LINER LTC2489IDEPBF

LTC2489
16-Bit 2-/4-Channel
ΔΣ ADC with Easy Drive Input Current
Cancellation and I2C Interface
FEATURES
■
■
■
■
■
■
■
■
■
■
■
■
■
DESCRIPTION
Up to 2 Differential or 4 Single-Ended Inputs
Easy DriveTM Technology Enables Rail-to-Rail
Inputs with Zero Differential Input Current
Directly Digitizes High Impedance Sensors with
Full Accuracy
2-Wire I2C Interface with 9 Addresses Plus One
Global Address for Synchronization
600nV RMS Noise (0.02LSB Transition Noise)
GND to VCC Input/Reference Common Mode Range
Simultaneous 50Hz/60Hz Rejection
2ppm INL, No Missing Codes
1ppm Offset and 15ppm Full-Scale Error
No Latency: Digital Filter Settles in a Single Cycle,
Even After a New Channel is Selected
Single Supply, 2.7V to 5.5V Operation (0.8mW)
Internal Oscillator
Tiny 4mm × 3mm DFN Package
The LTC®2489 is a 4-channel (2-channel differential),
16-bit, No Latency ΔΣ™ ADC with Easy Drive technology
and a 2-wire, I2C interface. The patented sampling scheme
eliminates dynamic input current errors and the shortcomings of on-chip buffering through automatic cancellation of
differential input current. This allows large external source
impedances and rail-to-rail input signals to be directly
digitized while maintaining exceptional DC accuracy.
The LTC2489 includes an integrated oscillator. This device
can be configured to measure an external signal from combinations of 4 analog input channels operating in singleended or differential modes. It automatically rejects line
frequencies of 50Hz and 60Hz simultaneously.
The LTC2489 allows a wide, common mode input range
(0V to VCC), independent of the reference voltage. Any
combination of single-ended or differential inputs can be
selected and the first conversion, after a new channel is
selected, is valid. Access to the multiplexer output enables
optional external amplifiers to be shared between all
analog inputs and auto calibration continuously removes
their associated offset and drift.
APPLICATIONS
■
■
■
■
Direct Sensor Digitizer
Direct Temperature Measurement
Instrumentation
Industrial Process Control
, LT, LTC and LTM are registered trademarks of Linear Technology Corporation.
No Latency ΔΣ and Easy Drive are trademarks of Linear Technology Corporation. All other
trademarks are the property of their respective owners.
TYPICAL APPLICATION
+FS Error vs RSOURCE at IN+ and IN–
Data Acquisition System with Temperature Compensation
80
2.7V TO 5.5V
CH3
IN+
REF +
1.7k
16-BIT ΔΣ ADC
WITH EASY-DRIVE
IN–
10μF
REF –
COM
SDA
SCL
2-WIRE
I2C INTERFACE
CA1
CA0
9-PIN SELECTABLE
ADDRESSES
FO
OSC
+FS ERROR (ppm)
4-CHANNEL
MUX
CH2
0.1μF
VCC
CH0
CH1
VCC = 5V
= 5V
60 VREF
VIN+ = 3.75V
– = 1.25V
40 VIN
FO = GND
20 TA = 25°C
CIN = 1μF
0
–20
–40
–60
–80
1
2489 TA01a
10
100
1k
RSOURCE (Ω)
10k
100k
2489 TA01b
2489f
1
LTC2489
ABSOLUTE MAXIMUM RATINGS
PIN CONFIGURATION
(Notes 1, 2)
Supply Voltage (VCC) ................................... –0.3V to 6V
Analog Input Voltage
(CH0 to CH3, COM) ..................–0.3V to (VCC + 0.3V)
REF+, REF– ....................................–0.3V to (VCC + 0.3V)
Digital Input Voltage......................–0.3V to (VCC + 0.3V)
Digital Output Voltage ...................–0.3V to (VCC + 0.3V)
Operating Temperature Range
LTC2489C ................................................ 0°C to 70°C
LTC2489I ............................................. –40°C to 85°C
Storage Temperature Range................... –65°C to 150°C
FO
1
14 REF–
CA0
2
13 REF+
CA1
3
SCL
4
SDA
5
10 CH2
GND
6
9 CH1
COM
7
8 CH0
12 VCC
15
11 CH3
DE PACKAGE
14-LEAD (4mm × 3mm) PLASTIC DFN
TJMAX = 125°C, θJA = 37°C/W
EXPOSED PAD (PIN 15) IS GND, MUST BE SOLDERED TO PCB
ORDER INFORMATION
LEAD FREE FINISH
TAPE AND REEL
PART MARKING
PACKAGE DESCRIPTION
TEMPERATURE RANGE
LTC2489CDE#PBF
LTC2489IDE#PBF
LTC2489CDE#TRPBF
LTC2489IDE#TRPBF
2489
2489
14-Lead (4mm × 3mm) Plastic DFN
14-Lead (4mm × 3mm) Plastic DFN
0°C to 70°C
–40°C to 85°C
Consult LTC Marketing for parts specified with wider operating temperature ranges.
Consult LTC Marketing for information on non-standard lead based finish parts.
For more information on lead free part marking, go to: http://www.linear.com/leadfree/
For more information on tape and reel specifications, go to: http://www.linear.com/tapeandreel/
2489f
2
LTC2489
ELECTRICAL CHARACTERISTICS
The ● denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at TA = 25°C. (Notes 3, 4)
PARAMETER
CONDITIONS
Resolution (No Missing Codes)
0.1V ≤ VREF ≤ VCC, –FS ≤ VIN ≤ +FS (Note 5)
MIN
TYP
MAX
UNITS
Integral Nonlinearity
5V ≤ VCC ≤ 5.5V, VREF = 5V, VIN(CM) = 2.5V (Note 6)
2.7V ≤ VCC ≤ 5.5V, VREF = 2.5V, VIN(CM) = 1.25V (Note 6)
●
2
1
20
Offset Error
2.5V ≤ VREF ≤ VCC, GND ≤ IN+ = IN– ≤ VCC (Note 13)
●
0.5
2.5
Offset Error Drift
2.5V ≤ VREF ≤ VCC, GND ≤ IN+ = IN– ≤ VCC
Positive Full-Scale Error
2.5V ≤ VREF ≤ VCC, IN+ = 0.75VREF , IN– = 0.25VREF
Positive Full-Scale Error Drift
2.5V ≤ VREF ≤ VCC, IN+ = 0.75VREF , IN– = 0.25VREF
Negative Full-Scale Error
2.5V ≤ VREF ≤ VCC, IN+ = 0.25VREF , IN– = 0.75VREF
Negative Full-Scale Error Drift
2.5V ≤ VREF ≤ VCC, IN+ = 0.25VREF , IN– = 0.75VREF
0.1
ppm of VREF/°C
Total Unadjusted Error
5V ≤ VCC ≤ 5.5V, VREF = 2.5V, VIN(CM) = 1.25V
5V ≤ VCC ≤ 5.5V, VREF = 5V, VIN(CM) = 2.5V
2.7V ≤ VCC ≤ 5.5V, VREF = 2.5V, VIN(CM) = 1.25V
15
15
15
ppm of VREF
ppm of VREF
ppm of VREF
Output Noise
2.7V < VCC < 5.5V, 2.5V ≤ VREF ≤ VCC,
GND ≤ IN+ = IN– ≤ VCC (Note 12)
0.6
μVRMS
16
Bits
ppm of VREF
ppm of VREF
μV
10
nV/°C
●
32
0.1
ppm of VREF
ppm of VREF/°C
●
32
ppm of VREF
CONVERTER CHARACTERISTICS
The ● denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at TA = 25°C. (Note 3)
PARAMETER
CONDITIONS
Input Common Mode Rejection DC
2.5V ≤ VREF ≤ VCC, GND ≤ IN+ = IN– ≤ VCC (Note 5)
●
Input Normal Mode Rejection 50Hz/60Hz ±2%
2.5V ≤ VREF ≤ VCC, GND ≤ IN+ = IN– ≤ VCC (Notes 5, 9)
2.5V ≤ VREF ≤ VCC, GND ≤ IN+ = IN– ≤ VCC (Note 5)
VREF = 2.5V, IN+ = IN– = GND
VREF = 2.5V, IN+ = IN– = GND (Notes 7, 9)
VREF = 2.5V, IN+ = IN– = GND (Notes 8, 9)
●
87
●
120
Reference Common Mode Rejection DC
Power Supply Rejection DC
Power Supply Rejection, 50Hz ±2%
Power Supply Rejection, 60Hz ±2%
MIN
TYP
MAX
UNITS
140
dB
dB
140
dB
120
dB
120
dB
120
dB
ANALOG INPUT AND REFERENCE
The ● denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at TA = 25°C. (Note 3)
SYMBOL
PARAMETER
IN+
Absolute/Common Mode IN+ Voltage
(IN+ Corresponds to the Selected Positive Input Channel)
CONDITIONS
MIN
TYP
MAX
GND – 0.3V
VCC + 0.3V
V
IN–
Absolute/Common Mode IN– Voltage
(IN– Corresponds to the Selected Negative Input Channel)
GND – 0.3V
VCC + 0.3V
V
VIN
Input Differential Voltage Range (IN+ – IN–)
●
–FS
+FS
FS
Full Scale of the Differential Input (IN+ – IN–)
●
0.5VREF
LSB
Least Significant Bit of the Output Code
●
FS/216
REF+
Absolute/Common Mode REF+ Voltage
●
0.1
REF–
Absolute/Common Mode REF– Voltage
●
GND
VCC
+
REF – 0.1V
VREF
Reference Voltage Range (REF+ – REF–)
●
0.1
VCC
CS(IN+)
IN+ Sampling Capacitance
CS(IN–)
IN– Sampling Capacitance
11
pF
CS(VREF)
VREF Sampling Capacitance
11
pF
IDC_LEAK(IN+)
IN+ DC Leakage Current
●
–10
V
V
11
Sleep Mode, IN+ = GND
UNITS
1
V
V
V
pF
10
nA
2489f
3
LTC2489
ANALOG INPUT AND REFERENCE
The ● denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at TA = 25°C. (Note 3)
IDC_LEAK(IN–)
IN– DC Leakage Current
Sleep Mode, IN– = GND
●
–10
1
10
nA
IDC_LEAK(REF+) REF+ DC Leakage Current
Sleep Mode, REF+ = VCC
●
–100
1
100
nA
IDC_LEAK(REF–)
REF– DC Leakage Current
Sleep Mode, REF– = GND
●
–100
1
100
nA
tOPEN
MUX Break-Before-Make
QIRR
MUX Off Isolation
VIN = 2VP-P DC to 1.8MHz
50
ns
120
dB
I2C INPUTS AND DIGITAL OUTPUTS
The ● denotes the specifications which apply over the full
operating temperature range, otherwise specifications are at TA = 25°C. (Note 3)
SYMBOL
PARAMETER
VIH
High Level Input Voltage
CONDITIONS
●
MIN
TYP
MAX
UNITS
VIL
Low Level Input Voltage
●
VIHA
High Level Input Voltage for Address Pins CA0, CA1
●
VILA
Low Level Input Voltage for Address Pins CA0, CA1
●
0.05VCC
RINH
Resistance from CA0, CA1 to VCC to Set Chip Address
Bit to 1
●
10
kΩ
RINL
Resistance from CA0, CA1 to GND to Set Chip Address
Bit to 0
●
10
kΩ
RINF
Resistance from CA0, CA1 to GND or VCC to Set Chip
Address Bit to Float
●
2
II
Digital Input Current
●
–10
VHYS
Hysteresis of Schmidt Trigger Inputs
(Note 5)
●
0.05VCC
VOL
Low Level Output Voltage (SDA)
I = 3mA
●
tOF
Output Fall Time VIH(MIN) to VIL(MAX)
Bus Load CB 10pF to
400pF (Note 14)
●
IIN
Input Leakage
0.1VCC ≤ VIN ≤ VCC
CCAX
External Capacitative Load on Chip Address Pins (CA0, CA1)
for Valid Float
0.7VCC
V
0.3VCC
V
0.95VCC
V
V
MΩ
10
μA
V
0.4
V
250
ns
●
1
μA
●
10
pF
20 + 0.1CB
POWER REQUIREMENTS
The ● denotes the specifications which apply over the full operating temperature
range, otherwise specifications are at TA = 25°C. (Note 3)
SYMBOL
PARAMETER
VCC
Supply Voltage
ICC
Supply Current
CONDITIONS
MIN
●
Conversion Current (Note 11)
Sleep Mode (Note 11)
●
●
TYP
MAX
5.5
V
160
1
275
2
μA
μA
2.7
UNITS
2489f
4
LTC2489
DIGITAL INPUTS AND DIGITAL OUTPUTS
The ● denotes the specifications which apply over the
full operating temperature range, otherwise specifications are at TA = 25°C. (Note 3)
SYMBOL
PARAMETER
CONDITIONS
fEOSC
External Oscillator Frequency Range
(Note 16)
MAX
UNITS
●
tHEO
tLEO
tCONV
Conversion Time
MIN
10
4000
kHz
External Oscillator High Period
●
0.125
50
μs
External Oscillator Low Period
●
0.125
50
μs
●
144.1
149.9
ms
ms
Internal Oscillator
External Oscillator (Note 10)
TYP
146.9
41036/fEOSC (in kHz)
I2C TIMING CHARACTERISTICS
The ● denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at TA = 25°C. (Note 3, 15)
SYMBOL
PARAMETER
fSCL
SCL Clock Frequency
CONDITIONS
●
MIN
0
tHD(STA)
Hold Time (Repeated) Start Condition
●
0.6
μs
tLOW
Low Period of the SCL Pin
●
1.3
μs
tHIGH
High Period of the SCL Pin
●
0.6
μs
tSU(STA)
Set-Up Time for a Repeated Start Condition
●
0.6
μs
tHD(DAT)
Data Hold Time
●
0
tSU(DAT)
Data Set-Up Time
●
100
TYP
MAX
UNITS
400
kHz
0.9
μs
ns
tr
Rise Time for SDA Signals
(Note 14)
●
20 + 0.1CB
300
ns
tf
Fall Time for SDA Signals
(Note 14)
●
20 + 0.1CB
300
ns
tSU(STO)
Set-Up Time for Stop Condition
●
0.6
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
Note 2: All voltage values are with respect to GND.
Note 3: VCC = 2.7V to 5.5V unless otherwise specified.
VREFCM = VREF/2, FS = 0.5VREF
VIN = IN+ – IN–, VIN(CM) = (IN+ – IN–)/2,
where IN+ and IN– are the selected input channels.
Note 4: Use internal conversion clock or external conversion clock source
with fEOSC = 307.2kHz unless otherwise specified.
Note 5: Guaranteed by design, not subject to test.
Note 6: Integral nonlinearity is defined as the deviation of a code from a
straight line passing through the actual endpoints of the transfer curve.
The deviation is measured from the center of the quantization band.
Note 7: fEOSC = 256kHz ±2% (external oscillator).
μs
Note 8: fEOSC = 307.2kHz ±2% (external oscillator).
Note 9: Simultaneous 50Hz/60Hz (internal oscillator) or fEOSC = 280kHz
±2% (external oscillator).
Note 10: The external oscillator is connected to the FO pin. The external
oscillator frequency, fEOSC, is expressed in kHz.
Note 11: The converter uses its internal oscillator.
Note 12: The output noise includes the contribution of the internal
calibration operations.
Note 13: Guaranteed by design and test correlation.
Note 14: CB = capacitance of one bus line in pF (10pF ≤ CB ≤ 400pF).
Note 15: All values refer to VIH(MIN) and VIL(MAX) levels.
Note 16: Refer to Applications Information section for performance versus
data rate graphs.
2489f
5
LTC2489
TYPICAL PERFORMANCE CHARACTERISTICS
Integral Nonlinearity
(VCC = 5V, VREF = 5V)
VCC = 5V
VREF = 5V
VIN(CM) = 2.5V
FO = GND
–45°C
1
2
INL (ppm OF VREF)
2
25°C
0
85°C
–1
Integral Nonlinearity
(VCC = 2.7V, VREF = 2.5V)
3
VCC = 5V
VREF = 2.5V
VIN(CM) = 1.25V
FO = GND
2
INL (ppm OF VREF)
3
3
1
–45°C, 25°C, 85°C
0
–1
–2
–2
–3
–2.5 –2 –1.5 –1 –0.5 0 0.5 1 1.5
INPUT VOLTAGE (V)
2
–3
–1.25
2.5
–0.75
12
8
85°C
25°C
4
0
–45°C
–4
–8
–12
–2.5 –2 –1.5 –1 –0.5 0 0.5 1 1.5
INPUT VOLTAGE (V)
2
VCC = 5V
VREF = 2.5V
VIN(CM) = 1.25V
FO = GND
12
85°C
–45°C
0
–4
–0.75
–0.2
–0.3
–1
0
1
3
2
VIN(CM) (V)
–4
4
5
6
2489 G07
–0.75
0.2
Offset Error vs VCC
VCC = 5V
VREF = 5V
VIN = 0V
FO = GND
0.1
0
–0.2
–0.3
–45 –30 –15
0 15 30 45 60
TEMPERATURE (°C)
1.25
–0.25
0.25
0.75
INPUT VOLTAGE (V)
2489 G06
0.3
–0.1
–0.1
–45°C
0
–12
–1.25
1.25
–0.25
0.25
0.75
INPUT VOLTAGE (V)
OFFSET ERROR (ppm OF VREF)
0
1.25
2489 G03
85°C
25°C
4
Offset Error vs Temperature
0.3
OFFSET ERROR (ppm OF VREF)
0.1
VCC = 2.7V
VREF = 2.5V
VIN(CM) = 1.25V
FO = GND
2489 G05
Offset Error vs VIN(CM)
0.2
–0.25
0.25
0.75
INPUT VOLTAGE (V)
–8
2489 G04
OFFSET ERROR (ppm OF VREF)
8
25°C
4
–12
–1.25
2.5
VCC = 5V
VREF = 5V
VIN = 0V
TA = 25°C
FO = GND
–0.75
Total Unadjusted Error
(VCC = 2.7V, VREF = 2.5V)
–8
0.3
–1
Total Unadjusted Error
(VCC = 5V, VREF = 2.5V)
TUE (ppm OF VREF)
TUE (ppm OF VREF)
8
–45°C, 25°C, 85°C
0
2489 G02
Total Unadjusted Error
(VCC = 5V, VREF = 5V)
VCC = 5V
VREF = 5V
VIN(CM) = 2.5V
FO = GND
1
–3
–1.25
1.25
–0.25
0.25
0.75
INPUT VOLTAGE (V)
2489 G01
12
VCC = 2.7V
VREF = 2.5V
VIN(CM) = 1.25V
FO = GND
–2
TUE (ppm OF VREF)
INL (ppm OF VREF)
Integral Nonlinearity
(VCC = 5V, VREF = 2.5V)
75
90
2489 G08
0.2
0.1
REF+ = 2.5V
REF– = GND
VIN = 0V
VIN(CM) = GND
TA = 25°C
FO = GND
0
–0.1
–0.2
–0.3
2.7
3.1
3.5
3.9 4.3
VCC (V)
4.7
5.1
5.5
2489 G09
2489f
6
LTC2489
TYPICAL PERFORMANCE CHARACTERISTICS
On-Chip Oscillator Frequency
vs Temperature
Offset Error vs VREF
310
VCC = 5V
REF – = GND
VIN = 0V
VIN(CM) = GND
TA = 25°C
FO = GND
308
0
–0.1
306
304
302
–0.2
0
1
2
3
VREF (V)
5
4
VCC = 4.1V
VREF = 2.5V
VIN = 0V
VIN(CM) = GND
FO = GND
300
–45 –30 –15
–0.3
0 15 30 45 60
TEMPERATURE (°C)
75
300
90
–20
REJECTION (dB)
–40
–60
–80
VCC = 4.1V DC ±1.4V
VREF = 2.5V
IN+ = GND
IN– = GND
FO = GND
TA = 25°C
–60
–80
–60
–80
–120
–120
1M
–140
1.8
160
140
VCC = 2.7V
120
500
450
1.6
1.4
VCC = 5V
1.0
0.8
0.6
VCC = 2.7V
0 15 30 45 60
TEMPERATURE (°C)
75
90
2489 G16
400
VCC = 5V
350
300
VCC = 3V
250
200
0.4
150
0.2
100
–45 –30 –15
VREF = VCC
IN+ = GND
IN– = GND
TA = 25°C
FO = GND
1.2
30800
Conversion Current
vs Output Data Rate
SUPPLY CURRENT (μA)
SLEEP MODE CURRENT (μA)
CONVERSION CURRENT (μA)
2.0
FO = GND
VCC = 5V
30700
30750
FREQUENCY AT VCC (Hz)
2489 G15
Sleep Mode Current
vs Temperature
180
30650
2489 G14
Conversion Current
vs Temperature
200
–140
30600
0 20 40 60 80 100 120 140 160 180 200 220
FREQUENCY AT VCC (Hz)
2489 G13
5.5
VCC = 4.1V DC ±0.7V
VREF = 2.5V
IN+ = GND
IN– = GND
–40 FO = GND
TA = 25°C
–120
10k 100k
1k
100
FREQUENCY AT VCC (Hz)
5.0
–20
–100
10
4.0
4.5
VCC (V)
PSRR vs Frequency at VCC
–100
1
3.5
0
–100
–140
2.7 3.0
2489 G12
PSRR vs Frequency at VCC
0
VCC = 4.1V DC ±0.7V
VREF = 2.5V
IN+ = GND
IN– = GND
FO = GND
TA = 25°C
–40
304
2489 G11
PSRR vs Frequency at VCC
–20
306
302
2489 G10
0
VREF = 2.5V
VIN = 0V
VIN(CM) = GND
FO = GND
TA = 25°C
308
FREQUENCY (kHz)
0.1
310
REJECTION (dB)
0.2
FREQUENCY (kHz)
OFFSET ERROR (ppm OF VREF)
0.3
REJECTION (dB)
On-Chip Oscillator Frequency
vs VCC
0
–45 –30 –15
100
0 15 30 45 60
TEMPERATURE (°C)
75
90
2489 G17
0
10 20 30 40 50 60 70 80 90 100
OUTPUT DATA RATE (READINGS/SEC)
2489 G18
2489f
7
LTC2489
PIN FUNCTIONS
FO (Pin 1): Frequency Control Pin. Digital input that controls
the internal conversion clock rate. When FO is connected
to GND, the converter uses its internal oscillator running at
307.2kHz. The conversion clock may also be overridden by
driving the FO pin with an external clock in order to change
the output rate and the digital filter rejection null.
CA0, CA1 (Pins 2, 3): Chip Address Control Pins. These
pins are configured as a three-state (LOW, HIGH, Floating)
address control bits for the device’s I2C address.
SCL (Pin 4): Serial Clock Pin of the I2C Interface. The
LTC2489 can only act as a slave and the SCL pin only accepts an external serial clock. Data is shifted into the SDA
pin on the rising edges of the SCL clock and output through
the SDA pin on the falling edges of the SCL clock.
I2C
SDA (Pin 5): Bidirectional Serial Data Line of the
Interface. In the transmitter mode (Read), the conversion result is output through the SDA pin, while in the
receiver mode (Write), the device channel select bits are
input through the SDA pin. The pin is high impedance
during the data input mode and is an open drain output
(requires an appropriate pull-up device to VCC) during the
data output mode.
COM (Pin 7): The Common Negative Input (IN –) for All
Single-Ended Multiplexer Configurations. The voltage
on CH0-CH3 and COM pins can have any value between
GND – 0.3V to VCC + 0.3V. Within these limits, the two
selected inputs (IN+ and IN– ) provide a bipolar input
range (VIN = IN+ – IN– ) from –0.5 • VREF to 0.5 • VREF .
Outside this input range, the converter produces unique
over-range and under-range output codes.
CH0 to CH3 (Pin 8-Pin 11): Analog Inputs. May be programmed for single-ended or differential mode.
VCC (Pin 12): Positive Supply Voltage. Bypass to GND with
a 10μF tantalum capacitor in parallel with a 0.1μF ceramic
capacitor as close to the part as possible.
REF+, REF – (Pin 13, Pin 14): Differential Reference Input.
The voltage on these pins can have any value between
GND and VCC as long as the reference positive input, REF+,
remains more positive than the negative reference input,
REF–, by at least 0.1V. The differential voltage (VREF = REF+
– REF –) sets the full-scale range for all input channels.
Exposed Pad (Pin 15): Ground. This pin is ground and
must be soldered to the PCB ground plane. For prototyping
purposes, this pin may remain floating.
GND (Pin 6): Ground. Connect this pin to a common ground
plane through a low impedance connection.
FUNCTIONAL BLOCK DIAGRAM
INTERNAL
OSCILLATOR
VCC
GND
CH0
CH1
CH2
CH3
COM
FO
(INT/EXT)
AUTOCALIBRATION
AND CONTROL
REF +
REF –
IN+
MUX
IN–
–
+
1.7k
DIFFERENTIAL
3RD ORDER
ΔΣ MODULATOR
I2C
INTERFACE
SDA
SCL
CA0
CA1
DECIMATING FIR
ADDRESS
2489 BD
2489f
8
LTC2489
APPLICATIONS INFORMATION
CONVERTER OPERATION
Converter Operation Cycle
The LTC2489 is a multichannel, low power, delta-sigma
analog-to-digital converter with a 2-wire, I2C interface.
Its operation is made up of four states (see Figure 1).
The converter operating cycle begins with the conversion, followed by the sleep state and ends with the data
input/output cycle .
POWER-ON RESET
DEFAULT INPUT CHANNEL:
IN+ = CH0, IN– = CH1
SLEEP
ACKNOWLEDGE
YES
DATA OUTPUT/INPUT
NO
Ease of Use
The LTC2489 data output has no latency, filter settling
delay, or redundant data associated with the conversion
cycle. There is a one-to-one correspondence between the
conversion and the output data. Therefore, multiplexing
multiple analog inputs is straightforward. Each conversion,
immediately following a newly selected input is valid and
accurate to the full specifications of the device.
CONVERSION
NO
the LTC2489 is addressed for a read operation, the device
begins outputting the conversion result under the control
of the serial clock (SCL). There is no latency in the conversion result. The data output is 24 bits long and contains a
16-bit plus sign conversion result. Data is updated on the
falling edges of SCL allowing the user to reliably latch data
on the rising edge of SCL. A new conversion is initiated
by a stop condition following a valid write operation or an
incomplete read operation. The conversion automatically
begins at the conclusion of a complete read cycle (all 24
bits read out of the device).
STOP
OR READ
24 BITS
The LTC2489 automatically performs offset and full-scale
calibration every conversion cycle independent of the
input channel selected. This calibration is transparent
to the user and has no effect on the operation cycle described above. The advantage of continuous calibration
is extreme stability of offset and full-scale readings with
respect to time, supply voltage variation, input channel,
and temperature drift.
Easy Drive Input Current Cancellation
YES
2489 F01
Figure 1. State Transition Table
Initially, at power-up, the LTC2489 performs a conversion. Once the conversion is complete, the device enters
the sleep state. In the sleep state, power consumption is
reduced by two orders of magnitude. The part remains in
the sleep state as long it is not addressed for a read/write
operation. The conversion result is held indefinitely in a
static shift register while the part is in the sleep state.
The device will not acknowledge an external request during the conversion state. After a conversion is finished,
the device is ready to accept a read/write request. Once
The LTC2489 combines a high precision, delta-sigma ADC
with an automatic, differential, input current cancellation
front end. A proprietary front end passive sampling network
transparently removes the differential input current. This
enables external RC networks and high impedance sensors to directly interface to the LTC2489 without external
amplifiers. The remaining common mode input current
is eliminated by either balancing the differential input impedances or setting the common mode input equal to the
common mode reference (see the Automatic Differential
Input Current Cancellation section). This unique architecture does not require on-chip buffers, thereby enabling
signals to swing beyond ground and VCC. Moreover, the
2489f
9
LTC2489
APPLICATIONS INFORMATION
cancellation does not interfere with the transparent offset
and full-scale auto-calibration and the absolute accuracy
(full scale + offset + linearity + drift) is maintained even
with external RC networks.
Power-Up Sequence
The LTC2489 automatically enters an internal reset state
when the power supply voltage, VCC, drops below approximately 2.0V. This feature guarantees the integrity of
the conversion result and input channel selection.
When VCC rises above this threshold, the converter creates
an internal power-on-reset (POR) signal with a duration
of approximately 4ms. The POR signal clears all internal
registers. The conversion immediately following a POR
cycle is performed on the input channels IN+ = CH0 and
IN – = CH1. The first conversion following a POR cycle
is accurate within the specification of the device if the
power supply voltage is restored to (2.7V to 5.5V) before
the end of the POR interval. A new input channel can be
programmed into the device during this first data input/
output cycle.
Reference Voltage Range
This converter accepts a truly differential, external reference voltage. The absolute/common mode voltage range
for the REF+ and REF – pins covers the entire operating
range of the device (GND to VCC). For correct converter
operation, VREF must be positive (REF+ > REF –).
The LTC2489 differential reference input range is 0.1V to
VCC. For the simplest operation, REF+ can be shorted to VCC
and REF – can be shorted to GND. The converter output noise
is determined by the thermal noise of the front end circuits.
Since the transition noise is well below 1LSB (0.02LSB), a
decrease in reference voltage will proportionally improve
the converter resolution and improve INL.
Input Voltage Range
The analog inputs are truly differential with an absolute,
common mode range for the CH0-CH3 and COM input
pins extending from GND – 0.3V to VCC + 0.3V. Within
these limits, the LTC2489 converts the bipolar differential input signal VIN = IN+ – IN– (where IN+ and IN – are
the selected input channels), from –FS = –0.5 • VREF
to +FS = 0.5 • VREF where VREF = REF+ - REF–. Outside
this range, the converter indicates the overrange or the
underrange condition using distinct output codes (see
Table 1).
In order to limit any fault current due to input ESD leakage
current, resistors of up to 5k may be added in series with
the input. The effect of series resistance on the converter
accuracy can be evaluated from the curves presented in
the Input Current/Reference Current sections. In addition,
series resistors will introduce a temperature dependent
error due to input leakage current. A 1nA input leakage
current will develop a 1ppm offset error on a 5k resistor
if VREF = 5V. This error has a very strong temperature
dependency.
I2C INTERFACE
The LTC2489 communicates through an I2C interface. The
I2C interface is a 2-wire open-drain interface supporting
multiple devices and multiple masters on a single bus. The
connected devices can only pull the data line (SDA) low
and can never drive it high. SDA is required to be externally
connected to the supply through a pull-up resistor. When
the data line is not being driven, it is high. Data on the
I2C bus can be transferred at rates up to 100kbits/s in the
standard mode and up to 400kbits/s in the fast mode.
Each device on the I2C bus is recognized by a unique
address stored in that device and can operate either as a
transmitter or receiver, depending on the function of the
device. In addition to transmitters and receivers, devices
can also be considered as masters or slaves when performing data transfers. A master is the device which initiates a
data transfer on the bus and generates the clock signals
to permit that transfer. Devices addressed by the master
are considered a slave.
The LTC2489 can only be addressed as a slave. Once addressed, it can receive channel selection bits or transmit the
last conversion result. The serial clock line, SCL, is always
an input to the LTC2489 and the serial data line SDA is
bidirectional. The device supports the standard mode and
the fast mode for data transfer speeds up to 400kbits/s.
Figure 2 shows the definition of the I2C timing.
2489f
10
LTC2489
APPLICATIONS INFORMATION
SDA
tLOW
tf
tr
tSU(DAT)
tHD(SDA)
tf
tSP
tBUF
tr
SCL
tHD(SDA)
S
tHD(DAT)
tHIGH
tSU(STA)
tSU(STO)
Sr
P
S
2489 F02
Figure 2. Definition of Timing for Fast/Standard Mode Devices on the I2C Bus
The Start and Stop Conditions
A Start (S) condition is generated by transitioning SDA from
high to low while SCL is high. The bus is considered to be
busy after the Start condition. When the data transfer is
finished, a Stop (P) condition is generated by transitioning
SDA from low to high while SCL is high. The bus is free
after a Stop is generated. Start and Stop conditions are
always generated by the master.
When the bus is in use, it stays busy if a Repeated Start
(Sr) is generated instead of a Stop condition. The repeated
Start timing is functionally identical to the Start and is
used for writing and reading from the device before the
initiation of a new conversion.
Data Transferring
After the Start condition, the I2C bus is busy and data
transfer can begin between the master and the addressed
slave. Data is transferred over the bus in groups of nine
bits, one byte followed by one acknowledge (ACK) bit. The
master releases the SDA line during the ninth SCL clock
cycle. The slave device can issue an ACK by pulling SDA
low or issue a Not Acknowledge (NAK) by leaving the SDA
line high impedance (the external pull-up resistor will hold
the line high). Change of data only occurs while the clock
line (SCL) is low.
DATA FORMAT
After a Start condition, the master sends a 7-bit address
followed by a read/write (R/W) bit. The R/W bit is 1 for
a read request and 0 for a write request. If the 7-bit address matches the hard wired, LTC2489’s address (one of
9 pin-selectable addresses) the device is selected. When
the device is addressed during the conversion state, it will
not acknowledge R/W requests and will issue a NAK by
leaving the SDA line high. If the conversion is complete,
the LTC2489 issues an ACK by pulling the SDA line low.
The LTC2489 has two registers. The output register (24
bits long) contains the last conversion result. The input
register (8 bits long) sets the input channel.
DATA OUTPUT FORMAT
The output register contains the last conversion result.
After each conversion is completed, the device automatically enters the sleep state where the supply current is
reduced to 1μA. When the LTC2489 is addressed for a read
operation, it acknowledges (by pulling SDA low) and acts
as a transmitter. The master/receiver can read up to three
bytes from the LTC2489. After a complete read operation
(3 bytes), a new conversion is initiated. The device will
NAK subsequent read operations while a conversion is
being performed.
The data output stream is 24 bits long and is shifted out
on the falling edges of SCL (see Figure 3a). The first bit
is the conversion result sign bit (SIG) (see Tables 1 and
2). This bit is high if VIN ≥ 0 and low if VIN < 0 (where VIN
corresponds to the selected input signal IN+ – IN–). The
second bit is the most significant bit (MSB) of the result.
The first two bits (SIG and MSB) can be used to indicate
over and under range conditions (see Table 2). If both bits
are HIGH, the differential input voltage is equal to or above
+FS. If both bits are set low, the input voltage is below
–FS. The function of these bits is summarized in Table
2. The 16 bits following the MSB bit are the conversion
2489f
11
LTC2489
APPLICATIONS INFORMATION
Table 1. Output Data Format
Differential Input Voltage
VIN*
Bit 23
SIG
Bit 22
MSB
Bit 21
Bit 20
Bit 19
…
Bit 6
LSB
Bits 5-0
Always 0
VIN* ≥ FS**
1
1
0
0
0
…
0
000000
FS** – 1LSB
1
0
1
1
1
…
1
000000
0.5 • FS**
1
0
1
0
0
…
0
000000
0.5 • FS** – 1LSB
1
0
0
1
1
…
1
000000
0
1
0
0
0
0
…
0
000000
–1LSB
0
1
1
1
1
…
1
000000
–0.5 • FS**
0
1
1
0
0
…
0
000000
–0.5 • FS** – 1LSB
0
1
0
1
1
…
1
000000
–FS**
0
1
0
0
0
…
0
000000
VIN* < –FS**
0
0
1
1
1
…
1
000000
*The differential input voltage VIN = IN+ – IN–. **The full-scale voltage FS = 0.5 • VREF .
result in binary two’s complement format. The remaining
six bits are always 0.
conversion is complete, a new channel may be written
into the device.
As long as the voltage on the selected input channels (IN+
and IN–) remains between –0.3V and VCC + 0.3V (absolute
maximum operating range) a conversion result is generated for any differential input voltage VIN from –FS = –0.5
• VREF to +FS = 0.5 • VREF . For differential input voltages
greater than +FS, the conversion result is clamped to the
value corresponding to +FS. For differential input voltages
below –FS, the conversion result is clamped to the value
–FS – 1LSB.
The first three bits of the input word consist of two preamble bits and one enable bit. These three bits are used
to enable the input channel selection. Valid settings for
these three bits are 000, 100, and 101. Other combinations
should be avoided.
Table 2. LTC2489 Status Bits
Input Range
Bit 23
SIG
Bit 22
MSB
VIN ≥ FS
1
1
0V ≤ VIN < FS
1
0
–FS ≤ VIN < 0V
0
1
VIN < –FS
0
0
INPUT DATA FORMAT
The LTC2489 serial input is 8 bits long and is written into
the device in one 8-bit word. SGL, ODD, A2, A1, A0 are
used to select the input channel.
After power-up, the device initiates an internal reset cycle
which sets the input channel to CH0-CH1 (IN+ = CH0,
IN– = CH1). The first conversion automatically begins
at power-up using this default input channel. Once the
If the first three bits are 000 or 100, the following data
is ignored (don’t care) and the previously selected input
channel remains valid for the next conversion.
If the first three bits shifted into the device are 101, then
the next five bits select the input channel for the next
conversion cycle (see Table 3).
Table 3 Channel Selection
MUX ADDRESS
SGL
ODD/
SIGN
A2
A1
CHANNEL SELECTION
A0
0
1
IN+
IN–
*0
0
0
0
0
0
0
0
0
1
0
1
0
0
0
0
1
0
0
1
1
0
0
0
0
1
0
0
0
1
1
1
0
0
0
1
1
0
0
1
IN–
2
3
IN+
IN–
IN–
IN+
COM
IN+
IN+
IN–
IN+
IN–
IN+
IN–
IN+
IN–
*Default at power up
2489f
12
LTC2489
APPLICATIONS INFORMATION
1
SCL
…
7
8
9
1
2
SIG
MSB
9
…
1
2
3
4
5
6
7
8
9
SDA
7-BIT
ADDRESS
R
D23
ACK BY
LTC2489
START BY
MASTER
LSB
ACK BY
MASTER
NAK BY
MASTER
ALWAYS LOW
SLEEP
DATA OUTPUT
2489 F03a
Figure 3a. Timing Diagram for Reading from the LTC2489
1
SCL
2
…
7
8
1
9
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
SDA
7-BIT ADDRESS
1
W
0
EN
SGL ODD
ACK BY
LTC2489
START BY
MASTER
SLEEP
A2
A1
A0
X
ACK BY
LTC2489
DATA INPUT
X
X
X
X
X
X
X
NAK BY
LTC2489
2489 F03b
Figure 3b. Timing Diagram for Writing to the LTC2489
The first input bit (SGL) following the 101 sequence determines if the input selection is differential (SGL = 0) or
single-ended (SGL = 1). For SGL = 0, two adjacent channels can be selected to form a differential input. For SGL
= 1, one of 4 channels is selected as the positive input.
The negative input is COM for all single-ended operations.
The remaining four bits (ODD, A2, A1, A0) determine
which channel(s) is/are selected and the polarity (for a
differential input).
Initiating a New Conversion
When the LTC2489 finishes a conversion, it automatically
enters the sleep state. Once in the sleep state, the device is
ready for a read operation. After the device acknowledges
a read request, the device exits the sleep state and enters
the data output state. The data output state concludes
and the LTC2489 starts a new conversion once a Stop
condition is issued by the master or all 24 bits of data are
read out of the device.
During the data read cycle, a Stop command may be issued
by the master controller in order to start a new conversion
and abort the data transfer. This Stop command must be
issued during the ninth clock cycle of a byte read when
the bus is free (the ACK/NAK cycle).
LTC2489 Address
The LTC2489 has two address pins (CA0, CA1). Each may
be tied high, low, or left floating enabling one of 9 possible
addresses (see Table 4).
In addition to the configurable addresses listed in Table 4,
the LTC2489 also contains a global address (1110111)
which may be used for synchronizing multiple LTC2489s
or other LTC24XX delta-sigma I2C devices, (See Synchronizing Multiple LTC2489s with Global Address Call
section).
2489f
13
LTC2489
APPLICATIONS INFORMATION
Continuous Read
Table 4. Address Assignment
CA1
CA0
ADDRESS
LOW
LOW
0010100
LOW
HIGH
0010110
LOW
FLOAT
0010101
HIGH
LOW
0100110
HIGH
HIGH
0110100
HIGH
FLOAT
0100111
FLOAT
LOW
0010111
FLOAT
HIGH
0100101
FLOAT
FLOAT
0100100
In applications where the input channel does not need to
change for each cycle, the conversion can be continuously
performed and read without a write cycle (see Figure 5).
The input channel remains unchanged from the last
value written into the device. If the device has not been
written to since power up, the channel selection is set to
the default value of CH0 = IN+, CH1 = IN–. At the end of
a read operation, a new conversion automatically begins.
At the conclusion of the conversion cycle, the next result
may be read using the method described above. If the
conversion cycle is not concluded and a valid address
selects the device, the LTC2489 generates a NAK signal
indicating the conversion cycle is in progress.
Operation Sequence
The LTC2489 acts as a transmitter or receiver, as shown
in Figure 4. The device may be programmed to select
an input channel, differential or single-ended mode, and
channel polarity.
S
R/W
7-BIT ADDRESS
CONVERSION
ACK
SLEEP
DATA
Continuous Read/Write
Once the conversion cycle is concluded, the LTC2489 can
be written to and then read from using the Repeated Start
(Sr) command.
Sr
DATA TRANSFERRING
P
DATA INPUT/OUTPUT
CONVERSION
2489 F04
Figure 4. Conversion Sequence
S
7-BIT ADDRESS
CONVERSION
R ACK
SLEEP
READ
DATA INPUT
P
S
CONVERSION
7-BIT ADDRESS
R ACK
SLEEP
READ
DATA OUTPUT
P
CONVERSION
2489 F05
Figure 5. Consecutive Reading with the Same Input/Configuration
2489f
14
LTC2489
APPLICATIONS INFORMATION
Figure 6 shows a cycle which begins with a data Write,
a repeated Start, followed by a Read and concluded with
a Stop command. The following conversion begins after
all 24 bits are read out of the device or after a Stop command. The following conversion will be performed using
the newly programmed data.
Synchronizing Multiple LTC2489s with a Global
Address Call
In applications where several LTC2489s (or other I2C
delta-sigma ADCs from Linear Technology Corporation)
are used on the same I2C bus, all converters can be synchronized through the use of a global address call. Prior
to issuing the global address call, all converters must have
completed a conversion cycle. The master then issues a
Start, followed by the global address 1110111, and a write
request. All converters will be selected and acknowledge
the request. The master then sends a write byte (optional)
followed by the Stop command. This will update the channel selection (optional) and simultaneously initiate a start
of conversion for all delta-sigma ADCs on the bus (see
Figure 8). In order to synchronize multiple converters
Discarding a Conversion Result and Initiating a New
Conversion with Optional Write
At the conclusion of a conversion cycle, a write cycle
can be initiated. Once the write cycle is acknowledged, a
Stop command will start a new conversion. If a new input
channel is required, this data can be written into the device
and a Stop command will initiate the next conversion (see
Figure 7).
S
7-BIT ADDRESS
CONVERSION
W ACK
SLEEP
WRITE
Sr
7-BIT ADDRESS
DATA INPUT
R ACK
ADDRESS
READ
DATA OUTPUT
P
CONVERSION
2489 F06
Figure 6. Write, Read, Start Conversion
S
7-BIT ADDRESS
CONVERSION
W ACK
SLEEP
WRITE (OPTIONAL)
DATA INPUT
P
CONVERSION
2489 F07
Figure 7. Start a New Conversion Without Reading Old Conversion Result
SCL
SDA
LTC2489
S
LTC2489
GLOBAL ADDRESS
W ACK
…
WRITE (OPTIONAL)
ALL LTC2489s IN SLEEP
LTC2489
P
CONVERSION OF ALL LTC2489s
DATA INPUT
2489 F08
Figure 8. Synchronize Multiple LTC2489s with a Global Address Call
2489f
15
LTC2489
APPLICATIONS INFORMATION
without changing the channel, a Stop may be issued after
acknowledgement of the global write command. Global
read commands are not allowed and the converters will
NAK a global read request.
completely; however, the addition of external capacitors
at the input terminals in order to filter unwanted noise
(antialiasing) results in incomplete settling.
Automatic Differential Input Current Cancellation
Driving the Input and Reference
In applications where the sensor output impedance is
low (up to 10kΩ with no external bypass capacitor or up
to 500Ω with 0.001μF bypass), complete settling of the
input occurs. In this case, no errors are introduced and
direct digitization is possible.
The input and reference pins of the LTC2489 are connected
directly to a switched capacitor network. Depending on
the relationship between the differential input voltage and
the differential reference voltage, these capacitors are
switched between these four pins. Each time a capacitor
is switched between two of these pins, a small amount
of charge is transferred. A simplified equivalent circuit is
shown in Figure 9.
For many applications, the sensor output impedance
combined with external input bypass capacitors produces
RC time constants much greater than the 580ns required
for 1ppm accuracy. For example, a 10kΩ bridge driving a
0.1μF capacitor has a time constant an order of magnitude
greater than the required maximum.
When using the LTC2489’s internal oscillator, the input
capacitor array is switched at 123kHz. The effect of the
charge transfer depends on the circuitry driving the input/reference pins. If the total external RC time constant
is less than 580ns the errors introduced by the sampling
process are negligible since complete settling occurs.
The LTC2489 uses a proprietary switching algorithm
that forces the average differential input current to zero
independent of external settling errors. This allows direct
digitization of high impedance sensors without the need
for buffers.
Typically, the reference inputs are driven from a low
impedance source. In this case, complete settling occurs
even with large external bypass capacitors. The inputs
(CH0-CH3, COM), on the other hand, are typically driven
from larger source resistances. Source resistances up
to 10k may interface directly to the LTC2489 and settle
IIN+
IN+
INPUT
MULTIPLEXER
100Ω
The switching algorithm forces the average input current
on the positive input (IIN+) to be equal to the average input
current on the negative input (IIN–). Over the complete
conversion cycle, the average differential input current
(IIN+ – IIN–) is zero. While the differential input current is
INTERNAL
SWITCH
NETWORK
( )
I IN+
10kΩ
AVG
(
I REF +
IIN–
100Ω
CEQ
12μF
10kΩ
(
0.5 • REQ
1.5VREF + VREF(CM) – VIN(CM)
0.5 • REQ
)–
VIN2
VREF • REQ
⎛ REF + – REF − ⎞
VREF(CM) = ⎜
⎟
⎜⎝
⎟⎠
2
VIN = IN+ − IN− , WHERE IN+ AND IN− ARE THE SELECTED INPUT CHANNELS
⎛ IN+ – IN− ⎞
VIN(CM) = ⎜
⎟
⎜⎝
⎟⎠
2
REQ = 2.98MΩ INTERNAL OSCILLATOR
IREF–
10kΩ
SWITCHING FREQUENCY
fSW = 123kHz INTERNAL OSCILLATOR
fSW = 0.4 • fEOSC EXTERNAL OSCILLATOR
≈
VIN(CM) − VREF(CM)
=
VREF = REF + − REF −
IREF+
REF–
AVG
AVG
where :
10kΩ
IN–
REF+
)
( )
= I IN–
2489 F09
(
)
REQ = 0.833 • 1012 /fEOSC EXTERNAL OSCILLATOR
Figure 9. Equivalent Analog Input Circuit
2489f
16
LTC2489
APPLICATIONS INFORMATION
zero, the common mode input current (IIN+ + IIN–)/2 is
proportional to the difference between the common mode
input voltage (VIN(CM)) and the common mode reference
voltage (VREF(CM)).
In applications where the input common mode voltage is
equal to the reference common mode voltage, as in the
case of a balanced bridge, both the differential and common mode input current are zero. The accuracy of the
converter is not compromised by settling errors.
In applications where the input common mode voltage is
constant but different from the reference common mode
voltage, the differential input current remains zero while
the common mode input current is proportional to the
difference between VIN(CM) and VREF(CM). For a reference
common mode voltage of 2.5V and an input common
mode of 1.5V, the common mode input current is approximately 0.74μA. This common mode input current
does not degrade the accuracy if the source impedances
tied to IN+ and IN– are matched. Mismatches in source
impedance lead to a fixed offset error but do not effect
the linearity or full-scale reading. A 1% mismatch in a 1k
source resistance leads to a 74μV shift in offset voltage.
In applications where the common mode input voltage
varies as a function of the input signal level (single-ended
type sensors), the common mode input current varies
proportionally with input voltage. For the case of balanced
input impedances, the common mode input current effects
are rejected by the large CMRR of the LTC2489, leading
90
60
50
30
10
0
0
10
For relatively small values of external reference capacitance
(CREF < 1nF), the voltage on the sampling capacitor settles
for reference impedances of many kΩ (if CREF = 100pF up
to 10kΩ will not degrade the performance) (see Figures
10 and 11).
0
20
–10
Similar to the analog inputs, the LTC2489 samples the
differential reference pins (REF+ and REF–) transferring
small amounts of charge to and from these pins, thus
producing a dynamic reference current. If incomplete settling occurs (as a function the reference source resistance
and reference bypass capacitance) linearity and gain errors
are introduced.
–10
CREF = 0.01μF
CREF = 0.001μF
CREF = 100pF
CREF = 0pF
40
Reference Current
–FS ERROR (ppm)
+FS ERROR (ppm)
70
In addition to the input sampling current, the input ESD
protection diodes have a temperature dependent leakage
current. This current, nominally 1nA (±10nA max), results
in a small offset shift. A 1k source resistance will create a
1μV typical and a 10μV maximum offset voltage.
10
VCC = 5V
VREF = 5V
VIN+ = 3.75V
VIN– = 1.25V
FO = GND
TA = 25°C
80
to little degradation in accuracy. Mismatches in source
impedances lead to gain errors proportional to the difference between the common mode input and common
mode reference. 1% mismatches in 1k source resistances
lead to gain errors on the order of 15ppm. Based on the
stability of the internal sampling capacitors and the accuracy of the internal oscillator, a one-time calibration will
remove this error.
1k
100
RSOURCE (Ω)
10k
100k
2489 F10
Figure 10. +FS Error vs RSOURCE at VREF (Small CREF)
–20
–30
CREF = 0.01μF
CREF = 0.001μF
CREF = 100pF
CREF = 0pF
–40
–50
VCC = 5V
–60 VREF = 5V
V + = 1.25V
–70 VIN– = 3.75V
IN
–80 FO = GND
TA = 25°C
–90
10
0
1k
100
RSOURCE (Ω)
10k
100k
2489 F11
Figure 11. –FS Error vs RSOURCE at VREF (Small CREF)
2489f
17
LTC2489
APPLICATIONS INFORMATION
In cases where large bypass capacitors are required on
the reference inputs (CREF > .01μF), full-scale and linearity errors are proportional to the value of the reference
resistance. Every ohm of reference resistance produces
a full-scale error of approximately 0.5ppm (while operating with the internal oscillator) (see Figures 12 and 13). If
the input common mode voltage is equal to the reference
common mode voltage, a linearity error of approximately
0.67ppm per 100Ω of reference resistance results (see
Figure 14). In applications where the input and reference
common mode voltages are different, the errors increase.
A 1V difference in between common mode input and
common mode reference results in a 6.7ppm INL error
for every 100Ω of reference resistance.
VCC = 5V
VREF = 5V
VIN+ = 3.75V
VIN– = 1.25V
FO = GND
TA = 25°C
+FS ERROR (ppm)
400
300
Normal Mode Rejection and Antialiasing
One of the advantages delta-sigma ADCs offer over
conventional ADCs is on-chip digital filtering. Combined
with a large oversample ratio, the LTC2489 significantly
simplifies antialiasing filter requirements. Additionally,
the input current cancellation feature allows external low
pass filtering without degrading the DC performance of
the device.
0
CREF = 1μF, 10μF
–100
–FS ERROR (ppm)
500
In addition to the reference sampling charge, the reference
ESD protection diodes have a temperature dependent leakage current. This leakage current, nominally 1nA (±10nA
max) results in a small, gain error. A 100Ω reference
resistance will create a 0.5μV full-scale error.
CREF = 0.1μF
200
CREF = 0.01μF
–200
CREF = 1μF, 10μF
–300
VCC = 5V
VREF = 5V
VIN+ = 1.25V
VIN– = 3.75V
FO = GND
TA = 25°C
CREF = 0.01μF
–400
100
0
–500
0
200
600
400
RSOURCE (Ω)
800
1000
0
200
CREF = 0.1μF
600
400
RSOURCE (Ω)
800
1000
2489 F13
2489 F12
Figure 12. +FS Error vs RSOURCE at VREF (Large CREF)
Figure 13. –FS Error vs RSOURCE at VREF (Large CREF)
INL (ppm OF VREF)
10
VCC = 5V
8 VREF = 5V
VIN(CM) = 2.5V
6 T = 25°C
A
4 CREF = 10μF
R = 1k
2
R = 500Ω
0
R = 100Ω
–2
–4
–6
–8
–10
– 0.5
– 0.3
0.1
– 0.1
VIN/VREF
0.3
0.5
2489 F14
Figure 14. INL vs Differential Input Voltage and
Reference Source Resistance for CREF > 1μF
2489f
18
LTC2489
APPLICATIONS INFORMATION
When using the internal oscillator, the LTC2489 is designed
to reject line frequencies. As shown in Figure 15, rejection
nulls occur at multiples of frequency fN, where fN = 55Hz
for simultaneous 50Hz/60Hz rejection. Multiples of the
modulator sampling rate (fS = fN • 256) only reject noise
to 15dB (see Figure 16); if noise sources are present at
these frequencies antialiasing will reduce their effects.
The user can expect to achieve this level of performance
using the internal oscillator, as shown in Figure 17.
Measured values of normal mode rejection are shown
superimposed over the theoretical values.
INPUT NORMAL MODE REJECTION (dB)
0
fN = fEOSC/5120
–10
–20
–30
–40
–50
–60
–70
–80
–90
–100
–110
–120
0
fN
2fN 3fN 4fN 5fN 6fN 7fN
INPUT SIGNAL FREQUENCY (Hz)
8fN
2489 F15
Figure 15. Input Normal Mode Rejection at DC
Traditional high order delta-sigma modulators suffer
from potential instabilities at large input signal levels. The
proprietary architecture used for the LTC2489 third order
modulator resolves this problem and guarantees stability
with input signals 150% of full scale. In many industrial
applications, it is not uncommon to have microvolt level
signals superimposed over unwanted error sources with
several volts if peak-to-peak noise. Figure 18 shows measurement results for the rejection of a 7.5V peak-to-peak
noise source (150% of full scale) applied to the LTC2489.
This curve shows that the rejection performance is maintained even in extremely noisy environments.
Output Data Rate
When using its internal oscillator, the LTC2489 produces
up to 7.5 samples per second (sps) with a notch frequency
of 60Hz. The actual output data rate depends upon the length
of the sleep and data output cycles which are controlled
0
INPUT NORMAL MODE REJECTION (dB)
The SINC4 digital filter provides excellent normal mode
rejection at all frequencies except DC and integer multiples
of the modulator sampling frequency (fS). The modulator
sampling frequency is fS = 15,360Hz while operating with
its internal oscillator and fS = fEOSC/20 when operating with
an external oscillator of frequency fEOSC .
–10
fN = fEOSC/5120
–20
–30
–40
–50
–60
–70
–80
–90
–100
–110
–120
250fN 252fN 254fN 256fN 258fN 260fN 262fN
INPUT SIGNAL FREQUENCY (Hz)
2489 F16
Figure 16. Input Normal Mode Rejection at fS = 256 • fN
2489f
19
LTC2489
APPLICATIONS INFORMATION
MEASURED DATA
CALCULATED DATA
–20
–40
VCC = 5V
VREF = 5V
VIN(CM) = 2.5V
VIN(P-P) = 5V
TA = 25°C
– 60
–80
–100
–120
0
12.5 25 37.5 50 62.5 75 87.5 100 112.5 125 137.5 150 162.5 175 187.5 200
INPUT FREQUENCY (Hz)
0
NORMAL MODE REJECTION (dB)
NORMAL MODE REJECTION (dB)
0
VIN(P-P) = 5V
VIN(P-P) = 7.5V
(150% OF FULL SCALE)
–20
VCC = 5V
VREF = 5V
VIN(CM) = 2.5V
TA = 25°C
–40
– 60
–80
–100
–120
0
15
30
45
60
75
90 105 120 135 150 165 180 195 210 225 240
INPUT FREQUENCY (Hz)
2489 F18
2489 F17
Figure 17. Input Normal Mode Rejection vs Input Frequency with
Input Perturbation of 100% (50Hz/60Hz Notch)
Figure 18. Measure Input Normal Mode Rejection vs Input
Frequency with Input Perturbation of 150% (60Hz Notch)
by the user and can be made insignificantly short. When
operating with an external conversion clock (fO connected
to an external oscillator), the LTC2489 output data rate
can be increased. The duration of the conversion cycle is
41036/fEOSC. If fEOSC = 307.2kHz, the converter behaves
as if the internal oscillator is used.
rejection of line frequencies remains unchanged, thus fully
differential input signals with a high degree of symmetry
on both the IN+ and IN– pins will continue to reject line
frequency noise.
An increase in fEOSC over the nominal 307.2kHz will translate into a proportional increase in the maximum output
data rate (up to a maximum of 100sps). The increase in
output rate leads to degradation in offset, full-scale error,
and effective resolution as well as a shift in frequency
rejection.
A change in fEOSC results in a proportional change in the
internal notch position. This leads to reduced differential
mode rejection of line frequencies. The common mode
An increase in fEOSC also increases the effective dynamic
input and reference current. External RC networks will
continue to have zero differential input current, but the
time required for complete settling (580ns for fEOSC =
307.2kHz) is reduced, proportionally.
Once the external oscillator frequency is increased above
1MHz (a more than 3X increase in output rate) the effectiveness of internal auto calibration circuits begins to degrade.
This results in larger offset errors, full-scale errors, and
decreased resolution, as shown in Figures 19 to 26.
2489f
20
LTC2489
APPLICATIONS INFORMATION
40
3000
30
TA = 85°C
20
10
–500
2500
TA = 85°C
1500
TA = 25°C
1000
–10
–3500
Figure 21.–FS Error vs Output Data
Rate and Temperature
Figure 20. +FS Error vs Output Data
Rate and Temperature
18
20
TA = 25°C, 85°C
RESOLUTION (BITS)
14
VIN(CM) = VREF(CM)
VCC = VREF = 5V
VIN = 0V
FO = EXT CLOCK
RES = LOG 2 (VREF/NOISERMS)
10
0 10 20 30 40 50 60 70 80 90 100
OUTPUT DATA RATE (READINGS/SEC)
16
TA = 25°C
TA = 85°C
14
12 VIN(CM) = VREF(CM)
VCC = VREF = 5V
FO = EXT CLOCK
RES = LOG 2 (VREF/INLMAX)
10
0 10 20 30 40 50 60 70 80 90 100
OUTPUT DATA RATE (READINGS/SEC)
2489 F22
Figure 22. Resolution (NoiseRMS ≤ 1LSB)
vs Output Data Rate and Temperature
VIN(CM) = VREF(CM)
VIN = 0V
15 FO = EXT CLOCK
TA = 25°C
10
VCC = VREF = 5V
5
0
–5
VCC = 5V, VREF = 2.5V
–10
0 10 20 30 40 50 60 70 80 90 100
OUTPUT DATA RATE (READINGS/SEC)
2489 F23
Figure 23. Resolution (INLMAX ≤ 1LSB)
vs Output Data Rate and Temperature
18
2489 F24
Figure 24. Offset Error vs Output
Data Rate and Temperature
18
16
VCC = 5V, VREF = 2.5V, 5V
14
VIN(CM) = VREF(CM)
12 VIN = 0V
FO = EXT CLOCK
TA = 25°C
RES = LOG 2 (VREF/NOISERMS)
10
0 10 20 30 40 50 60 70 80 90 100
OUTPUT DATA RATE (READINGS/SEC)
2489 F25
Figure 25. Resolution (NoiseRMS ≤ 1LSB)
vs Output Data Rate and Temperature
RESOLUTION (BITS)
RESOLUTION (BITS)
OFFSET ERROR (ppm OF VREF)
18
RESOLUTION (BITS)
2489 F21
2489 F20
Figure 19. Offset Error vs Output Data
Rate and Temperature
16
VIN(CM) = VREF(CM)
VCC = VREF = 5V
FO = EXT CLOCK
0 10 20 30 40 50 60 70 80 90 100
OUTPUT DATA RATE (READINGS/SEC)
0 10 20 30 40 50 60 70 80 90 100
OUTPUT DATA RATE (READINGS/SEC)
2489 F19
12
TA = 85°C
–2000
–3000
0
10 20 30 40 50 60 70 80 90 100
OUTPUT DATA RATE (READINGS/SEC)
TA = 25°C
–2500
500
TA = 25°C
–1000
–1500
2000
0
0
0
VIN(CM) = VREF(CM)
VCC = VREF = 5V
FO = EXT CLOCK
–FS ERROR (ppm OF VREF)
3500
VIN(CM) = VREF(CM)
VCC = VREF = 5V
VIN = 0V
FO = EXT CLOCK
+FS ERROR (ppm OF VREF)
OFFSET ERROR (ppm OF VREF)
50
VCC = VREF = 5V
16
VCC = 5V, VREF = 2.5V
14
VIN(CM) = VREF(CM)
VIN = 0V
12 REF– = GND
FO = EXT CLOCK
TA = 25°C
RES = LOG 2 (VREF/INLMAX)
10
0 10 20 30 40 50 60 70 80 90 100
OUTPUT DATA RATE (READINGS/SEC)
2489 F26
Figure 26. Resolution (INLMAX ≤ 1LSB)
vs Output Data Rate and Temperature
2489f
21
LTC2489
APPLICATIONS INFORMATION
Easy Drive ADCs Simplify Measurement of High
Impedance Sensors
Delta-Sigma ADCs, with their high accuracy and high noise
immunity, are ideal for directly measuring many types
of sensors. Nevertheless, input sampling currents can
overwhelm high source impedances or low-bandwidth,
micropower signal conditioning circuits. The LTC2489
solves this problem by balancing the input currents, thus
simplifying or eliminating the need for signal conditioning
circuits.
A common application for a delta-sigma ADC is thermistor
measurement. Figure 27 shows two examples of thermistor
digitization benefiting from the Easy Drive technology.
The first circuit (applied to input channels CH0 and CH1)
uses balanced reference resistors in order to balance the
common mode input/reference voltage and balance the
differential input source resistance. If reference resistors
R1 and R4 are exactly equal, the input current is zero and
no errors result. If these resistors have a 1% tolerance,
the maximum error in measured resistance is 1.6Ω due
to a shift in common mode voltage; far less than the 1%
error of the reference resistors themselves. No amplifier
is required, making this an ideal solution in micropower
applications.
Easy Drive also enables very low power, low bandwidth
amplifiers to drive the input to the LTC2489. As shown
in Figure 27, CH2 is driven by the LT1494. The LT1494
has excellent DC specs for an amplifier with 1.5μA supply
current (the maximum offset voltage is 150μV and the
open loop gain is 100,000). Its 2kHz bandwidth makes
it unsuitable for driving conventional delta sigma ADCs.
Adding a 1kΩ, 0.1μF filter solves this problem by providing
a charge reservoir that supplies the LTC2489 instantaneous
current, while the 1k resistor isolates the capacitive load
from the LT1494.
Conventional delta sigma ADCs input sampling current
lead to DC errors as a result of incomplete settling in the
external RC network.
The Easy Drive technology cancels the differential input
current. By balancing the negative input (CH3) with a 1kΩ,
0.1μF network errors due to the common mode input
current are cancelled.
2489f
22
LTC2489
PACKAGE DESCRIPTION
DE Package
14-Lead Plastic DFN (4mm × 3mm)
(Reference LTC DWG # 05-08-1708 Rev B)
0.70 ±0.05
3.30 ±0.05
3.60 ±0.05
2.20 ±0.05
1.70 ± 0.05
PACKAGE
OUTLINE
0.25 ± 0.05
0.50 BSC
3.00 REF
RECOMMENDED SOLDER PAD PITCH AND DIMENSIONS
APPLY SOLDER MASK TO AREAS THAT ARE NOT SOLDERED
R = 0.115
TYP
4.00 ±0.10
(2 SIDES)
R = 0.05
TYP
3.00 ±0.10
(2 SIDES)
8
0.40 ± 0.10
14
3.30 ±0.10
1.70 ± 0.10
PIN 1 NOTCH
R = 0.20 OR
0.35 × 45°
CHAMFER
PIN 1
TOP MARK
(SEE NOTE 6)
(DE14) DFN 0806 REV B
7
0.200 REF
1
0.25 ± 0.05
0.50 BSC
0.75 ±0.05
3.00 REF
0.00 – 0.05
BOTTOM VIEW—EXPOSED PAD
NOTE:
1. DRAWING PROPOSED TO BE MADE VARIATION OF VERSION (WGED-3) IN JEDEC
PACKAGE OUTLINE MO-229
2. DRAWING NOT TO SCALE
3. ALL DIMENSIONS ARE IN MILLIMETERS
4. DIMENSIONS OF EXPOSED PAD ON BOTTOM OF PACKAGE DO NOT INCLUDE
MOLD FLASH. MOLD FLASH, IF PRESENT, SHALL NOT EXCEED 0.15mm ON ANY SIDE
5. EXPOSED PAD SHALL BE SOLDER PLATED
6. SHADED AREA IS ONLY A REFERENCE FOR PIN 1 LOCATION ON THE
TOP AND BOTTOM OF PACKAGE
2489f
Information furnished by Linear Technology Corporation is believed to be accurate and reliable.
However, no responsibility is assumed for its use. Linear Technology Corporation makes no representation that the interconnection of its circuits as described herein will not infringe on existing patent rights.
23
LTC2489
TYPICAL APPLICATION
5V
5V
R1
51.1k
C4
0.1μF
12
10μF
IIN+ = 0
R3
10k TO 100k
0.1μF
14
8
9
10
5V
102k
11
+
0.1μF
10k TO 100k
7
1k
LT1494
REF–
5
SDA
4
2-WIRE
I2C INTERFACE
CH0
CH1
CA0
CH2
CA1
2
3
9-PIN SELECTABLE
ADDRESSES
CH3
COM
GND
6
2489 F38
0.1μF
–
1.7k
REF +
SCL
5V
= EXTERNAL OSCILLATOR
= INTERNAL OSCILLATOR
1
FO
LTC2489
13
R4
IIN– = 0
51.1k
C3
0.1μF
VCC
1k
0.1μF
Figure 27. Easy Drive ADCs Simplify Measurement of High Impedance Sensors
RELATED PARTS
PART NUMBER
DESCRIPTION
COMMENTS
LT1236A-5
Precision Bandgap Reference, 5V
0.05% Max Initial Accuracy, 5ppm/°C Drift
LT1460
Micropower Series Reference
0.075% Max Initial Accuracy, 10ppm/°C Max Drift
LT1790
Micropower SOT-23 Low Dropout Reference Family
0.05% Max Initial Accuracy, 10ppm/°C Max Drift
LTC2400
24-bit, No Latency ΔΣ ADC in SO-8
0.3ppm Noise, 4ppm INL, 10ppm Total Unadjusted Error, 200μA
LTC2410
24-bit, No Latency ΔΣ ADC with Differential Inputs
0.8μVRMS Noise, 2ppm INL
LTC2440
High Speed, Low Noise 24-bit ΔΣ ADC
3.5kHz Output Rate, 200nV Noise, 24.6 ENOBs
LTC2442
24-Bit, High Speed, 4-Channel/2-Channel ΔΣ ADC with
Integrated Amplifier
8kHz Output Rate, 220nV Noise, Simultaneous 50Hz/60Hz Rejection
LTC2449
24-Bit, High Speed, 8-Channel/16-Channel ΔΣ ADC
8kHz Output Rate, 200nV Noise, Simultaneous 50Hz/60Hz Rejection
LTC2480/LTC2482/ 16-/24-Bit ΔΣ ADCs with Easy Drive Inputs, 600nV Noise,
LTC2484
Programmable Gain, and Temperature Sensor
Pin Compatible 16-Bit and 24-Bit Versions
LTC2481/LTC2483/ 16-/24-Bit ΔΣ ADCs with Easy Drive Inputs, 600nV Noise, I2C
Interface, Programmable Gain, and Temperature Sensor
LTC2485
Pin Compatible 16-Bit and 24-Bit Versions
LTC2486/LTC2488/ 16-Bit/24-Bit 2-/4-Channel ΔΣ ADC with Easy Drive Inputs, SPI Pin-Compatible 16-Bit and 24-Bit Versions
LTC2492
Interface, Programmable Gain, and Temperature Sensor
LTC2487
16-Bit 2-/4-Channel ΔΣ ADC with Easy Drive Inputs and
I2C Interface
Pin-Compatible LTC2493/LTC2489
LTC2493
24-Bit 2-/4-Channel ΔΣ ADC with Easy Drive Inputs,
I2C Interface and Temperature Sensor
Pin Compatible LTC2487/LTC2489
LTC2495/LTC2497/ 16-Bit/24-Bit 8-/16-Channel ΔΣ ADC with Easy Drive Inputs and Pin-Compatible 16-Bit and 24-Bit Versions
LTC2499
I2C Interface, Programmable Gain, and Temperature Sensor
LTC2496/LTC2498 16-Bit 8-/16-Channel ΔΣ ADC with Easy Drive Inputs and
SPI Interface
Pin-Compatible with LTC2449/LTC2494
2489f
24 Linear Technology Corporation
LT 0307 • PRINTED IN USA
1630 McCarthy Blvd., Milpitas, CA 95035-7417
(408) 432-1900 ● FAX: (408) 434-0507
●
www.linear.com