1200 WATTS POWER FACTOR CORRECTED SINGLE OUTPUT, HOT SWAP SPH-1200 Featuring: • Diode isolated output for hot swap • “Zero wire” slope program current sharing for redundancy • High power density: 5 W/cu. in. • Industry standard DIN connector • Universal AC input • 0.99 typical power factor • DC power good and AC power fail signals • True remote inhibit • Monotonic turn-on and turn-off STANDARD SPH SERIES MODEL OUTPUT RATING PWR OUT SPH-1200-24 SPH-1200-28 SPH-1200-48 24V @ 50A 28V @ 42A 48V @ 25A 1200 1200 1200 The SPH-1200 series provides lowcost, highly reliable, N+1 redundant hot swap power for critical applications. These 1200-watt single-output power supplies include an integral fan and are available with a front panel and handle for front access in sub-system racks or without handles for embedded applications. Power factor correction, OR-ing diodes, and current sharing make the SPH series an ideal choice for communications and data processing systems utilizing distributed power or redundant power architecture. SEE TRACSK (R EM) T SYS Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com 1200 WATTS 13.44”x 5”x 4.03” SPH-1200 SPH-1200 7.3 lbs - 3.3 kgs Dimensions: Inches Millimeters SPECIFICATIONS: ALL MODELS OPTIONS INPUT AC Input: 105-264 Vac continuous range, 47 to 63 Hz. Internally fused for 20 A. Power Factor: 0.99 typical at full load. Meets EN61000-3-2. Inrush: Cold start ac current is less than 75 A at 115 Vac and 150 A at 230 Vac for 8 ms typical. Limited by thermistor. Holdup Time: 16 ms minimum after removal of power at full load. Efficiency: 80% minimum AC Power Fail: Provides TTL “0” 5 ms before output voltage goes out of regulation band upon loss of AC power. Brownout Protection: Holds regulation to 85 Vac for 30 seconds maximum. Option “R”, Rack Mount Panel: Special panel is required for rack mounting. OUTPUT Adjustability: User adjustable ±5% minimum. Line Regulation: ±0.2% Load Regulation: ±2% (Slope Program) from 0 to 100% load change. Turn On Delay: 1 second typical Output Rise Time: (from 10% to 90%) 20 ms typical. Ripple & Noise: Less than 1% p-p, measured at 20 MHz bandwidth. Temperature Coefficient: 0.02% per degree C. Stability: 0.1% over 8 hours after 30 minutes warm-up. Transient Response: Output voltage returns to within 1% in less than 500 µs for a 50% load change. Peak transient does not exceed 3%. Overload Protection: Electronic current limit, 120% maximum. Overvoltage Protection: Protects load against power supply induced overvoltage. Trip point is factory set so that output voltage cannot exceed 136% of nominal. Requires AC input to be cycled to reset. Remote Inhibit: Contact closure or a TTL level “0” turns off DC output. DC Power Good: Provides a TTL “0” open collector when output is above 90% of nominal. Maximum pull-up voltage 30 Vdc; maximum sink current, 10 mA. Redundancy: Built-in OR-ing diode, slope program current sharing, and DIN blade connector provide “hot swap” and “N+1” capabilities. Current sharing remains within 10% of the unit’s full output rating given 0.2% initial accuracy in the output voltage setting. Status Indicators: Green LED on the front panel indicates normal operation (ACPF high and DCPG low) Consult factory for other available options. AC INPUT (105-264 VAC Continuous Range) LOCATION Z32 D30 Z28 115 VAC Line Neutral Safety Ground 230 VAC Line 1 Line 2 Safety Ground LOCATION Z12 D14 Z16 D18 Z4 D6 Z8 D10 NOTES (+) to Polarity (-) to Polarity CONNECTOR See Below DC OUTPUT FUNCTION Output Voltage CONNECTOR Eurocard Connector Male DIN 41 612 Level 1- Type H STATUS AND CONTROL FUNCTION DC Power Good AC Power Fail Inhibit LOCATION Z20 D22 Z24 NOTES Reference to to Common CONNECTOR See above ENVIRONMENTAL Thermal Protection: Shuts down power supply if overheated. Automatic recovery. Temperature Range: 0° to 50°C at full ratings. Safety Agencies: Approved to UL1950; CSA 22.2 #950; IEC 950 and TÜV EN60950, Class 1 SELV, CE 73/23/EEC//93/68/EEC (low voltage directive). Conducted RFI: Meets FCC Part 15, Subpart J, Class A; EN55022 Class B; and CISPR 22 Class B. Cooling: Self-cooled by internal ball-bearing fan. Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com