ARTESYN N1000-96-9

N1000 and N1200 SERIES
Single, dual, triple and quad output
•
•
•
•
•
•
•
•
The N1000 and N1200 series are a range of systems-orientated, one to four
output power supplies which provide 1000W or 1200W of continuous power at
line voltages from 90VAC to 264VAC. Both series are harmonically corrected and
carry world wide safety approvals. Fully enclosed, fan cooled and in the industry
standard 5 x 8 x 11 inch form, the N series is an ideal choice when the economy
and predictable performance of a centralized system power supply are desired. A
unique dual converter architecture isolates the 5VDC logic output and the
peripheral voltages. Maximum flexibility is provided as power budgets shift and
change during the design cycle or as system upgrades are implemented. This
overcomes a major shortfall of many system power supplies which use a single
converter. To meet redundancy requirements, each output rail is isolated,
individually regulated and features forced current share. System interface signals
include AC and DC Good, current monitor (V1), overvoltage, OCP, overtemperature protection, remote enable, margin check and inhibit as standard. By
combining robust performance and broad range, the N Series sets the standard
for centralized system power supplies.
[ 2 YEAR WARRANTY ]
SPECIFICATION
OUTPUT SPECIFICATIONS
Active harmonic correction to EN61000-3-2
90VAC to 264VAC universal input
Flexible output voltage configuration
Two output power ratings
Forced current sharing, all outputs
DC OK (including LED)
UL, CSA and TÜV safety approvals
Industry standard 5 x 8 x 11 inch footprint
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
(2)
EMC CHARACTERISTICS
Voltage adjustability
Accessible at front panel
Remote sense
Open/reverse sense lead protection
Compensates for voltage drop of up to
0.5V to the load
Regulation, line or load All outputs, NL-FL
at nominal line or all
line variations at FL
Cross regulation
±0.2%;
10mV min.
0.2% max. or 10mV between outputs
Overshoot/undershoot
Transient response
None at turn on/off
≤2.0% max. dev.,
≤200µs recovery
to 1.0%
Main output
25% step load
change at 1A/µs
Temperature coefficient
0Hz to 20MHz
Overvoltage protection
Reset by cycling AC
Overload protection
50mV pk-pk or 1%
115 to 130%
of nominal
105-115% full load
All outputs
Thermal protection
Auto recovery
EN55022/11, FCC part 15
EN55022/11, FCC part 15
EN61000-3-2
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
±5.0%
50% to 100% load
Current monitor (V1)
5VDC at full load
±0.5V
INPUT SPECIFICATIONS
Input voltage range
90 to 264VAC
Input frequency range
47Hz to 63Hz
Input surge current
Meets IEEE std. 587.1980;
3KV ring wave
Input current
120VAC, 1000W
Power factor
115/230VAC, 1kW load
Power up time
Full load
1.0s max.
Level 3
Hold-up time
90VAC, 1KW load
24ms min.
Efficiency
230VAC, full load
73%
Isolation voltage
Input/output
Input/chassis
Output/output
3000VAC
1500VAC
500VAC
Switching frequency
100kHz
Approvals and
standards
EN60950, UL1950,
CSA C22.2 No. 950
Weight
6.9kg (15Ibs)
Size
MTBF
5 x 8 x 11 inches
127 x 203.2 x 279.4 mm
per MIL-HDBK-217E
100,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating ambient
Non-operating
Cooling
60CFM
Relative humidity
Non-condensing
Altitude
Operating
Non-operating
Vibration
5Hz to 500Hz
12A
0.995 min.
Level A
Level A
Conforms
Level 3
Level 3
Level 3
GENERAL SPECIFICATIONS
Auto shutdown, AC reset
Current sharing
PAGE 1
Radiated emissions
Conducted emissions
Harmonic distortion
Electrostatic discharge
RF field susceptibility
Electrical fast
transients/bursts
Surge susceptibility
±0.02%/°C
Ripple and noise
Short circuit protection
±10%
0°C to +50°C
-15°C to +85°C
Internal DC ball bearing fan
0% to 95% RH
6,000 feet max.
55,000 feet max.
2.4G rms peak
MEDIUM TO HIGH POWER AC/DC POWER SUPPLIES
|
1000-1200W AC/DC
1000 and 1200 Watt
AC/DC high wattage power supplies with PFC
MAX. OUTPUT
POWER
(1)
OUTPUT V1
OUTPUT V2
OUTPUT V3
OUTPUT V4
VOLTAGE/CURRENT
VOLTAGE/CURRENT
VOLTAGE/CURRENT
VOLTAGE/CURRENT
MODEL NUMBER
1000W
3.3V @ 200A
N1000-96-9
1000W
5.0V @ 200A
N1000-96-1
1000W
5.0V @ 150A
12V @ 25A
12V @ 20A
N1000-96-122
1000W
5.0V @ 150A
12V @ 30A
5.0V @10A
N1000-96-121
1000W
5.0V @ 150A
12V @ 25A
12V @ 15A
5V @ 10A
N1000-96-1221
1000W
5.0V @ 150A
12V @ 25A
12V @ 10V
24V @ 5.0A
N1000-96-1224
1000W
5.0V @ 150A
5.0V @ 30A
12V @ 20V
12V @ 10A
N1000-96-1122
1000W
5.0V @ 150A
3.3V @ 30A
12V @ 20A
12V @ 10A
N1000-96-1922
1000W
5.0V @ 150A
24V @ 15A
12V @ 10A
12V @ 5.0A
N1000-96-1422
1200W
2.0V @ 240A
N1200-96-0
1200W
3.3V @ 240A
N1200-96-9
1200W
5.0V @ 240A
N1200-96-1
1200W
12V @ 100A
N1200-96-2
1200W
24V @ 50A
N1200-96-4
1200W
28V @ 43A
N1200-96-5
1200W
48V @ 25A
N1200-96-6
1200W
5.0V @ 200A
12V @ 40A
N1200-96-12
1200W
5.0V @ 200A
24V @ 20A
N1200-96-14
1200W
48V @ 25A
24V @ 20A
N1200-96-64
1200W
5.0V @ 175A
12V @ 30A
12V @ 20A
N1200-96-122
1200W
5.0V @ 175A
12V @ 35A
5V @ 20A
N1200-96-121
1200W
5.0V @ 175A
12V @ 30A
24V @ 15A
N1200-96-124
1200W
5.0V @ 175A
3.3V @ 40A
12V @ 20A
N1200-96-192
1200W
5.0V @ 175A
12V @ 30A
12V @ 20A
5V @ 10A
N1200-96-1221
1200W
5.0V @ 175A
12V @ 30A
12V @ 10A
24V @ 5A
N1200-96-1224
1200W
5.0V @ 175A
15V @ 30A
15V @ 10A
5V @ 10A
N1200-96-1331
1200W
5.0V @ 175A
5.0V @ 40A
12V @ 20A
12V @ 10A
N1200-96-1122
1200W
5.0V @ 175A
3.3V @ 40A
12V @ 20A
12V @ 10A
N1200-96-1922
1200W
5.0V @ 175A
24V @ 20A
12V @ 10A
12V @ 5A
N1200-96-1422
1200W
24V @ 42A
5.0V @ 40A
12V @ 20A
12V @ 10A
N1200-96-4122
International Safety Standard Approvals
VDE0805/EN60950/IEC950 File No. R917062
TÜV Certificate No. R9172062
UL1950 File No. E135734
CSA C22.2 No. 950 Bulletin No. 1402C
http://www.artesyn.com
PAGE 2
1000-1200W AC/DC
|
MEDIUM TO HIGH POWER AC/DC POWER SUPPLIES
1000 and 1200 Watt
AC/DC high wattage power supplies with PFC
PIN NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Mechanical notes
OUTPUT PIN CONNECTIONS
J1
J2
+ Sense (V1) (4)
+ Sense (V2)
Current Monitor (V1) (5)
- Sense (V2)
Inhibit (5)
Current Share (V2)
- Sense (V1) (4)
+ Sense (V4)
No Connection
- Sense (V4)
No Connection
Current Share (V4)
Current Share (5)
Remote Adj. (V2) (6)
(6)
Remote Adj. (V1)
Remote Adj. (V3) (6)
(5)
AC Good
Remote Adj. (V4) (6)
Chassis Ground
Current Share (V3)
Logic Ground
- Sense (V3)
Margin (7)
+ Sense (V3)
No Connection
N/A
DC OK (5,8)
N/A
A AC connector is 3 position terminal block (#8 screws included), mating to
#8 ring tongue terminal.
B DC output is 5/16-18 studs mating to 5/16 terminal lugs.
C J1 signal connector is Molex 39-30-1140 or equivalent. Mating connector
is Molex 39-01-2140 or equivalent.
D J2 signal connector is Molex 39-01-1120 or equivalent. Mating connector
is 39-01-2120 or equivalent.
E Signal connector contacts are Molex 39-00-0039 or equivalent.
F Auxiliary DC output(s) are 6 position terminal block (#8 screws included)
mating to #8 ring tongue terminal.
G TB1 and J2 are not installed on single output models.
Notes
1
2
3
4
5
6
7
8
1000W or 1200W max. power. 500/600W max. power (V2 thru V4). All
outputs isolated.
Specifications refer to all outputs except as noted (V1).
Signal referenced to V1 output neg. sense trim.
Use 20AWG or larger twisted pair.
Reference to Logic Ground (Pin J1-11).
See Figure 4.
See Figure 3.
See Figure 5.
12.13 Max.
(308.10)
11.00
(279.40)
0.75
(19.05)
Auxiliary Outputs
(# 8 Screws)
6.750
(171.450)
AC Input
(# 8 Screws)
ACH
+
v
2
-
5.00
(127.00)
+
v
3
-
T
B
1
4.00
(101.60)
ACN
V2
V3
TB1 and J2 are Not
Installed on Single
Output Models
V4
+
v
4
-
0.90 (22.86)
V1
+
_
J
2
V1
1.30 (33.02)
J
1
0.50 (12.70)
8-32 X 0.29 (7.37) Deep (Max.)
(4) Both Sides
Main Output
5/16 - 18 Studs
50 IN-LB Torque Max.
1.13
(28.70)
2.80
(71.12)
J1
5.75
(146.05)
0.90 (22.86)
Pin 1
AIRFLOW
8.00
(203.2)
J2
8-32 x 0.29 (7.37) Deep (Max.)
(4) Top and Bottom
Pin 1
ALL DIMENSIONS IN INCHES (mm)
PAGE 3
MEDIUM TO HIGH POWER AC/DC POWER SUPPLIES
|
1000-1200W AC/DC
1000 and 1200 Watt
AC/DC high wattage power supplies with PFC
FIG. 1
FIG. 2 (Ref. FIG 5)
J1-P9 AC Good, J1-P14 DC OK
15V
FIG. 5
AC Power Fail Signal/DC OK Timing
AC Input Voltage
10K
Low = Power/Output fail
High = Power/Output OK
External Pull-up Required
Sink Current 20mA
(On Voltage 0.7V)
J1-P3
85Vrms
0V
>10ms
AC Good Flag
Close to Enable
>5ms
DC Outputs
FIG. 3
FIG. 4
Open = Nominal Voltage
5V Tie to +5V for High Margin
Tie to Logic Ground (J1-11)
For Low Margin.
Output Voltage
DC Good Flag
(J1-P8)
> 10K
(J1-P12) Margin
Sense
STANDARD CONTROL SIGNALS
Remote enable
DC OK
(See Figures 2 and 5)
AC power fail signal
(See Figure 5)
Margin Hi/Lo (V1)
(See Figure 3)
Remote Adjust
(See Figure 4)
Current Monitor
See Figure 1
Signal remains "Hi" as long as
output is ±5.0% of nominal.
Signal "Hi" when AC >85VAC and
"Lo" when <75VAC.
Allows ±5.0% change in output
for system margin checking.
The outputs may be remotely
adjusted linearly ±10%.
Analog signal indicates load current in
single or parallel operation. 5±0.5VDC
represents FL, resistive load 103kΩ.
DS_N1000/N1200_19980401.PDF
http://www.artesyn.com
PAGE 4