POWER-ONE MPB150

MPB150 Dual-Output AC-DC Series Data Sheet
Features
• RoHS compliant for all six substances
• High power density in an industry-standard 3" x 5"
footprint
• Power Factor Correction (PFC) meets EN61000-3-2
• Main output remote sense
• Power Good signals
• CE marked to Low Voltage Directive
• Input transient & ESD compliance to
EN61000-4-2/-3/-4/-5
Description
The MPB150 Series incorporates patented high efficiency circuitry, high power density and active Power Factor
Correction (PFC) to meet the requirements of networking and data communications systems, as well as commercial
and industrial configurations.
MPB150’s deliver a regulated main output plus a second 12V output for fans or other system functions. The MPB150
is rated for convection as well as forced-air cooling. Full output power is available with as few as 15 Cubic Feet per
Minute (CFM) forced-air cooling.
The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.
Model Selection
MODEL
MPB150-2012G
(NOTE 2, 3, 4)
MPB150-2024G
(NOTE 2, 3, 4)
MPB150-2048G
(NOTE 2, 3, 4)
NOTES: 1)
2)
3)
4)
OUTPUT
VOLTAGE
(VOLTS)
MAXIMUM OUTPUT
CURRENT (AMPS),
130 LFM
TOTAL
REGULATION
%
RIPPLE & NOISE
% pk-pk
(NOTE 1)
REGULATION RANGE
+12V
12V
+24V
12V
+48V
12V
12.5A
0.5A
6.0A
0.5A
3.1A
0.5A
±3%
±5%
±3%
±5%
±3%
±5%
1%
1%
1%
1%
1%
1%
11.64V to 12.36V
11.40V to 12.60V
23.28V to 24.72V
11.40V to 12.60V
46.56V to 49.44V
11.40V to 12.60V
Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
Maximum forced-air output power is 150 watts with 15 CFM airflow.
Maximum convection output power is 70 watts.
V2 is isolated from V1 and can be used as a negative or positive output.
APR 28, 2006 revised to JAN 24, 2007
Page 1 of 4
www.power-one.com
MPB150 Dual-Output AC-DC Series Data Sheet
Input Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
Input Voltage- AC
Input Frequency
Brownout Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Continuous input range.
AC Input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Over full AC input voltage range at full rated load.
90 VAC at full rated load.
Non-user serviceable internally located AC input line fuse, 250 VAC, 3.15A.
Internally limited by thermistor,
110VAC:
one cycle, 25° C.
220VAC:
Active PFC meets requirements of EN61000-3-2.
Switching frequency of main transformer.
90
47
90
17
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Efficiency
Minimum Loads
Full Load, 230VAC. Varies with distribution of loads among outputs.
V1 load for full regulation on V2. All models operate
at no load without any damage and meet all specs on V1 above 0 amps.
Full load, 20 MHz bandwidth.
At 15 CFM forced-air cooling. See Application Note for details.
Convection: Consult Factory.
Output voltage overshoot/undershoot at turn-on.
Varies by output. Total regulation includes: line changes from 85-132 VAC
or 170-264 VAC, changes in load starting at 20% load and changing to 100% load.
Maximum deviation due to a 25% load change with unit at 75% load.
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
75
5
80
85
%
Watts
Power Factor Circuitry
Operating Frequency
NOM
MAX
UNITS
264
63
VAC
Hz
VAC
ms
ARMS
2.2
23
46
45
APK
kHz
Output Specifications
Ripple and Noise
Output Power (Note 1)
Overshoot /Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
See Model Selection Chart
150
10
Watts
%
See Model Selection Chart
3
0.2
0.2
1.5
20
%
Sec
ms
Interface Signals and Internal Protection
PARAMETER
CONDITIONS/DESCRIPTION
Overvoltage Protection
V1 output.
Overload Protection
Remote Sense (Note 1)
Power Good Signal
Power Supply OK Signal
Thermal Shutdown
Current Share
Isolation Diode
MIN
MPB150-2012
13.5
MPB150-2024
26.9
MPB150-2048
57.6
Fully protected against output short circuit or overload. Automatic recovery upon
removal of overload condition.
Total (+sense and -sense) voltage compensation for cable losses.
AC/DC indicator - This signal indicates the status of the AC input or DC outputs.
When there is sufficient AC voltage and the outputs are operating normally, an
open collector signal is provided.
Turn-On delay time from application of AC:
50
Warning time before outputs go out of regulation:
5
Warning time before outputs deviate ±10% from the nominal value:
15
Sink Current
Pull-up Voltage
Provided on dual-output models. Open collector signal intended to drive an LED.
Closed collector occurs when the Power Good Signal is in its open collector state.
Sink Current
Pull-up Voltage
NOM
MAX
UNITS
16.5
31.1
62.4
VDC
500
mV
500
ms
20
30
mA
V
20
30
mA
V
Protected against overtemperature conditions.
Unit recovers when overtemperature condition is removed.
Up to 4 units can be connected in parallel.
There are some limits for parallel operation. See Applications Note.
N+1 redundancy is provided. V2 needs an external isolation diode for N+1 operation.
Internal isolation diode is provided on V1.
NOTES: 1) Negative (-) sense must be connected to output common or load common for proper power supply operation.
APR 28, 2006 revised to JAN 24, 2007
Page 2 of 4
www.power-one.com
MPB150 Dual-Output AC-DC Series Data Sheet
Safety, Regulatory, and EMI Specifications
PARAMETER
CONDITIONS/DESCRIPTION
Agency Approvals
UL60950-1.
CSA 22.2 No. 60950-1.
(Approvals Pending)
EN60950 (TÜV).
IEC60950-1.
AC to chassis.
1500
Input to output.
3000
EN55022 Conducted.
Class A
6
Per EN61000-4-2, Level 4
8
Per EN61000-3-3.
Per EN61000-4-3.
3
Per EN61000-4-4.
1
Per EN61000-4-5, Level 3, 2 kV (Line-to-Gnd) minimum, 1 kV (Line-to-Line) minimum.
Per EN61000-4-6. 0.15 to 80 MHz (1 kHz sinewave)
3
Per EN61000-4-8.
1
Per EN61000-4-11.
Input to output.
10
Per EN60950 (264 VAC)
1.0
Dielectric Withstand Voltage
Electromagnetic Interference
ESD Susceptibility
Flicker
Radiated Susceptibility
EFT/Burst
Input Transient Protection
RF Immunity
Magnetic Fields
Voltage Dips
Insulation Resistance
Leakage Current
MIN
NOM
MAX
UNITS
VAC
VDC
dB
kV
V/m
kV
V/m
A/m
M⍀
mA
Environmental Specifications
PARAMETER
CONDITIONS/DESCRIPTION
Altitude
Operating
Non-Operating
Derate linearly from 50 to 70°C to 50% power at 70°C.
At 100% load:
MPB150 models will operate at -20°C, but will not meet all specifications.
Operating Temperature
Storage Temperature
Forced-Air Cooling
Temperature Coefficient
Relative Humidity
Shock
Vibration
MIN
Forced-air cooling of 15 CFM is required for full output power. Air velocity
is measured with power supply mounted on 0.375" (9.5mm) standoffs.
Airflow direction is from the input section to the output section.
See Application Note for details.
Included in total regulation of outputs.
Non-Condensing.
Operating: 11 ±3ms, 3 axes, Half Sine.
Non-operating: 11 ±3ms, 3 axes, Half Sine.
Operating:
Random vibration, 5-500 Hz, 10 minutes each axis.
Non-Operating: Random vibration, 5-500 Hz, 10 minutes each axis.
APR 28, 2006 revised to JAN 24, 2007
Page 3 of 4
NOM
MAX
UNITS
0
10K
50K
50
-40
85
°C
5
85
15
%RH
40
2.4
6.0
ASL Feet
°C
Gpk
GRMS
GRMS
www.power-one.com
MPB150 Dual-Output AC-DC Series Data Sheet
Mechanical Drawing (-2012G, -2024G, & -2048G Models)
WEIGHT:
0.63 lb. (0.3 kg)
J 1 - A C INPUT CONNECTOR
Pin 1
Pin 2
Pin 3
NEUTRAL
N O PIN
LINE
5.00"
(127.0)
Ø 0.16" (4 PL)
(4.06)
4.55"
(115.57)
J 2 - V 1 DC OUTPUT
CONNECTOR
TOP VIEW
PIN #1
2.56"
(65.02)
J3- SIGNAL
CONNECTOR
PIN #1
PIN #1
J4- V2 DC OUTPUT
CONNECTOR
SAFETY GROUND
CONNECTION POINT
FASTENER
CLEARANCE
AREA (4 PL)
SCREWS SHOWN
FOR REFERENCE
ONLY
0.06"
(1.5)
CIRCUIT
1
2
3
4
5
6
-2024G
+24V
+24V
+24V
RTN
RTN
RTN
-2048G
+48V
+48V
+48V
RTN
RTN
RTN
Pin
Pin
Pin
Pin
Pin
Pin
1
2
3
4
5
6
RTN
- SENSE
+ SENSE
CURRENT SHARE
POWER GOOD
POWER SUPPLY OK
J4 Pin 1
Pin 2
+12V
+12V RTN
1.00"
(25.4)
1.25"
(31.75)
PRINTED
Pin
Pin
Pin
Pin
Pin
Pin
MPB150
-2012G
+12V
+12V
+12V
RTN
RTN
RTN
J3 -
PIN #1
3.00" 2.78"
(76.2) (70.6)
J2 -
BOARD
END VIEW
SIDE VIEW
0.19"
(4.8)
Mating Connectors
NOTE: Part numbers are MOLEX; equivalents are acceptable.
MPB150
-2012G
-2024G
-2048G
09-50-8031
J1
Housing
Pins
08-52-0113
J2
Housing
09-50-8061
Pins
08-52-0113
J3
Housing
22-01-3067
Pins
08-50-0114
J4
Housing
22-01-3027
Pins
08-50-0114
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
APR 28, 2006 revised to JAN 24, 2007
Page 4 of 4
www.power-one.com