FXC7000 AC-DC Series Data Sheet r Front-End Distributed Powe Features • Three-phase AC input • Suitable for 3U or 5U height mounting • Single-wire current share or Droop current share • Remote voltage adjust and current monitoring • Overtemperature, overload, and overvoltage protection • LED supply status indicators • Current-share control for up to 30 units • Front panel selectable-input-range FXC7000 Front and Rear Views Description The FXC7000 Series of standalone or rack-mounted power systems provides true AC front-end capability to automatic test equipment, telecom, data communications, and other distributed power designs. The FXC systems may be paralleled up to 210 kW of output power and are intended for chassis-mounted installations with bolted connections. These power supplies provide excellent protection against input voltage transients. The FXC has its fan located at the front of the supply, and voltage adjust, indicator lights, output bussbars, and connectors on the rear. Airflow is from the front through the rear. Alarm, monitoring, and control signals are floating from the main output and can be referenced to the positive or negative output or sense line of the power supply. The output is floating with respect to the chassis and may be used as a positive or negative polarity supply. The FXC7000 Series meets international safety requirements and is CE Marked to the Low Voltage Directive. This series operates on three-phase European voltages as well as (up to) 480VAC, delta or wye. Chassis-Mountable Model MODEL FXC7000-48-S OUTPUT VOLTAGE INPUT VOLTAGE RANGE 3-PHASE (VAC) ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT LINE REGULATION LOAD REGULATION (NOTE 1) INITIAL SETTING ACCURACY 48V 180 to 264 or 342 to 528 45.6V to 50.4V 145A 0.15% 0.2% 47.90V to 48.10V (NOTE 2) NOTES: 1) With Remote Sense connected. 2). User-selectable input voltage ranges Input Specifications PARAMETER DESCRIPTION/CONDITIONS MIN Input Voltage - AC 3-phase delta low input range, nominal. 3-phase delta high input range, nominal. Continuous deviation from the above nominals. Per phase at full rated load. FXC7000 at 180 VAC: Internally limited. Vin = 264VAC (one cycle). 25° C: Vin = 528VAC (one cycle). 25° C: AC input. After last AC line peak at full power. 208 VAC: 400 VAC: Switching frequency, fixed. 200 380 -10 Input Current Inrush Surge Current Input Frequency Hold-up Time Operating Frequency Power Factor AUG 18, 2006 revised to JAN 09, 2007 MAX 240 480 +10 30 30 15 60 50 17 13 UNITS VAC % ARMS APK Hz ms 100 0.90 Page 1 of 4 NOM kHz W/VA www.power-one.com FXC7000 AC-DC Series Data Sheet Output Specifications PARAMETER DESCRIPTION/CONDITIONS MIN NOM MAX UNITS Output Voltage Adjustment Range Output Power Output Current Efficiency Regulation An additional 1.0 Volt is provided to the output terminals to provide for load lead losses. Continuous duty rating. Continuous duty rating. Full rated load (208Vac). Load, Maximum deviation with 0 to 100% load change: With Remote Sense connected: With Remote Sense not connected: Utilizing Droop Current Share: Line, Under all specified operating conditions. Measured at mating connector w/ 0.01µF + 10µF Tant. 20 MHz BW: 100 MHz BW: Output voltage overshoot/undershoot at turn-on. Minimum loading required to maintain regulation. Maximum recovery time, to within 1% of initial set Time: point due to a 25% load change, 1A/µS. Deviation: Time required for initial output voltage stabilization after power-up. Time required for output voltage to rise from 10% to 90%. 45.6 48 50.4 V 7000 145 Watts A % Ripple & Noise Overshoot / Undershoot Minimum Loads Transient Response Turn-On Delay Turn-on Rise Time 88 91 0.2 0.75 2.0 0.2 1 2 0 % % p-p 800 3.2 3 100 % A µs % s ms 0 Interface Signals and Internal Protection PARAMETER (NOTE 1,2) DESCRIPTION/CONDITIONS MIN NOM MAX UNITS AC Power Fail Warning Auxiliary Power Warning provided prior to Vout dropping 5% after loss of AC input. Output voltage - diode isolated. Inclusive of line, load, and initial tolerances. Output current. Monitor output current over a compliance range of 0~10V. Normal output: Total error current: Static sharing deviation as a percent of full-load rating Active: for loads >10%. Passive: Maximum signal resistance in high input voltage range selection. Warning provided prior to protective reduction in current limit. Voltage required to enable supply (0.5 mA sink). (NOTE 3) Voltage required to enable supply (6 mA sink). (NOTE 3) Straight line current limit (above approx. 5V Vout). Signal level on overload. Occurs on overload when Vout is below approx. 5V. Iavg: May operate in burst-mode. Deviation from adjusted Vout that is considered as a fault. Output voltage swing available through Margin pin (analog). Time between fault warning and shutdown. Latching shutdown. Latch style overvoltage protection. Resistance to logic ground upon insertion of supply. Maximum load lead loss compensation (round trip). 4 11.6 12.0 12.4 500 ms V mA Current Monitor Current Share Input Range Select Status Loss of Phase Warning Output Inhibit Output Interlock Output Overload Protection Output Overload Warning Output Short Circuit Protection Output Voltage Fault Signal Output Voltage Margin Overtemperature/ Fan Failure Warning Overvoltage Protection Power Supply Present Signal Remote Sense 0.10 0.5 0.5 5 10 0.10 500 1.0 1.0 156 149 2.2 25 90 mA/A mA % ⍀ ms V V A V A ±3 ±4.8 100 ±4 ±5.0 ±5 ±5.2 % % ms 55.2 57.6 1000 60.0 V ⍀ V 1.0 NOTES: 1) All logic outputs listed below feature a standard active pull-down output with 0.4V max at 40 mA sink capability, and a 100k pull-up to 5V. 2) In addition to those listed below, signals and front-panel LEDs are provided to indicate: overtemperature/fan fault, AC phase imbalance, output good, interlock open, and supply inhibited. The FXP also provides 4 LED’s indicating output loading. 3) Both signals must be pulled to logic ground for the unit to operate. Enables are 100% redundant internally for applications where redundant inhibit is desirable. Contact factory for additional design details. AUG 18, 2006 revised to JAN 09, 2007 Page 2 of 4 www.power-one.com FXC7000 AC-DC Series Data Sheet Safety, Regulatory, and EMI Specifications PARAMETER CONDITIONS/DESCRIPTION Agency Approvals UL60950/CSA60950-00 (cULus), IEC60950 3rd Edition, EN60950 (TÜV), CE marked for the Low Voltage Directive FCC CFR title 47 Part 15 Sub-Part B - Conducted. EN55022 / CISPR 22 Conducted. Per EN61000-4-2, level 4. Per EN61000-4-3, level 3. Per EN61000-4-4, level 4. Per EN61000-4-5 Line-to-Line: Line-to-Ground: Per SEMI F47-0200 FXC/FXP6000 Per UL60950 and FXC7000 at 240 VAC, 60 Hz: EN60950: FXC7000 at 400 VAC, 50 Hz: FXC7000 at 480 VAC, 60 Hz: Electromagnetic Interference ESD Susceptibility Radiated Susceptibility EFT/Burst Input Transient Protection Voltage Sag Immunity Leakage Current MIN NOM MAX A A 8 10 ±4 4 3 UNITS Class kV V/M kV kV Pending 5 7 10 mA Environmental Specifications PARAMETER CONDITIONS/DESCRIPTION Altitude Operating. Non-Operating. MIN Operating Temperature Storage Temperature Temperature Coefficient Relative Humidity Shock Vibration Airflow At 100% load: At 50% load: NOM 0 -40 0°C to 70°C (after 15-minute warm-up). Non-Condensing. Operating: half-sine 10 ms, 3 axis Non-operating: half-sine 10 ms, 3 axis Operating: swept sine 5-2000-5 Hz, 5-32 Hz, 0.02îDA, 32-2000 Hz Non-operating: random 10-2000 Hz Airflow provided through the supply from front to rear. MAX UNITS 10k 40k 40 70 85 .02 95 +20 +40 1 6.15 ASL Ft. 155 4.4 555 2.8 Weight 27 12 °C °C %/°C %RH GPK GPK Grms cfm m3/min lfm m/s lb kg NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. AUG 18, 2006 revised to JAN 09, 2007 Page 3 of 4 www.power-one.com FXC7000 AC-DC Series Data Sheet FXC7000 OVERALL SIZE: 15.17" x 8.00" x 5.00" (385.3mm x 203.2mm x 127.0mm) MAINTAIN 25 SQ IN MIN FREE AREA (FRONT AND REAR) FOR AIR COOLING 7.705" (195.7mm) 3.510" (89.2mm) 0.955" (24.3mm) 1.10" (27.9mm) 15.17" (385.3mm) 10.260" (260.6mm) 0.85" (21.6mm) A A A A 6.850" (174mm) 5.42" (137.7mm) 4.24" (107.6mm) INSULATOR BLOCK <--AIRFLOW SIDE VIEW A A A A 1.100" (27.9mm) 0.53" (13.4mm) 2 PL 3.60" 4.480" (91.5mm) (113.8mm) 0.480" (12.2mm) A A A FOR MOUNTING, USE M4 X 0.7 SCREWS, 8PL (MARKED A) ON SIDE OR BOTTOM WITH MAXIMUM PENETRATION 3.8mm. 2 PL 1.22" (31.1mm) 0.70"2 PL (17.9mm) 1.10" 2 PL DIA 0.25" (6.4mm) RECOMMENDED MOUNTING TORQUE 10.5 INCH LBS. (0.64N/M) BOTTOM VIEW A 0.955" A (24.3mm) 2 PL A A A 0.20" (5.1mm) 3.510" (89.2mm) (28mm) 7.705" (195.7mm) 13.455" (341.8mm) FRONT VIEW REAR VIEW 9 18 26 5.00" (127mm) 1 10 19 AC INPUT PE L1 L2 0.06 (1.7) 2 PL DC OUTPUT L3 POS 13mm CENTER-TO-CENTER 10mm 8.00" (203.2mm) NEG VOLTAGE ADJUST POT 5 LED INDICATORS M4 THREAD 26-PIN CONNECTOR AMP PN: 749030-1 PIN 1 AC SIGNAL DC Vadj T MATING CONNECTOR: CONNECTOR SHELL... AMP PN 748365-1 CONTACTS... AMP PN 748333-2 INPUT VOLTAGE RANGE SELECT MODULE ROTATE 180 DEGREES FOR 240 VAC 480VAC INPUT VOLTAGE DISPLAY CUTOUT AUG 18, 2006 revised to JAN 09, 2007 Page 4 of 4 www.power-one.com