CLIENT MODE:
STATUS MESSAGE IN SLAVE MODE
Structure
Byte
Content
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
1
Start
0
1
1
1
1
1
1
1
2
Data 1
x
x
x
x
x
Not SYNC
Not
SET
Buffer
BUSY
3
Data 2
x
x
x
ALARM
_EN
PLL
_LOCK
4
Data 3
TS_Nb[2:0]
InvalFrCnt[7:0]
Where:
Not SYNC
Not SET
Buffer BUSY
TS_Nb[2:0]
Alarm_EN
PLL_LOCK
InvalFrCnt[7:0]
x
Indication of synchronization with mains
Indicates if AMIS--49587 has received a valid configuration
Indication if PLC buffer is busy
Time slot counter
Alarm detection status
PLL lock status
Invalid Frame counter
Not Used
7.2.3 Status Message in MONITOR MODE:
STATUS MESSAGE IN SLAVE MODE
Structure
Byte
Content
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
1
Start
0
1
1
1
1
1
1
1
2
Data 1
x
x
x
x
x
Not SYNC
Not SET
Buffer
BUSY
3
Data 2
TS_Nb[2:0]
x
x
x
ALARM
_EN
PLL
_LOCK
4
Data 3
DEP[2:0]
x
x
x
x
x
Where:
Not SYNC
Not SET
Buffer BUSY
TS_Nb[2:0]
Alarm_EN
PLL_LOCK
DEP[2:0]
x
Indication of synchronization with mains
Indicates if AMIS--49587 has received a valid configuration
Indication if PLC buffer is busy
Time slot counter
Alarm detection status
PLL lock status
Delta Electrical Phase
Not Used
7.3 CONFIGURATION OF THE AMIS--49587
The serial port frame format is the same for RX and TX and is different from the status data frames.
Table 37. SERIAL PORT CONFIGURATION AND DATA PATH FRAME LAYOUT
<STX>
Length
Command
User_Data
http://onsemi.com
35
CHK
AMIS--49587
Table 38.
Field
Byte Length
Value
<STX>
1
02h
Description
Start of text delimiter
Length
1
03h .. 250
Length of the Command, User_Data fields and CHK.
Command
1
00h .. FEh
Command code
User_Data
0 .. 247
Byte String
Zero to 247 data bytes.
CHK
2
0000h .. 65535
The checksum of the local frame is the result of the addition of the
elements of the frame, from length up to the last UserData byte, or
up to the Command byte if there is no UserData byte. The CHK is
sent with LSB first.
Important: Frame in little endian format (LSByte first)
Table 39. SUMMARY OF FRAME DELIMITERS
Character
Definition
ASCII Code
<STX>
Start of text; first char of frame
02h
<ACK>
Acknowledgment
06h
<NAK>
Non Acknowledgment
15h
Start of Status Message
3Fh
<?>
Power On Reset
SET, Monitor
Validate Monitor Cfg
ResetRequest/reset
Validate Master Cfg
NOT SET
WriteConfigNew_Request/check config data
ResetRequest/reset
Reset
Reset
Validate Slave Cfg
Reset
Invalid Cfg
SET Slave
ResetRequest/reset
Figure 30. PLC MODEM State Diagram
http://onsemi.com
36
SET Master
AMIS--49587
Table 40. CONFIGURATION COMMANDS AND RESPONSES
Command
Unsolicited*
Initiator
Valid Command in Mode:
Code
Reset_Request
no
Application micro controller ()
Master / Slave / Monitor/ Not
Set
21h
WriteConfig_Request
no
Application micro controller
(Data_Config)
Master / Slave / Monitor/ Not
Set
71h
WriteConfig_Confirm
no
AMIS--49587 (Data_Config_Echo)
Master / Slave / Monitor/ Not
Set
72h
WriteConfig_Error
no
AMIS--49587 (Error_Code)
Master / Slave / Monitor/ Not
Set
73h
AccessDB_Request
no
Application micro controller
(DB_Data_Id)
Master / Slave
41h
AccessDB_Confirm
no
AMIS--49587 (DB_Data_Id_Echo)
Master / Slave
42h
AccessDB_Error
no
AMIS--49587 (Error_Code)
Master / Slave
43h
*An unsolicited message is a message that is originating from the AMIS--49587, based upon an AMIS--49587 internal event. The message
is not provoked by a prior command sent by the external processor.
The state diagram in Figure 30 shows how a PLC MODEM can be placed into one of the 4 main modes by issuing a
WriteConfig_Request message with accompanying configuration values. Most configuration parameters can be changed after
the MODEM is in a ‘set’ mode by the AccessDB_Request message. All settings can be undone by sending the Reset_Request
message.
7.3.1 Reset_Request
External CPU
AMIS4958x
Command
Interpreter
Reset_Request(0x21)
Mode is changed
to Not Set
Figure 31. Sequence Diagram for Reset_Request
Use the Reset_Request to bring the MODEM in a ‘NOT SET’ mode. No power line data transmission is possible; it is as
if the MODEM comes out of reset. The MODEM does only reply with the <ACK> (=0x06) character, no additional data is
sent from the MODEM.
<STX>
0x03 (Length)
0x21 (Reset_Request)
http://onsemi.com
37
CHK
AMIS--49587
7.3.2 WriteConfig_Request
External CPU
AMIS4958x
Command
Interpreter
WriteConfigNew_Request(0x71)
[Config data error| Command not allowed| Test mode]
WriteConfigNew_Error (0x73)
On success,
mode is changed
to Master, Slave
or Spy
[Config data OK&& Command allowed&& !Test mode]
WriteConfigNew_Confirm (0x72)
Figure 32. Sequence Diagram for WriteConfig_Request
Command can be issued at any time (If the status message allows it to be send) and will bring the MODEM in a ‘SET’ state
if the configuration data is correct. Depending on the configuration data, the final state of the MODEM will be Master, Slave
or Monitor.
<STX>
0x26 (Length)
0x71 (WriteConfig_Request)
Data_Config
CHK
With Data_Config, 36 bytes of configuration data as laid out in Tables 41 and 43.
Table 41. CONFIGURATION PARAMETERS
Field
Length
Value
First Initiator MAC Address (FIMA)
2 bytes
0001 to 0FFF
Last Initiator MAC Address (LIMA)
2 bytes
0001 to 0FFF
XXXX
XXXX
Local MAC Address
Active Initiator Address
2 bytes
2 bytes
Description
Slave: First value for Initiator MAC address
Master & Monitor: don’t care
Slave: Last value for Initiator MAC address
Master & Monitor: don’t care
0FFE or
Slave Mode: New
0001 to (FIMA--1)
FIMA to LIMA
Slave (Registered)
Master
XXXX
Monitor
0000
Master, Slave (unlocked)
FIMA to LIMA
XXXX
Slave (locked on an initiator)
Monitor
Time--out--synchro--confirm
2 bytes
0000 to FFFF
Slave: In seconds. (Not used in Master mode)
Time--out--frame--not--ok
2 bytes
0000 to FFFF
Slave: In seconds (Not used in Master mode)
Time--out--not--addressed
2 bytes
0000 to FFFF
Slave: In minutes (Not used in Master & Monitor mode)
XXXX
Monitor: Don’t care
Mac--group--addresses
10 bytes
0000 to 0FFF
Slave: 5 MAC group addresses (Not used in Master
mode)
Fs
2 bytes
0000 to FFFF
Step Register for the Space Frequency Fs
Fm
2 bytes
0000 to FFFF
Step Register for the Mark Frequency Fm
R_ZC_ADJUST
1 byte
00 to FF
http://onsemi.com
38
Value according to the voltage level of the 50 Hz
information for the input of the PLL.
AMIS--49587
Table 41. CONFIGURATION PARAMETERS
Field
Length
Value
4 bits
(b7 to b4)
XXXX
Number of repetitions of a Phy Alarm
0000
Disable Phy Alarm functionality
R_ALC_CTRL→Value
Max_Transmitting_Gain→Value
3 bits
(b3 to b1)
XXX
Attenuation value in fixed mode
R_ALC_CTRL→Value
Max_Transmitting_Gain→Mode
1 bit (b0)
0
Automatic level control
1
Fixed mode
R_CONF_TX_DATA_PRE_SLOT_SEL
1 bit (b7)
0
The output pin is the PRE_SLOT signal or Mode =
Master
1
The output pin is the transmitted DATA (for Radio)
This bit is not used (adjust length at 1 byte)
NbAlarm
Description
Pad
1 bit (b6)
0
R_CONF→MODE
3 bits
(b5 to b3)
001
Master mode for client station
010
Slave mode for server station
011
Monitor mode to spy and test of the DLC
communication
00
300 baud @ 50 Hz or 360 baud @ 60 Hz
01
600 baud @ 50 Hz or 720 baud @ 60 Hz
10
1200 baud @ 50 Hz or 1440 baud @ 60 Hz
11
2400 baud @ 50 Hz or 2880 baud @ 60 Hz
1 bit
(b0)
0
mains frequency = 50 Hz
1
mains frequency = 60 Hz
1 bit (b7)
0
This bit is not used (adjust length at 1 byte)
1 bit
(b6)
0
Method V6, favors FSK
1
Method V3, favors ASK
1 bit (b5)
0
Disabled
1
Enabled
Must be set to 0 (Synchronization on sub--frame
preamble)
R_CONF→BAUDRATE
R_CONF→MAINS_FREQ
Pad
Search method
SINC Filter
2 bits
(b2, b1)
SYNCHRO--Type→Mode
1 bit (b4)
0
SYNCHRO--Bit→Value
3 bits
(b3 to b1)
XXX
SYNCHRO--Bit→Mode
1 bit (b0)
1
Must be set to 1 (Fixed synchro bit)
SearchInitiatorGain or
Min--ReceivingGain Mode
1 bit (b7)
1
Search Initiator Gain selected
0
Min Receiving Gain selected
Search Initiator Gain or
Min--Receiving Gain
3 bits
(b6 to b4)
XXX
Value of the gain for Intelligent Synchronization or Min
Receiving Value Min Gain of reception = (value * 6 db)
Max--Receiving--Gain→Value
3 bits
(b3to b1)
XXX
Max Receiving gain value in limited mode Range of
reception = (value * 6 db)
Max--Receiving--Gain→Mode
1 bit (b0)
0
Non limited Max--Receiving--Gain
1
Limited Max--Receiving--Gain
0
Constant of 10 ms
1
5 characters depending on communication speed
0
Disables the transmitting of bad CRC frames
1
Enables the transmitting of bad CRC frames
X
Monitor: Don’t care
Time out Inter Character TIC
Bad CRC transmitting
1 bit (b7)
1 bit (b6)
http://onsemi.com
39
Synchro--bit value (in chip clock) in fixed mode
AMIS--49587
Table 41. CONFIGURATION PARAMETERS
Field
Pad correcting
FSK +
Length
Value
1 bit (b5)
0
Enables the Pad correcting
1
Disables the Pad correcting
X
Monitor: Don’t care
0
Disables the improvement of FSK
1
Enables the improvement of FSK
X
Slave and Monitor: Don’t care
0
Enables the Master Synchro
1
Disables the Master synchro
X
Slave and Monitor: Don’t care
0
disabled
1
Enabled
1 bit (b4)
Synchro Master
Synchro without Gain Min
1 bit (b3)
1 bit (b2)
Repeater
2 bits
(b1,b0)
Time--out--search--initiator
2 bytes
Description
X
Monitor: Don’t care
00
Never Repeater or Mode = Maste
01
Always Repeater
10
Not Repeater (accept frame ISACall)
11
Repeater (accept frame ISACall)
XX
Monitor: Don’t care
0 to FFFF
XXXX
In seconds
Master, Monitor: Don’t care
23. When a time--out is written with a 0x0000 value using either the WriteConfig_Request or the AccessDB_Request command, this time--out
will not be activated.
24. After a AccessDB_Request for either the Time--out--not--addressed or the Time--out--frame--not--ok, the new value is immediately taken in
account (the time--out is restarted) except when the local MAC address is NEW and the initiator MAC address is nobody.
25. The envelops are calculated using square root values or absolute values, depending on the baud rate and on the main frequency. The
following table describes the different modes:
300, 600, 1200 bps
2400 bps
50 Hz
60 Hz
50 Hz
60 Hz
Synchro
Square
Root
Square
Root
ABS
ABS
Reception
Square
Root
Square
Root
Square
Root
ABS
26. When FSK+ option is enabled, new thresholds are calculated. Than if the two envelops are under the threshold, the envelop which has the
smallest gap with his threshold is used to determinate which bit is received. Or, if the two envelops are over the threshold, the envelop which
has the biggest gap with his threshold is used.
7.3.3 WriteConfig_Confirm
<STX>
0x26 (Length)
0x72 (WriteConfig_Confirm)
Data_Config_Echo
CHK
When the complete set of configuration parameters has been evaluated and stored by the MODEM, it replies with success
and echoes the configuration data for the external processor to see if all parameters are correctly stored.
7.3.4 WriteConfig_Error
<STX>
0x04 (Length)
0x73 (WriteConfig_Error)
Error_Code, Table 43
CHK
An error is raised when the external processor issues a WriteConfig_Request command in which the fields listed in Table 42
are modified with respect to the previously issued WriteConfig_Request command. All other data fields of the
WriteConfig_Request may be changed.
http://onsemi.com
40
AMIS--49587
Table 42. NON CHANGEABLE PARAMETERS AFTER AMIS 49587 IS SET
Field
Length
Value
Description
1 bit (b7)
x
No action
3 bits (b5 to b3)
xxx
No action
2 bits (b2,b1)
xx
No action
1 bit (b0)
x
No action
R_CONF_TX_DATA_PRE_SLOT_SEL
R_CONF→MODE
R_CONF→BAUDRATE
R_CONF→MAINS_FREQ
Table 43. WriteConfig ERROR CODES
Error Identifier
Error_Code
ERR_UNAVAILABLE_MODE
21h
ERR_ILLEGAL_DATA_COMMAND
22h
ERR_ILLEGAL_LOCAL_MAC_ADR
23h
ERR_ILLEGAL_INITIATOR_MAC_ADR
24h
ERR_UNAVAILABLE_COMMAND
25h
7.3.5 AccessDB_Request
External CPU
AMIS49587
Command
Interpreter
AccessDB_Request (0x41)
[Data fields can’t be changed now]
AccessDB_Error (0x43)
[Data fields can be changed]
AccessDB_Confirm (0x42)
Figure 33. Sequence Diagram for AccessDB_Request
<STX>
0x07 + length of
data (Length)
0x41 (AccessDB_Request)
Data Field Identifier (Table44)
Data
CHK
Note that although the name of the AccessDB_Request command suggests only write operations are possible, there are
subcommands to read from the data base.
Each AccessDB_Request command is answered by the MODEM with either a AccessDB_Confirm or AccessDB_Error
frame.
For better readability, the AccessDB_Confirm frames and explanation are listed here and not grouped into a separate
chapter.
http://onsemi.com
41
AMIS--49587
Table 44. DATA BASE ENTRIES THAT MODIFY THE CONFIGURATION
Field Name
Ident
Description
FIMA/LIMA
0000
Changes the value of First Initiator MAC Address (FIMA) and Last Initiator MAC
Address (LIMA)
LocalMacAdd/InitMacAdd
0001
Changes the value of Local MAC
Address and Active Initiator Address
Time--out--synchro--confirm
0002
Changes the value of the TO synchro confirm (In seconds.)
Time--out--frame--not--ok
0003
Changes the value of the TO frame not ok (In seconds)
Time--out--not--addressed
0004
Changes the value of the TO not addressed (In minutes)
Mac--group--addresses
0005
Changes the value of the 5 MAC group addresses
Min--delta--credit
0007
Read the value of the Min delta credit and then set to 7
Max_Transmitting_Gain: Mode and Value
(R_ALC_CTRL)
0008
Changes the mode and the value of the max transmitting gain
SYNCHRO--Type:Mode
SYNCHRO--Bit:Value
0009
Changes sychro mode and the synchro bit value
Max--Receiving--Gain: Mode and Value
000A
Changes the mode and the value of the Max Receiving gain
Repeater
000B
Changes the repeater state
Frequency
000C
Changes the value of the frequencies Fs and Fm
Time--SearchInitiator
0011
Changes the value of the TO Search Initiator (In seconds)
ReadConfig
0012
To get an echo of the current configuration of the FPMA
Read SoftVersion
0013
Read the version of the FPMA
Min--ReceivingGain Value
0014
Changes the value of the Min Receiving Gain
Gain--SearchInitiator
0015
Changes the value of the Gain--SearchInitiator
7.3.5.1 FIMA/LIMA
This request is used to modify the value of the FIMA and LIMA addresses. The values of FIMA and LIMA must be in the
field 0001 to 0FFF, and must be compatible with current value of LocalMacAdd and InitMacAdd.
Request Format:
<STX>
0x09(Length)
0x41 (AccessDB_Request)
0x0000
FIMA (2 bytes), LIMA (2 bytes)
CHK
0x42 (AccessDB_Confirm)
0x0000
FIMA (2 bytes), LIMA (2 bytes)
CHK
Confirm Format:
<STX>
0x09(Length)
7.3.5.2 LocalMacAdd/InitMacAdd
This request is used to modify the value of the Local Mac Address and the Initiator Mac Address. The values of
LocalMacAdd and InitMacAdd must be in the field 0001 to 0FFF, and must be compatible with current value of FIMA and
LIMA.
Request Format:
<STX>
0x09(Length)
0x41 (AccessDB_Request)
0x0100
LocalMacAdd (2 bytes), InitMacAdd (2 bytes)
CHK
0x42 (AccessDB_Confirm)
0x0100
LocalMacAdd (2 bytes), InitMacAdd (2 bytes)
CHK
Confirm Format:
<STX>
0x09(Length)
7.3.5.3 TimeoutSynchro
This request is used to modify the value of the timeout synchro confirmation. The Timeout Synchro Confirm is set in
seconds.
Request Format:
<STX>
0x07(Length)
0x41 (AccessDB_Request)
0x0200
http://onsemi.com
42
TO Synchro Confirm (2 bytes)
CHK
AMIS--49587
Confirm Format:
<STX>
0x07(Length)
0x42 (AccessDB_Confirm)
0x0200
TO Synchro Confirm (2 bytes)
CHK
7.3.5.4 TimeoutNotOK
This request is used to modify the value of the timeout Frame Not OK. The Timeout Frame Not OK is set in seconds.
Request Format:
<STX>
0x07(Length)
0x41 (AccessDB_Request)
0x0300
TO Frame Not OK (2 bytes)
CHK
0x42 (AccessDB_Confirm)
0x0300
TO Frame Not OK (2 bytes)
CHK
Confirm Format:
<STX>
0x07(Length)
7.3.5.5 TimeoutNotAddressed
This request is used to modify the value of the timeout Not Addressed. The Timeout Not Addressed is set in minutes.
Request Format:
<STX>
0x07(Length)
0x41 (AccessDB_Request)
0x0400
TO Not Addressed (2 bytes)
CHK
0x42 (AccessDB_Confirm)
0x0400
TO Not Addressed (2 bytes)
CHK
Confirm Format:
<STX>
0x07(Length)
7.3.5.6 MacGroupAddress
This request is used to modify the values of the 5 Mac Group Addresses. The Mac Group Addresses must be in the field
LIMA(not included) to 0FFB.
If the first address of the 5 MacGroup addresses is set to 0xFFF, every frame with destination MAC address in the field
LIMA(not included) to 0FFB will be transmitted by the FPMA. This makes it possible to manage more than 5 MAC address
of group by the external micro controller.
Request Format:
<STX>
0x0E(Length)
0x41 (AccessDB_Request)
0x0500
Mac Group Addresses (5 *2 bytes)
CHK
Confirm Format:
<STX>
0x0E(Length)
0x42 (AccessDB_Confirm)
0x0500
Mac Group Addresses (5 *2 bytes)
CHK
7.3.5.7 Min Delta Credit
This request is used to read the Min Delta Credit in the AMIS--49587. Once the request sent to the AMIS--49587, the Min
Delta Credit is automatically set to 7. The AMIS--49587 answers with the value of the Min Delta Credit (before it was set to
7).
Request Format:
<STX>
0x05(Length)
0x41 (AccessDB_Request)
0x0700
CHK
Confirm Format:
<STX>
0x06(Length)
0x42 (AccessDB_Confirm)
0x0700
Min Delta Credit (1 byte)
CHK
7.3.5.8 MaxTransmittingGain
This request is used to modify the Max Transmitting Gain of the AMIS--49587. The Max Transmitting Gain can be reduced
from 0 to 21 dB by step of step 3 dB. The data value for the request is in the field 01 to 0F by step of 2, it indicates an attenuation
of ((N -- 1) / 2) dB. The data value for the Confirm is in the field 00 to 07, indicating an attenuation of N * 3 dB.
Request Format:
<STX>
0x06(Length)
0x41 (AccessDB_Request)
0x0800
Transmitting Attenuation (1 byte)
CHK
0x42 (AccessDB_Confirm)
0x0800
Transmitting Attenuation (1 byte)
CHK
Confirm Format:
<STX>
0x06(Length)
http://onsemi.com
43
AMIS--49587
7.3.5.9 MaxReceivingGain
This request is used to modify the Max Receiving Gain of the AMIS--49587. The Max Receiving Gain can be set from 1
to 42 dB by step of step 6 dB, or unlimited. The data value for the request is in the field 01 to 0F by step of 2, it indicates a
Max Receiving Gain of ((N -- 1) / 2) * 6 dB; or 00, which indicates an unlimited Max Receiving Gain. The data value for the
Confirm is in the field 00 to 07, indicating a Max Receiving Gain of (N * 6) dB, or 08, which indicates an unlimited Max
Receiving Gain.
Request Format:
<STX>
0x06(Length)
0x41 (AccessDB_Request)
0x0A00
Max Receiving Gain (1 byte)
CHK
42h (AccessDB_Confirm)
0x0A00
Max Receiving Gain (1 byte)
CHK
Confirm Format:
<STX>
0x06(Length)
7.3.5.10 Repeater
This request is used to modify the repeater state of the AMIS--49587. The repeater state can be
Repeater:
0x00
No Repeater:
0x01
Request Format:
<STX>
0x06(Length)
0x41 (AccessDB_Request)
0x0B00
Repeater State (1 byte)
CHK
0x42 (AccessDB_Confirm)
0x0B00
Repeater State (1 byte)
CHK
Confirm Format:
<STX>
0x06(Length)
7.3.5.11 Frequency
This request is used to modify the values of the frequencies Fs and Fm used for the PLC communication. To calculate the
value of the data field, read paragraph Sine Wave generator.
Request Format:
<STX>
0x09(Length)
0x41 (AccessDB_Request)
0x0C00
Fs (2 bytes), Fm (2 bytes)
CHK
0x42 (AccessDB_Confirm)
0x0C00
Fs (2 bytes), Fm (2 bytes)
CHK
Confirm Format:
<STX>
0x09(Length)
7.3.5.12 TimeoutSearchInitiator
This request is used to modify the value of the timeout Search Initiator. The timeout Search Initiator is set in seconds.
Request Format:
<STX>
0x07(Length)
0x41 (AccessDB_Request)
0x1100
TO Search Initiator (2 bytes)
CHK
0x42 (AccessDB_Confirm)
0x1100
TO Search Initiator (2 bytes)
CHK
Confirm Format:
<STX>
0x07(Length)
7.3.5.13 ReadConfig
This request is used to get an echo of the configuration of the AMIS--49587.
Request Format:
<STX>
0x05(Length)
0x41 (AccessDB_Request)
0x1200
CHK
Confirm Format:
<STX>
0x29(Length)
0x42 (AccessDB_Confirm)
0x1200
Current configuration (36 bytes)
CHK
7.3.5.14 Read Version Soft
This request is used to read the soft version of the AMIS--49587.
Request Format:
<STX>
0x05(Length)
0x41 (AccessDB_Request)
http://onsemi.com
44
0x1300
CHK
AMIS--49587
Confirm Format:
<STX>
0x06(Length)
0x42 (AccessDB_Confirm)
0x1300
Soft Version (1 byte)
CHK
7.3.5.15 Min- ReceivingGain
This request is used to modify the Min Receiving Gain of the AMIS--49587. The Min Receiving Gain can be set from 1 to
42 dB by step of step 6 dB, or unlimited. The data value for the request is in the field 01 to 0F by step of 2, it indicates a Min
Receiving Gain of ((N -- 1) / 2) * 6 dB; or 00, which indicates that the Min Receiving Gain is not used. The data value for the
Confirm is in the field 00 to 07, indicating a Min Receiving Gain of (N * 6) dB, or 08, which indicates an unlimited Max
Receiving Gain.
Request Format:
<STX>
0x06(Length)
0x41 (AccessDB_Request)
0x1400
Min Receiving Gain (1 byte)
CHK
0x42 (AccessDB_Confirm)
0x1400
Min Receiving Gain (1 byte)
CHK
0x41 (AccessDB_Request)
0x1500
Gain Search Initiator (1 byte)
CHK
0x42 (AccessDB_Confirm)
0x1500
Gain Search Initiator (1 byte)
CHK
Confirm Format:
<STX>
0x06(Length)
7.3.5.16 Gain Search Initiator
This request is used to modify the value of the Gain Search Initiator.
Request Format:
<STX>
0x06(Length)
Confirm Format:
<STX>
0x06(Length)
7.3.6 AccessDB_Confirm
Like already described in AccessDB_Request, on success the MODEM answers with a AccessDB_Confirm frame.
Frame Format:
<STX>
Length
0x42 (AccessDB_Confirm)
DB_Data_Id_Echo
CHK
7.3.7 AccessDB_Error
If any error occurs during AccessDB_Request, the MODEM answers with a AccessDB_Error frame.
Frame Format:
<STX>
Length
0x43 (AccessDB_Error)
Error_Code
Table 45. AccessDB_Request ERROR CODES
Error Identifier
Error_Code
ERR_UNAVAILABLE_RESOURCE
0x11
ERR_REQUEST_NOT_ALLOWED
0x12
ERR_UNAVAILABLE_MODE
0x21
ERR_ILLEGAL_DATA_COMMAND
0x22
ERR_ILLEGAL_LOCAL_MAC_ADR
0x23
ERR_ILLEGAL_INITIATOR_MAC_ADR
0x24
ERR_UNAVAILABLE_COMMAND
0x25
http://onsemi.com
45
CHK
AMIS--49587
7.4 SEND AND RECEIVE NETWORK DATA WITH
Note that IEC 61334--5--1 specifies that the maximum
length of a MAC layer frame is only 38 bytes. The
maximum number of bytes that the AMIS--49587 accepts in
one transmit command is 242 bytes. The AMIS--49587
takes care of splitting these 242 bytes in smaller chunks,
encapsulate them in correct frames and send them over the
power line.
The “Frame Indicator” and the “Number of the subframe”
fields are omitted when the MAC frame is sent to the
external processor since they don’t contain useful
information to the LLC layer.
THE AMIS--49587
The data path should be implemented like specified in
IEC 61334--5--1. The MAC layer is implemented by the
AMIS--49587, the LLC layer should be implemented by the
external processor (See Figure 29).
Figure 34 shows how a complete frame like it shows up
on the power line (Physical Layer Frame) is composed of a
MAC Layer Frame, taken care of by the AMIS--49587,
encapsulating a LLC Layer Frame that should be provided
by the external processors LLC layer.
Physical Layer Frame
MAC Layer Frame
LCC Layer Frame
Preamble
0xAAAA
Delimiter
0x54C7
Frame indicator
16 bit
Initial
Credit
3 bit
# Subframes
16 bit
Current
Credit
3 bit
Header
56 bit
Delta
Credit
3 bit
M_SDU
208 bit
Source Address
12 bit
Destination Address
12 bit
PAD
# bit as needed
FCS
24 bit
Pad Length
8 bit
Figure 34. Power Line Data Frame Structure (IEC 61334--5--1)
Table 46. DATA PATH COMMANDS AND RESPONSES
Command
Unsolicited*
Initiator
Valid Command in Mode:
Code
MA_DATA_Indication
√
AMIS--49587 (MAC_Frame)
Master / Slave
50h
MA_DATA_Request
no
Application micro controller (MAC_Frame)
Master / Slave
51h
MA_DATA_Confirm
no
AMIS--49587 (Transmission_Status)
Master / Slave
52h
MA_DATA_Indication_Bad_CRC
√
AMIS--49587 (MAC_Frame)
Master / Slave
53h
ISA_Request
no
Application micro controller (Data_ISA)
Master / Slave
61h
ISA_Confirm
no
AMIS--49587 (Transmission_Status)
Master / Slave
62h
SPY_No_SubFrame
√
AMIS--49587 (SpyData)
Monitor
A0h
SPY_SubFrame
√
AMIS--49587 (SpyData, PHY_sdu)
Monitor
B0h
SPY_Search_Synchro
√
AMIS--49587 ()
Monitor
C0h
SPY_Synchro_Found
√
AMIS--49587 (SpyData)
Monitor
D0h
Spy_Alarm_Found
√
AMIS--49587 (SpyData, AlarmPattern)
Monitor
F0h
Spy_No_Alarm_Found
√
AMIS--49587 (SpyData, AlarmPattern)
Monitor
E0h
Synchro_Indication
√
AMIS--49587 (Synchro_Data)
Master / Slave
10h
Desynchro_Request
no
Application micro controller ()
Master / Slave / Monitor
11h
AccessDB_Request
no
Application micro controller (DB_Data_Id)
Master / Slave
41h
AccessDB_Confirm
no
AMIS--49587 (DB_Data_Id_Echo)
Master / Slave
42h
AccessDB_Error
no
AMIS--49587 (Error_Code)
Master / Slave
43h
*An unsolicited message is a message that is originating from the AMIS--49587, based upon an AMIS--49587 internal event. The message is
not provoked by a prior command sent by the external processor.
http://onsemi.com
46
AMIS--49587
7.4.1 MA_DATA_Indication
External CPU
AMIS4958x
Command
Interpreter
AMIS4958x
Phy MAC layer
Received data OK
MA_DATA_Indicator(0x50)
Figure 35. Sequence Diagram for MA_DATA_Indication
The MA_Data_Indication is sent from the AMIS--49587 (Client or Server) to the external controller to deliver the received
DLC frame.
Frame Format:
<STX>
Length
MA_Data_Indication >
MAC_Frame
CHK
7.4.2 MA_DATA_Request
External CPU
AMIS4958x
Command
Interpreter
AMIS4958x
Phy MAC layer
MA_DATA_Request(0x51)
MA_SendData
Send OK
MA_DATA _Confirm(0x52)
With status success
Send NOK
MA_DATA _Confirm(0x52)
With status fail
Figure 36. Sequence Diagram for MA_DATA_Request
The MA_Data_Request is sent from the external controller LLC layer to the AMIS--49587 local MAC sub--layer to request
a DLC frame transmission. This request must be received by the AMIS--49587 in the time--slot preceding the
transmitting one.
When the AMIS--49587 receives in the same time (same time--slot) an MA_Data_Request from the external controller and
a frame made up of one sub--frame with a repetition credit at zero from the mains, it ignores the frame received from the mains.
In all other conflict cases, it refuses the application micro controller request.
Frame Format:
<STX>
Length
0x51 (MA_Data_Request)
http://onsemi.com
47
MAC_Frame
CHK
AMIS--49587
Table 47. DESCRIPTION OF THE MAC_Frame FIELD
Field Name
Length
Value
Initial Credit
3 bits b7--b5
0h to 7h
Initial Credit
Current Credit
3 bits b4--b2
0h to 7h
Current Credit = Initial Credit
Delta Credit
2 bits b1,b0
0h to 3h
Delta Credit is Received Delta Credit for Slave mode and 0 for
Master mode
12 bits b23--b12
Not used
Slave Mode (Filled by MAC layer)
Source Address
Destination Address
000h to FFFh
Master Mode
12 bits b11--b0
000h to FFFh
Destination MAC address of the target station DLC
1 byte
Not used
Pad length
M_sdu
Description
Filled by MAC layer
up to 242 bytes
MAC service data unit, the application data from the LLC layer
implemented in the external processor.
7.4.3 MA_DATA_Confirm
frame transmission on the mains and before the beginning
of the repetition (if the credit is higher than zero). The
Transmission_Status byte contains a value corresponding at
this positive or negative acknowledgment. The different
values for the Transmission_Status field are described
Table 48.
The MA_DATA_Confirm is sent from AMIS--49587 to a
external controller (SLAVE or MASTER) either as positive
acknowledgment when a MA_DATA_Request has
successfully been transmitted by the physical layer, or as
negative acknowledgment when the transmission has been
refused. The positive acknowledgment is sent after the
Table 48. TRANSMISSION STATUS
Field Name
Value
Description
OK
FFh
No error has been found
LM_TU1
00h
MA Data Confirm NEG
Resources Temporary Unavailable at the MAC sub--layer
LM_SE
03h
Syntax Error at the MAC sub--layer
LM_TU2
0Ah
Command not authorized or Asic is not synchronized on the mains
LM_TU3
14h
PLC buffer not free or Asic is busy
Resources Temporary Unavailable at the MAC sub--layer
LM_TU4
1Eh
PLC buffer not free or Asic is busy
Resources Temporary Unavailable at the MAC sub--layer
Frame Format:
<STX>
Length
0x52 (MA_Data_Confirm)
Transmission_Status
CHK
7.4.4 MA_DATA_Indication_Bad_CRC
The MA_Data_Indication_Bad_CRC is sent from the AMIS--49587 (Client or Server) to the external micro controller to
deliver an erroneous frame. This command is only used if the Bad CRC transmitting option is chosen during the configuration.
The frame with errors can be used by the external controller to analyze the faults.
Frame Format:
<STX>
Length
0x53 (MA_Data_Indication_Bad_CRC)
MAC_Frame
CHK
7.4.5 SPY_No_SubFrame
The SPY_No_SubFrame is sent by the AMIS--49587 local PHY layer to indicate that a sub--frame has not been received
correctly, due to either a method not found, or a non recognition of the Start Sub--frame Delimiter (SSD).
Frame Format:
<STX>
Length
0xA0 (SPY_No_SubFrame)
http://onsemi.com
48
SpyData
CHK
AMIS--49587
Table 49. DESCRIPTION OF THE SpyData FIELD
Field Name
Length
Description
S0
2 Bytes
Value of the zero signal envelope
N0
2 Bytes
Value of the zero noise envelope
S1
2 Bytes
Value of the one signal envelope
N1
2 Bytes
Value of the one noise envelope
Threshold
2 Bytes
Indicates the threshold value for ASK method or the FSK factor.
Method
1 Byte
Indicates the found method:
0 ⇒ No method
1 ⇒ ASK0
2 ⇒ ASK1
3 ⇒ FSK (S0 ≅ S1)
4 ⇒ FSK0 (S0 > S1)
5 ⇒ FSK1 (S1 > S0)
PAD
1 Bit (b7)
0
Synchro_bit Value
3 Bits
(b6,b5,b4)
Synchronization bit value when synchronization was found
PAD
1 Bit (b3)
0
Reception Gain
3 Bits
(b2,b1,b0)
Indicates the gain value (0 to 7) used during the synchronization
7.4.6 SPY_SubFrame
The SPY_SubFrame is sent by the AMIS--49587 local PHY layer to indicate that a sub--frame has been correctly received.
All information concerning the reception conditions (SpyData) and the data (PHY_sdu) are supplied in this command. For
the format of the SpyData field, see Table 49.
Frame Format:
<STX>
Length
0xB0 (Spy_SubFrame)
SpyData Field, PHY_sdu
CHK
7.4.7 SPY_Search_Synchro
The SPY_Search_Synchro is sent periodically by the AMIS--49587 local MAC sub--layer to indicate synchronization is in
progress.
Frame Format:
<STX>
Length
0xC0 (Spy_Search_Synchro)
CHK
7.4.8 SPY_Synchro_Found
The SPY_Synchro_Found is sent by the AMIS--49587 local MAC sub--layer as soon as it has correctly found
synchronization when it was receiving a sub--frame. Thus, it is now synchronized and it is waiting for another correct frame
for confirmation.
For the format of the SpyData field, see Table 49.
Frame Format:
<STX>
Length
0xD0 (Spy_ Synchro_Found)
SpyData
CHK
7.4.9 Spy_Alarm_Found
The SPY_No_Alarm_Found is sent by the AMIS--49587 local MAC sub--layer at the end of a time--slot, when it has not
found an Alarm indication in the pause time.
For the format of the SpyData field, see Table 49.
The AlarmPattern has a length of 2 bytes.
Frame Format:
<STX>
Length
0xF0 (SPY_ No_Alarm_Found)
http://onsemi.com
49
SpyData, AlarmPattern
CHK
AMIS--49587
7.4.10 Spy_No_Alarm_Found
The SPY_Alarm_Found is sent by the AMIS--49587 local MAC sub--layer as soon as it has correctly found a Alarm
indication in the pause time.
For the format of the SpyData field, see Table 49.
The AlarmPattern has a length of 2 bytes.
Frame Format:
<STX>
Length
0xE0 (SPY__Alarm_Found)
SpyData, AlarmPattern
CHK
7.4.11 Synchro_Indication
External CPU
AMIS4958x
Command
Interpreter
SLAVE ONLY
Synchro_Indication(0x10)
Figure 37. Sequence Diagram for Synchro_Indication
The Synchro_Indication is sent by the AMIS--49587 in order to indicate that something has changed in the synchronization
state. The field Synchro_Data contains the change reason and data corresponding with this change.
Frame Format:
<STX>
Length
0x10 (Synchro_Indication)
http://onsemi.com
50
Synchro_Data
CHK
AMIS--49587
The Synchro_Data field contains a synchronization event description of 1 or 2 bytes with accompanying data.
Table 50. Synchro_Data FIELDS
Event Description, byte 1
Event Description, byte 2
Length and Synchro_data Description
Remark
1 byte: Pad
2 bytes: Signal S0
2 bytes: Noise N0
2 bytes: Signal S1
2 bytes: Noise N1
2 bytes: ASK Threshold or FSK factor
1 byte : Method
1 byte : Synchro--Bit and Gain values
0x01
Synchronization Found
1 byte: Pad
2 bytes: Source MAC Address
2 bytes: Destination MAC Address
0x02
Synchronization Confirmed
0x04
0x01
Synchronization Lost
Time--out not addressed has
expired
0x04
0x02
Synchronization Lost
Time--out frame not OK has
expired
0x04
0x03
Synchronization Lost
Time--out synchro confirm has
expired
0x04
0x04
Synchronization Lost
Addressed by a wrong initiator
0x04
0x05
Synchronization Lost
External desynchro command
0x04
0x06
Synchronization Lost
Search Initiator active
2 bytes: Local MAC Add
2 bytes: Initiator MAC Add
Slave mode
2 bytes: Local MAC Add
2 bytes: Initiator MAC Add
Master and Slave
mode
2 bytes: Local MAC Add
2 bytes: Initiator MAC Add
Master and Slave
mode
2 bytes: Source MAC Add
2 bytes: Dest. MAC Add
Slave mode
2 bytes: Local MAC Add
2 bytes: Initiator MAC Add
Master and Slave
mode
2 bytes: Last initiator MAC Address received
2 bytes: Current initiator MAC Address
choice
Slave mode
7.4.12 Desynchro_Request
External CPU
AMIS4958x
Command
Interpreter
SLAVE ONLY
DeSynchro_request(0x11)
Figure 38. Sequence Diagram for DeSynchro_Request
The Desynchro_Request command is used by the external controller to enforce the not synchronized state in the
AMIS--49587 and therefore it starts looking for a new synchronization.
Frame Format:
<STX>
0x03 (Length)
0x11 (Desynchro_Request)
7.4.13 AccessDB_Request
Field Name
PhyAlarmRequest
Ident
000F
Description
Request the transmission of a Phy Alarm
http://onsemi.com
51
CHK
AMIS--49587
7.4.13.1 PhyAlarmRequest
Description:
This request is used to send a physical alarm pattern. No data is transmitted to indicate the number of repetitions, the
AMIS--49587 already knows this number because it is in its set of configuration data.
Request Format:
<STX>
0x05(Length)
0x41 (AccessDB_Request)
0x0F00
CHK
Confirm Format:
<STX>
0x06(Length)
0x42 (AccessDB_Confirm)
0F00h
Number of alarm Transmissions (1 byte)
CHK
7.4.14 AccessDB_Confirm
See paragraph AccessDB_Confirm.
7.4.15 AccessDB_Error
See paragraph AccessDB_Error.
7.5 RETRIEVE STATISTICAL DATA FROM THE AMIS--49587
Table 51. STATISTICS COMMAND AND RESPONSES
Command
Unsolicited*
Initiator
Valid Command in Mode:
Code
AccessDB_Request
no
Application micro controller
(DB_Data_Id)
Master / Slave
41h
AccessDB_Confirm
no
AMIS--49587 (DB_Data_Id_Echo)
Master / Slave
42h
AccessDB_Error
no
AMIS--49587 (Error_Code)
Master / Slave
43h
*An unsolicited message is a message that is originating from the AMIS--49587, based upon an AMIS--49587 internal event. The message is
not provoked by a prior command sent by the external processor.
7.5.1 AccessDB_Request
The AccessDB_Request command can be used to read data path statistical information from the AMIS--49587.
Like in all other AccessDB_Request commands, the specific identifier of the data that is to be read needs to be provided:
Field Name
Identifier
Description
Invalid--frame--counter
0x0006
Read the value of the invalid--frame counter and then set to 0
Counters
0x000D
Read the value of the data counters:Counter Crc Ok, Counter Crc Not Ok,
Repeater counter, Transmit counter, corrected frames counter, and then
set to 0 or not
DataStats
0x0010
Read the value of the Data statistics, and then set to 0 or not.
7.5.1.1 Invalid Frame Counter
This request is used to read the Invalid Frame Counter of the AMIS--49587. Once the request sent to the AMIS--49587, the
Invalid Frame counter is automatically set to 0. The AMIS--49587 answers with the value of the Invalid Frame Counter
Request Format:
<STX>
0x05(Length)
0x41 (AccessDB_Request)
0x0600
CHK
Confirm Format:
<STX>
0x06(Length)
0x42 (AccessDB_Confirm)
0x0600
http://onsemi.com
52
Invalid Frame Counter (1 byte)
CHK
AMIS--49587
7.5.1.2 Data Counters
The Data Counters request is used to read the value of the data counters in the AMIS--49587. It contains one byte which
is used to know whether the counters must be reset or not (00: no reset, 01: reset) after reading them out.
There are 6 counters coded on 4 bytes each, which indicates:
1. number of CRC OK frames received
2. number of CRC not OK frames received
3. number of repeated frames
4. number of transmitted frames
5. number of corrected frames (with option Pad Correcting)
6. number of frames with bad Frame Indicator received
Request Format:
<STX>
0x06(Length)
0x41 (AccessDB_Request)
0x0D00
Request Counters (1 byte)
CHK
0x42 (AccessDB_Confirm)
0x0D00
CRC_OK (4 bytes), CRC_NOK (4 bytes),
Rep_Frames (4 bytes), Tr_Frames (4 bytes),
Corr_Frames (4 bytes), FI_NOK (4 bytes)
CHK
Confirm Format:
<STX>
0x1D(Length)
7.5.1.3 DataStats
The DataStats request is used to read the value of the current data statistics in the AMIS--49587. The request contains one
byte which is used to know whether the counters must be reset or not (00: no reset, 01: reset) after reading them out.
If the AMIS--49587 is synchronized the counters consist of 30 bytes:
1. The value of signal and noise (S0, N0, S1, N1) for the last subframe received (4 * 2 bytes) + the method and gain
used to demodulate this subframe (2 * 1 byte)
2. The method, gain and SNR (S0/N0, S1/N1) on the 5 last time slots in reception mode (5 * 4 bytes) + 1 byte to know
the actual position in the table
If the AMIS--49587 is not synchronized the counters consist of 36 bytes:
1. The values of the real and imaginary parts of the signal for each frequency (I0, Q0, I1, Q1),
2. for the 4 last calculated time--slots (4 * (4 * 2 bytes) )
3. The current position in the board (1 byte)
4. The software reception gain (1 byte)
5. The hardware reception gain (1 byte)
6. The R_ALC value (1 byte)
Request Format:
<STX>
0x06(Length)
0x41 (AccessDB_Request)
0x1000
Reset Counters (1 byte)
CHK
0x1000
Signal_noise_subframe (10 bytes),
SNRreception (20 bytes)
CHK
0x1000
I0,I1,Q1 (32 bytes), Pos (1 byte), GainSoft
(1 byte), GainHard (1 byte), R_ALC (1 byte)
CHK
Confirm Format:
If the AMIS--49587 is synchronized:
<STX>
0x23(Length)
0x42 (AccessDB_Confirm)
If the AMIS--49587 is not synchronized:
<STX>
0x29(Length)
0x42 (AccessDB_Confirm)
7.5.2 AccessDB_Confirm
See paragraph AccessDB_Confirm.
7.5.3 AccessDB_Error
See paragraph AccessDB_Error.
http://onsemi.com
53
AMIS--49587
PACKAGE DIMENSIONS
PLCC 28 LEAD
CASE 776AA--01
ISSUE O
http://onsemi.com
54
AMIS--49587
PACKAGE DIMENSIONS
QFN52 8x8, 0.5P
CASE 485M--01
ISSUE B
D
A
NOTES:
1. DIMENSIONING AND TOLERANCING
PER ASME Y14.5M, 1994.
2. CONTROLLING DIMENSION:
MILLIMETERS
3. DIMENSION b APPLIES TO PLATED
TERMINAL AND IS MEASURED
BETWEEN 0.25 AND 0.30 MM FROM
TERMINAL.
4. COPLANARITY APPLIES TO THE
EXPOSED PAD AS WELL AS THE
TERMINALS.
B
PIN ONE
REFERENCE
E
DIM
A
A1
A2
A3
b
D
D2
E
E2
e
K
L
2X
0.15
C
2X
0.15 C
A2
0.10 C
A
0.08 C
SEATING PLANE
A3
A1
MILLIMETERS
MIN
MAX
0.80
1.00
0.00
0.05
0.60
0.80
0.20 REF
0.18
0.30
8.00 BSC
6.50
6.80
8.00 BSC
6.50
6.80
0.50 BSC
0.20
-----0.30
0.50
REF
C
D2
14
52 X
L
26
27
13
E2
39
1
52 X
K
52
40
e
52 X
b
NOTE 3
0.10 C A B
0.05 C
ON Semiconductor and
are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice
to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability
arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages.
“Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All
operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. SCILLC does not convey any license under its patent
rights nor the rights of others. SCILLC products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other
applications intended to support or sustain life, or for any other application in which the failure of the SCILLC product could create a situation where personal injury or death may occur.
Should Buyer purchase or use SCILLC products for any such unintended or unauthorized application, Buyer shall indemnify and hold SCILLC and its officers, employees, subsidiaries,
affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury
or death associated with such unintended or unauthorized use, even if such claim alleges that SCILLC was negligent regarding the design or manufacture of the part. SCILLC is an
Equal Opportunity/Affirmative Action Employer. This literature is subject to all applicable copyright laws and is not for resale in any manner.
PUBLICATION ORDERING INFORMATION
LITERATURE FULFILLMENT:
Literature Distribution Center for ON Semiconductor
P.O. Box 5163, Denver, Colorado 80217 USA
Phone: 303--675--2175 or 800--344--3860 Toll Free USA/Canada
Fax: 303--675--2176 or 800--344--3867 Toll Free USA/Canada
Email: [email protected]
N. American Technical Support: 800--282--9855 Toll Free
USA/Canada
Europe, Middle East and Africa Technical Support:
Phone: 421 33 790 2910
Japan Customer Focus Center
Phone: 81--3--5773--3850
http://onsemi.com
55
ON Semiconductor Website: www.onsemi.com
Order Literature: http://www.onsemi.com/orderlit
For additional information, please contact your local
Sales Representative
AMIS--49587/D