LTC2424/LTC2428 4-/8-Channel 20-Bit µPower No Latency ∆ΣTM ADCs U FEATURES ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ DESCRIPTIO The LTC®2424/LTC2428 are 4-/8-channel 2.7V to 5.5V micropower 20-bit A/D converters with an integrated oscillator, 8ppm INL and 1.2ppm RMS noise. They use delta-sigma technology and provide single cycle digital filter settling time (no latency delay) for multiplexed applications. The first conversion after the channel is changed is always valid. Through a single pin the LTC2424/ LTC2428 can be configured for better than 110dB rejection at 50Hz or 60Hz ±2%, or can be driven by an external oscillator for a user defined rejection frequency in the range 1Hz to 800Hz. The internal oscillator requires no external frequency setting components. Pin Compatible 4-/8-Channel 20-Bit ADCs 8ppm INL, No Missing Codes at 20 Bits 4ppm Full-Scale Error and 0.5ppm Offset 1.2ppm Noise Digital Filter Settles in a Single Cycle. Each Conversion is Accurate, Even After Changing Channels Fast Mode: 16-Bit Noise, 12-Bit TUE at 100sps Internal Oscillator—No External Components Required 110dB Min, 50Hz/60Hz Notch Filter Reference Input Voltage: 0.1V to VCC Live Zero—Extended Input Range Accommodates 12.5% Overrange and Underrange Single Supply 2.7V to 5.5V Operation Low Supply Current (200µA) and Auto Shutdown Can Be Interchanged with 24-Bit LTC2404/LTC2408 if ZSSET Pin is Grounded The converters accept any external reference voltage from 0.1V to VCC. With their extended input conversion range of –12.5% VREF to 112.5% VREF (VREF = FSSET – ZSSET) the LTC2424/LTC2428 smoothly resolve the offset and overrange problems of preceding sensors or signal conditioning circuits. U APPLICATIO S ■ ■ ■ ■ ■ ■ ■ ■ The LTC2424/LTC2428 communicate through a flexible 4-wire digital interface which is compatible with SPI and MICROWIRETM protocols. Weight Scales Direct Temperature Measurement Gas Analyzers Strain-Gage Transducers Instrumentation Data Acquisition Industrial Process Control 4-Digit DVMs , LTC and LT are registered trademarks of Linear Technology Corporation. No Latency ∆Σ is a trademark of Linear Technology Corporation. MICROWIRE is a trademark of National Semiconductor Corporation. U TYPICAL APPLICATIO Total Unadjusted Error (3V Supply) 10 0.1V TO VCC 4 ADCIN 2.7V TO 5.5V 3 2, 8 FSSET VCC 9 CH0 ANALOG INPUTS –0.12VREF TO 1.12VREF 10 CH1 CSADC 11 CH2 CSMUX 12 CH3 13 CH4* 14 CH5* 15 CH6* 17 CH7* 4-/8-CHANNEL MUX + 20-BIT ∆Σ ADC SCK CLK DIN – SDO 23 20 25 GND 1, 6, 16, 18, 22, 27, 28 *THESE PINS ARE NO CONNECTS ON THE LTC2404 MPU 21 24248 TA01 26 2 0 –2 TA = –55°C, –45°C, 25°C, 90°C –6 VCC FO 4 –4 24 LTC2424/LTC2428 5 ZSSET 6 SERIAL DATA LINK MICROWIRE AND SPI COMPATABLE 19 VCC = 3V VREF = 2.5V 8 1µF ERROR (ppm) 7 MUXOUT = INTERNAL OSC/50Hz REJECTION = EXTERNAL CLOCK SOURCE = INTERNAL OSC/60Hz REJECTION –8 –10 0 0.5 1.5 2.0 1.0 INPUT VOLTAGE (V) 2.5 24248 G01 1 LTC2424/LTC2428 W W U W ABSOLUTE MAXIMUM RATINGS (Notes 1, 2) Supply Voltage (VCC) to GND .......................– 0.3V to 7V Analog Input Voltage to GND ....... – 0.3V to (VCC + 0.3V) Reference Input Voltage to GND .. – 0.3V to (VCC + 0.3V) Digital Input Voltage to GND ........ – 0.3V to (VCC + 0.3V) Digital Output Voltage to GND ..... – 0.3V to (VCC + 0.3V) Operating Temperature Range LTC2424C/LTC2428C .............................. 0°C to 70°C LTC2424I/LTC2428I ........................... – 40°C to 85°C Storage Temperature Range ................. – 65°C to 150°C Lead Temperature (Soldering, 10 sec).................. 300°C U W U PACKAGE/ORDER INFORMATION ORDER PART NUMBER TOP VIEW GND 1 28 GND VCC 2 27 GND FSSET 3 26 FO ADCIN 4 25 SCK ZSSET 5 24 SDO LTC2424CG LTC2424IG GND 6 23 CSADC MUXOUT 7 22 GND VCC 8 CH0 9 ORDER PART NUMBER TOP VIEW GND 1 28 GND VCC 2 27 GND FSSET 3 26 FO ADCIN 4 25 SCK ZSSET 5 24 SDO GND 6 23 CSADC MUXOUT 7 22 GND 21 DIN VCC 8 21 DIN 20 CSMUX CH0 9 20 CSMUX CH1 10 19 CLK CH1 10 19 CLK CH2 11 18 GND CH2 11 18 GND CH3 12 17 NC CH3 12 17 CH7 NC 13 16 GND CH4 13 16 GND NC 14 15 NC CH5 14 15 CH6 G PACKAGE 28-LEAD PLASTIC SSOP G PACKAGE 28-LEAD PLASTIC SSOP TJMAX = 125°C, θJA = 130°C/W TJMAX = 125°C, θJA = 130°C/W LTC2428CG LTC2428IG Consult factory for parts specified with wider operating temperature ranges. U CONVERTER CHARACTERISTICS The ● denotes specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25°C. (Notes 3, 4) PARAMETER CONDITIONS Resolution (No Missing Codes) 0.1V ≤ VREF ≤ VCC, (Note 5) ● Integral Nonlinearity VREF = 2.5V (Note 6) VREF = 5V (Note 6) ● ● 4 8 10 20 ppm of VREF ppm of VREF Integral Nonlinearity (Fast Mode) 2.5V < VREF < VCC, 100 Samples/Second, fO = 2.051MHz ● 40 250 ppm of VREF Offset Error 2.5V ≤ VREF ≤ VCC ● 0.5 10 ppm of VREF Offset Error (Fast Mode) 2.5V < VREF < 5V, 100 Samples/Second, fO = 2.051MHz Offset Error Drift 2.5V ≤ VREF ≤ VCC Full-Scale Error 2.5V ≤ VREF ≤ VCC Full-Scale Error (Fast Mode) 2.5V < VREF < 5V, 100 Samples/Second, fO = 2.051MHz Full-Scale Error Drift 2.5V ≤ VREF ≤ VCC 2 MIN TYP MAX 20 Bits 3 ppm of VREF 0.04 ● UNITS 4 10 0.04 ppm of VREF/°C 15 ppm of VREF ppm of VREF ppm of VREF/°C LTC2424/LTC2428 U CONVERTER CHARACTERISTICS The ● denotes specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25°C. (Notes 3, 4) PARAMETER CONDITIONS Total Unadjusted Error VREF = 2.5V VREF = 5V MIN TYP MAX UNITS Output Noise VIN = 0V, VREF = 5V (Note 13) 6 µVRMS Output Noise (Fast Mode) VREF = 5V, 100 Samples/Second, fO = 2.051MHz 20 µVRMS Normal Mode Rejection 60Hz ±2% (Note 7) ● 110 130 dB Normal Mode Rejection 50Hz ±2% (Note 8) ● 110 130 dB Power Supply Rejection, DC VREF = 2.5V, VIN = 0V 100 dB Power Supply Rejection, 60Hz ±2% VREF = 2.5V, VIN = 0V, (Notes 7, 16) 110 dB Power Supply Rejection, 50Hz ±2% VREF = 2.5V, VIN = 0V, (Notes 8, 16) 110 dB 8 16 ppm of VREF ppm of VREF U U U U A ALOG I PUT A D REFERE CE The ● denotes specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25°C. (Note 3) SYMBOL PARAMETER CONDITIONS VIN Input Voltage Range (Note 14) MIN TYP VREF Reference Voltage Range CS(IN) Input Sampling Capacitance CS(REF) Reference Sampling Capacitance IIN(LEAK) Input Leakage Current CS = VCC ● –100 1 IREF(LEAK) Reference Leakage Current VREF = 2.5V, CS = VCC ● – 100 1 IIN(MUX) On Channel Leakage Current VS = 2.5V (Note 15) ● RON MUX On-Resistance IOUT = 1mA, VCC = 2.7V IOUT = 1mA, VCC = 5V ● ● MAX UNITS ● – 0.125 • VREF 1.125 • VREF V ● 0.1 VCC V 1 pF 1.5 pF 250 120 100 nA 100 nA ±20 nA 300 250 Ω Ω MUX ∆RON vs Temperature 0.5 %/°C ∆RON vs VS (Note 15) 20 % IS(OFF) MUX Off Input Leakage Channel Off, VS = 2.5V ● ±20 nA ID(OFF) MUX Off Output Leakage Channel Off, VD = 2.5V ● ±20 nA tOPEN MUX Break-Before-Make Interval tON Enable Turn-On Time tOFF Enable Turn-Off Time CS(OFF) Input Off Capacitance (MUX) CD(OFF) Output Off Capacitance (MUX) MUX OFF Isolation Channel-to-Channel 290 ns VS = 1.5V, RL = 3.4k, CL = 15pF 490 ns VS = 1.5V, RL = 3.4k, CL = 15pF 190 ns 10 pF DC at 1Hz at fS = 15,360Hz 10 pF 120 120 120 dB dB dB 3 LTC2424/LTC2428 U U DIGITAL I PUTS A D DIGITAL OUTPUTS The ● denotes specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25°C. (Note 3) SYMBOL PARAMETER CONDITIONS VIH High Level Input Voltage CS, FO 2.7V ≤ VCC ≤ 5.5V 2.7V ≤ VCC ≤ 3.3V ● VIL Low Level Input Voltage CS, FO 4.5V ≤ VCC ≤ 5.5V 2.7V ≤ VCC ≤ 5.5V ● VIH High Level Input Voltage SCK 2.7V ≤ VCC ≤ 5.5V (Note 9) 2.7V ≤ VCC ≤ 3.3V (Note 9) ● VIL Low Level Input Voltage SCK 4.5V ≤ VCC ≤ 5.5V (Note 9) 2.7V ≤ VCC ≤ 5.5V (Note 9) ● IIN Digital Input Current CS, FO 0V ≤ VIN ≤ VCC ● IIN Digital Input Current SCK 0V ≤ VIN ≤ VCC (Note 9) ● CIN Digital Input Capacitance CS, FO CIN Digital Input Capacitance SCK (Note 9) VOH High Level Output Voltage SDO IO = – 800µA ● VOL Low Level Output Voltage SDO IO = 1.6mA ● VOH High Level Output Voltage SCK IO = – 800µA (Note 10) ● VOL Low Level Output Voltage SCK IO = 1.6mA (Note 10) ● IOZ High-Z Output Leakage SDO VIN HMUX MUX High Level Input Voltage MUX Low Level Input Voltage VIN LMUX MIN MAX UNITS 2.5 2.0 V V 0.8 0.6 V V 2.5 2.0 V V 0.8 0.6 V V –10 10 µA –10 10 µA 10 pF 10 pF VCC – 0.5 V 0.4 V VCC – 0.5 ● –10 V + = 3V ● 2 V+ ● = 2.4V TYP V 0.4 V 10 µA V 0.8 V U W POWER REQUIRE E TS The ● denotes specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25°C. (Note 3) SYMBOL PARAMETER VCC Supply Voltage ICC Supply Current (Pin 2) Conversion Mode Sleep Mode ICC(MUX) 4 Multiplexer Supply Current (Pin 8) CONDITIONS MIN ● TYP 2.7 MAX UNITS 5.5 V CS = 0V (Note 12) CS = VCC (Note 12) ● ● 200 20 300 30 µA µA All Logic Inputs Tied Together VIN = 0V or 5V ● 15 40 µA LTC2424/LTC2428 WU TI I G CHARACTERISTICS The ● denotes specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25°C. (Note 3) SYMBOL PARAMETER CONDITIONS fEOSC External Oscillator Frequency Range 20-Bit Effective Resolution 12-Bit Effective Resolution MIN TYP MAX UNITS tHEO tLEO tCONV Conversion Time FO = 0V FO = VCC External Oscillator (Note 11) fISCK Internal SCK Frequency Internal Oscillator (Note 10) External Oscillator (Notes 10, 11) DISCK Internal SCK Duty Cycle (Note 10) fESCK External SCK Frequency Range (Note 9) ● tLESCK External SCK Low Period (Note 9) ● 250 ns tHESCK External SCK High Period (Note 9) ● 250 ns tDOUT_ISCK Internal SCK 24-Bit Data Output Time Internal Oscillator (Notes 10, 12) External Oscillator (Notes 10, 11) ● ● 1.23 tDOUT_ESCK External SCK 24-Bit Data Output Time (Note 9) ● t1 CS ↓ to SDO Low Z ● 0 150 ns t2 CS ↑ to SDO High Z ● 0 150 ns t3 CS ↓ to SCK ↓ (Note 10) ● 0 150 ns t4 CS ↓ to SCK ↑ (Note 9) ● 50 tKQMAX SCK ↓ to SDO Valid tKQMIN SDO Hold After SCK ↓ ● 15 ns t5 SCK Set-Up Before CS ↓ ● 50 ns t6 SCK Hold After CS ↓ ● ● ● 2.56 2.56k 307.2 2.048M kHz Hz External Oscillator High Period ● 0.5 390 µs External Oscillator Low Period ● 0.5 390 µs ● ● ● 130.86 133.53 136.20 157.03 160.23 163.44 20510/fEOSC (in kHz) 19.2 fEOSC/8 45 (Note 5) Note 1: Absolute Maximum Ratings are those values beyond which the life of the device may be impaired. Note 2: All voltage values are with respect to GND. Note 3: VCC = 2.7 to 5.5V unless otherwise specified, source input is 0Ω. CSADC = CSMUX = CS. VREF = FSSET – ZSSET. Note 4: Internal Conversion Clock source with the FO pin tied to GND or to VCC or to external conversion clock source with fEOSC = 153600Hz unless otherwise specified. Note 5: Guaranteed by design, not subject to test. Note 6: Integral nonlinearity is defined as the deviation of a code from a straight line passing through the actual endpoints of the transfer curve. The deviation is measured from the center of the quantization band. Note 7: FO = 0V (internal oscillator) or fEOSC = 153600Hz ±2% (external oscillator). Note 8: FO = VCC (internal oscillator) or fEOSC = 128000Hz ±2% (external oscillator). kHz kHz 55 % 2000 kHz 1.25 1.28 192/fEOSC (in kHz) ms ms 24/fESCK (in kHz) ms ns 200 ● ms ms ms 50 ns ns Note 9: The converter is in external SCK mode of operation such that the SCK pin is used as digital input. The frequency of the clock signal driving SCK during the data output is fESCK and is expressed in kHz. Note 10: The converter is in internal SCK mode of operation such that the SCK pin is used as digital output. In this mode of operation the SCK pin has a total equivalent load capacitance CLOAD = 20pF. Note 11: The external oscillator is connected to the FO pin. The external oscillator frequency, fEOSC, is expressed in kHz. Note 12: The converter uses the internal oscillator. FO = 0V or FO = VCC. Note 13: The output noise includes the contribution of the internal calibration operations. Note 14: VREF = FSSET – ZSSET. The minimum input voltage is limited to – 0.3V and the maximum to VCC + 0.3V. Note 15: VS is the voltage applied to a channel input. VD is the voltage applied to the MUX output. Note 16: VCC(DC) = 4.1V, VCC(AC) = 2.8VP-P. 5 LTC2424/LTC2428 U W TYPICAL PERFOR A CE CHARACTERISTICS Total Unadjusted Error (3V Supply) 10 10 VCC = 3V VREF = 2.5V 8 6 4 4 4 0 –2 –4 ERROR (ppm) 6 2 2 0 –2 TA = –55°C, –45°C, 25°C, 90°C TA = –55°C, –45°C, 25°C, 90°C –6 –8 –10 2.5 0.5 0 1.5 2.0 1.0 INPUT VOLTAGE (V) 6 4 –2 2.60 2.65 2.70 INPUT VOLTAGE (V) 2.75 2.80 –8 –10 1 0 3 2 INPUT VOLTAGE (V) 4 6 4 TA = 25°C TA = 90°C TA = –45°C 8 0 –2 VCC = 5V VREF = 5V 0 –2 –6 –6 –8 –0.05 –0.10 –0.15 –0.20 –0.25 –0.30 INPUT VOLTAGE (V) 24248 G07 4 –10 5.00 5 VCC = 5V TA = 25°C 120 2 –4 –10 3 2 INPUT VOLTAGE (V) Offset Error vs Reference Voltage 4 –4 –8 1 150 6 2 0 2420 G06 Positive Input Extended Total Unadjusted Error (5V Supply) 10 TA = –55°C 0 5 24248 G05 ERROR (ppm) VCC = 5V VREF = 5V TA = –55°C, –45°C, 25°C, 90°C –6 –8 Negative Input Extended Total Unadjusted Error (5V Supply) 8 –2 –10 24248 G04 10 2 0 –4 TA = –55°C, –45°C, 25°C, 90°C TA = –55°C TA = 90°C TA = 25°C OFFSET ERROR (ppm) 2.55 –2 –6 –8 –10 2.50 2 0 –4 TA = –55°C, –45°C, 25°C, 90°C –6 ERROR (ppm) 6 4 –4 VCC = 5V VREF = 5V 8 4 ERROR (ppm) ERROR (ppm) VCC = 5V VREF = 5V 6 0 6 INL (5V Supply) 10 8 2 –0.05 –0.10 –0.15 –0.20 –0.25 –0.30 INPUT VOLTAGE (V) 24248 G03 Total Unadjusted Error (5V Supply) 10 VCC = 3V VREF = 2.5V 8 0 2.5 24248 G02 Positive Input Extended Total Unadjusted Error (3V Supply) 10 TA = –55°C –6 –8 24248 G01 ERROR (ppm) 0 –10 1.5 2.0 1.0 INPUT VOLTAGE (V) TA = –45°C –2 –8 0.5 TA = 25°C 2 –10 0 TA = 90°C –4 –4 –6 VCC = 3V VREF = 2.5V 8 6 ERROR (ppm) ERROR (ppm) 10 VCC = 3V VREF = 2.5V 8 Negative Input Extended Total Unadjusted Error (3V Supply) INL (3V Supply) 90 60 30 TA = –45°C 0 5.05 5.10 5.15 5.20 INPUT VOLTAGE (V) 5.25 5.30 24248 G08 0 1 3 4 2 REFERENCE VOLTAGE (V) 5 24248 G09 LTC2424/LTC2428 U W TYPICAL PERFOR A CE CHARACTERISTICS RMS Noise vs Reference Voltage 60 Offset Error vs VCC 10 VCC = 5V TA = 25°C VREF = 2.5V TA = 25°C 30 20 5 VREF = 2.5V TA = 25°C 7.5 RMS NOISE (ppm) OFFSET ERROR (ppm) RMS NOISE (ppm OF VREF) 50 40 RMS Noise vs VCC 10.0 0 –5 5.0 2.5 10 0 0 1 –10 5 2 3 4 REFERENCE VOLTAGE (V) 0 2.7 3.2 3.7 4.2 VCC (V) 5.2 5.5 4.7 24248 G10 Noise Histogram 3.75 RMS NOISE (ppm) 150 100 4.2 VCC (V) 4.7 5.2 5.5 Offset Error vs Temperature 10 VCC = 5V VREF = 5V VIN = 0.3V TO 5.3V TA = 25°C OFFSET ERROR (ppm) 5.00 VCC = 5 =5 V 300 VREF= 0 IN 200 3.7 24248 G12 RMS Noise vs Code Out 250 3.2 24248 G11 350 NUMBER OF READINGS 2.7 2.50 1.25 VCC = 5V VREF = 5V VIN = 0V 5 0 –5 50 –2 4 2 0 OUTPUT CODE (ppm) 6 0 7FFFFF CODE OUT (HEX) FFFFFF –5 FULL-SCALE ERROR (ppm) FULL-SCALE ERROR (ppm) FULL-SCALE ERROR (ppm) 10 –25 0 120 Full-Scale Error vs VCC 0 5 95 24248 G15 Full-Scale Error vs Reference Voltage Full-Scale Error vs Temperature VCC = 5V VREF = 5V VIN = 5V 70 –5 20 45 TEMPERATURE (°C) 24248 G14 24248G13 10 –10 –55 –30 0 0 –50 –75 –100 VREF = 2.5V VIN = 2.5V TA = 25°C 5 0 –5 –125 –10 –55 –30 VCC = 5V VIN = VREF –150 70 –5 20 45 TEMPERATURE (°C) 95 120 24248 G16 0 1 2 3 4 REFERENCE VOLTAGE (V) 5 24248 G17 –10 2.7 3.2 3.7 4.2 VCC (V) 4.7 5.2 5.5 24248 G18 7 LTC2424/LTC2428 U W TYPICAL PERFOR A CE CHARACTERISTICS Conversion Current vs Temperature Sleep Current vs Temperature 220 VCC = 4.1V VIN = 0V T = 25°C –40 F A = 0 O VCC = 5.5V 200 VCC = 4.1V 190 180 VCC = 2.7V 170 VCC = 2.7V 20 REJECTION (dB) SUPPLY CURRENT (µA) 210 SUPPLY CURRENT (µA) Rejection vs Frequency at VCC –20 30 230 VCC = 5V 10 –60 –80 –100 160 150 – 55 –30 70 45 20 TEMPERATURE (°C) –5 95 –120 0 –55 –30 120 –5 20 45 70 TEMPERATURE (°C) 95 Rejection vs Frequency at VCC –40 –40 –40 REJECTION (dB) –20 REJECTION (dB) REJECTION (dB) VCC = 4.1V VIN = 0V –20 TA = 25°C FO = 0 –60 –80 –100 –100 –120 15200 15250 15300 15350 15400 15450 15500 FREQUENCY AT VCC (Hz) –120 –80 1 1M –20 REJECTION (dB) –80 Rejection vs Frequency at VIN 0 VCC = 5V VREF = 5V VIN = 2.5V FO = 0 –40 –40 –60 –80 –60 –80 –100 –120 –100 –130 fS = 15,360Hz –20 REJECTION (dB) –70 250 100 150 200 FREQUENCY AT VIN (Hz) 24248 G23 Rejection vs Frequency at VIN 0 –110 50 24248 G22 Rejection vs Frequency at VIN –120 SAMPLE RATE = 15.36kHz ± 2% –140 –120 15100 –12 –8 –4 0 4 8 12 INPUT FREQUENCY DEVIATION FROM NOTCH FREQUENCY (%) 24248 G24 8 –60 –120 100 10k FREQUENCY AT VCC (Hz) 24248 G21 –100 VCC = 5V VREF = 5V VIN = 2.5V FO = 0 –100 1 –60 250 Rejection vs Frequency at VIN VCC = 4.1V VIN = 0V –20 TA = 25°C FO = 0 –90 150 200 100 FREQUENCY AT VCC (Hz) 0 0 –80 50 24248 G20 Rejection vs Frequency at VCC 0 –60 0 24248 G19 24248 G30 REJECTION (dB) 120 15200 15300 15400 FREQUENCY AT VIN (Hz) 15500 –140 0 fS/2 fS INPUT FREQUENCY 24248 G25 24248 F29 LTC2424/LTC2428 U W TYPICAL PERFOR A CE CHARACTERISTICS VCC = 5V VREF = 5V FO = EXTERNAL 16 TA = –45°C TA = 25°C 14 TA = 90°C VCC = 5V VREF = 5V fO = EXTERNAL TA = 25°C TA = 90°C TA = –45°C 22 16 TA = –45°C 14 TA = 25°C TA = 90°C 20 18 12 12 10 24 VCC = 3V VREF = 2.5V FO = EXTERNAL 18 TUE RESOLUTION (BITS) TUE RESOLUTION (BITS) 18 Resolution vs Output Rate INL vs Output Rate 20 RESOLUTION (BITS) INL vs Output Rate 20 10 0 10 20 30 40 50 60 70 80 90 100 OUTPUT RATE (Hz) 16 0 10 20 30 40 50 60 70 80 90 100 OUTPUT RATE (Hz) 24248 G27 0 7.5 25 75 50 OUTPUT RATE (Hz) 24248 G28 100 24248 G29 U U U PIN FUNCTIONS GND (Pins 1, 6, 16, 18, 22, 27, 28): Ground. Should be connected directly to a ground plane through a minimum length trace or it should be the single-point-ground in a single-point grounding system. CH1 (Pin 10): Analog Multiplexer Input. VCC (Pins 2, 8): Positive Supply Voltage. 2.7V ≤ VCC ≤ 5.5V. Bypass to GND with a 10µF tantalum capacitor in parallel with 0.1µF ceramic capacitor as close to the part as possible. CH4 (Pin 13): Analog Multiplexer Input. No connect on the LTC2424. FSSET (Pin 3): Full-Scale Set Input. This pin defines the full-scale input value. When VIN = FSSET, the ADC outputs full scale (FFFFFH). The total reference voltage (VREF) is FSSET – ZSSET. CH6 (Pin 15): Analog Multiplexer Input. No connect on the LTC2424. ADCIN (Pin 4): Analog Input. The input voltage range is – 0.125 • VREF to 1.125 • VREF. For VREF > 2.5V the input voltage range may be limited by the pin absolute maximum rating of – 0.3V to VCC + 0.3V. ZSSET (Pin 5): Zero-Scale Set Input. This pin defines the zero-scale input value. When VIN = ZSSET, the ADC outputs zero scale (00000H). For pin compatibility with the LTC2404/ LTC2408 this pin must be grounded. MUXOUT (Pin 7): MUX Output. This pin is the output of the multiplexer. Tie to ADCIN for normal operation. CH0 (Pin 9): Analog Multiplexer Input. CH2 (Pin 11): Analog Multiplexer Input. CH3 (Pin 12): Analog Multiplexer Input. CH5 (Pin 14): Analog Multiplexer Input. No connect on the LTC2424. CH7 (Pin 17): Analog Multiplexer Input. No connect on the LTC2424. CLK (Pin 19): Shift Clock for Data In. This clock synchronizes the serial data transfer into the MUX. For normal operation, drive this pin in parallel with SCK. CSMUX (Pin 20): MUX Chip Select Input. A logic high on this input allows the MUX to receive a channel address. A logic low enables the selected MUX channel and connects it to the MUXOUT pin for A/D conversion. For normal operation, drive this pin in parallel with CSADC. DIN (Pin 21): Digital Data Input. The multiplexer address is shifted into this input on the last four rising CLK edges before CSMUX goes low. 9 LTC2424/LTC2428 U U U PIN FUNCTIONS CSADC (Pin 23): ADC Chip Select Input. A low on this pin enables the SDO digital output and following each conversion, the ADC automatically enters the Sleep mode and remains in a low power state as long as CSADC is high. If CSADC is low during the sleep state, the device draws normal power. A high on this pin also disables the SDO digital output. A low-to-high transition on CSADC during the Data Output state aborts the data transfer and starts a new conversion. For normal operation, drive this pin in parallel with CSMUX. SDO (Pin 24): Three-State Digital Output. During the data output period this pin is used for serial data output. When the chip select CSADC is high (CSADC = VCC), the SDO pin is in a high impedance state. During the Conversion and Sleep periods, this pin can be used as a conversion status output. The conversion status can be observed by pulling CSADC low. SCK (Pin 25): Shift Clock for Data Out. This clock synchronizes the serial data transfer of the ADC data output. Data is shifted out of SDO on the falling edge of SCK. For normal operation, drive this pin in parallel with CLK. FO (Pin 26): Digital input which controls the ADC’s notch frequencies and conversion time. When the FO pin is connected to VCC (FO = VCC), the converter uses its internal oscillator and the digital filter first null is located at 50Hz. When the FO pin is connected to GND (FO = OV), the converter uses its internal oscillator and the digital filter first null is located at 60Hz. When FO is driven by an external clock signal with a frequency fEOSC, the converter uses this signal as its clock and the digital filter first null is located at a frequency fEOSC/2560. The resulting output word rate is fEOSC /20510. W FU CTIO AL BLOCK DIAGRA U U INTERNAL OSCILLATOR VCC GND AUTOCALIBRATION AND CONTROL 8-CHANNEL MUX CH0 CH1 CH2 CH3 CH4 CH5 CH6 CH7 ∫ ∫ FO (INT/EXT) ∫ ∑ SDO SERIAL INTERFACE ADC ZSSET SCK CSADC FSSET DECIMATING FIR CSMUX CHANNEL SELECT DAC DIN CLK 24248 BD TEST CIRCUITS VCC 3.4k SDO SDO 3.4k Hi-Z TO VOH VOL TO VOH VOH TO Hi-Z 10 CLOAD = 20pF 24248 TC01 CLOAD = 20pF Hi-Z TO VOL VOH TO VOL VOL TO Hi-Z 24248 TC02 LTC2424/LTC2428 U U W U APPLICATIONS INFORMATION Converter Operation Cycle The LTC2424/LTC2428 are low power, 4-/8-channel deltasigma analog-to-digital converters with easy-to-use 4-wire interfaces. Their operation is simple and made up of four states. The converter operation begins with the conversion, followed by a sleep state and concluded with the data output (see Figure 1). Channel selection may be performed while the device is in the sleep state or at the conclusion of the data output state. The interface consists of serial data output (SDO), serial clock (CLK/SCK), chip select (CSADC/CSMUX) and data input (DIN). By tying SCK to CLK and CSADC to CSMUX, the interface requires only four wires. Initially, the LTC2424 or LTC2428 performs a conversion. Once the conversion is complete, the device enters the sleep state. While in the sleep state if CSADC is high, power consumption is reduced by an order of magnitude. The part remains in the sleep state as long as CSADC is logic HIGH. The conversion result is held indefinitely in a static shift register while the converter is in the sleep state. Channel selection for the next conversion cycle is performed while the device is in the sleep state or at the end of the data output state. A specific channel is selected by applying a 4-bit serial word to the DIN pin on the rising edge of CLK while CSMUX is HIGH, see Figure 4 and Table 3. The CONVERT CHANNEL SELECT (SLEEP) SLEEP 1 CSADC AND SCK 0 DATA OUTPUT (CHANNEL SELECT) 24248 F01 Figure 1. LTC2428 State Transition Diagram channel is selected based on the last four bits clocked into the DIN pin before CSMUX goes low. If DIN is all 0’s, the previous channel remains selected. In the example, Figure 4, the MUX channel is selected during the sleep state, just before the data output state begins. Once the channel selection is complete, the device remains in the sleep state as long as CSADC remains HIGH. Once CSADC is pulled low, the device begins outputting the conversion result. There is no latency in the conversion result. Since there is no latency, the first conversion following a change in input channel is valid and corresponds to that channel. The data output corresponds to the conversion just performed. This result is shifted out on the serial data output pin (SDO) under the control of the serial clock (SCK). Data is updated on the falling edge of SCK allowing the user to reliably latch data on the rising edge of SCK, see Figure 4. The data output state is concluded once 24 bits are read out of the ADC or when CSADC is brought HIGH. The device automatically initiates a new conversion and the cycle repeats. Through timing control of the CSADC and SCK pins, the LTC2424/LTC2428 offer two modes of operation: internal or external SCK. These modes do not require programming configuration registers; moreover, they do not disturb the cyclic operation described above. These modes of operation are described in detail in the Serial Interface Timing Modes section. Conversion Clock A major advantage delta-sigma converters offer over conventional type converters is an on-chip digital filter (commonly known as Sinc or Comb filter). For high resolution, low frequency applications, this filter is typically designed to reject line frequencies of 50 or 60Hz plus their harmonics. In order to reject these frequencies in excess of 110dB, a highly accurate conversion clock is required. The LTC2424/LTC2428 incorporate an on-chip highly accurate oscillator. This eliminates the need for external frequency setting components such as crystals or oscillators. Clocked by the on-chip oscillator, the LTC2424/ LTC2428 reject line frequencies (50 or 60Hz ±2%) a minimum of 110dB. 11 LTC2424/LTC2428 U W U U APPLICATIONS INFORMATION Ease of Use The LTC2424/LTC2428 data output has no latency, filter settling or redundant data associated with the conversion cycle. There is a one-to-one correspondence between the conversion and the output data. Therefore, multiplexing an analog input voltage is easy. The LTC2424/LTC2428 perform offset and full-scale calibrations every conversion cycle. This calibration is transparent to the user and has no effect on the cyclic operation described above. The advantage of continuous calibration is extreme stability of offset and full-scale readings with respect to time, supply voltage change and temperature drift. Power-Up Sequence The LTC2424/LTC2428 automatically enter an internal reset state when the power supply voltage VCC drops below approximately 2.2V. When the VCC voltage rises above this critical threshold, the converter creates an internal power-on-reset (POR) signal with duration of approximately 0.5ms. The POR signal clears all internal registers within the ADC and initiates a conversion. At power-up, the multiplexer channel is disabled and should be programmed once the device enters the sleep state. The results of the first conversion following a POR are not valid since a multiplexer channel was disabled. Reference Voltage Range The LTC2424/LTC2428 can accept a reference voltage (VREF = FSSET – ZSSET) from 0V to VCC. The converter output noise is determined by the thermal noise of the front-end circuits, and as such, its value in microvolts is nearly constant with reference voltage. A decrease in reference voltage will not significantly improve the converter’s effective resolution. On the other hand, a reduced reference voltage will improve the overall converter INL performance. The recommended range for the LTC2424/LTC2428 voltage reference is 100mV to VCC. Input Voltage Range The converter is able to accommodate system level offset and gain errors as well as system level overrange situations due to its extended input range, see Figure 2. 12 VCC + 0.3V FSSET + 0.12VREF FSSET NORMAL INPUT RANGE EXTENDED INPUT RANGE ABSOLUTE MAXIMUM INPUT RANGE ZSSET ZSSET – 0.12VREF –0.3V VREF = FSSET – ZSSET 24248 F02 Figure 2. LTC2424/LTC2428 Input Range The LTC2424/LTC2428 converts input signals within the extended input range of – 0.125 • VREF to 1.125 • VREF (VREF = FSSET – ZSSET). For large values of VREF this range is limited to a voltage range of – 0.3V to (VCC + 0.3V). Beyond this range the input ESD protection devices begin to turn on and the errors due to the input leakage current increase rapidly. Input signals applied to VIN may extend below ground by – 300mV and above VCC by 300mV. In order to limit any fault current, a resistor of up to 5k may be added in series with any channel input pin (CH0 to CH7) without affecting the performance of the device. In the physical layout, it is important to maintain the parasitic capacitance of the connection between this series resistance and the channel input pin as low as possible; therefore, the resistor should be located as close as practical to the channel input pin. The effect of the series resistance on the converter accuracy can be evaluated from the curves presented in the Analog Input/Reference Current section. In addition, a series resistor will introduce a temperature dependent offset error due to the input leakage current. A 1nA input leakage current will develop a 1ppm offset error on a 5k resistor if VREF = 5V. This error has a very strong temperature dependency. Output Data Format The LTC2424/LTC2428 serial output data stream is 24 bits long. The first 4 bits represent status information indicating the sign, input range and conversion state. The next 20 bits are the conversion result, MSB first. LTC2424/LTC2428 U W U U APPLICATIONS INFORMATION The LTC2424/LTC2428 can be interchanged with the LTC2404/LTC2408. The two devices are designed to allow the user to incorporate either device in the same design as long as ZSSET (Pin 5) of the LTC2424/LTC2428 is tied to ground. While the LTC2424/LTC2428 output word lengths are 24 bits (as opposed to the 32-bit output of the LTC2404/ LTC2408), their output clock timing can be identical to the LTC2404/LTC2408. As shown in Figure 3, the LTC2424/ LTC2428 data output is concluded on the falling edge of the 24th serial clock (SCK). In order to maintain drop-in compatibility with the LTC2404/LTC2408, it is possible to clock the LTC2424/LTC2428 with an additional 8 serial clock pulses. This results in 8 additional output bits which are logic HIGH. Bit 23 (first output bit) is the end of conversion (EOC) indicator. This bit is available at the SDO pin during the conversion and sleep states whenever the CS pin is LOW. This bit is HIGH during the conversion and goes LOW when the conversion is complete. Bit 22 (second output bit) is a dummy bit (DMY) and is always LOW. Bit 21 (third output bit) is the conversion result sign indicator (SIG). If VIN is >0, this bit is HIGH. If VIN is <0, this bit is LOW. The sign bit changes state during the zero code. Bit 20 (forth output bit) is the extended input range (EXR) indicator. If the input is within the normal input range 0␣ ≤␣ VIN ≤ VREF, this bit is LOW. If the input is outside the normal input range, VIN > VREF or VIN < 0, this bit is HIGH. The function of these bits is summarized in Table 1. Table 1. LTC2424/LTC2428 Status Bits Bit 23 EOC Bit 22 DMY Bit 21 SIG Bit 20 EXR VIN > VREF 0 0 1 1 0 < VIN ≤ VREF 0 0 1 0 0 0 1/0 0 0 0 0 1 Input Range VIN = 0+/0 – VIN < 0 Bit 19 (fifth output bit) is the most significant bit (MSB). Bits 19-0 are the 20-bit conversion result MSB first. Bit 0 is the least significant bit (LSB). Data is shifted out of the SDO pin under control of the serial clock (SCK), see Figure 4. Whenever CSADC is HIGH, SDO remains high impedance and any SCK clock pulses are ignored by the internal data out shift register. In order to shift the conversion result out of the device, CSADC must first be driven LOW. EOC is seen at the SDO pin of the device once CSADC is pulled LOW. EOC changes real time from HIGH to LOW at the completion of a conversion. This signal may be used as an interrupt for an external microcontroller. Bit 23 (EOC) can be captured on the first rising edge of SCK. Bit 22 is shifted out of the device on the first falling edge of SCK. The final data bit (Bit 0) is shifted out on the falling edge of the 23rd SCK and may be latched on the rising edge of the 24th SCK pulse. On the falling edge of the 24th SCK pulse, SDO goes HIGH indicating a new conversion cycle has been initiated. This bit serves as EOC (Bit 23) for the next conversion cycle. Table 2 summarizes the output data format. CSADC 8 8 8 8 (OPTIONAL) SCK SDO EOC = 1 EOC = 0 DATA OUT 4 STATUS BITS 20 DATA BITS CONVERSION SLEEP DATA OUTPUT EOC = 1 LAST 8 BITS LOGIC CONVERSION 24248 F03 Figure 3. LTC2424/LTC2428 Compatible Timing with the LTC2404/LTC2408 13 LTC2424/LTC2428 U U W U APPLICATIONS INFORMATION tCONV CSMUX/CSADC SDO Hi-Z EOC “0” SIG EXT MSB Hi-Z LSB BIT 23 BIT 22 BIT 0 SCK/CLK DIN EN D2 D1 DON’T CARE D0 24248 F04 Figure 4. Typical Data Input/Output Timing Table 2. LTC2424/LTC2428 Output Data Format Bit 23 EOC Bit 22 DMY Bit 21 SIG Bit 20 EXR Bit 19 MSB Bit 18 Bit 17 Bit 16 Bit 15 … Bit 0 LSB VIN > 9/8 • VREF 0 0 1 1 0 0 0 1 1 ... 1 9/8 • VREF 0 0 1 1 0 0 0 1 1 ... 1 VREF + 1LSB 0 0 1 1 0 0 0 0 0 ... 0 VREF 0 0 1 0 1 1 1 1 1 ... 1 Input Voltage 3/4VREF + 1LSB 0 0 1 0 1 1 0 0 0 ... 0 3/4VREF 0 0 1 0 1 0 1 1 1 ... 1 1/2VREF + 1LSB 0 0 1 0 1 0 0 0 0 ... 0 1/2VREF 0 0 1 0 0 1 1 1 1 ... 1 1/4VREF + 1LSB 0 0 1 0 0 1 0 0 0 ... 0 1/4VREF 0 0 1 0 0 0 1 1 1 ... 1 0+/0 – 0 0 1/0* 0 0 0 0 0 0 ... 0 –1LSB 0 0 0 1 1 1 1 1 1 ... 1 –1/8 • VREF 0 0 0 1 1 1 1 0 0 ... 0 VIN < –1/8 • VREF 0 0 0 1 1 1 1 0 0 ... 0 *The sign bit changes state during the 0 code. As long as the voltage on the VIN pin is maintained within the – 0.3V to (VCC + 0.3V) absolute maximum operating range, a conversion result is generated for any input value from – 0.125 • VREF to 1.125 • VREF. For input voltages greater than 1.125 • VREF, the conversion result is clamped to the value corresponding to 1.125 • VREF. For input voltages below – 0.125 • VREF, the conversion result is clamped to the value corresponding to – 0.125 • VREF. 14 Channel Selection Typically, CSADC and CSMUX are tied together or CSADC is inverted and drives CSMUX. SCK and CLK are tied together and driven with a common clock signal. During channel selection, CSMUX is HIGH. Data is shifted into the DIN pin on the rising edge of CLK, see Figure 4. Table 3 shows the bit combinations for channel selection. In order to enable the multiplexer output, CSMUX must be pulled LTC2424/LTC2428 U U W U APPLICATIONS INFORMATION While the multiplexer is being programmed, the ADC is in the sleep state. Once the MUX addressing is complete, the data from the preceding conversion can be read. A new conversion cycle is initiated following the data read cycle with the analog input tied to the newly selected channel. Table 3. Logic Table for Channel Selection CHANNEL STATUS EN D2 D1 D0 All Off 0 X X X CH0 1 0 0 0 CH1 1 0 0 1 CH2 1 0 1 0 CH3 1 0 1 1 CH4* 1 1 0 0 CH5* 1 1 0 1 CH6* 1 1 1 0 CH7* 1 1 1 1 *Not used for the LTC2424. Frequency Rejection Selection (FO Pin Connection) The LTC2424/LTC2428 internal oscillator provides better than 110dB normal mode rejection at the line frequency and all its harmonics for 50Hz ±2% or 60Hz ±2%. For 60Hz rejection, FO (Pin 26) should be connected to GND (Pin 1) while for 50Hz rejection the FO pin should be connected to VCC (Pin␣ 2). The selection of 50Hz or 60Hz rejection can also be made by driving FO to an appropriate logic level. A selection change during the sleep or data output states will not disturb the converter operation. If the selection is made during the conversion state, the result of the conversion in progress may be outside specifications but the following conversions will not be affected. When a fundamental rejection frequency different from 50Hz or 60Hz is required or when the converter must be synchronized with an outside source, the LTC2424/ LTC2428 can operate with an external conversion clock. The converter automatically detects the presence of an external clock signal at the FO pin and turns off the internal oscillator. The frequency fEOSC of the external signal must be at least 2560Hz (1Hz notch frequency) to be detected. The external clock signal duty cycle is not significant as long as the minimum and maximum specifications for the high and low periods tHEO and tLEO are observed. While operating with an external conversion clock of a frequency fEOSC, the LTC2424/LTC2428 provide better than 110dB normal mode rejection in a frequency range fEOSC/2560 ±4% and its harmonics. The normal mode rejection as a function of the input frequency deviation from fEOSC/2560 is shown in Figure 5. –60 –70 –80 REJECTION (dB) LOW. The multiplexer should be programmed after the previous conversion is complete. In order to guarantee the conversion is complete, the multiplexer addressing should be delayed a minimum tCONV (approximately 133ms for a 60Hz notch) after the data out is read. –90 –100 –110 –120 –130 –140 –12 –8 –4 0 4 8 12 INPUT FREQUENCY DEVIATION FROM NOTCH FREQUENCY (%) 24248 F05 Figure 5. LTC2424/LTC2428 Normal Mode Rejection When Using an External Oscillator of Frequency fEOSC Whenever an external clock is not present at the F O pin the converter automatically activates its internal oscillator and enters the Internal Conversion Clock mode. The LTC2424/ LTC2428 operation will not be disturbed if the change of conversion clock source occurs during the sleep state or during the data output state while the converter uses an external serial clock. If the change occurs during the conversion state, the result of the conversion in progress may be outside specifications but the following conversions will not be affected. If the change occurs during the data output state and the converter is in the Internal SCK mode, the serial clock duty cycle may be affected but the serial data stream will remain valid. 15 LTC2424/LTC2428 U U W U APPLICATIONS INFORMATION Table 4 summarizes the duration of each state as a function of FO. Operation at Higher Data Output Rates The LTC2424/LTC2428 typically operate with an internal oscillator of 153.6kHz. This corresponds to a notch frequency of 60Hz and an output rate of 7.5 samples/second. The internal oscillator is enabled if the FO pin is logic LOW (logic HIGH for a 50Hz notch). It is possible to drive the FO pin with an external oscillator for higher data output rates. As shown in Figure 6, an external clock of 2.051MHz applied to the FO pin results in a notch frequency of 800Hz with a data output rate of 100 samples/second. Figure 7 shows the total unadjusted error (Offset Error + Full-Scale Error + INL + DNL) as a function of the output data rate with a 5V reference. The relationship between the output data rate (ODR) and the frequency applied to the FO pin (FO) is: ODR = FO/20510 Table 4. LTC2424/LTC2428 State Duration State Operating Mode CONVERT Internal Oscillator Duration External Oscillator FO = LOW (60Hz Rejection) 133ms FO = HIGH (50Hz Rejection) 160ms FO = External Oscillator with Frequency fEOSC kHz (fEOSC/2560 Rejection) 20510/fEOSC (In Seconds) SLEEP As Long As CSADC = HIGH Until CSADC = 0 and SCK DATA OUTPUT Internal Serial Clock FO = LOW/HIGH (Internal Oscillator) As Long As CSADC = LOW But Not Longer Than 1.67ms (32 SCK cycles) FO = External Oscillator with Frequency fEOSC kHz As Long As CSADC = LOW But Not Longer Than 256/fEOSCms (32 SCK cycles) External Serial Clock with Frequency fSCK kHz As Long As CSADC = LOW But Not Longer Than 32/fSCKms (32 SCK cycles) 1 OWR = in Hz tCONVERT + tDATAOUTPUT MAXIMUM OUTPUT WORD RATE (OWR) LTC2424 2 3 4 5 6 7 8 9 10 11 12 13 14 GND GND VCC GND FSSET FO ADCIN SCK ZSSET SDO GND CSADC MUXOUT GND VCC DIN CH0 CSMUX CH1 CLK CH2 GND CH3 NC NC GND NC NC 28 R9 1k 27 10k R8 1k 26 25 C8 5pF 24 23 C9 0.1µF 5V 22 21 HCO4 5 12 13 20 19 + C6 3 2 4 10 1 7 C7 10pF 18 17 270pF HCO4 6 11 16 15 8 9 256 R7 5k R6 47k 10 TURN POT SWITCH TOTAL UNADJUSTED ERROR (ppm) 1 12 BITS 192 160 13 BITS 128 96 14 BITS 64 32 0 24248 F06 VREF = 5V 224 16 BITS 0 50 100 150 OUTPUT RATE (SAMPLES/SEC) 24248 F07 Figure 6. Selectable 100 Sample/Second Turbo Mode 16 Figure 7. Total Error vs Output Rate (VREF = 5V) LTC2424/LTC2428 U W U U APPLICATIONS INFORMATION At 100 samples/second, the LTC2424/LTC2428 can be used to capture transient data. This is useful for monitoring settling or auto gain ranging in a system. The LTC2424/ LTC2428 can monitor signals at an output rate of 100 samples/second. After acquiring 100 samples/second data, the FO pin may be driven LOW enabling 60Hz rejection to 110dB and the highest possible DC accuracy. The no latency architecture of the LTC2424/LTC2428 allows consecutive readings (one at 100 samples/second the next at 7.5 samples/second) without interaction between the two readings. As shown in Figure 11, the LTC2424/LTC2428 can capture transient data with 90dB of dynamic range (with a 300mVP-P input signal at 2Hz). The exceptional DC performance of the LTC2424/LTC2428 enables signals to be digitized independent of a large DC offset. Figures 12a and 12b show the dynamic performance with a 15Hz signal superimposed on a 2V DC level. The same signal with no DC level is shown in Figures 12c and 12d. 256 TOTAL UNADJUSTED ERROR (ppm) OUTPUT RATE = 100sps ADC Serial Clock Input/Output (SCK) The serial clock signal present on SCK (Pin 25) is used to synchronize the data transfer. Each bit of data is shifted out of the SDO pin on the falling edge of the serial clock. 192 160 13 BITS 128 96 14 BITS 64 15 BITS 32 1.5 2.0 2.5 3.0 3.5 4.0 REFERENCE VOLTAGE (V) 4.5 5.0 24248 F08 Figure 8. Total Error vs VREF (Output Rate = 100sps) 10 VCC = 5V VREF = 2.5V 5 0 –5 –10 –15 –20 –25 –30 –35 –40 0 2.5 INPUT VOLTAGE (V) 24248 F09 Figure 9. Total Unadjusted Error at 100 Samples/Second (No Averaging) SERIAL INTERFACE 6 TOTAL UNADJUSTED ERROR (ppm) The LTC2424/LTC2428 transmit the conversion results, program the channel selection, and receive the start of conversion command through a synchronous 4-wire interface (SCK = CLK, CSADC = CSMUX). During the conversion and sleep states, this interface can be used to assess the converter status. While in the sleep state this interface may be used to program an input channel. During the data output state, it is used to read the conversion result. 12 BITS 224 0 1.0 TOTAL UNADJUSTED ERROR (ppm) For output data rates up to 50 samples/second, the total unadjusted error (TUE) is better than 16 bits, and better than 12 bits at 100 samples/second. As shown in Figure 8, for output data rates of 100 samples/second, the TUE is better than 15 bits for VREF below 2.5V. Figure 9 shows an unaveraged total unadjusted error for the LTC2424 or LTC2428 operating at 100 samples/second with VREF = 2.5V. Figure 10 shows the same device operating with a 5V reference and an output data rate of 7.5 samples/second. VCC = 5V VREF = 5V 4 2 0 –2 –4 –6 –8 –10 5 0 INPUT VOLTAGE (V) 24248 F10 Figure 10. Total Unadjusted Error at 7.5 Samples/Second (No Averaging) 17 LTC2424/LTC2428 U W U U APPLICATIONS INFORMATION 0 2Hz 100sps 0V OFFSET fIN = 2Hz 500ms 0.15 –20 0.10 MAGNITUDE (dB) ADC OUTPUT (NORMALIZED TO VOLTS) 0.20 0.05 0 –0.05 –40 –60 –80 –0.10 –100 –0.15 –120 –0.20 0 0.5 1 1.5 TIME (SEC) 2 2.5 0 24248 F11a Figure 11a. Digitized Waveform 25 FREQUENCY (Hz) 50 24248 F11b Figure 11b. Output FFT Figure 11. Transient Signal Acquisition 0 VIN = 300mVP-P + 2V DC 2.15 –20 2.05 2.00 1.95 –40 –60 –80 1.90 –100 1.85 1.80 –120 0 0.5 1 1.5 2 TIME (SEC) 0.20 0 2.5 24248 F12a Figure 12a. Digitized Waveform with 2V DC Offset 25 FREQUENCY (Hz) 0 VIN = 300mVP-P + 0V DC 0.15 15Hz 100sps 0V OFFSET –20 0.10 0.05 0.00 –0.05 –40 –60 –80 –0.10 –100 –0.15 –120 –0.20 0 0.5 1 1.5 2 TIME (SEC) 2.5 24248 F12c Figure 12c. Digitized Waveform with No Offset 0 25 FREQUENCY (Hz) 50 24248 F12d Figure 12d. FFT Waveform with No Offset Figure 12. Using the LTC2424/LTC2428’s High Accuracy Wide Dynamic Range to Digitize a 300mVP-P 15Hz Waveform with a Large DC Offset (VCC = 5V, VREF = 5V) 18 50 24248 F12b Figure 12b. FFT Waveform with 2V DC Offset MAGNITUDE (dB) ADC OUTPUT (NORMALIZED TO VOLTS) 15Hz 100sps 2V OFFSET 2.10 MAGNITUDE (dB) ADC OUTPUT (NORMALIZED TO VOLTS) 2.20 LTC2424/LTC2428 U W U U APPLICATIONS INFORMATION In the Internal SCK mode of operation, the SCK pin is an output and the LTC2424/LTC2428 creates its own serial clock by dividing the internal conversion clock by 8. In the External SCK mode of operation, the SCK pin is used as input. The internal or external SCK mode is selected on power-up and then reselected every time a HIGH-to-LOW transition is detected at the CSADC pin. If SCK is HIGH or floating at power-up or during this transition, the converter enters the internal SCK mode. If SCK is LOW at power-up or during this transition, the converter enters the external SCK mode. Multiplexer Serial Input Clock (CLK) Generally, this pin is externally tied to SCK for 4-wire operation. On the rising edge of CLK (Pin 19) with CSMUX held HIGH, data is serially shifted into the multiplexer. If CSMUX is LOW the CLK input will be disabled and the channel selection unchanged. Serial Data Output (SDO) The serial data output pin, SDO (Pin 24), drives the serial data during the data output state. In addition, the SDO pin is used as an end of conversion indicator during the conversion and sleep states. When CSADC (Pin 23) is HIGH, the SDO driver is switched to a high impedance state. This allows sharing the serial interface with other devices. If CSADC is LOW during the convert or sleep state, SDO will output EOC. If CSADC is LOW during the conversion phase, the EOC bit appears HIGH on the SDO pin. Once the conversion is complete, EOC goes LOW. The device remains in the sleep state until the first rising edge of SCK occurs while CSADC = 0. ADC Chip Select Input (CSADC) The active LOW chip select, CSADC (Pin 23), is used to test the conversion status and to enable the data output transfer as described in the previous sections. In addition, the CSADC signal can be used to trigger a new conversion cycle before the entire serial data transfer has been completed. The LTC2424/LTC2428 will abort any serial data transfer in progress and start a new conversion cycle anytime a LOW-to-HIGH transition is detected at the CSADC pin after the converter has entered the data output state (i.e., after the first rising edge of SCK occurs with CSADC = 0). Multiplexer Chip Select (CSMUX) For 4-wire operation, this pin is tied directly to CSADC or the output of an inverter tied to CSADC. CSMUX (Pin 20) is driven HIGH during selection of a multiplexer channel. On the falling edge of CSMUX, the selected channel is enabled and drives MUXOUT. Data Input (DIN) The data input to the multiplexer, DIN (Pin 21), is used to program the multiplexer. The input channel is selected by serially shifting a 4-bit input word into the DIN pin under the control of the multiplexer clock, CLK. Data is shifted into the multiplexer on the rising edge of CLK. Table 3 shows the logic table for channel selection. In order to select or change a previously programmed channel, an enable bit (DIN = 1) must proceed the 3-bit channel select serial data. The user may set DIN = 0 to continually convert on the previously selected channel. SERIAL INTERFACE TIMING MODES The LTC2424/LTC2428’s 4-wire interface is SPI and MICROWIRE compatible. This interface offers two modes of operation. These include an internal or external serial clock. The following sections describe both of these serial interface timing modes in detail. For both cases the converter can use the internal oscillator (FO = LOW or FO = HIGH) or an external oscillator connected to the FO pin. Refer to Table 5 for a summary. Table 5. LTC2424/LTC2428 Interface Timing Modes Configuration External SCK Internal SCK SCK Source External Internal Conversion Cycle Control CSADC and SCK CSADC ↓ Data Output Control CSADC and SCK CSADC ↓ Connection and Waveforms Figures 13, 14, 15 Figures 16, 17 19 LTC2424/LTC2428 U U W U APPLICATIONS INFORMATION While the device is in the sleep state, prior to entering the data output state, the user may program the multiplexer. As shown in Figure 13, the multiplexer channel is selected by serial shifting a 4-bit word into the DIN pin on the rising edge of CLK (CLK is tied to SCK). The first bit is an enable bit that must be HIGH in order to program a channel. The next three bits determine which channel is selected, see Table 3. On the falling edge of CSMUX, the new channel is selected and will be valid for the first conversion performed following the data output state. Clock signals applied to the CLK pin while CSMUX is LOW (during the data output state) will have no effect on the channel selection. Furthermore, if DIN is held LOW or CLK is held LOW during the sleep state, the channel selection is unchanged. External Serial Clock (SPI/MICROWIRE Compatible) This timing mode uses an external serial clock (SCK) to shift out the conversion result, see Figure 13. This same external clock signal drives the CLK pin in order to program the multiplexer. A single CS signal drives both the multiplexer CSMUX and converter CSADC inputs. This common signal is used to monitor and control the state of the conversion as well as enable the channel selection. The serial clock mode is selected on the falling edge of CSADC. To select the external serial clock mode, the serial clock pin (SCK) must be LOW during each CSADC falling edge. The serial data output pin (SDO) is Hi-Z as long as CSADC is HIGH. At any time during the conversion cycle, CSADC may be pulled LOW in order to monitor the state of the converter. While CSADC is LOW, EOC is output to the SDO pin. EOC = 1 while a conversion is in progress and EOC = 0 if the device is in the sleep state. Independent of CSADC, the device automatically enters the sleep state once the conversion is complete. While the device is in the sleep state and CSADC is HIGH, the power consumption is reduced an order of magnitude. When the device is in the sleep state (EOC = 0), its conversion result is held in an internal static shift register. The device remains in the sleep state until the first rising edge of SCK is seen while CSADC is LOW. Data is shifted out the SDO pin on each falling edge of SCK. This enables external circuitry to latch the output on the rising edge of SCK. EOC can be latched on the first rising edge of SCK and the last bit of the conversion result can be latched on 2.7V TO 5.5V VCC VCC = 50Hz REJECTION = EXTERNAL OSCILLATOR = 60Hz REJECTION FO LTC2424/LTC2428 0.1V TO VCC –0.12VREF TO 1.12VREF FSSET CSMUX CH0 TO CH7 CSADC MUXOUT SCK CS SCK CLK ADCIN DIN ZSSET SDO GND CSADC/ CSMUX SCK/CLK TEST EOC BIT23 TEST EOC SDO SIG Hi-Z DIN BIT22 BIT21 BIT20 BIT19 BIT18 DON’T CARE BIT4 BIT0 LSB EXR MSB TEST EOC Hi-Z Hi-Z EN D2 D1 D0 DON’T CARE 24248 F13 Figure 13. External Serial Clock Timing Diagram 20 LTC2424/LTC2428 U W U U APPLICATIONS INFORMATION the 24th rising edge of SCK. On the 24th falling edge of SCK, the device begins a new conversion. SDO goes HIGH (EOC = 1) indicating a conversion is in progress. clock input (SCK), or program the multiplexer in the first 1ms following the data output cycle. The remaining 65ms may be used to allow the input signal to settle. At the conclusion of the data cycle, CSADC may remain LOW and EOC monitored as an end-of-conversion interrupt. Alternatively, CSADC may be driven HIGH setting SDO to Hi-Z. As described above, CSADC may be pulled LOW at any time in order to monitor the conversion status. For each of these operations, CSMUX may be tied to CSADC without affecting the selected channel. Typically, CSADC remains LOW during the data output state. However, the data output state may be aborted by pulling CSADC HIGH anytime between the first rising edge and the 24th falling edge of SCK, see Figure 15. On the rising edge of CSADC, the device aborts the data output state and immediately initiates a new conversion. This is useful for systems not requiring all 24 bits of output data, aborting an invalid conversion cycle or synchronizing the start of a conversion. At the conclusion of the data output cycle, the converter enters a user transparent calibration cycle prior to actually performing a conversion on the selected input channel. This allows a 66ms (for 60Hz notch frequency) settling time for the multiplexer input. Following the data output cycle, the multiplexer input channel may be selected any time in this 66ms window by pulling CSADC HIGH and serial shifting data into the DIN pin, see Figure 14. While the device is performing the internal calibration, it is sensitive to ground current disturbances. Error currents flowing in the ground pin may lead to offset errors. If the SCK pin is toggling during the calibration, these ground disturbances will occur. The solution is to either drive the multiplexer clock input (CLK) separately from the ADC Internal Serial Clock This timing mode uses an internal serial clock to shift out the conversion result and program the multiplexer, see Figure 16. A CS signal directly drives the CSADC input, while the inverse of CS drives the CSMUX input. The CS signal is used to monitor and control the state of the conversion cycles as well as enable the channel selection. The multiplexer is programmed during the data output state. The internal serial clock (SCK) generated by the ADC is applied to the multiplexer clock input (CLK). CSADC/ CSMUX SCK/CLK TEST EOC BIT23 BIT22 TEST EOC SDO BIT21 BIT20 BIT19 BIT18 SIG EXR MSB BIT4 BIT0 LSB Hi-Z DIN CONVERTER STATE DON’T CARE CONV SLEEP EN DATA OUTPUT D2 D1 D0 DON’T CARE INTERNAL CALIBRATION 66ms CALIBRATION CONVERSION ON SELECTED CHANNEL 66ms CONVERT 133ms CONVERSION CYCLE (OUTPUT RATE = 7.5Hz) 24248 F14 Figure 14. Use of Look Ahead to Program Multiplexer After Data Output 21 LTC2424/LTC2428 U U W U APPLICATIONS INFORMATION 2.7V TO 5.5V VCC VCC = 50Hz REJECTION = EXTERNAL OSCILLATOR = 60Hz REJECTION FO LTC2424/LTC2428 0.1V TO VCC –0.12VREF TO 1.12VREF FSSET CSMUX CH0 TO CH7 CSADC CS SCK SCK MUXOUT CLK ADCIN DIN ZSSET SDO GND CSADC/ CSMUX SCK/CLK TEST EOC BIT23 TEST EOC BIT22 BIT21 BIT20 BIT19 BIT18 SDO SIG Hi-Z DIN BIT9 BIT8 EXR MSB Hi-Z DON’T CARE EN D2 D1 D0 DON’T CARE 24248 F15 Figure 15. External Serial Clock with Reduced Data Output Length Timing Diagram 2.7V TO 5.5V VCC VCC = 50Hz REJECTION = EXTERNAL OSCILLATOR = 60Hz REJECTION FO LTC2424/LTC2428 0.1V TO VCC –0.12VREF TO 1.12VREF FSSET CSMUX CH0 TO CH7 CSADC SCK MUXOUT CS 10k CLK ADCIN DIN ZSSET SDO GND CSMUX tEOCtest CSADC SCKCLK TEST EOC BIT23 BIT22 BIT21 BIT20 BIT19 BIT18 TEST EOC SDO DON’T CARE BIT0 TEST EOC LSB SIG EXR MSB Hi-Z DIN BIT4 BIT3 BIT2 BIT1 Hi-Z Hi-Z EN D2 D1 D0 DON’T CARE 24248 F16 Figure 16. Internal Serial Clock Timing Diagram 22 LTC2424/LTC2428 U W U U APPLICATIONS INFORMATION In order to select the internal serial clock timing mode, the serial clock pin (SCK) must be floating (Hi-Z) or pulled HIGH prior to the falling edge of CSADC. The device will not enter the internal serial clock mode if SCK is driven LOW on the falling edge of CSADC. An internal weak pull-up resistor is active on the SCK pin during the falling edge of CSADC; therefore, the internal serial clock timing mode is automatically selected if SCK is not externally driven. The serial data output pin (SDO) is Hi-Z as long as CSADC is HIGH. At any time during the conversion cycle, CSADC may be pulled LOW in order to monitor the state of the converter. Once CSADC is pulled LOW, SCK goes LOW and EOC is output to the SDO pin. EOC = 1 while a conversion is in progress and EOC = 0 if the device is in the sleep state. When testing EOC, if the conversion is complete (EOC = 0), the device will exit the sleep state and enter the data output state if CSADC remains LOW. In order to prevent the device from exiting the low power sleep state, CSADC must be pulled HIGH before the first rising edge of SCK. In the internal SCK timing mode, SCK goes HIGH and the device begins outputting data at time tEOCtest after the falling edge of CSADC (if EOC = 0) or tEOCtest after EOC goes LOW (if CSADC is LOW during the falling edge of EOC). The value of tEOCtest is 23µs if the device is using its internal oscillator (F0 = logic LOW or HIGH). If FO is driven by an external oscillator of frequency fEOSC, then tEOCtest is 3.6/fEOSC. If CSADC is pulled HIGH before time tEOCtest, the device remains in the sleep state and the power consumption is reduced an order of magnitude. The conversion result is held in the internal static shift register. If CSADC remains LOW longer than tEOCtest, the first rising edge of SCK will occur and the conversion result is serially shifted out of the SDO pin. The data output cycle begins on this first rising edge of SCK and concludes after the 24th rising edge. Data is shifted out the SDO pin on each falling edge of SCK. The internally generated serial clock is output to the SCK pin. This signal may be used to shift the conversion result into external circuitry. EOC can be latched on the first rising edge of SCK and the last bit of the conversion result on the 24th rising edge of SCK. After the 24th rising edge, SDO goes HIGH (EOC = 1), SCK stays HIGH, and a new conversion starts. While operating in the internal serial clock mode, the SCK output of the ADC may be used as the multiplexer clock (CLK). DIN is latched into the multiplexer on the rising edge of CLK. As shown in Figure 16, the multiplexer channel is selected by serial shifting a 4-bit word into the DIN pin on the rising edge of CLK. The first bit is an enable bit which must be HIGH in order to program a channel. The next three bits determine which channel is selected, see Table 3. On the rising edge of CSADC (falling edge of CSMUX), the new channel is selected and will be valid for the next conversion. If DIN is held LOW during the data output state, the previous channel selection remains valid. Typically, CSADC remains LOW during the data output state. However, the data output state may be aborted by pulling CSADC HIGH anytime between the first and 24th rising edge of SCK, see Figure 17. On the rising edge of CSADC, the device aborts the data output state and immediately initiates a new conversion. This is useful for systems not requiring all 24 bits of output data, aborting an invalid conversion cycle, or synchronizing the start of a conversion. If CSADC is pulled HIGH while the converter is driving SCK LOW, the internal pull-up is not available to restore SCK to a logic HIGH state. This will cause the device to exit the internal serial clock mode on the next falling edge of CSADC. This can be avoided by adding an external 10k pull-up resistor to the SCK pin or by never pulling CSADC HIGH when SCK is LOW. Whenever SCK is LOW, the LTC2424/LTC2428’s internal pull-up at pin SCK is disabled. Normally, SCK is not externally driven if the device is in the internal SCK timing mode. However, certain applications may require an external driver on SCK. If this driver goes Hi-Z after outputting a LOW signal, the LTC2424/LTC2428’s internal pull-up remains disabled. Hence, SCK remains LOW. On the next falling edge of CSADC, the device is switched to the external SCK timing mode. By adding an external 10k pullup resistor to SCK, this pin goes HIGH once the external driver goes Hi-Z. On the next CSADC falling edge, the device will remain in the internal SCK timing mode. 23 LTC2424/LTC2428 U U W U APPLICATIONS INFORMATION 2.7V TO 5.5V VCC = 50Hz REJECTION = EXTERNAL OSCILLATOR = 60Hz REJECTION FO VCC LTC2424/LTC2428 0.1V TO VCC –0.12VREF TO 1.12VREF FSSET CSMUX CH0 TO CH7 CSADC SCK MUXOUT CS 10k CLK ADCIN DIN ZSSET SDO GND CSMUX tEOCtest CSADC SCKCLK TEST EOC BIT23 BIT22 BIT21 BIT20 BIT19 BIT18 TEST EOC SDO Hi-Z DIN BIT12 BIT11 BIT10 BIT9 BIT8 TEST EOC SIG EXR MSB Hi-Z DON’T CARE Hi-Z EN D2 D1 D0 DON’T CARE 24248 F17 Figure 17. Internal Serial Clock with Reduced Data Output Length Timing Diagram A similar situation may occur during the sleep state when CSADC is pulsed HIGH-LOW-HIGH in order to test the conversion status. If the device is in the sleep state (EOC = 0), SCK will go LOW. Once CSADC goes HIGH (within the time period defined above as tEOCtest), the internal pull-up is activated. For a heavy capacitive load on the SCK pin, the internal pull-up may not be adequate to return SCK to a HIGH level before CSADC goes LOW again. This is not a concern under normal conditions where CSADC remains LOW after detecting EOC = 0. This situation is easily avoided by adding an external 10k pullup resistor to the SCK pin. DIGITAL SIGNAL LEVELS The LTC2424/LTC2428’s digital interface is easy to use. Its digital inputs (FO, CSADC, CSMUX, CLK, DIN and SCK in External SCK mode of operation) accept standard TTL/CMOS logic levels and can tolerate edge rates as slow 24 as 100µs. However, some considerations are required to take advantage of exceptional accuracy and low supply current. The digital output signals (SDO and SCK in Internal SCK mode of operation) are less of a concern because they are not generally active during the conversion state. In order to preserve the accuracy of the LTC2424/LTC2428, it is very important to minimize the ground path impedance which may appear in series with the input and/or reference signal and to reduce the current which may flow through this path. The ZSSET pin (Pin 5) should be connected directly to the signal ground. The power supply current during the conversion state should be kept to a minimum. This is achieved by restricting the number of digital signal transitions occurring during this period. LTC2424/LTC2428 U U W U APPLICATIONS INFORMATION While a digital input signal is in the 0.5V to (VCC␣ –␣ 0.5V) range, the CMOS input receiver draws additional current from the power supply. It should be noted that, when any one of the digital input signals (FO, CSADC, CSMUX, DIN, CLK and SCK in External SCK mode of operation) is within this range, the LTC2424/LTC2428 power supply current may increase even if the signal in question is at a valid logic level. For micropower operation and in order to minimize the potential errors due to additional ground pin current, it is recommended to drive all digital input signals to full CMOS levels [VIL < 0.4V and VOH > (VCC – 0.4V)]. Parallel termination near the LTC2424/LTC2428 input pins will eliminate this problem but will increase the driver power dissipation. A series resistor between 27Ω and 56Ω placed near the driver or near the LTC2424/LTC2428 pin will also eliminate this problem without additional power dissipation. The actual resistor value depends upon the trace impedance and connection topology. Driving the Input and Reference The analog input and reference of the typical delta-sigma analog-to-digital converter are applied to a switched capacitor network. This network consists of capacitors switching between the analog input (ADCIN), ZSSET (Pin 5) and the reference (FSSET). The result is small current spikes seen at both ADCIN and VREF. A simplified input equivalent circuit is shown in Figure 18. Severe ground pin current disturbances can also occur due to the undershoot of fast digital input signals. Undershoot and overshoot can occur because of the impedance mismatch at the converter pin when the transition time of an external control signal is less than twice the propagation delay from the driver to LTC2424/LTC2428. For reference, on a regular FR-4 board, signal propagation velocity is approximately 183ps/inch for internal traces and 170ps/inch for surface traces. Thus, a driver generating a control signal with a minimum transition time of 1ns must be connected to the converter pin through a trace shorter than 2.5 inches. This problem becomes particularly difficult when shared control lines are used and multiple reflections may occur. The solution is to carefully terminate all transmission lines close to their characteristic impedance. The key to understanding the effects of this dynamic input current is based on a simple first order RC time constant model. Using the internal oscillator, the internal switched capacitor network of the LTC2424/LTC2428 is clocked at 153,600Hz corresponding to a 6.5µs sampling period. Fourteen time constants are required each time a capacitor is switched in order to achieve 1ppm settling accuracy. Therefore, the equivalent time constant at VIN and VREF should be less than 6.5µs/14 = 460ns in order to achieve 1ppm accuracy. ADCVCC (PIN 2) RSW 5k IREF FSSET IREF SELECTED CHANNEL I IN(MUX) CHX MUXVCC (PIN 8) ±IDC RSW 75Ω MUXOUT ADCVCC (PIN 2) IIN(LEAK) RSW 5k AVERAGE INPUT CURRENT: IDC = 0.25(VIN – 0.5 • VREF) • f • CEQ ADCIN IIN(MUX) CEQ 1pF (TYP) IIN(LEAK) RSW 5k fOUT = 50Hz, INTERNAL OSCILLATOR: f = 128kHz fOUT = 60Hz, INTERNAL OSCILLATOR: f = 153.6kHz EXTERNAL OSCILLATOR: 2.56kHz ≤ f ≤ 307.2kHz ZSSET 24248 F18 Figure 18. LTC2424/LTC2428 Equivalent Analog Input Circuit 25 LTC2424/LTC2428 U W U U APPLICATIONS INFORMATION If complete settling occurs on the input, conversion results will be unaffected by the dynamic input current. If the settling is incomplete, it does not degrade the linearity performance of the device. It simply results in an offset/ full-scale shift, see Figure 19. To simplify the analysis of input dynamic current, two separate cases are assumed: large capacitance at VIN (CIN > 0.01µF) and small capacitance at VIN (CIN < 0.01µF). If the total capacitance at VIN (see Figure 20) is small (< 0.01µF), relatively large external source resistances (up to 20k for 20pF parasitic capacitance) can be tolerated without any offset/full-scale error. Figures 21 and 22 show a family of offset and full-scale error curves for various small valued input capacitors (CIN < 0.01µF) as a function of input source resistance. For large input capacitor values (CIN > 0.01µF), the input spikes are averaged by the capacitor into a DC current. The gain shift becomes a linear function of input source resistance independent of input capacitance, see Figures 23 and 24. The equivalent input impedance is 16.6MΩ. This results in ±150nA of input dynamic current at the extreme values of VIN (VIN = 0V and VIN = VREF, when VREF = 5V). This corresponds to a 0.3ppm shift in offset and full-scale readings for every 10Ω of input source resistance. While large capacitance applied to one of the multiplexer channel inputs may result in offset/full-scale shifts, large capacitance applied to the MUXOUT/ADCIN results in linearity errors. The 75Ω on-resistance of the multiplexer switch is nonlinear with input voltage. If the capacitance at node MUXOUT/ADCIN is less than 0.01µF, the linearity is not degraded. On the other hand, excessive capacitance (>0.01µF) results in incomplete settling as a function of the multiplexer on-resistance. Hence, the 50 VCC = 5V VREF = 5V VIN = 0V TA = 25°C 40 OFFSET ERROR (ppm) Input Current (VIN) VREF = FSSET –ZSSET 30 CIN = 0pF CIN = 100pF CIN = 1000pF 20 CIN = 0.01µF 10 0 1 10 TUE 1k 100 RSOURCE (Ω) 10k 100k 24248 F21 Figure 21. Offset vs RSOURCE (Small C) 10 VREF/2 VREF VIN 24248 F19 Figure 19. Offset/Full-Scale Shift CIN CPAR ≅ 20pF CIN = 0pF CIN = 100pF CIN = 1000pF –20 –30 VCC = 5V VREF = 5V VIN = 5V TA = 25°C CH0 TO CH7 –50 LTC2424/ LTC2428 24248 F20 Figure 20. An RC Network at CH0 to CH7 26 –10 –40 RSOURCE INTPUT SIGNAL SOURCE FULL-SCALE ERROR (ppm) 0 0 1 10 CIN = 0.01µF 100 1k RSOURCE (Ω) 10k 100k 24248 F22 Figure 22. Full-Scale Error vs RSOURCE (Small C) LTC2424/LTC2428 U W U U APPLICATIONS INFORMATION 60 35 CIN = 22µF CIN = 10µF CIN = 1µF CIN = 0.1µF CIN = 0.01µF CIN = 0.001µF 25 FULL-SCALE ERROR (ppm) OFFSET ERROR (ppm) 30 CVREF = 22µF CVREF = 10µF CVREF = 1µF CVREF = 0.1µF CVREF = 0.01µF CVREF = 0.001µF 50 20 VCC = 5V VREF = 5V 15 VIN = 0V TA = 25°C 10 40 30 VCC = 5V VREF = 5V 20 VIN = 5V TA = 25°C 10 0 5 –10 0 0 200 400 600 RSOURCE (Ω) 0 1000 800 200 400 600 800 RESISTANCE AT VREF (Ω) 24248 F25 24248 F23 Figure 23. Offset vs RSOURCE (Large C) Figure 25. Full-Scale Error vs RVREF (Large C) 5 500 VCC = 5V = 5V V 400 VREF= 5V IN TA = 25°C 300 VCC = 5V VREF = 5V VIN = 0V TA = 25°C –5 –10 –15 –20 CIN = 22µF CIN = 10µF CIN = 1µF CIN = 0.1µF CIN = 0.01µF CIN = 0.001µF –25 –30 0 200 400 600 RSOURCE (Ω) VOLTAGE FULL-SCALE ERROR (ppm) 0 –35 1000 CVREF = 1000pF CVREF = 100pF 200 CVREF = 0.01µF 100 0 CVREF = 0pF –100 800 1000 24248 F24 Figure 24. Full-Scale Error vs RSOURCE (Large C) nonlinearity of the multiplexer switch is seen in the overall transfer characteristic. In addition to the input current spikes, the input ESD protection diodes have a temperature dependent leakage current. This leakage current, nominally 1nA (±10nA max), results in a fixed offset shift of 10µV for a 10k source resistance. Reference Current (VREF) Similar to the analog input, the reference input has a dynamic input current. This current has negligible effect on the offset. However, the reference current at VIN = VREF is similar to the input current at full-scale. For large values of reference capacitance (CVREF > 0.01µF), the full-scale –200 1 10 100 1k 10k RESISTANCE AT VREF (Ω) 100k 24248 F26 Figure 26. Full-Scale Error vs RVREF (Small C) error shift is 0.03ppm/Ω of external reference resistance independent of the capacitance at VREF, see Figure 25. If the capacitance tied to VREF is small (CVREF < 0.01µF), an input resistance of up to 80k (20pF parasitic capacitance at VREF) may be tolerated, see Figure 26. Unlike the analog input, the integral nonlinearity of the device can be degraded with excessive external RC time constants tied to the reference input. If the capacitance at node VREF is small (CVREF < 0.01µF), the reference input can tolerate large external resistances without reduction in INL, see Figure 27. If the external capacitance is large (CVREF > 0.01µF), the linearity will be degraded by 0.015ppm/Ω independent of capacitance at VREF, see Figure 28. 27 LTC2424/LTC2428 U W U U APPLICATIONS INFORMATION 50 256 • FO, where FO is the notch frequency (typically 50Hz or 60Hz). The bandwidth of signals not rejected by the digital filter is narrow (≈ 0.2%) compared to the bandwidth of the frequencies rejected. INL ERROR (ppm) VCC = 5V = 5V V 40 T REF A = 25°C 30 CVREF = 1000pF 20 CVREF = 100pF 10 CVREF = 0.01µF 0 –10 CVREF = 0pF –20 1 10 100 1k 10k RESISTANCE AT VREF (Ω) 100k 24248 F27 Figure 27. INL Error vs RVREF (Small C) 10 CVREF = 22µF CVREF = 10µF CVREF = 1µF CVREF = 0.1µF CVREF = 0.01µF CVREF = 0.001µF 8 INL ERROR (ppm) 6 4 2 As a result of the oversampling ratio (256) and the digital filter, minimal (if any) antialias filtering is required in front of the LTC2424/LTC2428. If passive RC components are placed in front of the LTC2424/LTC2428, the input dynamic current should be considered. In cases where large effective RC time constants are used, an external buffer amplifier may be required to minimize the effects of input dynamic current. The modulator contained within the LTC2424/LTC2428 can handle large-signal level perturbations without saturating. Signal levels up to 40% of VREF do not saturate the analog modulator. These signals are limited by the input ESD protection to 300mV below ground and 300mV above VCC. VCC = 5V VREF = 5V TA = 25°C 0 –2 0 –4 fS = 15,360Hz –20 –6 –10 0 200 400 600 800 RESISTANCE AT VREF (Ω) 1000 24248 F28 REJECTION (dB) –40 –8 –60 –80 –100 Figure 28. INL Error vs RVREF (Large C) In addition to the dynamic reference current, the VREF ESD protection diodes have a temperature dependent leakage current. This leakage current, nominally 1nA (±10nA max), results in a fixed full-scale shift of 10µV for a 10k source resistance. Antialiasing One of the advantages delta-sigma ADCs offer over conventional ADCs is on-chip digital filtering. Combined with a large oversampling ratio, the LTC2424/LTC2428 significantly simplify antialiasing filter requirements. The digital filter provides very high rejection except at integer multiples of the modulator sampling frequency (fS), see Figure 29. The modulator sampling frequency is 28 –120 –140 0 fS/2 fS INPUT FREQUENCY 24248 F29 Figure 29. Sync4 Filter Rejection Using a Low Power Precision Reference The circuit in Figure 30 shows the connections and bypassing for an LT1461-2.5 as a 2.5V reference. The LT1461 is a bandgap reference capable of 3ppm/°C temperature stability yet consumes only 45µA of current. The 1k resistor between the reference and the ADC reduces the transient load changes associated with sampling and produces optimal results. This reference will not impact the noise level of the LTC2424/LTC2428 if signals are less LTC2424/LTC2428 U U W U APPLICATIONS INFORMATION 1k 5V IN OUT 0.1µF LT1461-2.5 CER + 10µF 16V TANT TO LTC2424/LTC2428 FSSET GND 24248 F30 Figure 30. Low Power Reference than 60% full scale, and only marginally increases noise approaching full scale. Even lower power references can be used if only the lower end of the LTC2424/LTC2428 input range is required. 2.051MHz Oscillator for 100sps Output Ratio The oscillator circuit shown in Figure 31 can be used to drive the FO pin, boosting the conversion rate of the LTC2420 for applications that do not require a notch at 50 or 60Hz. This oscillator is not sensitive to hysteresis voltage of a Schmitt trigger device as are simpler relaxation oscillators using the 74HC14 or similar devices. The circuit can be tuned over a 3-1 range with only one resistor and can be gated. The use of transmission gates could be used to shift the frequency in order to provide setable conversion rates. Pseudodifferential Multichannel Bridge Digitizer and Digital Cold Junction Compensation The circuit shown in Figure 32 enables pseudodifferential measurements of several bridge transducers and absolute temperature measurement. Consecutive readings are performed on each side of the bridge by selecting the appropriate channel on the LTC2428. Each output is digitized and the results digitally subtracted to obtain the pseudodifferential result. Several bridge transducers may be digitized in this manner. In order to measure absolute temperature with a thermocouple, cold junction compensation must be performed. Channel 6 measures the output of the thermocouple while channel 7 measures the output of the cold junction sensor (diode, thermistor, etc.). This enables digital cold junction compensation of the thermocouple output. The temperature measurement may then be used to compensate the temperature effects of the bridge transducers. 1k 1k 10k U1-F 47k 12 2N3904 5k 13 47k 5pF 270pF U1-A 1 U1-B 2 U1-C 3 4 5 6 U1-E 10pF 11 10 U1-D 100smps, FO = 2.048MHz 30smps, FO = 614.4kHz U1: 74HC14 OR EQUIVALENT 9 8 TO LTC2424/ LTC2428 24248 F31 FO PIN Figure 31. 2.051MHz Oscillator for 100sps Output Rate 5V 7 MUXOUT THERMOCOUPLE THERMISTOR HALT 4 ADCIN 5V 3 2, 8 FSSET VCC 1µF 9 CH0 10 CH1 CSADC 11 CH2 CSMUX 12 CH3 13 CH4 14 CH5 15 CH6 17 CH7 8-CHANNEL MUX + 20-BIT ∆Σ ADC SCK CLK DIN – SDO 23 20 25 19 21 24 VCC LTC2428 5 ZSSET FO GND 1, 6, 16, 18, 22, 27, 28 26 24248 F32 Figure 32. Pseudodifferential Multichannel Bridge Digitizer and Digital Cold Junction Compensation 29 LTC2424/LTC2428 U U W U APPLICATIONS INFORMATION The LTC2428’s Resolution and Accuracy Allows You to Measure Points in a Ladder of Sensors The resistance of any of the RTDs (PT1 to PT7) is determined from the voltage across it, as compared to the voltage drop across the reference resistor (R1). This is a ratiometric implementation where the voltage drop across R1 is given by VREF – VCH1. Channel 7 is used to measure the voltage on a representative length of wire. If the same type and length of wire is used for all connections, then errors associated with the voltage drops across all wiring can be removed in software. The contribution of wiring drop can be scaled if wire lengths are not equal. In many industrial processes, for example, cracking towers in petroleum refineries, a group of temperature measurements must be related to one another. A series of platinum RTDs that sense slow changing temperatures can be configured into a resistive ladder, using the LTC2428 to sense each node. This approach allows a single excitation current passed through the entire ladder, reducing total supply current consumption. In addition, this approach requires only one high precision resistor, thereby reducing cost. A group of up to seven temperatures can be measured as a group by a single LTC2428 in a loop-powered remote acquisition unit. In the example shown in Figure 33, the excitation current is 240µA at 0°C. The LTC2428 requires 300µA, leaving nearly 3.5mA for the remainder of the remote transmitter. Gain can be added to this circuit as the total voltage drop across all the RTDs is small compared to ADC full-scale range. The maximum recommended gain is 50, as limited by both amplifier noise contribution, as well as the maximum voltage developed at CH0 when all sensors are at the maximum temperature specified for platinum RTDs. 5V 300µA + R2 6 47µF 3 4 5 + 7 6 LTC1050 2 R1 20.1k 0.1% UP TO SEVERAL HUNDRED FEET. ALL SAME WIRE TYPE PT1 100Ω PLATINUM RTD R2 5V OPTIONAL PROTECTION RESISTORS 5k MAX 7 MUXOUT 3 2, 8 FSSET VCC 1µF 9 CH0 CSADC 11 CH2 CSMUX 14 CH5 PT7 4 ADCIN 10 CH1 13 CH4 TO PT3-PT6 4 R3 12 CH3 PT2 – 0.1µF OPTIONAL GAIN BLOCK 5V LTC1634-2.5 15 CH6 17 CH7 8-CHANNEL MUX + 20-BIT ∆Σ ADC SCK CLK DIN – SDO 23 20 25 19 21 24 VCC LTC2428 5 ZSSET GND 1, 6, 16, 18, 22, 27, 28 FO 26 24248 F33 Figure 33. Measuring Up to Seven RTD Temperatures with One Reference Resistor and One Reference Current 30 LTC2424/LTC2428 U U W U APPLICATIONS INFORMATION Adding gain requires that one of the resistors (PT1 to PT7) be a precision resistor in order to eliminate the error associated with the gain setting resistors R2 and R3. Note, that if a precision (100Ω to 400Ω) resistor is used in place of one of the RTDs (PT7 recommended), R1 does not need to be a high precision resistor. Although the substitution of a precision reference resistor for an RTD to determine gain may suggest that R2 and R3 (and R1) need not be precise, temperature fluctuations due to airflow may appear as noise that cannot be removed in firmware. Consequently, these resistors should be low temperature coefficient devices. The use of higher resistance RTDs is not recommended in this topology, although the inclusion of one 1000Ω RTD at the top on the ladder will have minimal impact on the lower elements. The same caveat applies to fast changing temperatures. Any fast changing sensors should be at the top of the ladder. The LTC2428’s Uncommitted Multiplexer Finds Use in a Programmable Gain Scheme If the multiplexer in the LTC2428 is not committed to channel selection, it can be used to select various signalprocessing options such as different gains, filters or attenuator characteristics. In Figure 34, the multiplexer is shown selecting different taps on an R/2R ladder in the feedback loop of an amplifier. This example allows selection of gain from 1 to 128 in binary steps. Other feedback networks could be used to provide gains tailored for specific purposes. (For example, 1x, 1.1x, 1.41x, 2x, 2.028x, 5x, 10x, 40x, etc.) Alternatively, different bandpass characteristics or signal inversion/noninversion could be selected. The R/2R ladder can be purchased as a network to ensure tight temperature tracking. Alternatively, resistors in a ladder or as separate dividers can be assembled from discrete resistors. In the configuration shown, the 5V VIN 3 AV = 1, 2, 4...128 + LTC1050 2 6 – 5V 0.1V TO VCC 10k 20k 20k 10k 8 20k 32 64 10k 20k 10k 14 CH5 15 CH6 10k 20k 12 CH3 13 CH4 10k 10k 10 CH1 1µF CSADC 11 CH2 16 20k 3 2, 8 FSSET VCC 4 ADCIN 9 CH0 10k 4 20k 7 MUXOUT 2 17 CH7 5 ZSSET CSMUX 8-CHANNEL MUX + 20-BIT ∆Σ ADC SCK CLK DIN – SDO 23 20 25 19 21 24 VCC LTC2428 GND 1, 6, 16, 18, 22, 27, 28 FO 26 24248 F34 128 Figure 34. Using the Multiplexer to Produce Programmable Gains of 1 to 128 31 LTC2424/LTC2428 U U W U APPLICATIONS INFORMATION channel resistance of the multiplexer does not contribute much to the error budget, as only input op amp current flows through the switch. The LTC1050 was chosen for its low input current and offset voltage, as well as its ability to drive the input of a ∆Σ ADC. Insert Gain or Buffering After the Multiplexer Separate MUXOUT and ADCIN terminals permit insertion of a gain stage between the MUX and the ADC. If passive filtering is used at the input to the ADC, a buffer amplifier is strongly recommended to avoid errors resulting from the dynamic ADC input current. If antialiasing is required, it should be placed at the input to the MUX. If bandwidth limiting is required to improve noise performance, a filter with a –3dB point at 1500Hz will reduce the effective total noise bandwidth of the system to 15Hz. A roll-off at 1500Hz eliminates all higher order images of the base bandwidth of 6Hz. In Figure 35, the optional bandwidth-limiting filter has a – 3dB point at 1450Hz. This filter can be inserted after the multiplexer provided that higher source impedance prior to the multiplexer does not reduce the – 3dB frequency, extending settling time, and resulting in charge sharing between samples. The settling time of this filter to 20+ bits of accuracy is less than 2ms. In the presence of external wideband noise, this filter reduces the apparent noise by a factor of 5. Note that the noise bandwidth for noise developed in the amplifier is 150Hz. In the example shown, the gain of the amplifier is set to 40, the point at which amplifier noise gain dominates the LTC2428 noise. Input voltage range as shown is then 0V to 125mV DC. The recommended capacitor at C2 for a gain of 40 would be 560pF. 5V OPTIONAL BANDWIDTH LIMIT 3 + 7 6 LTC1050 2 C1 0.022µF R1 5.1k – 4 R3 200k R4 5K MAY BE REQUIRED BY OTHER AMPLIFIERS (IS REQUIRED BY BIPOLAR AMPLIFIERS) R2 5.1K C2 OPTIONAL GAIN AND ROLL-OFF 7 MUXOUT ANALOG INPUTS 5V 4 ADCIN 3 2, 8 FSSET VCC 10µF 9 CH0 10 CH1 CSADC 11 CH2 CSMUX 12 CH3 13 CH4 14 CH5 15 CH6 17 CH7 5 ZSSET 8-CHANNEL MUX + 20-BIT ∆Σ ADC SCK CLK DIN – SDO 23 20 25 19 21 24 VCC LTC2428 GND 1, 6, 16, 18, 22, 27, 28 FO 26 24248 F35 Figure 35. Inserting Gain Between the Multiplexer and the ADC Input 32 LTC2424/LTC2428 U W U U APPLICATIONS INFORMATION An 8-Channel DC-to-Daylight Digitizer The circuit in Figure 36 shows an example of the LTC2428’s flexibility in digitizing a number of real-world physical phenomena—from DC voltages to ultraviolet light. All of the examples implement single-ended signal conditioning. Although differential signal conditioning is a preferred approach in applications where the sensor is a bridge-type, is located some distance from the ADC or operates in a high ambient noise environment, the LTC2428’s low power dissipation allows circuit operation in close proximity to the sensor. As a result, conditioning the sensor output can be greatly simplified through the use of single-ended arrangements. In those applications where differential signal conditioning is required, chopper amplifier-based or self-contained instrumentation amplifiers (also available from LTC) can be used with the LTC2428. With the resistor network connected to CH0, the LTC2428 is able to measure DC voltages from 1mV to 1kV in a single range without the need for autoranging. The 990k resistor should be a 1W resistor rated for high voltage operation. Alternatively, the 990k resistor can be replaced with a series connection of several lower cost, lower power metal film resistors. The circuit connected to CH1 shows an LT1793 FET input operational amplifier used as an electrometer for high impedance, low frequency applications such as measuring pH. The circuit has been configured for a gain of 21; thus, the input signal range is –15mV ≤ VIN ≤ 250mV. An amplifier circuit is necessary in these applications because high output impedance sensors cannot drive switched-capacitor ADCs directly. The LT1793 was chosen for its low input bias current (10pA, max) and low noise (8nV/√Hz) performance. As shown, the use of a driven guard (and TeflonTM standoffs) is recommended in high impedance sensor applications; otherwise, PC board surface leakage current effects can degrade results. The circuit connected to CH2 illustrates a precision halfwave rectifier that uses the LTC2428’s internal ∆Σ ADC as an integrator. This circuit can be used to measure 60Hz, 120Hz or from 400Hz to 1kHz with good results. The LTC2428’s internal sinc4 filter effectively eliminates any frequency in this range. Above 1kHz, limited amplifier gain-bandwidth product and transient overshoot behavior can combine to degrade performance. The circuit’s dynamic range is limited by operational amplifier input offset voltage and the system’s overall noise floor. Using an LTC1050 chopper-stabilized operational amplifier with a VOS of 5µV, the dynamic range of this application covers approximately 5 orders of magnitude. The circuit configuration is best implemented with a precision, 3-terminal, 2-resistor 10kΩ network (for example, an IRC PFC-D network) for R6 and R7 to maintain gain and temperature stability. Alternatively, discrete resistors with 0.1% initial tolerance and 5ppm/°C temperature coefficient would also be adequate for most applications. Two channels (CH3 and CH4) of the LTC2428 are used to accommodate a 3-wire 100Ω, Pt RTD in a unique circuit that allows true RMS/RF signal power measurement from audio to gigahertz (GHz) frequencies. The unique feature of this circuit is that the signal power dissipated in the 50Ω termination in the form of heat is measured by the 100Ω RTD. Two readings are required to compensate for the RTD’s lead-wire resistance. The reading on CH4 is multiplied by 2 and subtracted from the reading on CH3 to determine the exact value of the RTD. While the LTC2428 is capable of measuring signals over a range of five decades, the implementation (mechanical, electrical and thermal) of this technique ultimately determines the performance of the circuit. The thermal resistance of the assembly (the 50Ω/RTD mass to its enclosure) will determine the sensitivity of the circuit. The dynamic range of the circuit will be determined by the maximum temperature the assembly is rated to withstand, approximately 850°C. Details of the implementation are quite involved and are beyond the scope of this document. Please contact LTC directly for a more comprehensive treatment of this implementation. In the circuit connected to the LTC2428’s CH5 input, a thermistor is configured in a half-bridge arrangement that Teflon is a trademark of Dupont Company. 33 LTC2424/LTC2428 U W U U APPLICATIONS INFORMATION could be used to measure the case temperature of the RTD-based thermal power measurement scheme described previously. In general, thermistors yield very good resolution over a limited temperature range. For the half-bridge arrangement shown, the LTC2428 can measure temperature changes over nearly 5 orders of magnitude. Connected to the LTC2428’s CH6 input, an infrared thermocouple (Omega Engineering OS36-1) can be used in limited range, noncontact temperature measurement applications or applications where high levels of infrared light must be measured. Given the LTC2428’s 1.2ppmRMS noise performance, measurement resolution using infrared thermocouples is approximately 0.25°C—equivalent to the resolution of a conventional Type J thermocouple. These infrared thermocouples are self-contained: 1) they do not require external cold junction compensation; 2) they cannot use conventional open thermocouple detection schemes; and 3) their output impedances are high, approximately 3kΩ. Alternatively, conventional thermocouples can be connected directly to the LTC2428 (not shown) and cold junction compensation can be provided by an external temperature sensor connected to a different 34 channel (see the thermistor circuit on CH5) or by using the LT1025, a monolithic cold-junction compensator IC. The components connected to CH7 are used to sense daylight or photodiode current with a resolution of 300pA. In the figure, the photodiode is biased in photoconductive mode; however, the LTC2428 can accommodate either photovoltaic or photoconductive configurations. The photodiode chosen (Hammatsu S1336-5BK) produces an output of 500mA per watt of optical illumination. The output of the photodiode is dependent on two factors: active detector area (2.4mm • 2.4mm) and illumination intensity. With the 5k resistor, optical intensities up to 368W/m2 at 960nM (direct sunlight is approximately 1000W/m2) can be measured by the LTC2428. With a resolution of 1nA, the optical dynamic range covers 5 orders of magnitude. The application circuits shown connected to the LTC2428 demonstrate the mix-and-match capabilities of this multiplexed-input, high resolution ∆Σ ADC. Very low level signals and high level signals can be accommodated with a minimum of additional circuitry. LTC2424/LTC2428 U PACKAGE DESCRIPTIO Dimensions in millimeters (inches) unless otherwise noted. G Package 28-Lead Plastic SSOP (0.209) (LTC DWG # 05-08-1640) 10.07 – 10.33* (0.397 – 0.407) 28 27 26 25 24 23 22 21 20 19 18 17 16 15 7.65 – 7.90 (0.301 – 0.311) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 5.20 – 5.38** (0.205 – 0.212) 1.73 – 1.99 (0.068 – 0.078) 0° – 8° 0.13 – 0.22 (0.005 – 0.009) 0.55 – 0.95 (0.022 – 0.037) NOTE: DIMENSIONS ARE IN MILLIMETERS *DIMENSIONS DO NOT INCLUDE MOLD FLASH. MOLD FLASH SHALL NOT EXCEED 0.152mm (0.006") PER SIDE **DIMENSIONS DO NOT INCLUDE INTERLEAD FLASH. INTERLEAD FLASH SHALL NOT EXCEED 0.254mm (0.010") PER SIDE 0.65 (0.0256) BSC 0.25 – 0.38 (0.010 – 0.015) Information furnished by Linear Technology Corporation is believed to be accurate and reliable. However, no responsibility is assumed for its use. Linear Technology Corporation makes no representation that the interconnection of its circuits as described herein will not infringe on existing patent rights. 0.05 – 0.21 (0.002 – 0.008) G28 SSOP 1098 35 LTC2424/LTC2428 U TYPICAL APPLICATION GUARD RING 5V ELECTROMETER INPUT (pH, PIEZO) 3 7 + LT1793 2 R5 5k, 1% 6 DC VOLTMETER INPUT 1mV TO 1000V R1 900k 0.1%, 1W, 1000 WVDC R2 4.7k 0.1% – 0V TO 5V 4 –5V 5V REF + R4 1k –60mV TO 4V R3, 10k C1, 0.1µF 5V MAX LT1236CS8-5 6 2 OUT IN + GND 4 10µF 3-WIRE R-PACK 60Hz + AC INPUT R6 10k, 0.1% 100µF R7 10k, 0.1% 5V 5V 1µF 2 RT 7 – IN914 3 R9 1k 1% IN914 R10 5k 1% 6 LTC1050 R8 100Ω, 5% + 4 20mV TO 80mV –5V R11 24.9k, 0.1% V REF 5V 60Hz–RF RF POWER 7 MUXOUT 9 CH0 10 CH1 11 CH2 12 CH3 13 CH4 14 CH5 15 CH6 17 CH7 5 50Ω 8V + 100Ω Pt RTD (3-WIRE) 3 2, 8 FSSET VCC 1µF CSADC CSMUX 8-CHANNEL MUX + 20-BIT ∆Σ ADC CLK DIN – SDO 23 20 FO GND 1, 6, 16, 18, 22, 27, 28 SERIAL DATA LINK MICROWIRE AND SPI COMPATABLE 19, 25 MPU 21 24 LTC2428 ZSSET <1mV J1 4 ADCIN 26 INTERNAL OSC SELECTED FOR 60Hz REJECTION 24248 F36 FORCE SENSE J2 2.7V AT 0°C 0.9V AT 40°C 50Ω LOAD BONDED TO RTD ON INSULATED MOUNTING –2.2mV to 16mV R12 24.9k, 0.1% V REF 5V J3 LOCAL TEMP THERMISTOR 10kΩ NTC 0V to 4V 5V DAYLIGHT HAMAMATSU PHOTODIODE S1336-5BK OMEGA 0S36-01 INFRARED INFRARED THERMOCOUPLE R13 5k 0.1% Fiugre 36. Measure DC to Daylight Using the LTC2428 RELATED PARTS PART NUMBER DESCRIPTION COMMENTS LTC2400 24-Bit µPower, No Latency ∆Σ ADC in SO-8 4ppm INL, 10ppm TUE, 200µA, Pin Compatible with LTC2420 LTC2401/LTC2402 1-/2-Channel, 24-Bit No Latency ∆Σ ADCs 24 Bits in MSOP Package LTC2410 24-Bit No Latency ∆Σ ADC with Differential Inputs 800nV Noise, Differential Reference, 2.7V to 5.5V Operation LTC2411 24-Bit No Latency ∆Σ ADC with Differential Inputs/Reference 1.6µV Noise, Fully Differential, 10-Lead MSOP Package LTC2413 24-Bit No Latency ∆Σ ADC Simultaneous 50Hz to 60Hz Rejection 0.16ppm Noise LTC2404/LTC2408 4/8 Channel, 24-Bit ∆Σ ADCs < 4ppm INL, No Missing Codes LTC2420 20-Bit No Latency ∆Σ ADC Fast Mode Allows 100sps, Low Cost 36 Linear Technology Corporation 24248f LT/TP 0201 4K • PRINTED IN USA 1630 McCarthy Blvd., Milpitas, CA 95035-7417 (408)432-1900 ● FAX: (408) 434-0507 ● www.linear-tech.com LINEAR TECHNOLOGY CORPORATION 2000