Ordering information Rugged PCB type LDA15F LDA 1 15 2 F 3 -5 4 -O 5 1Series name 2Output wattage 3Universal input 4Output voltage 5Optional C :with Coating G :Low leakage current S :with Chassis SN :with Chassis & cover Y :with Potentiometer R MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT LDA15F-3 9 3V 3.0A LDA15F-5 15 5V 3.0A LDA15F-12 15.6 12V 1.3A LDA15F-15 15 15V 1.0A LDA15F-24 16.8 24V 0.7A SPECIFICATIONS MODEL VOLTAGE[V] LDA CURRENT[A] INPUT FREQUENCY[Hz] EFFICIENCY[%] ACIN 100V ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C RIPPLE[mVp-p] -10 - 0C 0 to +50C RIPPLE NOISE[mVp-p] -10 - 0C TEMPERATURE REGULATION[mV] *1 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE CASE SIZE/WEIGHT COOLING METHOD INRUSH CURRENT[A] OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS ACIN 100V ACIN 200V LDA15F-5 LDA15F-12 LDA15F-15 LDA15F-24 =LDA15F-3 AC85 - 264 1f or DC110 - 370 0.37typ (Io=100%) 0.23typ (Io=100%) 47 - 440 or DC 70typ 74typ 76typ 76typ 78typ 15typ (Io=100%) (At cold start) 30typ (Io=100%) (At cold start) 0.75max (60Hz, According to UL, CSA, VDE and DEN-AN) 3 5 12 15 24 3 3 1.3 1 0.7 20max 20max 48max 60max 96max 40max 40max 100max 120max 150max 80max 80max 120max 120max 120max 140max 140max 160max 160max 160max 120max 120max 150max 150max 150max 160max 160max 180max 180max 180max 50max 50max 120max 150max 240max 20max 20max 48max 60max 96max 200max (ACIN 100V, Io=100%) 10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) 100typ (ACIN 200V, Io=100%) 2.85 - 3.6 Fixed ("Y"which can be adjusted the output is available as option :5 - 24V t10%) 4.9 - 5.3 11.5 - 12.5 14.4 - 15.6 23.0 - 25.0 xx Works over 105% of rating and recovers automatically 4.00V min Works over 115% of rating, by zener diode clamping Not provided Not provided Not provided AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) -10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL1950, EN60950, VDE0160, CSA C22.2 No.234 Complies with DEN-AN and IEC60950 Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B 50X21X125mm (WXHXD) /95g max (without chassis and cover) Convection *1 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. * Avoid prolonged use under over-load. * Series/Parallel operation with other model is not possible. * Derating is required when operated with chassis and cover. =marked models are pending for safety approvals. Consult with us for delivery. D-28