LEM HTFS400-P

Current Transducer HTFS 200..800-P IPN = 200 - 400 - 800 A
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
All Data are given with a R L = 10 kΩ
Electrical data
Primary nominal
r.m.s. current
IPN (A)IP (A)
VREF
RL
kΩ
ROUT
CL
VC
IC
Type
± 300
± 600
± 1200
HTFS 200-P
HTFS 400-P
HTFS 800-P
Features
200
400
800
VOUT
Primary current
measuring range
• Hall effect measuring principle
• Galvanic isolation between primary
Analog output voltage @ IP
VREF ±(1.25·IP/IPN) V
IP = 0
VREF ± 0.025
V
Internal Reference1) - Output voltage
1/2VC ± 0.025
V
VREF Output impedance typ. 200
Ω
VREF Load impedance
≥ 200
kΩ
Output load resistance
≥2
Output impedance
Max. output capacitive load
Supply voltage (± 5 %)
Current consumption @ VC = 5 V
< 10
<1
5
22
Ω
µF
V
mA
and secondary circuit
• Low power consumption
• Single power supply +5V
• Ratiometric offset
• TA = -40..+105 °C
• Fixation by M3 nuts and screws
Advantages
• Small size and space saving
• Only one design for wide current
ratings range
• High immunity to external
Accuracy - Dynamic performance data
X
ε
L
TCVOUT
TCVREF
TCVOUT / VREF
TCε G
VOM
t ra
tr
di/dt
f
Accuracy 2) @ IPN , TA = 25°C
Linearity error 0 .. 1.5 x IPN
Thermal drift of VOUT @ IP = 0
Thermal drift of VREF
Thermal drift of VOUT / VREF @ IP = 0
Thermal drift of the gain
Residual voltage @ IP = 0,
after an overload of 3 x IPN DC
Reaction time @ 10 % of IPN
Response time @ 90 % of IPN
di/dt accurately followed
Output noise (DC ..10 kHz)
(DC .. 1 MHz)
Frequency bandwidth (- 3 dB) 3)
≤±
≤±
≤±
≤±
≤±
1
0.5
0.3
0.01
0.2
% of IPN
% of IPN
mV/K
%/K
mV/K
≤ ± 0.05% of reading/K
< ± 0.5
<3
<7
> 100
< 15
< 40
DC .. 20
% of IPN
µs
µs
A/µs
mVpp
mVpp
kHz
interference.
• VREF. IN/OUT
Applications
• Forklift drives
• AC variable speed drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
applications.
General data
TA
TS
m
Ambient operating temperature
Ambient storage temperature
UL94 classification
Mass
Standards
- 40 .. + 105
°C
- 40 .. + 105
°C
V0
60
g
EN 50178: 1997
Application Domain
• Industrial
Notes : 1) It is possible to overdrive VREF with an external reference voltage
between 2 - 2.8 V providing its ability to sink or source approx. 2.5 mA.
2)
Excluding offset.
3)
Small signal only to avoid excessive heatings of the magnetic core.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM
051110/3
Page 1/3
www.lem.com
Current Transducer HTFS 200..800-P
Isolation characteristics
Vb
Vb
Vd
Ve
Vw
dCp
dCl
CTI
Nominal Voltage
with IEC 61010-1 standards and following conditions
- Single insulation
- Over voltage category III
- Pollution degree 2
- Heterogeneous field
Nominal Voltage
with EN 50178 standards and following conditions
- Reinforced insulation
- Over voltage category III
- Pollution degree 2
- Heterogeneous field
R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn
R.m.s. voltage for partial discharge extinction @ 10pC
Impulse withstand voltage 1.2/50µs
Creepage distance
Clearance distance
Comparative tracking index (Group IIIa)
150
V r.m.s.
150
V r.m.s.
2.5
>1
4
>4
>4
> 220
kV
kV
kV
mm
mm
V
If insulated cable is used for the primary circuit, the
voltage category could be improved with the following table :
Cable insulation (primary)
Category
HAR 03
300V CAT III
HAR 05
400V CAT III
HAR 07
500V CAT III
Safety
This transducer must be used in electric/electronic equipment
with respect to applicable standards and safety requirements
in accordance with the following manufacturer's operating
instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can
carry hazardous voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious
damage.
This transducer is a built-in device, whose conducting parts
must be inaccessible after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
051110/3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM
Page 2/3
www.lem.com
Dimensions HTFS 200..800-P (in mm. 1 mm = 0.0394 inch)
Ip
40
16.5
4-d3.5
1
33
20
d6
d5
0.5
33
d22
26
16
5
3-P=2.54
4
1
4.5
3.5+/-1
4-0.25x0.5
7
Terminal Pin
Required Connection Circuit
1...+5V
2...0V
3...Output
4...Vref (IN/OUT)
Vref (IN/OUT)
HTFS
4
VRef
3 Output
2
Output
47nF
0V
1 +5V
4.7nF
47nF
0V
+5V
Operation Principle
+Vc
Vout
Vref.(IN/OUT)
0V
Ip
Mechanical characteristics
•
•
•
•
General tolerance
Fixation by
Recommended fastening torque
Fastening & connection of secondary
Recommended PCB hole
Remarks
± 0.2 mm
4 x M3 (not supplied)
< 2.5 Nm
4 pins 0.5 x 0.25
Ø 0.7 mm
• VOUT is positive when IP flows in the direction of the
arrow.
• Temperature of the primary conductor should not
exceed 120°C.
051110/3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM
Page 3/3
www.lem.com