Model # BXHF1214 High Frequency Microwave Amplifier Frequency Range: 8 GHz to 12 GHz Features • High Output Power: 18 dBm Typical • Laser Sealed Housing • Broad Bandwidth: 8 GHz to 12 GHz • Unconditionally Stable Model BXHF1214 is a high frequency amplifier covering 8 GHz to 12 GHz. This design utilizes a laser sealed housing for superior environmental protection. This standard design may also be ordered in a screened MILSTD-883 version (Model #SXHF1214.) All specification ratings are based on measurements in a 50 Ω (ohm) system with a DC supply voltage tolerance of +/- 2%. Technical Specifications Maximum Ratings Parameter Typical Frequency Range Min/Max Maximum (No Damage) Ratings 8 to 12 GHz 8 to 12 GHz 15 dB 14 dB Min 4 dB 5 dB Max Output Power @ 1 dB Compression 18 dBm 17 dBm Output 3rd Order Intercept 30 dBm - Output 2nd Order Intercept 28 dBm - 25 dB - Input VSWR 1.5:1 2.0:1 Max Output VSWR 1.5:1 2.0:1 Max Supply Voltage 15 volts 15 volts Supply Current 225 mA 250 mA Max Gain Noise Figure Reverse Isolation Storage Temperature -55°C to +85°C Operating Temperature -40°C to +85°C DC Voltage @ 25°C 18 volts Input Drive @ 25°C (CW) +18 dBm * Typical values are measured at 25°C, but not guaranteed. Mechanical & Electrical Parameter Specification Specification Temperatures (Min/Max) -20°C to +70°C Housing Size 0.870” L x 1.060” W x 0.300” H Housing Drawing HF1 Package RF Connectors SMA Female Replaceable Connectors Rev Date: 4/29/2015 © API Technologies Corp. Proprietary Information Page # 1 | www.apitech.com | micro.apitech.com | +1.888.553.7531 | [email protected] Model # BXHF1214 Typical Performance Graphs Rev Date: 4/29/2015 © API Technologies Corp. Proprietary Information Page # 2 | www.apitech.com | micro.apitech.com | +1.888.553.7531 | [email protected] Model # BXHF1214 Instructions Grounding Instructions Care should be taken to effectively ground each unit. Revisions API reserves the right to make revisions to both product and/or the information contained within their datasheets without advanced notice. Min./Max. Values Specifications (and maximum ratings) are guaranteed when tested in a 50 Ω (ohm) system. Typical performance graphs and values are measured at 25°C, but not guaranteed. Outline Drawing Rev Date: 4/29/2015 © API Technologies Corp. Proprietary Information Page # 3 | www.apitech.com | micro.apitech.com | +1.888.553.7531 | [email protected]