AQ-R RELAYS AQ-R SOLID STATE RELAY UL File No.: E43149 CSA File No.: LR49089M14 • Two types of terminal shape: Plug-in terminal and Screw terminal Plug-in terminal (output side): #250 (input side): #110 • Flat type of SSR realized by aluminium printed circuit board Plug-in terminal: height max. 15 mm .591 inch Screw terminal: height max. 17 mm .669 inch • High dielectric strength: 1500 V AC (between input and output) • Heat sink and DIN mounting rail are available as accessories TYPES Plug-in terminal type Type Load voltage 75 to 125 V AC Zero-cross 10 A 75 to 250 V AC 75 to 125 V AC Zero-cross 15 A 75 to 250 V AC 75 to 125 V AC Zero-cross 20 A 75 to 250 V AC APPLICATIONS • Photocopiers • Air conditioners • Vending machines • Machine tools Screw-terminal type Input voltage 4 to 6 V DC 10 to 18 V DC 18 to 28 V DC 4 to 6 V DC 10 to 18 V DC 18 to 28 V DC 4 to 6 V DC 10 to 18 V DC 18 to 28 V DC 4 to 6 V DC 10 to 18 V DC 18 to 28 V DC 4 to 6 V DC 10 to 18 V DC 18 to 28 V DC 4 to 6 V DC 10 to 18 V DC 18 to 28 V DC Part No. AQR10A1-Z4/6VDC AQR10A1-Z10/18VDC AQR10A1-Z18/28VDC AQR10A2-Z4/6VDC AQR10A2-Z10/18VDC AQR10A2-Z18/28VDC AQR15A1-Z4/6VDC AQR15A1-Z10/18VDC AQR15A1-Z18/28VDC AQR15A2-Z4/6VDC AQR15A2-Z10/18VDC AQR15A2-Z18/28VDC AQR20A1-Z4/6VDC AQR20A1-Z10/18VDC AQR20A1-Z18/28VDC AQR20A2-Z4/6VDC AQR20A2-Z10/18VDC AQR20A2-Z18/28VDC Load voltage Type 75 to 125 V AC Zero-cross 10 A 75 to 250 V AC 75 to 125 V AC Zero-cross 15 A 75 to 250 V AC 75 to 125 V AC Zero-cross 20 A 75 to 250 V AC Input voltage 4 to 6 V DC 10 to 18 V DC 18 to 28 V DC 4 to 6 V DC 10 to 18 V DC 18 to 28 V DC 4 to 6 V DC 10 to 18 V DC 18 to 28 V DC 4 to 6 V DC 10 to 18 V DC 18 to 28 V DC 4 to 6 V DC 10 to 18 V DC 18 to 28 V DC 4 to 6 V DC 10 to 18 V DC 18 to 28 V DC Part No. AQR10A1-S-Z4/6VDC AQR10A1-S-Z10/18VDC AQR10A1-S-Z18/28VDC AQR10A2-S-Z4/6VDC AQR10A2-S-Z10/18VDC AQR10A2-S-Z18/28VDC AQR15A1-S-Z4/6VDC AQR15A1-S-Z10/18VDC AQR15A1-S-Z18/28VDC AQR15A2-S-Z4/6VDC AQR15A2-S-Z10/18VDC AQR15A2-S-Z18/28VDC AQR20A1-S-Z4/6VDC AQR20A1-S-Z10/18VDC AQR20A1-S-Z18/28VDC AQR20A2-S-Z4/6VDC AQR20A2-S-Z10/18VDC AQR20A2-S-Z18/28VDC ORDERING INFORMATION Ex. AQR 10A 1 S Z 4/6VDC Load current Load voltage Terminal shape Type Input voltage 10 A, 15 A, 20 A 1: 75 to 125 V AC 2: 75 to 250 V AC Nil: Plug-in terminal S: Screw terminal Z: Zero-cross Z: type 4/6, 10/18, 18/28 V DC SPECIFICATIONS Ratings (at 20°C 68°F, Input ripple: 1% or less) 10 A type Part No. AQR10A1-Z AQR10A1-Z AQR10A1-Z AQR10A2-Z AQR10A2-Z AQR10A2-Z 4/6VDC 10/18VDC 18/28VDC 4/6VDC 10/18VDC 18/28VDC Remarks AQR10A1-S-Z AQR10A1-S-Z AQR10A1-S-Z AQR10A2-S-Z AQR10A2-S-Z AQR10A2-S-Z Items 4/6VDC 10/18VDC 18/28VDC 4/6VDC 10/18VDC 18/28VDC 4 to 6 V DC 10 to 18 V DC 18 to 28 V DC 4 to 6 V DC 10 to 18 V DC 18 to 28 V DC Input voltage Input Input impedance Approx. 0.26 kΩ Approx. 0.86 kΩ Approx. 1.36 kΩ Approx. 0.26 kΩ Approx. 0.86 kΩ Approx. 1.36 kΩ side Drop-out voltage, 1V min. Max. load current 10 A See “DATA 1” Load voltage 75 to 125 V AC 75 to 250 V AC Frequency 45 to 65 Hz Repetitive peak 400 V 600 V voltage Non-repetitive In one cycle at Load 100 A surge current 60 Hz side Max. “OFF-state” 2.5 mA (when 100 V AC applied) 5 mA (when 200 V AC applied) at 60 Hz leakage current Max. “ON-state” at max. 1.6 V voltage drop carrying current Min. load current 100 mA OFF-state dV/dt 100 V/µs 15 A type Part No. AQR15A1-Z AQR15A1-Z AQR15A1-Z AQR15A2-Z AQR15A2-Z AQR15A2-Z 4/6VDC 10/18VDC 18/28VDC 4/6VDC 10/18VDC 18/28VDC Remarks AQR15A1-S-Z AQR15A1-S-Z AQR15A1-S-Z AQR15A2-S-Z AQR15A2-S-Z AQR15A2-S-Z Items 4/6VDC 10/18VDC 18/28VDC 4/6VDC 10/18VDC 18/28VDC 4 to 6 V DC 10 to 18 V DC 18 to 28 V DC 4 to 6 V DC Input voltage 10 to 18 V DC 18 to 28 V DC Input Input impedance Approx. 0.26 kΩ Approx. 0.86 kΩ Approx. 1.36 kΩ Approx. 0.26 kΩ Approx. 0.86 kΩ Approx. 1.36 kΩ side Drop-out voltage, 1V min. Max. load current 15 A See “DATA 1” Load voltage 75 to 125 V AC 75 to 250 V AC Frequency 45 to 65 Hz Repetitive peak 400 V 600 V voltage In one cycle at Load Non-repetitive 150 A 60 Hz side surge current Max. “OFF-state” 2.5 mA (when 100 V AC applied) 5 mA (when 200 V AC applied) at 60 Hz leakage current Max. “ON-state” at max. 1.6 V voltage drop carrying current Min. load current 100 mA OFF-state dV/dt 100 V/µs 20 A type Part No. AQR20A1-Z AQR20A1-Z AQR20A1-Z AQR20A2-Z AQR20A2-Z AQR20A2-Z 4/6VDC 10/18VDC 18/28VDC 4/6VDC 10/18VDC 18/28VDC Remarks AQR20A1-S-Z AQR20A1-S-Z AQR20A1-S-Z AQR20A2-S-Z AQR20A2-S-Z AQR20A2-S-Z Items 4/6VDC 10/18VDC 18/28VDC 4/6VDC 10/18VDC 18/28VDC Input voltage 4 to 6 V DC 10 to 18 V DC 18 to 28 V DC 4 to 6 V DC 10 to 18 V DC 18 to 28 V DC Input Input impedance Approx. 0.26 kΩ Approx. 0.86 kΩ Approx. 1.36 kΩ Approx. 0.26 kΩ Approx. 0.86 kΩ Approx. 1.36 kΩ side Drop-out voltage, 1V min. Max. load current 20 A See “DATA 1” Load voltage 75 to 125 V AC 75 to 250 V AC Frequency 45 to 65 Hz Repetitive peak 400 V 600 V voltage In one cycle at Load Non-repetitive 200 A 60 Hz side surge current Max. “OFF-state” 2.5 mA (when 100 V AC applied) 5 mA (when 200 V AC applied) at 60 Hz leakage current Max. “ON-state” at max. 1.6 V voltage drop carrying current Min. load current 100 mA OFF-state dV/dt 100 V/µs Characteristics (at 20°C 68°F, Input ripple: 1% or less) Type Item Operate time, max. Zero-cross type Remarks (1/2 cycle of voltage sine wave) + 1 ms Release time, max. (1/2 cycle of voltage sine wave) + 1 ms Insulation resistance, min., Initial 100 MΩ between input, output and case Vibration resistance Shock resistance by 500 V DC 1,500 V AC between input, output and case For 1 min. Functional 10 to 55 Hz at double amplitude of 2 mm 10 minutes for X, Y, Z axes Destructive 10 to 55 Hz at double amplitude of 2 mm 1 hour for X, Y, Z axes Functional Min. 980 m/s2 {100 G} 4 time each for X, Y, Z axes Destructive Min. 980 m/s2 {100 G} 5 time each for X, Y, Z axes Breakdown voltage Ambient temperature –20°C to +80°C –4°F to +176°F Storage temperature –25°C to +85°C –13°F to +185°F Operational method Zero-cross (Turn-ON and Turn-OFF) OPERATING PRINCIPLE Internal circuit Input Input terminal circuit Photo TRIAC coupler Zerocross circuit Snubber circuit Trigger circuit + Wave form of input and output (Resistive load) Load voltage Triac R Output terminal C Input signal ON OFF Load current _ DIMENSIONS mm inch Plug-in terminal Schematic Input power source 44.8 26 1.764 1.024 9 .354 Mounting hole 4 1 3 2 Load Load power source 2-4.4 dia. 2-.173 dia. 47.6 1.874 59 2.323 Conform to AMP plug-in terminal #110 series receptacle _ + Mounting dimensions (Bottom view) Conform to AMP plug-in terminal #250 series receptacle 47.6 ± 0.1 1.874 ± .004 2-4.3 dia. or M4 2-.169 dia Max. 15 Max. .591 Max. 7.5 Max. .295 Max. 12.5 Max. .492 Screw terminal Schematic 4-M4 screw terminal Input power source 44.8 26 1.764 1.024 9 .354 Mounting hole 45.0 1.772 47.6 1.874 59 2.323 _ + 4 1 3 2 2-4.4 dia. 2-.173 dia. Mounting dimensions (Bottom view) 47.6 ± 0.1 1.874 ± .004 2-4.3 dia. or M4 2-.169 dia 7.5 .295 Load Max. 17 Max. .669 12.5 .492 Load power source AQ-R SOLID STATE RELAY ACCESSORIES mm inch AQP-HS-20A Heat sink 50 1.969 4.4 .173 4.4 .173 Mounting dimension (Bottom view) R2.2 .087 4-M4 to 4.4 dia 2 .079 1.5 .059 2-M4 33.3 100 +9.5 –1.5 1.311 3.937 +.929 –.059 80 3.150 11.1 .437 54 2.126 90 3.543 AQP-HS-20A 2 .079 47.6 1.874 100 3.937 24.5 .965 28.5 9 .354 1.122 45 1.772 90 ± 0.1 3.543 ± .004 1.5 .059 50 ± 0.2 1.969 ± .008 General tolerance: ±0.5 ±.020 AQP-DP DIN rail mounting plate 13.6 .535 56 2.205 47.6 1.874 M4 M4 AQP-DP M4 18.1 .713 44 1.732 70 2.765 86 3.386 General tolerance: ±0.5 ±.020 AT8-DLA1 ATA4806 Mounting rail Fastening plate ATA4806 AT8-DLA1 12 .472 50 M4 1.969 1,000 39.37 10 .394 5.5 .217 2.75R 15 10 15 .108R .591 .394 .591 40-5.5 × 15 slot 40-.217 × .591 slot 35 1.378 24 5 .945 1.5 .059 .197 7.5 .295 27 1.063 ATA4806 UP 5 .197 15 10 15 .591 .394 .591 10 .394 AQ-R DATA 1. Load current vs. ambient temperature 15 A type 20 6 (b) 4 (a) 12 (b) 2 8 7 6 4 0 –30 2 0 –30 20 40 60 80 Ambient temperature, °C 220 200 180 160 140 120 100 80 60 200 180 160 140 120 100 80 60 20 20 1 2 3 4 5 7 10 20 30 40 50 70 100 No. of cycles at 60 Hz 0 (b) 2 0 –30 20 40 60 80 Ambient temperature, °C 220 40 0 0 2-2. Non-repetitive surge current vs. carrying time (15 A type) 40 12 4 b) Without external heat sink If the mounting surface is not metallic and a heat sink is not used, expose the bottom surface and plate surface to improve heat dissipation. The graphs show the characteristics when the relay is mounted as shown in the right figure. Non-repetitive surge current, A 2-1. Non-repetitive surge current vs. carrying time (10 A type) (a) 16 8 0 Hole for radiation (40×35 mm) 20 40 60 80 Ambient temperature, °C 3 mm or greater Washers are added to lift the relay. 2-3. Non-repetitive surge current vs. carrying time (20 A type) Non-repetitive surge current, A 0 (a) With external heat sink • A heat sink; optional heat sink (AQP-HS-20A) or a 150×150×3.2 mm aluminum sheet (painted black) • The heat sink surface area is the required area for one solid-state relay. Non-repetitive surge current, A 16 15 Load current, A 8 20 ,,, ,, ,,, , (a) Load current, A Load current, A 10 20 A type ,,,, ,, ,,,, ,,, ,,, 10 A type 220 200 180 160 140 120 100 80 60 40 20 1 2 3 4 5 7 10 20 30 40 50 70 100 No. of cycles at 60 Hz 0 1 2 3 4 5 7 10 20 30 40 50 70 100 No. of cycles at 60 Hz 3. Input voltage vs. input current (10 A, 15 A, 20 A type) 30 Input current, mA 25 (4 to 6 V) 20 (10 to 18 V) 15 (18 to 28 V) 10 5 0 0 5 10 20 15 Input voltage, V 25 30 NOTE Regarding installation DIN Rail Mounting When the relay is mounted to a rail using the DIN mounting rail (optional), the rated capacity is limited to the characteristics of a relay without a heat sink attached. For Cautions for Use 6/1/1999 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd. Go To Online Catalog