Baumer_RDN5_DS_EN_1512.pdf (1.2 MB)

RDN5
Differential pressure switch for high static pressure
Main Features
„„
Excellent repeatability
„„
Dead band adjustment for regulation
„„
Fix dead band for control and alarm
„„
High static pressure up to 80 bar
Applications
„„Power generation safety equipment
„„Pressurized chambers control
„„Liquid level control
Technical Data
Pressure range
2 ... 10 mbar to 10 ... 2000 mbar
Case
Black Zamak
Temperature
Process: Ambient: Storage: Mounting
Wall mounting braket
Ground connection
Via internal terminal block
Electrical
connection
Terminal block with plastic cable gland :
- cable Ø 7 to 10.5 mm
Electrical function
See ordering code details in page 5
Adjustment
2 external adjustment screws for set point and
dead band.
When set point adjustment is required it is necessary
to know the static pressure, as it has an influence
on the set point.
-15 ... +150 °C
-25 ... + 55 °C
-40 ... + 70 °C
Repeatability
± 1% F.S. / constant pressure cycle
CE conformity
Low Voltage Directive LVD 2006/95/EC
Protection rating
IP 66 (EN 60529)
Process Connection Stainless steel 1.4404 (316L)
Sensing element
Scale
Cover
Pressure range codes 111 to 131
Flanges: Stainless steel 1.4404 (316L)
Diaphragm: Nitrile, Butyl rubber
Pressure range codes 156 to 163
Flanges: Stainless steel 1.4404 (316L)
Diaphragm: Viton®
Internal. Accuracy on reading ± 5% F.S.
Zamak blue painted
Captive stainless steel screws
Code SETP
Oxygen application
Code 0765
Mounting on 2" pipe
Code 0407
Stainless steel tag plate and wire
Code 9941
Lead seal of the adjustment screws
Code 8990
Mobile plug for stainless steel connector (Souriau)
Code 2249
Electrical connection: stainless steel connector (Souriau)
Code 2298
2015-11-12
Customer specific set point adjustment
Design and specifications subject to change without notice
Options
www.baumer.com
Data sheet A32.44
Page 1 / 5
RDN5
Differential pressure switch for high static pressure
Principle
∆P
A flexible sensing element actuates a microswitch by means of a
piston. The set point is adjusted by means of a compressible spring
installed in opposition.
LP
NC
NC
NC
C
C
C
NO
NO
LP
NO
HP < LP
HP > LP
Set point and reset point must be between 10% and 90% of the selected scale.
Standard factory adjustment
Setpoint at 50% of the scale on falling pressure
NC
C
NC
NC
C
C
NO
NO
NO
Customer speciffic factory adjustment (option SETP)
The following specifications have to be given with the order:
• Setpoint value
• Adjustment on falling or raising pressure.
• Static pressure
• Dead band value (as needed) when using an adjustable dead band
switch
Electrical connections
2 SPDT
1 SPDT
NC
Blue
COM
Red
NO
White
NC
Blue
COM
Red
NO
Yellow / green
NC
COM
NO
White
Blue
Red
White
2015-11-12
Design and specifications subject to change without notice
Yellow / green
www.baumer.com
Data sheet A32.44
Page 2 / 5
RDN5
Differential pressure switch for high static pressure
Micro switches characteristics
Switch code
Type
6 Vdc
A (B)
M (K)
C (W)
E (F)
H
D (V)
J
Standard
Gold contact
Hermetic
Ultra
sensitive
Manual reset
Ultra
sensitive
hermetic
Manual reset
10... 50 mA
5 mA ... 4 A
0.4... 10 A
0.4... 1A
N/A
0.4... N/A
12 Vdc
0.4... 10 A
10... 50 mA
5 mA ... 4 A
0.4... 1A
0.4... 4A
24 Vdc
0.4... 6A
10... 50 mA
5 mA ... 4 A
0.4... 1A
0.1... 8A
0.4... 4A
0.1... 8A
30 Vdc
0.4... 6A
10... 10 mA
5 mA ... 3 A
0.4... 1A
0.1... 8A
0.4... 2A
0.1... 8A
48 Vdc
0.4... 6A
10... 50 mA
5 mA ... 3 A
N/A
0.1... 8A
0.1... 8A
110 Vdc
0.1... 0.5 A
10... 50 mA
5 mA ... 1 A
N/A
220 Vdc
0.1... 0.25 A
10... 50 mA
5 mA ... 0.5 A
115 Vac
0.4... 10 A
10... 50 mA
50 mA ... 3 A
250 Vac
0.2... 10 A
10... 50 mA
2000 V
Dielectric rigidity between contacts
and ground
2000 V
N/A
4A
N/A
N/A
N/A
0.4... N/A
N/A
N/A
N/A
N/A
N/A
10 A
0.1... 10 A
N/A
0.1... 10 A
50 mA ... 2.5 A
0.2 ... 10 A
0.1... 5A
N/A
0.1... 5A
1500 V
2000 V
2000 V
1000 V
2000 V
Adjustable ranges
mbar
mbar
Max P
Static
Micro-switch dead band (1)
Adjustable dead band
Code
A (B*)
10%
bar
M (K*)
90%
Fixed dead band
C(W*)
10%
E(F*)
90%
10%
H
90%
10%
D (V*)
J
90%
mbar
2 ... 10
10
0 to 5
111
1.2 - 10
1.6 - 10
4.5 - 10
4.5 - 10
0.3
0.4
1.5
2
2 ... 20
50
0 to 5
112
1.7 - 20
2.2 - 20
5 - 20
5.5 - 20
0.4
0.5
2
3
2 ... 50
50
0 to 5
121
1.7 - 30
2.2 - 30
5 - 30
5.5 - 30
0.4
0.5
2
3
2 ... 100
100
0 to 5
131
1.7 - 40
2.5 - 40
5.5 - 40
10 - 40
0.5
0.7
2
3
10 ... 200
200
5.5 to 50
156
8 - 80
10.5 - 80
35 - 80
45 - 80
2.5
3.4
10
13
10 ... 400
400
5.5 to 50
157
15 - 150
20 - 150
40 - 150
50 - 150
4.5
6
18
24
10 ... 1000
1000
5.5 to 50
158
18 - 150
22 - 150
40 - 150
60 - 150
5
7
22
26.5
10 ... 700
700
5.5 to 80
161**
20 - 200
30 - 200
60 - 350
90 - 350
6
8
24
36
10 ... 1500
1500
5.5 to 80
162**
20 - 300
30 - 300
60 - 350
100 - 350
6
8
24
36
10 ... 2000
2000
5.5 to 80
163**
30 - 300
60 - 300
90 - 350
200 - 350
9
12
36
72
(*) For version with 2 microswitches lower values of the dead band must be multiplied x 1.5
(**) G1/4 female only
The value of the dead band is depending on the value of the set point.
This table contains the dead band values for set point adjustment at 10% and 90% of the selected scale. For adjustable dead band the lower value corresponds to
the dead band spring totally released and the higher corresponds to the dead band spring fully tensed. For other set points the dead band value can be calculated
by linear interpolation between the values at 10% and 90%.
2015-11-12
(1)
Design and specifications subject to change without notice
Scale
Max
ΔP
www.baumer.com
Data sheet A32.44
Page 3 / 5
RDN5
Differential pressure switch for high static pressure
Dimensions (mm)
125
76.5
=
144
139
=
5
64
100
58
130
76.5
45°
130
Pressure range codes: 156-157-158
Weight: 6.1 kg
Pressure range codes: 111-112-121-131
Weight: 10.2 kg
48
G1/2(M)
LP
Hex 24
Ø 148
HP
83
94
Hex 24
Ø 260
56
LP
88
G 1/2(M)
Hex 24
Hex 24
130
HP
G 1/2(M)
76.5
G1/2(M)
95
Pressure range codes: 161-162-163
Weight: 6.8 kg
Design and specifications subject to change without notice
28.5
97
LP
36
HP
Ø120
2015-11-12
2 holes G 1/4 (F)
Hex 24
www.baumer.com
Data sheet A32.44
Page 4 / 5
RDN5
Differential pressure switch for high static pressure
Ordering details RDN5
RD N
Model
Differential pressure switch for high static pressure
Approvals
Standard version without ATEX approval
5
.
xxx
/
RD
N
Sensing element
Diaphragm (Nitrile Butyl rubber, ranges 111 to 131, Viton ®, ranges 156 to 163)
Type of micro switches
Deadband
1 SPDT standard changeover switch
Adjustable
2 SPDT standard changeover switch
Adjustable
1 SPDT hermetically changeover switch
Adjustable
2 SPDT hermetically changeover switch
Adjustable
1 SPDT ultra sensitive changeover switch
Fix
2 SPDT ultra sensitive changeover switch
Fix
1 SPDT hermetically, ultra sensitive changeover switch
Fix
2 SPDT hermetically, ultra sensitive changeover switch
Fix
1 SPDT gold contact changeover switch
Adjustable
2 SPDT gold contact changeover switch
Adjustable
1 SPDT changeover switch, manual reset, opening on raising pressure
Fix
1 SPDT changeover switch, manual reset, opening on falling pressure
Fix
Pneumatic changeover contact, NO
Pneumatic changeover contact, NC
Process connection
G 1/4 female (only pressure ranges 161, 162, 163)
G 1/2 male (standard)
1/2 NPT male
1/4 NPT female
Pressure range (mbar)
Pressure range (kPa)
2
...
10
0.2 ...
1
2
...
20
0.2 ...
2
2
...
50
0.2 ...
5
2
... 100
0.2 ...
10
10
...
200
1
...
20
10
...
400
1
...
40
10
... 1000
1
...
100
10
...
700
1
...
70
10
... 1500
1
...
150
10
... 2000
1
...
200
Options to be added behind the / (see example below)
–
–
5
A
B
C
W
E
F
D
V
M
K
H
J
Z
Y
H
3
6
8
.
111
112
121
131
156
157
158
161
162
163
Process connection G1/4 female
Process connection G1/4 female
Process connection G1/4 female
/
Ordering example with options
RD
N
–
5
C
3
.
111
/
0407
_
9941
Design and specifications subject to change without notice
Differential pressure switch for high static pressure
Without ATEX approval
Sensing element diaphragm
1 SPDT hermetically changeover switch
Process connection G 1/2 male
Pressure range 2 ... 10 mbar
Option: Mounting on 2" pipe
2015-11-12
Option: Stainless steel tag plate and wire
www.baumer.com
Data sheet A32.44
Page 5 / 5