VISHAY 95PF80W

95PF(R)...(W) Series
Vishay High Power Products
Standard Recovery Diodes
Generation 2 DO-5 (Stud Version), 95 A
95PF(R)...
95PF(R)...W
FEATURES
• High surge current capability
• Designed for a wide range of applications
• Stud cathode and stud anode version
• Wire version available
• Low thermal resistance
• UL approval pending
DO-203AB (DO-5)
DO-203AB (DO-5)
• Compliant to RoHS directive 2002/95/EC
• Designed and qualified for multiple level
TYPICAL APPLICATIONS
• Battery charges
PRODUCT SUMMARY
• Converters
IF(AV)
95 A
• Power supplies
• Machine tool controls
• Welding
MAJOR RATINGS AND CHARACTERISTICS
PARAMETER
TEST CONDITIONS
IF(AV)
VALUES
UNITS
95
A
TC
140
°C
149
A
50 Hz
2000
60 Hz
2090
50 Hz
20 000
60 Hz
18 180
Range
400 to 1200
V
- 55 to 180
°C
IF(RMS)
IFSM
I2 t
VRRM
TJ
A
A2 s
ELECTRICAL SPECIFICATIONS
VOLTAGE RATINGS
TYPE
NUMBER
VOLTAGE
CODE
VRRM, MAXIMUM REPETITIVE
PEAK REVERSE VOLTAGE
V
VRSM, MAXIMUM NON-REPETITIVE
PEAK REVERSE VOLTAGE
V
40
400
500
80
800
960
120
1200
1440
95PF(R)...(W)
Document Number: 93532
Revision: 20-May-09
For technical questions, contact: [email protected]
IRRM MAXIMUM
AT TJ = 150 °C
mA
9
www.vishay.com
1
95PF(R)...(W) Series
Vishay High Power Products
Standard Recovery Diodes
Generation 2 DO-5 (Stud Version), 95 A
FORWARD CONDUCTION
PARAMETER
SYMBOL
Maximum average forward current
at case temperature
IF(AV)
Maximum RMS forward current
TEST CONDITIONS
180° conduction, half sine wave
IF(RMS)
t = 10 ms
Maximum peak, one cycle forward,
non-repetitive surge current
IFSM
t = 8.3 ms
t = 10 ms
t = 8.3 ms
t = 10 ms
Maximum I2t for fusing
I2t
t = 8.3 ms
t = 10 ms
t = 8.3 ms
Maximum I2√t for fusing
I2√t
Low level value of threshold voltage
Low level value of forward slope resistance
Maximum forward voltage drop
No voltage
reapplied
UNITS
95
A
140
°C
149
A
2000
No voltage
reapplied
100 % VRRM
reapplied
VALUES
2090
A
1680
Sinusoidal half wave,
initial TJ = 150 °C
1760
20 000
18 180
A2s
14 100
100 % VRRM
reapplied
12 800
t = 0.1 ms to 10 ms, no voltage reapplied
A2√s
200 000
VF(TO)
(16.7 % x π x IF(AV) < I < π x IF(AV)), TJ = TJ maximum
0.73
V
rf
(16.7 % x π x IF(AV) < I < π x IF(AV)), TJ = TJ maximum
2.4
mΩ
VFM
Ipk = 267 A, TJ = 25 °C, tp = 400 µs rectangular wave
1.40
V
THERMAL AND MECHANICAL SPECIFICATIONS
PARAMETER
SYMBOL
Maximum junction and storage
temperature range
TJ, TStg
Maximum thermal resistance,
junction to case
RthJC
Thermal resistance,
case to heatsink
RthCS
Maximum allowable
mounting torque
(+ 0 %, - 10 %)
TEST CONDITIONS
DC operation
UNITS
- 55 to 180
°C
0.27
K/W
Mounting surface, smooth, flat and greased
0.25
Not lubricated thread, tighting on nut (1)
3.4
(30)
Lubricated thread, tighting on nut (1)
2.3
(20)
Not lubricated thread, tighting on hexagon (2)
4.2
(37)
Lubricated thread, tighting on hexagon (2)
3.2
(28)
N·m
(lbf · in)
15.8
Approximate weight
Case style
VALUES
g
0.56
See dimensions - link at the end of datasheet
oz.
DO-203AB (DO-5)
Notes
(1) Recommended for pass-through holes
(2) Torque must be appliable only to hexagon and not to plastic structure, recommended for holed heatsink
www.vishay.com
2
For technical questions, contact: [email protected]
Document Number: 93532
Revision: 20-May-09
95PF(R)...(W) Series
Standard Recovery Diodes
Vishay High Power Products
Generation 2 DO-5 (Stud Version), 95 A
ΔRthJC CONDUCTION
CONDUCTION ANGLE
SINUSOIDAL CONDUCTION
RECTANGULAR CONDUCTION
180°
0.14
0.10
120°
0.16
0.17
90°
0.21
0.22
60°
0.30
0.31
30°
0.50
0.50
TEST CONDITIONS
UNITS
TJ = TJ maximum
K/W
Maximum Allowable Case Temperature (°C)
180
95PF(R) Series
RthJC = 0.27 K/W
170
160
Conduction Angle
150
180°
140
120°
90°
60°
130
30°
120
0
20
40
60
80
100
180
95PF(R) Series
RthJC (DC) = 0.27 K/W
170
160
Conduction Period
150
30°
140
60°
90°
120°
130
180°
DC
120
0
40
80
120
160
Average Forward Current (A)
Average Forward Current (A)
Fig. 1 - Current Ratings Characteristics
Fig. 2 - Current Ratings Characteristics
160
0.3
W
K/
W
1K
K/W
K/
7
80
5
100
60°
30°
0.
120
180°
120°
90°
140
0.
Maximum Allowable Forward Power Loss (W)
Maximum Allowable Case Temperature (°C)
Note
• The table above shows the increment of thermal resistance RthJC when devices operate at different conduction angles than DC
/W
1.5
K/W
2K
RMS Limit
60
/W
3 K/
W
40
Conduction Angle 5 K/W
95PF(R) Series
Tj = 180°C
20
0
0
20
40
60
80
Average Forward Current (A)
0
100
30
60
90
120
150
180
Maximum Allowable Ambient Temperature (°C)
Fig. 3 - Forward Power Loss Characteristics
Document Number: 93532
Revision: 20-May-09
For technical questions, contact: [email protected]
www.vishay.com
3
95PF(R)...(W) Series
Standard Recovery Diodes
Generation 2 DO-5 (Stud Version), 95 A
160
K/
K/
W
7
W
100
0.3
5
0.
90°
60°
30°
120
DC
1K
/W
1.5
80 RMS Limit
K/W
180°
120°
140
0.
Maximum Allowable Forward Power Loss (W)
Vishay High Power Products
K/W
2K
60
Conduction Period
40
/W
3 K/
W
5 K/W
95PF(R) Series
Tj = 180°C
20
0
0
30
60
90
120
Average Forward Current (A)
0
150
30
60
90
120
150
180
Maximum Allowable Ambient Temperature (°C)
1000
1800
At Any Rated Load Condition And With
Rated Vrrm Applied Following Surge.
Initial Tj = 150°C
@ 60 Hz 0.0083 s
1600
1400
@ 50 Hz 0.0100 s
1200
1000
800
600
95PF(R) Series
Instantaneous Forward Current (A)
Peak Haf Sine Wave Forward Current (A)
Fig. 4 - Forward Power Loss Characteristics
Tj = 180°C
100
10
95PF(R) Series
1
400
1
10
0
100
Number Of Equal Amplitude Half Cycle Current Pulses (N)
Maximum Non Repetitive Surge Current
2000
Versus Pulse Train Duration.
Initial Tj = 150°C
1800
No Voltage Reapplied
1600
Rated Vrrm Reapplied
1400
1200
1000
800
600
400
200
0.01
95PF(R) Series
0.1
1
1
1.5
2
2.5
3
Fig. 7 - Forward Voltage Drop Characteristics
Transient Thermal Impedance Z thJC (K/W)
2200
0.5
Instantaneous Forward Voltage (V)
Fig. 5 - Maximum Non-Repetitive Surge Current
Peak Haf Sine Wave Forward Current (A)
Tj = 25°C
1
Steady State Value
RthJC = 0.27 K/W
(DC Operation)
0.1
95PF(R) Series
0.01
0.0001 0.001
0.01
0.1
1
10
Pulse Train Duration (s)
Square Wave Pulse Duration (s)
Fig. 6 - Maximum Non-Repetitive Surge Current
Fig. 8 - Thermal Impedance ZthJC Characteristics
www.vishay.com
4
For technical questions, contact: [email protected]
Document Number: 93532
Revision: 20-May-09
95PF(R)...(W) Series
Standard Recovery Diodes
Vishay High Power Products
Generation 2 DO-5 (Stud Version), 95 A
ORDERING INFORMATION TABLE
Device code
1
95
PF
R
120
W
1
2
3
4
5
-
95 = Standard device
97 = Isolated lead on standard terminal
with silicone sleeve available for 1200 V only
(red = Reverse polarity)
(blue = Normal polarity)
2
-
3
-
PF = Plastic package
None = Stud normal polarity (cathode to stud)
R = Stud reverse polarity (anode to stud)
4
-
5
-
Voltage code x 10 = VRRM (see Voltage Ratings table)
None = Standard terminal
(see dimensions for 95PF(R)... - link at the end of datasheet)
W = Wire terminal
(see dimensions for 95PF(R)...W - link at the end of datasheet)
LINKS TO RELATED DOCUMENTS
Dimensions
Document Number: 93532
Revision: 20-May-09
www.vishay.com/doc?95345
For technical questions, contact: [email protected]
www.vishay.com
5
Outline Dimensions
Vishay Semiconductors
DO-203AB (DO-5) for 50PF(R)...(W),
80PF(R)...(W) and 95PF(R)...(W) Series
DIMENSIONS FOR 80PF(R), 50PF(R) AND 95PF(R) SERIES in millimeters
6.45 MIN.
Ø3
4.2 MAX.
1.2 MAX.
3.5 MIN.
4 MIN.
Plastic cap.
25.4 MAX.
11.45 MAX.
2.4 REF.
11 ± 0.4
1/4"28-UNF-2A
For metric devices: M6 x 1
17.25 MAX.
Ø 15.6 MAX.
Ø 16.8 MAX.
18.9
+ 0.1
0.0
Note
• For metric device please contact factory
Document Number: 95345
Revision: 26-Aug-08
For technical questions, contact: [email protected]
www.vishay.com
1
Outline Dimensions
DO-203AB (DO-5) for 50PF(R)...(W),
80PF(R)...(W) and 95PF(R)...(W) Series
Vishay Semiconductors
DIMENSIONS FOR 80PF(R)...(W), 50PF(R)...(W) AND 95PF(R)...(W) SERIES in millimeters
2.05 MAX.
Plastic cap.
25.4 MAX.
11.45 MAX.
2.4 REF.
11 ± 0.4
1/4"-28-UNF-2A
For metric devices: M6 x 1
17.25 MAX.
Ø 15.6 MAX.
Ø 16.8 MAX.
18.9
+ 0.1
0.0
Note
• For metric device please contact factory
www.vishay.com
2
For technical questions, contact: [email protected]
Document Number: 95345
Revision: 26-Aug-08
Outline Dimensions
DO-203AB (DO-5) for 50PF(R)...(W), Vishay Semiconductors
80PF(R)...(W) and 95PF(R)...(W) Series
DIMENSIONS FOR 52PF(R), 82PF(R) AND 97PF(R) SERIES in millimeters
12.2 MAX.
Ø 7 MAX.
123
6.6 mm2 external lead with
blue or red sleeve insulation
134.4
Plastic cap.
11.45 MAX.
2.4 REF.
11 ± 0.4
1/4"-28-UNF-2A
For metric devices: M6 x 1
Note
• For metric device please contact factory
Document Number: 95345
Revision: 26-Aug-08
For technical questions, contact: [email protected]
www.vishay.com
3
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree
to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and
damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay
or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to
obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Revision: 12-Mar-12
1
Document Number: 91000