Features • • • • • • • • • Single Voltage for Read and Write: 2.7V to 3.6V (BV), 3.0V to 3.6V (LV) Fast Read Access Time – 70 ns Internal Program Control and Timer 16K Bytes Boot Block with Lockout Fast Chip Erase Cycle Time – 10 seconds Byte-by-byte Programming – 30 µs/Byte Typical Hardware Data Protection Data Polling for End of Program Detection Low Power Dissipation – 25 mA Active Current – 50 µA CMOS Standby Current • Typical 10,000 Write Cycles • Small Packaging – 8 x 14 mm VSOP/TSOP Description The AT49BV/LV040(T) are 3-volt only, 4-megabit Flash memories organized as 524,288 words of 8-bits each. Manufactured with Atmel’s advanced nonvolatile CMOS technology, the devices offer access times to 70 ns with power dissipation of just 90 mW over the commercial temperature range. When the device is deselected, the CMOS standby current is less than 50 µA. The device contains a user-enabled “boot block” protection feature. Two versions of the feature are available: the AT49BV/LV040 locates the boot block at lowest order addresses (“bottom boot”); the AT49BV/LV040T locates it at highest order addresses (“top boot”). (continued) 4-megabit (512K x 8) Single 2.7-volt Battery-Voltage™ Flash Memory AT49BV040 AT49BV040T AT49LV040 AT49LV040T Pin Configurations Pin Name Function A0 - A18 Addresses CE Chip Enable OE Output Enable WE Write Enable I/O0 - I/O7 Data Inputs/Outputs VSOP Top View (8 x 14 mm) or TSOP Top View (8 x 20 mm) 29 28 27 26 25 24 23 22 21 14 15 16 17 18 19 20 5 6 7 8 9 10 11 12 13 A14 A13 A8 A9 A11 OE A10 CE I/O7 I/O1 I/O2 GND I/O3 I/O4 I/O5 I/O6 A7 A6 A5 A4 A3 A2 A1 A0 I/O0 4 3 2 1 32 31 30 A12 A15 A16 A18 VCC WE A17 PLCC Top View A11 A9 A8 A13 A14 A17 WE VCC A18 A16 A15 A12 A7 A6 A5 A4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 OE A10 CE I/O7 I/O6 I/O5 I/O4 I/O3 GND I/O2 I/O1 I/O0 A0 A1 A2 A3 Rev. 0679C–04/00 1 Powered by ICminer.com Electronic-Library Service CopyRight 2003 To allow for simple in-system reprogrammability, the AT49BV/LV040(T) does not require high input voltages for programming. Three-volt-only commands determine the read and programming operation of the device. Reading data out of the device is similar to reading from an EPROM. Reprogramming the AT49BV/LV040(T) is performed by erasing the entire four megabits of memory and then programming on a byte-by-byte basis. The typical byte programming time is a fast 30 µs. The end of a program cycle can be optionally detected by the Data Polling feature. Once the end of a byte program cycle has been detected, a new access for a read or program can begin. The typical number of program and erase cycles is in excess of 10,000 cycles. The optional 16K bytes boot block section includes a reprogramming write lockout feature to provide data integrity. The boot sector is designed to contain user-secure code, and when the feature is enabled, the boot sector is permanently protected from being reprogrammed. Block Diagram AT49BV/LV040 VCC GND OE WE CE ADDRESS INPUTS AT49BV/LV040T DATA INPUTS/OUTPUTS I/O7 - I/O0 DATA INPUTS/OUTPUTS I/O7 - I/O0 8 OE, CE, AND WE LOGIC 8 DATA LATCH DATA LATCH INPUT/OUTPUT BUFFERS INPUT/OUTPUT BUFFERS Y DECODER Y-GATING X DECODER MAIN MEMORY (496K BYTES) Y-GATING 7FFFFH OPTIONAL BOOT BLOCK (16K BYTES) 04000H 03FFFH 00000H 7FFFFH OPTIONAL BOOT BLOCK (16K BYTES) MAIN MEMORY (496K BYTES) 7C000H 7BFFFH 00000H Device Operation READ: The AT49BV/LV040(T) is accessed like an EPROM. When CE and OE are low and WE is high, the data stored at the memory location determined by the address pins is asserted on the outputs. The outputs are put in the high-impedance state whenever CE or OE is high. This dual-line control gives designers flexibility in preventing bus contention. ERASURE: Before a byte can be reprogrammed, the 512K bytes memory array (or 496K bytes if the boot block featured is used) must be erased. The erased state of the memory bits is a logical “1”. The entire device can be erased at one time by using a six-byte software code. The software chip erase code consists of six-byte load commands to specific address locations with a specific data pattern (please refer to “Chip Erase Cycle Waveforms” on page 8). After the software chip erase has been initiated, the device will internally time the erase operation so that no external clocks are required. The maximum time needed to erase the whole chip is tEC. If the boot block lockout feature has been enabled, the data in the boot sector will not be erased. 2 AT49BV/LV040(T) Powered by ICminer.com Electronic-Library Service CopyRight 2003 BYTE PROGRAMMING: Once the memory array is erased, the device is programmed (to a logical “0”) on a byte-by-byte basis. Please note that a data “0” cannot be programmed back to a “1”; only erase operations can convert “0”s to “1”s. Programming is accomplished via the internal device command register and is a four-bus cycle operation (please refer to the Command Definitions table). The device will automatically generate the required internal program pulses. The program cycle has addresses latched on the falling edge of WE or CE, whichever occurs last, and the data latched on the rising edge of WE or CE, whichever occurs first. Programming is completed after the specified tBP cycle time. The Data Polling feature may also be used to indicate the end of a program cycle. BOOT BLOCK PROGRAMMING LOCKOUT: The device has one designated block that has a programming lockout feature. This feature prevents programming of data in the designated block once the feature has been enabled. The size of the block is 16K bytes. This block, referred to as the boot block, can contain secure code that is used to bring up the system. Enabling the lockout feature will allow the boot AT49BV/LV040(T) code to stay in the device while data in the rest of the device is updated. This feature does not have to be activated; the boot block’s usage as a write-protected region is optional to the user. The address range of the AT49BV/LV040 boot block is 00000H to 03FFFH, while the address range of the AT49BV/LV040T boot block is 7C000H to 7FFFFH. Once the feature is enabled, the data in the boot block can no longer be erased or programmed. Data in the main memory block can still be changed through the regular programming method. To activate the lockout feature, a series of six program commands to specific addresses with specific data must be performed. Please refer to the Command Definitions table. BOOT BLOCK LOCKOUT DETECTION: A software method is available to determine if programming of the boot block section is locked out. When the device is in the software product identification mode (see Software Product Identification Entry and Exit sections) a read from address location 00002H will show if programming the boot block is locked out for the AT49BV/LV040 and a read from address 7C002H will show if programming the boot block is locked out for the AT49BV/LV040(T). If the data on I/O0 is low, the boot block can be programmed; if the data on I/O0 is high, the program lockout feature has been activated and the block cannot be programmed. The software product identification code should be used to return to standard operation. PRODUCT IDENTIFICATION: The product identification mode identifies the device and manufacturer as Atmel. It may be accessed by hardware or software operation. The hardware operation mode can be used by an external programmer to identify the correct programming algorithm for the Atmel product. For details, see “Operating Modes” on page 5 (for hardware operation) or “Software Product Identification Entry/Exit” on page 10. The manufacturer and device codes are the same for both modes. DATA POLLING: The AT49BV/LV040(T) features Data Polling to indicate the end of a program cycle. During a program cycle, an attempted read of the last byte loaded will result in the complement of the loaded data on I/O7. Once the program cycle has been completed, true data is valid on all outputs and the next cycle may begin. Data Polling may begin at any time during the program cycle. TO G G L E B I T: I n a d d i t i o n t o D a t a P o l l i n g , t h e AT49BV/LV040(T) provides another method for determining the end of a program or erase cycle. During a program or erase operation, successive attempts to read data from the device will result in I/O6 toggling between one and zero. Once the program cycle has completed, I/O6 will stop toggling and valid data will be read. Examining the toggle bit may begin at any time during a program cycle. HARDWARE DATA PROTECTION: The Hardware Data Protection feature protects against inadvertent programs to the AT49BV/LV040(T) in the following ways: (a) VCC sense: if VCC is below 1.8V (typical), the program function is inhibited. (b) Program inhibit: holding any one of OE low, CE high or WE high inhibits program cycles. (c) Noise filter: pulses of less than 15 ns (typical) on the WE or CE inputs will not initiate a program cycle. INPUT LEVELS: While operating with a 2.7V to 3.6V power supply, the address inputs and control inputs (OE, CE and WE) may be driven from 0 to 5.5V without adversely affecting the operation of the device. The I/O lines can only be driven from 0 to VCC + 0.6V. 3 Powered by ICminer.com Electronic-Library Service CopyRight 2003 Command Definition (in Hex) Command Sequence 1st Bus Cycle Bus Cycles Addr Data Read 1 Addr DOUT Chip Erase 6 5555 Byte Program 4 Boot Block Lockout(1) 2nd Bus Cycle 3rd Bus Cycle 4th Bus Cycle 5th Bus Cycle 6th Bus Cycle Addr Data Addr Data Addr Data Addr Data Addr Data AA 2AAA 55 5555 80 5555 AA 2AAA 55 5555 10 5555 AA 2AAA 55 5555 A0 Addr DIN 6 5555 AA 2AAA 55 5555 80 5555 AA 2AAA 55 5555 40 Product ID Entry 3 5555 AA 2AAA 55 5555 90 (2) 3 5555 AA 2AAA 55 5555 F0 Product ID Exit (2) Product ID Exit 1 XXXX F0 Notes: 1. The 16K byte boot sector has the address range 00000H to 03FFFH for the AT49BV/LV040 and 7C000H to 7FFFFH for the AT49BV/LV040T. 2. Either one of the Product ID Exit commands can be used. Absolute Maximum Ratings* Temperature under Bias ................................ -55°C to +125°C Storage Temperature ..................................... -65°C to +150°C All Input Voltages (including NC Pins) with Respect to Ground ...................................-0.6V to +6.25V All Output Voltages with Respect to Ground .............................-0.6V to VCC + 0.6V Voltage on OE with Respect to Ground ..................................-0.6V to + 13.5V 4 AT49BV/LV040(T) Powered by ICminer.com Electronic-Library Service CopyRight 2003 *NOTICE: Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. AT49BV/LV040(T) DC and AC Operating Range Operating Temperature (Case) Com. Ind. VCC Power Supply AT49LV040-70 AT49BV/LV040-90 AT49BV040-12 0°C - 70°C 0°C - 70°C 0°C - 70°C -40°C - 85°C -40°C - 85°C -40°C - 85°C 3.0V to 3.6V 2.7V to 3.6V/3.0V to 3.6V 2.7V to 3.6V Operating Modes Mode CE OE WE Ai I/O Read VIL VIL VIH Ai DOUT Program(2) VIL VIH VIL Ai DIN X High-Z Standby/Write Inhibit (1) VIH X X Program Inhibit X X VIH Program Inhibit X VIL X Output Disable X VIH X High-Z Product Identification Hardware VIL VIL VIH Software(2) Notes: 1. 2. 3. 4. A1 - A18 = VIL, A9 = VH,(3) A0 = VIL Manufacturer Code(4) A1 - A18 = VIL, A9 = VH,(3) A0 = VIH Device Code(4) A0 = VIL, A1 - A18 = VIL Manufacturer Code(4) A0 = VIH, A1 - A18 = VIL Device Code(4) X can be VIL or VIH. Refer to AC programming waveforms. VH = 12.0V ± 0.5V. Manufacturer Code: 1FH Device Code: 13H (AT49BV/LV040), 12H (AT49BV/LV040T). DC Characteristics Symbol Parameter Condition ILI Input Load Current ILO Max Units VIN = 0V to VCC 10 µA Output Leakage Current VI/O = 0V to VCC 10 µA ISB1 VCC Standby Current CMOS CE = VCC - 0.3V to VCC 50 µA ISB2 VCC Standby Current TTL CE = 2.0V to VCC 1 mA ICC(1) VCC Active Current f = 5 MHz; IOUT = 0 mA, VCC = 3.6V 25 mA VIL Input Low Voltage 0.8 V VIH Input High Voltage VOL Output Low Voltage VOH Notes: Min Typ 2.0 IOL = 2.1 mA Output High Voltage IOH = -100 µA; VCC = 3.0V 1. In the erase mode, ICC is 50 mA. 2. See details under “Software Product Identification Entry/Exit” on page 10. V 0.45 2.4 V V 5 Powered by ICminer.com Electronic-Library Service CopyRight 2003 AC Read Characteristics AT49LV040-70 Symbol Parameter tACC Min Max AT49BV/LV040-90 Min Max AT49BV040-12 Min Max Units Address to Output Delay 70 90 120 ns (1) CE to Output Delay 70 90 120 ns tOE(2) OE to Output Delay 0 35 0 40 0 50 ns tDF(3)(4) CE or OE to Output Float 0 25 0 25 0 30 ns tOH Output Hold from OE, CE or Address, whichever comes first 0 tCE 0 0 ns AC Read Waveforms(1)(2)(3)(4) Notes: 1. CE may be delayed up to tACC - tCE after the address transition without impact on tACC. 2. OE may be delayed up to tCE - tOE after the falling edge of CE without impact on tCE or by tACC - tOE after an address change without impact on tACC. 3. tDF is specified from OE or CE, whichever occurs first (CL = 5 pF). 4. This parameter is characterized and is not 100% tested. Input Test Waveforms and Measurement Level Output Test Load tR, tF < 5 ns Pin Capacitance f = 1 MHz, T = 25°C(1) Symbol CIN COUT Note: 6 Typ Max Units Conditions 4 6 pF VIN = 0V pF VOUT = 0V 8 12 1. This parameter is characterized and is not 100% tested. AT49BV/LV040(T) AT49BV/LV040(T) AC Byte Load Characteristics Symbol Parameter tAS, tOES Address, OE Setup Time tAH Address Hold Time tCS Min Max Units 0 ns 100 ns Chip Select Setup Time 0 ns tCH Chip Select Hold Time 0 ns tWP Write Pulse Width (WE or CE) 200 ns tDS Data Setup Time 100 ns tDH, tOEH Data, OE Hold Time 0 ns tWPH Write Pulse Width High 200 ns AC Byte Load Waveforms WE Controlled CE Controlled 7 Powered by ICminer.com Electronic-Library Service CopyRight 2003 Program Cycle Characteristics Symbol Parameter tBP Byte Programming Time tAS Address Setup Time 0 ns tAH Address Hold Time 100 ns tDS Data Setup Time 100 ns tDH Data Hold Time 0 ns tWP Write Pulse Width 200 ns tWPH Write Pulse Width High 200 ns tEC Erase Cycle Time Program Cycle Waveforms Chip Erase Cycle Waveforms Note: 8 OE must be high only when WE and CE are both low. AT49BV/LV040(T) Powered by ICminer.com Electronic-Library Service CopyRight 2003 Min Typ Max Units 30 50 µs 10 seconds AT49BV/LV040(T) Data Polling Characteristics(1) Symbol Parameter tDH Data Hold Time tOEH OE Hold Time Typ Max ns 10 ns OE to Output Delay Write Recovery Time 1. These parameters are characterized and not 100% tested. 2. See tOE spec in “AC Read Characteristics” on page 6. Units 0 (2) tOE tWR Notes: Min ns 0 ns Data Polling Waveforms Toggle Bit Characteristics(1) Symbol Parameter tDH Data Hold Time tOEH OE Hold Time Min OE to Output Delay tOEHP OE High Pulse tWR Notes: Write Recovery Time 1. These parameters are characterized and not 100% tested. 2. See tOE spec in “AC Read Characteristics” on page 6. Max Units 0 ns 10 ns (2) tOE Typ ns 150 ns 0 ns Toggle Bit Waveforms(1)(2)(3) Notes: 1. Toggling either OE or CE or both OE and CE will operate toggle bit. The tOEHP specification must be met by the toggling input(s). 2. Beginning and ending state of I/O6 will vary. 3. Any address location may be used but the address should not vary. 9 Powered by ICminer.com Electronic-Library Service CopyRight 2003 Software Product Identification Entry(1) LOAD DATA AA TO ADDRESS 5555 Boot Block Lockout Feature Enable Algorithm(1) LOAD DATA AA TO ADDRESS 5555 LOAD DATA 55 TO ADDRESS 2AAA LOAD DATA 55 TO ADDRESS 2AAA LOAD DATA 90 TO ADDRESS 5555 LOAD DATA 80 TO ADDRESS 5555 ENTER PRODUCT IDENTIFICATION (2)(3)(4) MODE Software Product Identification Exit LOAD DATA AA TO ADDRESS 5555 LOAD DATA 55 TO ADDRESS 2AAA OR LOAD DATA AA TO ADDRESS 5555 (1) LOAD DATA F0 TO ANY ADDRESS LOAD DATA 55 TO ADDRESS 2AAA EXIT PRODUCT IDENTIFICATION MODE (4) LOAD DATA 40 TO ADDRESS 5555 LOAD DATA F0 TO ADDRESS 5555 EXIT PRODUCT IDENTIFICATION MODE (4) Notes: 10 1. Data Format: I/O7 - I/O0 (Hex); Address Format: A14 - A0 (Hex). 2. A1 - A18 = VIL. Manufacturer Code is read for A0 = VIL; Device Code is read for A0 = VIH. 3. The device does not remain in identification mode if powered down. 4. The device returns to standard operation mode. 5. Manufacturer Code: 1FH Device Code: 13H (AT49BV/LV040), 12H (AT49BV/LV040T). AT49BV/LV040(T) Powered by ICminer.com Electronic-Library Service CopyRight 2003 PAUSE 1 second Notes: (2) 1. Data Format: I/O7 - I/O0 (Hex); Address Format: A14 - A0 (Hex). 2. Boot Block Lockout feature enabled. AT49BV/LV040(T) AT49BV040(T) Ordering Information ICC (mA) tACC (ns) Active Standby 90 25 120 90 120 Ordering Code Package Operation Range 0.05 AT49BV040-90JC AT49BV040-90TC AT49BV040-90VC 32J 32T 32V Commercial (0°C to 70°C) 25 0.05 AT49BV040-90JI AT49BV040-90TI AT49BV040-90VI 32J 32T 32V Industrial (-40°C to 85°C) 25 0.05 AT49BV040-12JC AT49BV040-12TC AT49BV040-12VC 32J 32T 32V Commercial (0°C to 70°C) 25 0.05 AT49BV040-12JI AT49BV040-12TI AT49BV040-12VI 32J 32T 32V Industrial (-40°C to 85°C) 25 0.05 AT49BV040T-90JC AT49BV040T-90TC AT49BV040T-90VC 32J 32T 32V Commercial (0°C to 70°C) 25 0.05 AT49BV040T-90JI AT49BV040T-90TI AT49BV040T-90VI 32J 32T 32V Industrial (-40°C to 85°C) 25 0.05 AT49BV040T-12JC AT49BV040T-12TC AT49BV040T-12VC 32J 32T 32V Commercial (0°C to 70°C) 25 0.05 AT49BV040T-12JI AT49BV040T-12TI AT49BV040T-12VI 32J 32T 32V Industrial (-40°C to 85°C) Package Type 32J 32-lead, Plastic J-leaded Chip Carrier Package (PLCC) 32T 32-lead, Plastic Thin Small Outline Package (TSOP) (8 x 20 mm) 32V 32-lead, Plastic Thin Small Outline Package (TSOP) (8 x 14 mm) 11 Powered by ICminer.com Electronic-Library Service CopyRight 2003 AT49LV040(T) Ordering Information ICC (mA) tACC (ns) Active Standby 70 25 90 70 90 Ordering Code Package 0.05 AT49LV040-70JC AT49LV040-70TC AT49LV040-70VC 32J 32T 32V Commercial (0°C to 70°C) 25 0.05 AT49LV040-70JI AT49LV040-70TI AT49LV040-70VI 32J 32T 32V Industrial (-40°C to 85°C) 25 0.05 AT49LV040-90JC AT49LV040-90TC AT49LV040-90VC 32J 32T 32V Commercial (0°C to 70°C) 25 0.05 AT49LV040-90JI AT49LV040-90TI AT49LV040-90VI 32J 32T 32V Industrial (-40°C to 85°C) 25 0.05 AT49LV040T-70JC AT49LV040T-70TC AT49LV040T-70VC 32J 32T 32V Commercial (0°C to 70°C) 25 0.05 AT49LV040T-70JI AT49LV040T-70TI AT49LV040T-70VI 32J 32T 32V Industrial (-40°C to 85°C) 25 0.05 AT49LV040T-90JC AT49LV040T-90TC AT49LV040T-90VC 32J 32T 32V Commercial (0°C to 70°C) 25 0.05 AT49LV040T-90JI AT49LV040T-90TI AT49LV040T-90VI 32J 32T 32V Industrial (-40°C to 85°C) Package Type 32J 32-lead, Plastic J-leaded Chip Carrier Package (PLCC) 32T 32-lead, Plastic Thin Small Outline Package (TSOP) (8 x 20 mm) 32V 32-lead, Plastic Thin Small Outline Package (TSOP) (8 x 14 mm) 12 AT49BV/LV040(T) Powered by ICminer.com Electronic-Library Service CopyRight 2003 Operation Range AT49BV/LV040(T) Packaging Information 32J, 32-lead, Plastic J-leaded Chip Carrier (PLCC) Dimensions in Inches and (Millimeters) 32T, 32-lead, Plastic Thin Small Outline Package (TSOP) Dimensions in Millimeters and (Inches)* JEDEC STANDARD MS-016 AE JEDEC OUTLINE MO-142 BA .045(1.14) X 45˚ PIN NO. 1 IDENTIFY .025(.635) X 30˚ - 45˚ .012(.305) .008(.203) .553(14.0) .547(13.9) .595(15.1) .585(14.9) .032(.813) .026(.660) .050(1.27) TYP INDEX MARK .530(13.5) .490(12.4) 18.5(.728) 18.3(.720) .021(.533) .013(.330) .030(.762) .015(.381) .095(2.41) .060(1.52) .140(3.56) .120(3.05) .300(7.62) REF .430(10.9) .390(9.90) AT CONTACT POINTS 0.50(.020) BSC 7.50(.295) REF 0.25(.010) 0.15(.006) 8.20(.323) 7.80(.307) .022(.559) X 45˚ MAX (3X) .453(11.5) .447(11.4) .495(12.6) .485(12.3) 20.2(.795) 19.8(.780) 1.20(.047) MAX 0.15(.006) 0.05(.002) 0 5 REF 0.20(.008) 0.10(.004) 0.70(.028) 0.50(.020) *Controlling dimension: millimeters 32V, 32-lead, Plastic Thin Small Outline Package (TSOP) Dimensions in Millimeters and (Inches)* JEDEC OUTLINE MO-142 BA INDEX MARK 12.5(.492) 12.3(.484) 0.50(.020) BSC 7.50(.295) REF 14.2(.559) 13.8(.543) 0.25(.010) 0.15(.006) 8.10(.319) 7.90(.311) 1.20(.047) MAX 0.15(.006) 0.05(.002) 0 5 REF 0.20(.008) 0.10(.004) 0.70(.028) 0.50(.020) *Controlling dimension: millimeters 13 Powered by ICminer.com Electronic-Library Service CopyRight 2003 Atmel Headquarters Atmel Operations Corporate Headquarters Atmel Colorado Springs 2325 Orchard Parkway San Jose, CA 95131 TEL (408) 441-0311 FAX (408) 487-2600 Europe 1150 E. Cheyenne Mtn. Blvd. Colorado Springs, CO 80906 TEL (719) 576-3300 FAX (719) 540-1759 Atmel Rousset Atmel U.K., Ltd. Coliseum Business Centre Riverside Way Camberley, Surrey GU15 3YL England TEL (44) 1276-686-677 FAX (44) 1276-686-697 Zone Industrielle 13106 Rousset Cedex France TEL (33) 4-4253-6000 FAX (33) 4-4253-6001 Asia Atmel Asia, Ltd. Room 1219 Chinachem Golden Plaza 77 Mody Road Tsimhatsui East Kowloon Hong Kong TEL (852) 2721-9778 FAX (852) 2722-1369 Japan Atmel Japan K.K. 9F, Tonetsu Shinkawa Bldg. 1-24-8 Shinkawa Chuo-ku, Tokyo 104-0033 Japan TEL (81) 3-3523-3551 FAX (81) 3-3523-7581 Fax-on-Demand North America: 1-(800) 292-8635 International: 1-(408) 441-0732 e-mail [email protected] Web Site http://www.atmel.com BBS 1-(408) 436-4309 Atmel Corporation 2000. Atmel Corporation makes no warranty for the use of its products, other than those expressly contained in the Company’s standard warranty which is detailed in Atmel’s Terms and Conditions located on the Company’s web site. The Company assumes no responsibility for any errors which may appear in this document, reserves the right to change devices or specifications detailed herein at any time without notice, and does not make any commitment to update the information contained herein. No licenses to patents or other intellectual property of Atmel are granted by the Company in connection with the sale of Atmel products, expressly or by implication. Atmel’s products are not authorized for use as critical components in life suppor t devices or systems. Marks bearing ® and/or ™ are registered trademarks and trademarks of Atmel Corporation. Terms and product names in this document may be trademarks of others. Printed on recycled paper. 0679C–04/00/xM Powered by ICminer.com Electronic-Library Service CopyRight 2003