NCP4354AADAPGEVB_TEST_PROCEDURE.PDF - 83.0 KB

Test Procedure for the NCP4354AADAPGEVB Evaluation Board
Figure 1: Test Setup
The following steps describe the test procedure for all these boards:
Required Equipment:
Current limited AC Power Supply (e.g. AGILENT 6811B) ………………………
DC Volt-Meter able to measure up to 60 V DC (e.g. KEITHLEY 2000) …………
DC Amp-Meter able to measure up to 5 A DC (e.g. FLUKE 89 IV)………………
DC Electronic Load (e.g. AGILENT 6060B) ……………………………………...
1pc
1pc
1pc
1pc
Test Procedure:
1. Connect the test setup as shown in Figure 1.
2. Apply an input voltage, VIN = 85 Vac
3. Apply IOUT(load) = 100 mA
4. Check that VOUT = 19 Vdc
5. Set IOUT to 3.5 A
6. Check that VOUT = 19 Vdc
7. Disconnect DC load
8. Check if VOUT slowly decreases down to 2.8 V and then quickly rises to 19 V
9. Turn off VIN
10. End of the test
11/20/2012
-1-