LEM EN50178

Current Transducer LTS 6-NP
IPN
=
6 At
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
Electrical data
I PN
IP
Î PDC
VOUT
NS
RL
R IM
TCR IM
VC
IC
Primary nominal r.m.s. current
Primary current, measuring range
Overload capability
Analog output voltage @ I P
IP = 0
Number of secondary turns (± 0.1 %)
Load resistance
Internal measuring resistance (± 0.5 %)
Thermal drift of R IM
Supply voltage (± 5 %)
Current consumption @ VC = 5 V
6
At
0 .. ± 19.2
At
250
At
2.5 ± (0.625·IP/IPN) V
2.5 1)
V
2000
≥2
kΩ
208.33
Ω
< 50
ppm/K
5
V
28+ IS2) + (VOUT/RL)mA
Typ
ε
Accuracy @ IPN , T A = 25°C
Accuracy with R IM @ IPN , T A = 25°C
Linearity error
L
TCVOUT Thermal drift of VOUT @ IP = 0
TCεG
VOM
tr a
tr
di/dt
f
- 10°C .. + 85°C
- 40°C .. - 10°C
Thermal drift of the gain
- 40°C .. + 85°C
Residual voltage @ IP = 0,after an overload of 3 x IPN
5 x IPN
10 x IPN
± 0.2
± 0.7
< 0.1
Typ
80
Reaction time @ 10 % of IPN
Response time @ 90 % of IPN
di/dt accurately followed
Frequency bandwidth (0 .. - 0.5 dB)
(- 0.5 .. 1 dB)
%
%
%
Max
200 ppm/K
250 ppm/K
50 3) ppm/K
± 0.5
mV
± 2.0
mV
± 2.0
mV
< 100
< 400
> 15
DC .. 100
DC .. 200
ns
ns
A/µs
kHz
kHz
General data
TA
TS
m
Notes :
Ambient operating temperature
Ambient storage temperature
Insulating material group
Mass
Standards 4)
1)
2)
3)
4)
• Closed loop (compensated) multi•
•
•
•
•
range current transducer using the
Hall effect
Unipolar voltage supply
Compact design for PCB mounting
Insulated plastic case recognized
according to UL 94-V0
Incorporated measuring resistance
Extended measuring range.
Advantages
Accuracy - Dynamic performance data
X
Features
- 40 .. + 85
- 40 .. + 100
III a
10
°C
°C
g
EN 50178 : 1997
IEC 60950-1 : 2001
Absolute value @ T A = 25°C, 2.475 < VOUT < 2.525
Please see the operation principle on the other side
Only due to TCR IM
Specification according to IEC 61000-4-3 are not guaranteed between
95 and 110 MHz (value higher by 5% than the specification).
•
•
•
•
•
•
•
Excellent accuracy
Very good linearity
Very low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
• Current overload capability.
Applications
• AC variable speed drives and servo
•
•
•
•
•
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding
applications.
Application domain
• Industrial.
Copyright protected.
050713/14
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM Components
Tope Co., Ltd.
Tel: (02) 8228-0658
Page 1/3
www.lem.com
Fax: (02) 8228-0659
http://www.sensor.com.tw
e-mail: [email protected]
Current Transducer LTS 6-NP
Isolation characteristics
Vd
VW
R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn
Impulse withstand voltage 1.2/50 µs
3
>8
Ve
Min
R.m.s. voltage for partial discharge extinction @ 10pC > 1.5
dCp
dCl
CTI
Creepage distance 5)
Clearance distance 6)
Comparative Tracking Index (Group III a )
Min
15.5
6.35
175
kV
kV
kV
mm
mm
Application examples
According to EN 50178 and IEC 61010-1 standards and following conditions :
• Over voltage category OV 3
• Pollution degree PD2
• Non-uniform field
EN 50178
IEC 61010-1
Rated isolation voltage
Nominal voltage
Single isolation
600 V
600 V
Reinforced isolation
300 V
300 V
dCp, dCI, VW
Notes :
5)
6)
On housing
On PCB with soldering pattern UTEC93-703.
Safety
This transducer must be used in electric/electronic equipment with respect to
applicable standards and safety requirements in accordance with the following
manufacturer's operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a built-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
050713/14
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM Components
Page 2/3
www.lem.com
Dimensions LTS 6-NP
(in mm. 1 mm = 0.0394 inch)
Operation principle
Bottom view
Front view
Back view
Right view
Number
of primary
turns
Primary nominal
r.m.s. current
IPN [ A ]
Nominal
output voltage
VOUT [ V ]
Primary
resistance
R P [ mΩ ]
Primary
insertion inductance
L P [ µH ]
1
±6
2.5 ± 0.625
0.18
0.013
Recommended
connections
IN
2
±3
2.5 ± 0.625
0.81
±2
2.5 ± 0.625
1.62
4
OUT
1
6
2
5
3
4
OUT
1
6
2
5
3
4
OUT
1
2
3
0.12
IN
Mechanical characteristics
5
0.05
IN
3
6
Output Voltage - Primary Current
• General tolerance
• Fastening & connection of primary
VOUT [ V ]
± 0.2 mm
6 pins 0.8 x 0.8 mm
Recommended PCB hole
1.3 mm
• Fastening & connection of secondary 3 pins 0.5 x 0.35 mm
Recommended PCB hole
0.8 mm
• Additional primary through-hole
∅ 3.2 mm
5
4.5
3.125
2.5
1.875
Remarks
0.5
• VOUT is positive when IP flows from terminals 1, 2, 3 to
terminals 6, 5, 4.
• Temperature of the primary jumper should not exceed 100°C.
- IPmax
- IPN 0
IPN
IPmax
IP [ At ]
050713/14
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.