1000 Series Pulse Transformers Max. Leakage Inductance mH Vμs μH pF Ω Ω Ω Vrms Pin Connection Style Mechanical Dimensions 1001C 1:1 3.0 200 22 23 1.2 1.0 - 2000 A 2 1002C 1:1:1 3.0 200 9 28 1.4 1.3 1.7 2000 B 1 1003C 2:1:1 12 400 35 30 4.0 1.8 2.4 2000 B 1 1007C 1:1:1 7.4 310 20 55 2.9 2.5 3.4 2000 B 1 Isolation to 4kVrms 1009C 1:1:1 22 550 85 18 10.6 8.9 12.2 2000 B 1 Compact Footprint 1013C 1:1:1 3.0 200 3 280 1.3 1.3 1.3 500VDC B 1 PCB Mounting 1016C 1:1 3.0 200 22 23 1.2 1.0 - 3500 A 2 Backward compatible with Sn/Pb soldering systems 1017C 1:1 0.8 130 4 20 0.4 0.3 - 4000 A 2 1024C 1.2CT:1CT 8.8 340 60 25 2.5 2.5 - 2000 C 1 1025C 2:1:1 24 570 70 20 7.5 3.5 4.5 2000 B 1 1026C 1:1:1 6.0 285 30 30 4.0 4.0 4.0 2000 B 1 1082C 100:1 6.1 280 - 6 0.7 0.1 - 2000 A 2 FEATURES RoHS compliant UL 94V-0 Package Material DESCRIPTION The 1000 series are intended for wideband and pulse operations. They are also suitable for signal isolation and use in small isolated power supplies. The compact footprint makes them ideal for applications where space is at a premium. Max. Interwinding Capacitance Max. DC Resistance Primary Winding Max. DC Resistance Secondary 1 winding Max. DC Resistance Secondary 2 winding Isolation Voltage Turns Ratio ±2% Min. Primary Inductance Order Code Min. Primary Constant, ET SELECTION GUIDE1 ABSOLUTE MAXIMUM RATINGS Operating free air temperature range 0°C to 70°C Storage temperature range -60°C to 125°C SOLDERING INFORMATION1 Peak wave solder temperature 300˚C for 10 seconds Pin finish Matte tin 1 For further information, please visit www.murata-ps.com/rohs All specifications typical at TA=25°C. TUBE DIMENSIONS 0.60±0.15 (0.024±0.006) 17.00 (0.669) All dimensions in mm (inches). Tube length: 480±2mm (18.9±0.08) Tube quantity: 30 8.00 (0.315) 7.00 (0.276) 24.00 (0.945) For full details go to www.murata-ps.com/rohs www.murata-ps.com Technical enquiries - email: [email protected], tel: +44 (0)1908 615232 KMP_1000C_B02 Page 1 of 2 1000 Series Pulse Transformers MECHANICAL DIMENSIONS PIN CONNECTIONS (TOP VIEW) 1 1 2 2 15.06 (0.593) 15.06 (0.593) Pri A 1003C Sec 5 6 15.06 (0.593) 15.06 (0.593) 1001C YYWW YYWW 1 2 Pri B 3 4 S2 15.75±0.50 (0.620±0.02) 20.5 (0.807) 15.75±0.50 (0.620±0.02) 20.5 (0.807) S1 5 6 Ø0.71±0.05 (Ø0.028±0.002) 1 2 Sec C Ø0.71±0.05 (Ø0.028±0.002) Pri 4 5.08 (0.20) 3 10.16 (0.40) 5.08 (0.20) 6 5 10.16 (0.40) 10.16 (0.40) All dimensions in mm (inches). Package weight: 8.0g Typ. TECHNICAL NOTES ISOLATION VOLTAGE REPEATED HIGH-VOLTAGE ISOLATION TESTING ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the insulative materials used. Such materials are susceptible to chemical degradation when subject to very high applied voltages. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. All products in this series are 100% production tested at their stated isolation voltage. A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?” For a part holding no specific agency approvals both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. USA: This consideration equally applies to agency recognized parts rated for better than functional isolation where wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. Mansfield (MA), Tel: (800) 233 2765, email: [email protected] Canada: Toronto, Tel: (866) 740 1232, email: [email protected] Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 www.murata-ps.com email: [email protected] ISO 9001 REGISTERED Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2008 Murata Power Solutions, Inc. www.murata-ps.com UK: Milton Keynes, Tel: +44 (0)1908 615232, email: [email protected] France: Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: [email protected] Germany: München, Tel: +49 (0)89-544334-0, email: [email protected] Japan: Tokyo, Tel: 3-3779-1031, email: [email protected] Osaka, Tel: 6-6354-2025, email: [email protected] Website: www.murata-ps.jp China: Shanghai, Tel: +86 215 027 3678, email: [email protected] Guangzhou, Tel: +86 208 221 8066, email: [email protected] Technical enquiries - email: [email protected], tel: +44 (0)1908 615232 KMP_1000C_B02 Page 2 of 2