FCA50F

Ordering information
AC-DC Power Supplies Enclosed type
FCA50F
FCA
FCA
1
50
2
F
3
-24
4
-O
5
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional *6
N1 :with DIN rail attachment
R
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
FCA50F-24
50(Peak 160)
24V 2.1(Peak 6.7)A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
ACIN 240V
ACIN 480V
FREQUENCY[Hz]
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*3
*4
*5
*6
ACIN 240V
ACIN 480V
ACIN 240V
INRUSH CURRENT[A]
ACIN 480V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
*1
CURRENT[A]
LINE REGULATION[mV]
0 - 2.1A
LOAD REGULATION[mV]
0 - 6.7A
0 to +50C *2
RIPPLE[mVp-p]
-10 - 0C *2
0 to +50C *2
RIPPLE NOISE[mVp-p]
-10 - 0C *2
TEMPERATURE REGULATION[mV] -10 to +50C
*5
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
*3
VIBRATION
*3
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
*4
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
FCA50F-24
AC187 - 528 1f or DC265 - 746
0.55typ
0.30typ
50/60 (47 - 63)
82typ
78typ
25typ (At cold start) (At Room Temperature)
50typ (At cold start) (At Room Temperature)
0.75max (60Hz, According to IEC60950)
24
2.1 (Peak 6.7)
96max
150max
480max
240max
320max
680max
720max
600max
100max
800max (ACIN 240V, Io=100%)
10typ (ACIN 240V, Io=100%)
21.6 - 26.4
Works over 105% of peak current and recovers automatically
Works at 115 - 140% of rating
LED (Green)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL, EN60950-1, EN50178
Complies with FCC-A, CISPR11-A, EN55011-A
50X125X124mm (WXHXD) / 640g max
Convection
Peak current for 150ms in a 30seconds period is acceptable.
In case of rated input/output(ACIN240-480v/2.1A), either the 20MHz oscilloscope or the ripple noise meter(equivalent to Keisokugiken:RM101) is used.
Option with DIN rail attachment(N1) is only for direction X(refer to sec4.2 in manual).
Depth of power supply is 132mm with DIN rail attachment.
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Please contact us about safety approvals for the model with option.
FCA-2
FCA50F
External view
FCA
13max
50
30
(11.5)
LED
Voltage Adjust
DIN Rail Attachment
FCA50F-24-N1 only
FG
125
(72)
(102)
AC(N)
Spacer
FCA50F-24-N1 only
(7)
7
(34)
AC(L)
AC(N)
Terminal
Block
(M4)
(110)
AC(L)
(35.5)
-V
FG
(116)
+V
13
+
-
10
FCA50F-24
(15.5)
16
(8)
124
(24.5)
(22)
(12)
119
3-M3 Mounting Hole
50
44.5
25.4
12.7 25.4±0.5
º3.8
71.1±0.5
Terminal Block Cover
¶Weight : 640g or less
¶Tolerance : ±1
¶Mounting torque : 0.6N•m
(6.3kgf•cm)max
¶Dimensions in mm.
45.9
18max
Performance data
¡STATIC CHARACTERISTICS
¡RISE TIME & FALL TIME
24
Io=100%
14
Ripple
12
50
10
8
25
150
160
170
180
190
200
210
220
230
240
Io=100%
Io=50%
10
5
0
AC Input
ACIN 480V
250
¡OVERCURRENT CHARACTERISTICS
26
50ms/DIV
¡INRUSH CURRENT
Input Voltage AC480V
24
V
15
DC Output
V 60Hz (AC 100V)
INPUT VOLTAGE
OUTPUT VOLTAGE
V
75
OUTPUT VOLTAGE
16
20
22
20A/DIV
OUTPUT VOLTAGE
18
100
RIPPLE mVp-p
V
20
25
Output Voltage
22
60Hz
Frequency
100%
Load
Input voltage AC480V
20
18
16
14
12
2
4
6
8
OUTPUT CURRENT A
10
12
50ms/DIV
FCA-3
Ordering information
AC-DC Power Supplies Enclosed type
FCA75F
FCA
FCA
1
75
2
F
3
-24
4
-O
5
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional *6
N1 :with DIN rail attachment
R
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
FCA75F-24
75(Peak 240)
24V 3.1(Peak 10)A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
ACIN 240V
ACIN 480V
FREQUENCY[Hz]
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*3
*4
*5
*6
ACIN 240V
ACIN 480V
ACIN 240V
INRUSH CURRENT[A]
ACIN 480V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
*1
CURRENT[A]
LINE REGULATION[mV]
0 - 3.1A
LOAD REGULATION[mV]
0 - 10A
0 to +50C *2
RIPPLE[mVp-p]
-10 - 0C *2
0 to +50C *2
RIPPLE NOISE[mVp-p]
-10 - 0C *2
TEMPERATURE REGULATION[mV] -10 to +50C
*5
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
*3
VIBRATION
*3
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
*4
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
FCA75F-24
AC187 - 528 1f or DC265 - 746
0.80typ
0.45typ
50/60 (47 - 63)
82typ
78typ
25typ (At cold start) (At Room Temperature)
50typ (At cold start) (At Room Temperature)
0.75max (60Hz, According to IEC60950)
24
3.1 (Peak 10)
96max
150max
480max
240max
320max
680max
720max
600max
100max
800max (ACIN 240V, Io=100%)
10typ (ACIN 240V, Io=100%)
21.6 - 26.4
Works over 105% of peak current and recovers automatically
Works at 115 - 140% of rating
LED (Green)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL, EN60950-1, EN50178
Complies with FCC-A, CISPR11-A, EN55011-A
65X125X124mm (WXHXD) / 750g max
Convection
Peak current for 150ms in a 30seconds period is acceptable.
In case of rated input/output(ACIN240-480v/3.1A), either the 20MHz oscilloscope or the ripple noise meter(equivalent to Keisokugiken:RM101) is used.
Option with DIN rail attachment(N1) is only for direction X(refer to sec4.2 in manual).
Depth of power supply is 132mm with DIN rail attachment.
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Please contact us about safety approvals for the model with option.
FCA-4
FCA75F
External view
FCA
13max
65
45
(11.5)
LED
DIN Rail
Attachment
FCA75F-24-N1
only
Voltage Adjust
AC(N)
(35.5)
(116)
(72)
AC(L)
AC(N)
Terminal
Block
(M4)
Spacer
FCA75F-24-N1
only
(7)
7
(34)
AC(L)
125
FG
13
-V
FG
(102)
+V
(110)
+
-
10
FCA75F-24
(15.5)
(8)
124
(24.5)
(37)
18
(12)
119
38.1±0.5
3-M3 Mounting Hole
¶Weight : 750g or less
¶Tolerance : ±1
¶Mounting torque : 0.6N•m
(6.3kgf•cm)max
¶Dimensions in mm.
12.7
31.75
64.5
59.5
º3.8
Terminal Block Cover
71.1±0.5
45.9
18max
Performance data
¡STATIC CHARACTERISTICS
¡RISE TIME & FALL TIME
24
14
Io=100%
12
Ripple
50
10
8
25
150
160
170
180
190
200
210
220
230
240
Io=100%
Io=50%
10
5
0
DC Output
AC Input
ACIN 480V
250
¡OVERCURRENT CHARACTERISTICS
26
50ms/DIV
¡INRUSH CURRENT
Input Voltage AC480V
24
V
15
V 60Hz (AC 200V)
INPUT VOLTAGE
OUTPUT VOLTAGE
V
75
OUTPUT VOLTAGE
16
20
22
20A/DIV
OUTPUT VOLTAGE
18
100
RIPPLE mVp-p
V
20
25
Output Voltage
22
60Hz
Frequency
100%
Load
Input voltage AC480V
20
18
16
14
12
2
4
6
8
OUTPUT CURRENT A
10
12
50ms/DIV
FCA-5
Ordering information
AC-DC Power Supplies Enclosed type
FCA200F
FCA
FCA 200
1
2
F
3
-24
4
-O
5
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional *6
N1:with DIN rail attachment
R
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
FCA200F-24
200 (Peak 1,008)
24V 8.4 (Peak 42)A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
ACIN 240V
ACIN 480V
FREQUENCY[Hz]
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*3
*4
*5
*6
ACIN 240V
ACIN 480V
ACIN 240V
POWER FACTOR
ACIN 480V
ACIN 240V
INRUSH CURRENT[A]
ACIN 480V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
*1
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV] 0 - 8.4A
0 to +50C *2
RIPPLE[mVp-p]
-10 - 0C *2
0 to +50C *2
RIPPLE NOISE[mVp-p]
-10 - 0C *2
TEMPERATURE REGULATION[mV] -10 to +50C
*5
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
*3
VIBRATION
*3
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
*4
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
FCA200F-24
AC187 - 528 1f or DC265 - 530
1.10typ
0.55typ
50/60 (47 - 63)
81typ
81typ
0.98typ
0.93typ
25typ (At cold start) (At Room Temperature)
50typ (At cold start) (At Room Temperature)
1.5max (60Hz, According to IEC60950)
24
8.4 (Peak 42)
96max
150max
240max
320max
680max
720max
600max
100max
800max (ACIN 240V, Io=100%)
100typ (ACIN 240V, Io=100%)
21.6 - 26.4
Works over 105% of peak current and recovers automatically
Works at 115 - 140% of rating
LED (Green)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
-10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL, EN60950-1
Complies with FCC-A, CISPR11-A, EN55011-A
150X125X125mm (WXHXD) / 1,700g max
Convection
Peak current for 50ms in a 30seconds period is acceptable.
In case of rated input/output(ACIN240-480v/8.4A), either the 20MHz oscilloscope or the ripple noise meter(equivalent to Keisokugiken:RM101) is used.
Option with DIN rail attachment(N1) is only for direction X(refer to sec4.2 in manual).
Depth of power supply is 133mm with DIN rail attachment.
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Please contact us about safety approvals for the model with option.
FCA-6
FCA200F
External view
3-Spacer
FCA200F-O-N1 only
FCA
(35.5)
(72)
(7)
(7)
(50)
3-DIN Rail Attachment
FCA200F-O-N1 only
(50)
20max
125
(8)
(23)
(38)
2-Terminal Block Cover
(98)
(92.5)
Name Plate
13
(20)
LED for confirming
of output
150
¶ Mounting Hole
10
Voltage Adjust
101.6 t0.5
125
FCA200F
7-M4
V+ADJ
FG
(56)
(73.5)
(43)
+V
AC(L)
+V
AC(N)
(12)
¶ Tolerance ±1
¶ Material Electric galvanizing steel board
¶ Weight:1700g or less.
¶ Mounting torque:0.6N m(6.3kgf cm)max
¶ Dimensions in mm
-V
(20)
(58)
(97)
(20)
(11)
127t0.5
(29)
(12.4)
-V
4-M4
Mounting Hole
Performance data
¡INPUT HARMONIC CURRENT (FCA200F-24 )
¡RISE TIME & FALL TIME (FCA200F-24 )
10
1
20
OUTPUT VOLTAGE V
A
HARMONIC CURRENT
25
Harmonic current standard class A
(at odd number)
Load factor
100%
Input voltage AC 240V
0.1
0.01
0.001
0
10
20
30
15
Io=100%
10
5
DC Output
0
AC Input
ACIN 480V
40
100ms/DIV
HARMONIC ORDER
¡OVERCURRENT CHARACTERISTICS (FCA200F-24 )
¡INRUSH CURRENT (FCA200F-24 )
20A/DIV
30
Input Voltage AC480V
OUTPUT VOLTAGE V
25
60Hz
Frequency
100%
Load
Input voltage AC480V
20
15
10
5
20
40
OUTPUT CURRENT A
60
80
50ms/DIV
FCA-7