SAW Components SAW Duplexer WCDMA / LTE Band XI Series/type: Ordering code: B7920 B39152B7920P810 Date: Version: January 7, 2011 2.0 EPCOS AG 2010. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS’ prior express consent is prohibited. SAW Components B7920 SAW Duplexer 1437.90 / 1485.90 MHz Data sheet Revision History Changes compared to previously issued iteration Issue 2.0 Originator K.Morozumi Detailed specification changes Initial release Please read cautions and warnings and important notes at the end of this document. 2 January 7, 2011 Date January 7, 2011 SAW Components B7920 SAW Duplexer 1437.90 / 1485.90 MHz Data sheet Application ■ Low-loss SAW duplexer for mobile telephone WCDMA/LTE Band XI systems Low insertion attenuation Low amplitude ripple Usable passband 20MHz(Lower and Middle band) Single ended to balanced transformation in Antenna-Rx path ■ Impedence transformation 50ohm to 100ohm in Antenna - Rx path ■ ■ ■ ■ Features 6 7 2 1 3 8 9 4 0.3 5 0.4 0.4 0.55 bottom view 0.4 Package size 2.5 x 2.0mm2 Package height 0.74 mm max. RoHS compatible Approx. weight 0.013g Package for Surface Mount Technology (SMT) ■ Ni, gold-plated terminals ■ Electrostatic Sensitive Device (ESD) ■ Moisuture Sensitivity Level (MSL) 3 ■ ■ ■ ■ ■ 0.68 0.9 side view 2.0 2.5 top view Pin configuration ■ ■ ■ ■ 1, 8 3 6 2, 4, 5, 7, 9 3 1 RX Output (balanced) TX Input Antenna To be grounded 8 4,5,9 2,7 6 Please read cautions and warnings and important notes at the end of this document. 3 January 7, 2011 SAW Components B7920 SAW Duplexer 1437.90 / 1485.90 MHz Data sheet Characteristics Temperature range for specification: Antenna terminating impedance: RX terminating impedance: TX terminating impedance: T = –20 ˚C to +85 ˚C ZANT= 50 Ω || 5.6 nH ZRX = 100Ω ZTX = 50 Ω Characterisitcs TX - ANT min. Center frequency fC Maximum insertion attenuation 1427.9 ... 1437.9 1437.9 ... 1447.9 Amplitude ripple(p-p) 1427.9 ... 1437.9 typ. @ 25 ˚C 1437.9 max. MHz MHz 1.3 2.0 dB MHz 1.5 2.5 dB MHz 0.2 1.0 dB ... 1447.9 MHz 0.4 1.0 dB Input VSWR (TX port) 1427.9 ... 1447.9 MHz 1.6 2.0 Output VSWR (ANT port) 1427.9 ... 1447.9 MHz 1.4 2.0 1437.9 Please read cautions and warnings and important notes at the end of this document. 4 January 7, 2011 SAW Components B7920 SAW Duplexer 1437.90 / 1485.90 MHz Data sheet Characteristics Temperature range for specification: Antenna terminating impedance: RX terminating impedance: TX terminating impedance: T = –20 ˚C to +85 ˚C ZANT= 50 Ω || 5.6 nH ZRX = 100Ω ZTX = 50 Ω Characterisitcs TX - ANT min. typ. @ 25 ˚C 30 25 35 29 5 51 46 47 46 46 41 40 41 37 33 30 24 17 max. α Attenuation 10 ... 1350 1350 ... 1390 1390 ... 1409 1475.9 ... 1495.9 1565 ... 1585 1574 ... 1577 1597 ... 1607 1607 ... 1680 1844.9 ... 1879.9 1884.5 ... 1919.6 2010 ... 2025 2110 ... 2170 2400 ... 2483.5 2855.8 ... 2905.8 4283.7 ... 4358.7 5150 ... 5850 Please read cautions and warnings and important notes at the end of this document. MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz 45 40 42 42 25 30 15 30 30 30 20 18 11 5 January 7, 2011 dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB SAW Components B7920 SAW Duplexer 1437.90 / 1485.90 MHz Data sheet Characteristics Temperature range for specification: Antenna terminating impedance: RX terminating impedance: TX terminating impedance: T = –20 ˚C to +85 ˚C ZANT= 50 Ω || 5.6 nH ZRX = 100Ω ZTX = 50 Ω Characterisitcs ANT - RX min. Center frequency fC Maximum insertion attenuation 1475.9 ... 1485.9 typ. @ 25 ˚C 1485.9 max. MHz MHz 2.0 2.5 dB ... 1495.9 MHz 1.7 2.5 dB Amplitude ripple (p-p) 1475.9 ... 1495.9 MHz 0.4 1.0 dB Input VSWR (ANT port) 1475.9 ... 1495.9 MHz 1.5 2.0 Output VSWR (RX port) 1475.9 ... 1495.9 MHz 1.4 2.0 1485.9 Common Mode Rejection Ratio CMRR 1475.9 ... 1495.9 MHz 1) 201) 27 dB A combination of 10o phase balance and 1dB amplitude balance corresponds to 19.6 dB CMRR. Please read cautions and warnings and important notes at the end of this document. 6 January 7, 2011 SAW Components B7920 SAW Duplexer 1437.90 / 1485.90 MHz Data sheet Characteristics Temperature range for specification: Antenna terminating impedance: RX terminating impedance: TX terminating impedance: T = –20 ˚C to +85 ˚C ZANT= 50 Ω || 5.6 nH ZRX = 100Ω ZTX = 50 Ω Characterisitcs ANT - RX min. typ. @ 25 ˚C 30 40 45 5 64 55 55 23 3 43 α Attenuation 1 1381 1427.9 1453 1516 1560 ... ... ... ... ... ... 1381 1429 1447.9 1462 1560 6000 MHz MHz MHz MHz MHz MHz 30 IMD Product Level Limits1) at f1=1437.9 MHz f2 = 48 MHz f2 = 2*f1 + 48MHz f2 = f1 - 48MHz f2 = 3*f1 + 48MHz 1) max. -130 -122 -111 -130 dB dB dB dB dB dB -106 -106 -106 -106 dBm dBm dBm dBm IMD product level limits for power levels Pf1=21.5dB (antenna port output power) and Pf2=15dBm (antenna port input power). Please read cautions and warnings and important notes at the end of this document. 7 January 7, 2011 SAW Components B7920 SAW Duplexer 1437.90 / 1485.90 MHz Data sheet Characteristics Temperature range for specification: Antenna terminating impedance: RX terminating impedance: TX terminating impedance: T = –20 ˚C to +85 ˚C ZANT= 50 Ω || 5.6 nH ZRX = 100Ω ZTX = 50 Ω Characterisitcs TX - RX Differential Mode Isolation 1427.9 ... 1447.9 min. typ. @ 25 ˚C max. α MHz 53 58 dB 1475.9 ... 1495.9 MHz 50 58 dB 1574 ... 1577 MHz 30 75 dB 2855.8 ... 2905.8 MHz 30 63 dB 4283.7 ... 4358.7 MHz 25 57 dB Common mode Isolation 1427.9 ... 1447.9 MHz 46 50 dB Please read cautions and warnings and important notes at the end of this document. 8 January 7, 2011 SAW Components B7920 SAW Duplexer 1437.90 / 1485.90 MHz Data sheet Maximum ratings Storage temperature range DC voltage ESD voltage Input power at 1427.9 - 1447.9 MHz elsewhere 1) Tstg VDC VESD PIN –40/+85 5 501) 29 10 ˚C V V dBm dBm machine model, 10 pulses source and load impedance 50 Ω continuous wave T = 50˚C, 5,000 h } acc. to JESD22-A115A (machine model), 10 negative & 10 positive pulses. Please read cautions and warnings and important notes at the end of this document. 9 January 7, 2011 SAW Components B7920 SAW Duplexer 1437.90 / 1485.90 MHz Data sheet Frequency Response Tx-ANT (passband) Frequency Response Tx-ANT (wideband) Please read cautions and warnings and important notes at the end of this document. 10 January 7, 2011 SAW Components B7920 SAW Duplexer 1437.90 / 1485.90 MHz Data sheet Frequency Response ANT-Rx (passband) Frequency Response ANT-Rx (wideband) Please read cautions and warnings and important notes at the end of this document. 11 January 7, 2011 SAW Components B7920 SAW Duplexer 1437.90 / 1485.90 MHz Data sheet Frequency Response Tx-Rx (passband) / Differential Frequency Response Tx-Rx (wideband) / Differential Please read cautions and warnings and important notes at the end of this document. 12 January 7, 2011 SAW Components B7920 SAW Duplexer 1437.90 / 1485.90 MHz Data sheet Frequency Response Tx-Rx (passband) / Common-mode Frequency Response Tx-Rx (wideband) / common-mode Please read cautions and warnings and important notes at the end of this document. 13 January 7, 2011 SAW Components B7920 SAW Duplexer 1437.90 / 1485.90 MHz Data sheet References Type B7920 Ordering code B39152B7920P810 Marking and package C61157-Z3-C47 Packaging F61074-V8153-Z000 Date codes L_1126 S-parameters B7920_NB.s4p, B7920_WB.s4p see file header for port/pin assignment table Soldering profile S_6001 RoHS compatible defined as compatible with the following documents: "DIRECTIVE 2002/95/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 27 January 2003 on the restriction of the use of certain hazardous substances in electrical and electronic equipment. 2005/618/EC from April 18th, 2005, amending Directive 2002/95/EC of the European Parliament and of the Council for the purposes of establishing the maximum concentration values for certain hazardous substances in electrical and electronic equipment." Moldability Before using in overmolding environment, please contact your EPCOS sales office. Matching coilss See Inductor pdf-catalog http://www.tdk.co.jp/tefe02/coil.htm#aname1 and Data Library for circuit simulation http://www.tdk.co.jp/etvcl/index.htm For further information please contact your local EPCOS sales office or visit our webpage at www.epcos.com . Published by EPCOS AG Surface Acoustic Wave Components Division P.O. Box 80 17 09, 81617 Munich, GERMANY EPCOS AG 2010. This brochure replaces the previous edition. For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or the international Representatives. Due to technical requirements components may contain dangerous substances. For information on the type in question please also contact one of our Sales Offices. Please read cautions and warnings and important notes at the end of this document. 14 January 7, 2011 Important notes The following applies to all products named in this publication: 1. 2. 3. 4. 5. 6. 7. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. The warnings, cautions and product-specific notes must be observed. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms of Delivery for Products and Services in the Electrical Industry” published by the German Electrical and Electronics Industry Association (ZVEI). The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DeltaCap, DigiSiMic, DSSP, FormFit, MiniBlue, MiniCell, MKD, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. 15 January 7, 2011