Bussmann® Disconnect Switch BDF60 and BDF100 Fusible, 60-100A, 600V BDF60J6 BDF100JT6 Components: Catalog Symbols*: BDF60J6, BDF100JT6 Ampere Rating: 60 to 100 Amperes Voltage Rating: 600 Volts Agency Approvals: UL Listed, Guide WPZX, File E155129 CSA Certified, File 58077M9 IEC 947-1 General Information: Bussmann fused disconnect switches are UL 98/CSA 22.2 No. 4 devices. This makes them suitable for use on service equipment, panel boards, switchboards, industrial control equipment, motor control centers, etc. *Catalog symbol is for switch only. Handles and shafts are ordered separately. Handles Style NEMA Type Color Pistol Pistol Pistol 1, 12 1, 3R, 12 4, 4X Blk Blk Blk Grip Length (Inches) Marking Padlock- Defeatable able Catalog Number 60-100A ( ▫ 0.24∑ x 0.24∑) 3.15 2.36 2.36 Off/On Off/On Off/On Yes Yes Yes Yes Yes No BDH20 BDH50 BDH57 Terminal Lug Kits - Kit Includes 6 Lugs Amp Rating Wire Size Wire Type Kit Catalog Number 100 200 400 600 & 800 #14 - 2/0 #6 - 300 kcmil #2 - 600 kcmil (2) #2 - 600 kcmil Cu/Al Cu/Al Cu/Al Cu/Al BDTL24 BDTL25 BDTL26 BDTL27 Shafts Fuse Maximum Horsepower Rating Type 200V 208V 240V 480V 600V BDF60J6 J 15 15 15 30 40 BDF100JT6 J† 25 25 30 40 50 †Class J fuses are standard. If 600V Class T fuses are desired, us BDTA1 adapters. CE logo denotes compliance with European Union Low Voltage Directive (50-1000 VAC, 75-1500 VDC). Refer to BIF document #8002 or contact Bussmann Application Engineering at 314-527-1270 for more information. Mounting Depth** Shaft Length Catalog Number 60 - 100 Amps ( ▫ 0.24∑ x 0.24∑) 5.50 8.00 11.00 13.75 16.54 - 8.50 11.00 14.00 16.75 19.69 5.90 8.26 11.41 14.17 16.93 BDS150 BDS210 BDS290 BDS360 BDS430 **Mounting depth is measured from outside panel door to mounting plate of disconnect. Shaft can be cut to desired length. Accessories: Fuse Covers and Terminal Shrouds (line-side) Switch Type Amp Rating Fuse Type 60 100 J J or T Voltage Fuse Covers Catalog Number Terminal Shrouds Catalog Number 600V 600V BDFC60J BDFC100 Not Required BDTSF1 Auxiliary Contacts - F60 through F100 Switch Aux. Contact Amp Rating Amp Rating 60 100 12-17-98 SB98107 Rev. A 6 6 Voltage 250 250 1 N.O. & 1 N.C. 2 N.O. & 2 N.C. Catalog Number Catalog Number BDAUX7 BDAUX7 BDAUX8 BDAUX8 Form No. BDF Page 1 of 2 BIF Doc #1121 Bussmann® Disconnect Switch BDF60 and BDF100 Fusible, 60-100A, 600V Dimensional Data 60 Amps 00.00 00.00 Inches Inches 00.0 00.00Millimeters Millimeters 0.23 0.27 Dia. 5.9 7.1 74.1 4.74 3.70 120.3 2.36 2.92 60.0 1.18 94.0 30.0 3.19 80.9 .80 1.54 20.2 39.1 1.46 4.85 37.0 123.1 5.57 141.4 6.85 ( 3 POLE ) 8.31 ( 4 POLE ) 2.00 174.0 50.8 211.0 5.50 ... 8.63 140.0 ... 219.0 100 Amps 1.75 2.13 44.4 54.1 0.26 Dia. 6.5 M6 X 1.0 0.23 6.0 0.27 Dia. 6.9 4.76 1.18 3.58 30.0 121.0 6.80 5.61 172.5 91.0 2.36 142.5 60.0 3.90 99.2 2.15 54.6 .79 20.0 5.15 7.70 130.8 195.5 8.39 213.0 2.01 5.50...8.62 51.0 139.7....219.0 1.14 30.0 8.78 223.0 The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 12-17-98 SB98107 Rev. A Form No. BDF Page 2 of 2 BIF Doc #1121