RFX2411_DataSheet.pdf

RFX2411
Preliminary Data Sheet
2.4GHZ TRANSMIT / RECEIVE ZIGBEE RFEIC WITH DIVERSITY SWITCH
DESCRIPTION
GND
21
VDD2
GND
20
19
VDD1
DNC
18
17
DNC
16
1
15
GND
IND
2
14
NC
ANTA
3
13
DNC
GND
4
12
NC
ANTB
5
11
TXRX
GND
6
7
TXEN
8
RXEN
9
PDET
Mode
10
SWant
The RFX2411 is a fully integrated, single-chip, single-die
RFeIC (RF Front-end Integrated Circuit) which incorporates
all the RF functionality needed for wireless ZigBee / smart
energy applications. The RFX2411 architecture integrates the
PA, LNA, Transmit and Receive switching circuitry, the
associated matching network, a harmonic filter and a diversity
switch all in a CMOS single-chip device. It also includes a
bypass mode to provide maximal level of flexibility for system
implementations.
This RFeIC is designed for use in 2.4GHz ISM band and
supports the 802.15.4 and ZigBee standard. Typical high
power applications include home and industrial automation,
smart power, and RF4CE among others. Combining superior
performance, high sensitivity and efficiency, low noise, small
form factor, and low cost, RFX2411 is the perfect solution for
applications requiring extended range and bandwidth.
RFX2411 has simple and low-voltage CMOS control logic,
and requires minimal external components for system
implementation. The PA power detect circuit is also
integrated.
FEATURES
 2.4GHz ZigBee High Power Single-Chip, SingleDie RF Front-End IC
 Antenna Diversity Switch
 2.4GHz Transmit High Power Amplifier with LowPass Harmonic Filter
 Low Noise Amplifier
 Transmit/Receive Switch Circuitry
 High Transmit Signal Linearity Meeting Standards
for OQPSK Modulation
 Integrated Power Detector for Transmit Power
Monitor and Control
 Low Voltage (1.2V) CMOS Control Logic
 ESD Protection Circuitry on All Ports
 DC Decoupled RF Ports
 Internal RF Decoupling on All VDD Bias Pins
 Low Noise Figure for the Receive Channel





 Very Low DC Power Consumption
Full On-chip Matching and Decoupling Circuitry
Minimal External Components Required
50-Ohm Input / Output Matching
Market Proven CMOS Technology
3 x 3 x 0.55mm Small Outline QFN-20 Package
with Exposed Ground Pad
APPLICATIONS






ZigBee Extended Range Devices
ZigBee Smart Power
RF4CE Remote Control
Home and Industrial Automation
Custom 2.4GHz Radio Systems
Mobile and Battery ZigBee Systems
1
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
RFX2411
Preliminary Data Sheet
PIN ASSIGNMENTS:
Pin Number
Pin Name
Description
1, 11,13, 19, 21
GND
2, 4
NC
5
TXRX
RF signal to/from the Transceiver: DC shorted to GND
6
TXEN
CMOS Input to Control TX Enable
7
RXEN
CMOS Input to Control RX Enable
8
PDET
Analog Voltage Proportional to the PA Power Output
9
MODE
CMOS Input to control mode of operation
10
SWant
CMOS Input to select antenna for diversity
12
ANTB
RF Signal from the PA or RF Signal Applied to the LNA; DC Shorted to GND
14
ANTA
RF Signal from the PA or RF Signal Applied to the LNA; DC Shorted to GND
15
IND
Inductor to GND
3, 16, 17
DNC
Reserved – Do Not Connect in the Application Circuit
18
VDD1
Voltage Supply Connection
20
VDD2
Voltage Supply Connection
Ground – Must be connected to Ground in the Application Circuit
No Internal Connection
PIN-OUT DIAGRAM:
VDD2 GND VDD1 DNC DNC
20
GND
19
18
17
16
1
21
GND
DNC
15
IND
14
ANTA
NC
2
DNC
3
13
GND
NC
4
12
ANTB
TXRX
5
11
GND
6
7
8
9
10
TXEN RXEN PDET MODE SWANT
2
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
RFX2411
Preliminary Data Sheet
ABSOLUTE MAXIMUM RATINGS:
Parameters
Units
Min
Max
Conditions
DC VDD Voltage Supply
V
0
4.0
All VDD Pins
DC Control Pin Voltage
V
0
3.6
Through 1Kohm resistor
Through VDD Pins when TX is “ON”
DC VDD Current Consumption
mA
350
TX RF Input Power
dBm
+5
ANT RF RX Input Power
dBm
+5
LNA Mode
ANT RF RX Input Power
dBm
+16
Bypass Mode
Junction Temperature
o
C
Storage Ambient Temperature
o
C
-50
V
> 1000
ESD Voltage (HBM)
+150
+150
No RF and DC Voltages Applied
Appropriate care required according to
JEDEC Standards
Human Body Model
Note: Sustained operation at or above the Absolute Maximum Ratings for any one or combinations of
the above parameters may result in permanent damage to the device and is not recommended.
All Maximum RF Input Power Ratings assume 50-Ohm terminal impedance.
RECOMENDED OPERATING CONDITIONS:
Parameters
Units
Min
Typ
Max
Conditions
DC VDD Voltage Supply (Note 1)
V
2.0
3.3
3.6
All VDD Pins
Control Voltage “High”
V
1.2
VDD
Through 1Kohm resistor
Control Voltage “Low”
V
0
0.3
DC Control Pin Current Consumption
μA
1
Mode, SWant, TXEN, RXEN
DC Shutdown Current
nA
300
Mode, SWant, TXEN, RXEN; Low
PA Turn On/Off Time
µsec
1
LNA Turn On/Off Time
µsec
1
Antenna Switch Time
µsec
1
o
Operating Ambient Temperature
ja
o
C
-40
+125
See Note 2
C/W
35
Note 1: VDD1 and VDD2 supply pins are internally connected.
Note2: For operation above +85 oC, use the ja as guidance for system design to assure the junction
temperature will not exceed the maximum of +150 oC.
3
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
RFX2411
Preliminary Data Sheet
TRANSMIT TECHNICAL PARAMETERS (VDD=3.3V; T=+25 oC)
Parameters
Units
Min
Typ
Max
Conditions
Operating Frequency Band
GHz
2.4
2.5
All RF Pins Terminated by 50 Ohm
Saturated Output Power
dBm
+21
Output P1dB
dBm
+19
CW Input
dB
26
High Idq TX Mode
dB
24
Low Idq TX Mode
Second Harmonic
dBc
-35
POUT <= +20dBm, CW at ANT Pin
Third Harmonic
dBc
-35
POUT <= +20dBm, CW at ANT Pin
mA
95
POUT = +20dBm, High Idq TX Mode
mA
95
POUT = +20dBm, Low Idq TX Mode
mA
18
High Idq TX Mode
mA
15
Low Idq TX Mode
Input Return Loss
dB
-15
Output Return Loss
dB
-7
V
0.14
Pout = +5dBm, 10kΩ load
V
0.9
Pout = +20dBm, 10kΩ load
Ohm
50
RF Leakage Active Antenna to non-Active
Antenna
dB
-18
Antenna A/B leaking into Antenna B/A
Load VSWR for Stability (Set Pout=20dBm at
50 ohm)
N/A
6:1
All Non-Harmonically Related Spurs
Less than -60dBm/MHz (CW)
Load VSWR for Ruggedness (Set
Pout=20dBm at 50 ohm)
N/A
10:1
No Damage
Small-Signal Gain
Total Supply Current
TX Quiescent Current
Power Detector Voltage
Input / Output Impedance Single-Ended
4
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
RFX2411
Preliminary Data Sheet
RECEIVE TECHNICAL PARAMETERS (VDD=3.3V; T=+25 oC)
Parameters
Operating Frequency Band
Units
Min
GHz
2.4
Typ
Max
Conditions
2.5
All RF Pins Terminated by 50 Ohm
14
Low Noise Figure Mode
10
Low Current Mode
2.5
Low Noise Figure Mode
3.5
Low Current Mode
-8
Low Noise Figure Mode
-3
Low Current Mode
9
Low Noise Figure Mode
4
Low Current Mode
Ohm
50
At TXRX and ANT Pins
Input Return Loss
dB
-8
At ANT Pin, Low NF Mode
Output Return Loss
dB
-12
At TXRX Pin, Low NF Mode
Gain
dB
Noise Figure
dB
Input P1dB
dBm
RX Quiescent Current
mA
RF Port Impedance
BYPASS MODE TECHNICAL PARAMETERS (VDD=3.3V; T=+25 oC):
Parameters
Operating Frequency
Insertion Loss
Units
Min
GHz
2.4
Typ
5
dBm
Current Consumption
Conditions
2.5
dB
Input P1dB
Max
>16
nA
At ANTA or ANTB
700
Through VDD Supply Pins
CONTROL LOGIC TRUTH TABLE
TXEN
RXEN
MODE
Mode of Operation
SWant
Mode of Operation
0
0
0
Shutdown Mode
1
ANTA port enabled
0
0
1
Bypass Mode
0
ANTB port enabled
1
X
0
Low Idq TX Mode
1
X
1
High Idq TX Mode
Note:
“1” denotes high voltage state (>
1.2V)
0
1
0
Low Noise Figure Receive Mode
0
1
1
Low Current Receive Mode
“0” denotes low voltage stage (<0.3V) at
Control Pins
“X” denotes do not care: either “1” or “0”
can be applied
PCB LAND PATTERN
5
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
RFX2411
Preliminary Data Sheet
0.2 mm
0.4mm
0.25mm
0.65mm
0.
0.
0.
1.7 mm x
1.7mm
3.5mm
0.
3.0mm
PACKAGE MARKING:
Pin 1 Mark
2411
First Line
Part Number
LLLL.L
Second Line
Lot Number
AAYYWW
Third Line
Date Code
6
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
RFX2411
Preliminary Data Sheet
PACKAGE DIMENSIONS:
A
A1
X4 Places – Connected to center pad (GND)
b
Dimensions (mm)
Min
Nom
A
0.5
0.55
A1
0.00
b
0.15
0.2
D
2.95
3.00
D2
1.65
1.70
E
2.95
3.00
E2
1.65
1.70
e
0.35
0.4
L
0.35
0.40
D2
D
e
Max
0.6
0.05
0.25
3.05
1.75
3.05
1.75
0.45
0.45
Pin 1 Mark
L
E
E2
Pin 1
7
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
RFX2411
Preliminary Data Sheet
TAPE AND REEL INFORMATION:
8
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
RFX2411
Preliminary Data Sheet
RECOMMENDED SOLDER REFLOW PROFILE
9