POWER-ONE HP6-X8X4D2D-O

Multi-Output HP6 Front End
and RACK-HP600 Data Sheet
HP6 and RACK-HP600 Features
• Compact 1U design
• N+1 redundancy with hot plug capability
• Up to four individually regulated outputs
• I2C interface with interrupt capability
• Hot swap with low insertion/extraction force connector
• Power factor corrected
• No minimum load required
• 5 V @ 1 A standby output
• Single-wire current sharing
• Self-contained ORing Diodes
• Current limit and over-voltage protection
• Full power up to 50º C
• TUV, cTUVus & CB report
• 600 watts per module
• Ac input with PFC
HP6 Multi-Output AC-DC Front End
RACK-HP600
Description
The HP6 provides up to 600 Watts total output power with one to four outputs ranging from 0.8 to 12 Volts. HP600
RACKS offer hot-plug capability for up to 1200 Watts total at low line (2 +1) or 1800 Watts total at high line. Three
separate multi output power supplies are internally paralleled and will automatically current share for load
distribution. Hot-swap modules can be replaced with no system downtime.
V1
HP6 Front End Models
HP6-X8X8D2D-O
HP6-X4X8D4D-O
HP6-X8X4D4D-O
HP6-X8X4D2D-O
HP6-X4X8D2D-O
HP6-X4X4D4D-O
RACK-HP600 Designations
RACK-HP600
V2
Volts
X
X
X
X
X
X
Amps
80
40
80
80
40
40
Volts
X
X
X
X
X
X
Amps
80
80
40
40
80
40
Volts
12
12
12
12
12
12
X
240
X
120
12
V3
Amps
20
40
40
20
20
40
120
Volts
-12
-12
-12
-12
-12
-12
V4
Amps
3
3
3
3
3
3
-12
9
Output Voltage X = A (2.0V); B (3.3V); C (5V); T (2.5V); V (1.8V); W (1.5V); X (1.2V); Y (1V); Z (0.8V)
2
Options O = B (I C); M (Output power good – TTL high); N (Power fail – TTL high); R (Reverse airflow)
Please contact Power-One for additional model combinations.
Nov 7, 2006
Page 1 of 4
www.power-one.com
Multi-Output HP6 Front End
and RACK-HP600 Data Sheet
Input Specifications
Signals and Controls
Input voltage range: 85 to 264 Vac, 47 to 63 Hz
Power Factor: 0.99 at full load and nominal line
Inrush Current: 40 A peak hot and cold start
Input Protection: Internal 15 A line fuse
LED Output Good Indicator: Front panel green LED indicates
power supply is good; amber indicates fault.
LED AC Good Indicator: Front panel green LED indicates
Ac input voltage is present and above minimum level.
Output Good Signal*: TTL compatible signal, normally high.
Goes low when power supply is out of specified range.
Power Fail Signal*: TTL compatible signal, normally high
(indicating Vin is present and above minimum level).
Enable*: Normally TTL High, drive low to enable.
*All interface signals are TTL compatible
Output Specifications
Output Power: 600 W maximum
Overshoot/Undershoot: Less than 1% at turn-on or turnoff. Less than 3% for 50% to 100% load step.
Start-Up Time: Less than 2 seconds
Efficiency: 78% typical measured at full load, nominal input
Hold-up Time: 20 ms minimum at full load and low line
Single Wire Current Share (V1, V2 and +12V): 10% full
load rating.
Load Regulation: 0.5% with remote sense, 2% without
Line Regulation: 0.1% over entire operating range
Cross Regulation: Less than 0.5%
Minimum Load: No minimum load required
Overcurrent Protection: All outputs set to 115-135% of full
rated load with automatic recovery
Overtemperature Protection: Automatic shutdown with
auto recovery.
Remote Sense: Compensates for voltage drop of up to 0.5
V to the load (V1, V2, and +12V). Shorted sense lead
protection.
Overvoltage Protection: All outputs set at 115%-135% of
nominal. Reset by cycling input power.
Output Noise and Ripple: PARD: 1% or 50 mV p-p,
whichever is greater, measured at 20 Mhz bandwidth.
Mechanical Specifications
Size: 1.6” H x 5” W x 11.5” D
Input Connector: Front panel IEC
Output Connector: FCI power blade
MTBF: 250,000 hours calculated at 25 °C, Bellcore
Standard
Warranty: Two years from date of shipment, standard
product only.
Specifications are subject to change without prior notice.
Nov 7, 2006
I2C Interface
Event Driven Messages:
• Notification of fan speed abnormality
• Output voltage under specified ‘good’ range
• Output voltage over specified ‘good’ range (software OVP)
• Temperature abnormalities
Sensor Device Commands:
• Get voltage readings
• Get temperature readings
• Get fan speed readings
FRU (Field Replaceable Unit) Information Storage:
• Manufacturer’s name
• Product name
• Product part/model number
• Product version/revision
• Product serial number
Safety & Environmental
Operating Temperature: 0 to 50°C
Storage Temperature: -40°C to +85°C
Operating Humidity: Maximum 95% RH non-condensing
Operating Altitude: 10,000 feet
Non-operating Altitude: 40,000 feet
Temperature Coefficient: 0.02% per °C within rated load
Safety Agency Compliance: TUV, cTUVus & CB report
EMI: Meets EN55022, Class B
Harmonic Suppression: Meets EN6100-3-2
Input Transient Protection:
Electrostatic Discharge: EN61000-4-2, Criteria B
Radiated, Radio-Frequency, Electromagnetic Field:
EN61000-4-3, Criteria A
Electrical Fast Transients/Burst: EN61000-4-4, Criteria B
Voltage Fluctuations and Flickers: EN61000-3-3, Criteria B
Surge Test: EN61000-4-5, Criteria B
Conducted Immunity: EN61000-4-6, Criteria A
Dielectric Withstand:
Input-to-ground: 2200 Vdc
Input-to-output: 4300 Vdc
Output-to-case: 25 Vdc
Ac Leakage Current: 1.2mA maximum at 240 Vac, 50 Hz
Page 2 of 4
www.power-one.com
Multi-Output HP6 Front End
and RACK-HP600 Data Sheet
HP6 Outline Drawings and Dimensions
HP6 Connector Pin Descriptions
HP6 J5 Connector Detail
HP6 PIN Numbers and Signal Names
1 Ground
2 Ground
3 V2 Output
4 V2 Output
5 V2 Output
6 Ground
7 Ground
8 Ground
9 V1 Output
10 V1 Output
11 V1 Output
12 Dc Enable
13 A1
14 -Sense
15 +Sense V1
16 V4 Output (-12V)
17 V4 Output (-12V)
Nov 7, 2006
18 Share V2
19 +Sense V2
20 SDA
21 SCL
22 Share V3
23 Power Fail OK
24 5V Standby
25 5V Standby
26 +Sense V3
27 Power OK
28 Present
29 A0
30 Interrupt
31 Share V1
32 Ground
33 V3 Output (+12V)
34 V3 Output (+12V)
Page 3 of 4
www.power-one.com
Multi-Output HP6 Front End
and RACK-HP600 Data Sheet
RACK-HP600 Outline Drawings and Dimensions
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written
consent of the respective divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on
the date manufactured. Specifications are subject to change without notice.
Nov 7, 2006
Page 4 of 4
www.power-one.com