MAP130 AC-DC Series Data Sheet Features • RoHS lead-solder-exempt compliant • • • Automatic 115/230 input voltage selection All outputs fully regulated Remote sense, overvoltage protection, and overtemperature protection Power Fail signal included Greater than 100,000 Hour MTBF U-Channel chassis: 8.50" x 4.50" x 2.00" (215.9mm x 114.3mm x 50.8mm) Optional cover Metric and SAE mounting inserts • • • • • Description Power-One’s MAP130 Series of single and multiple output power supplies provide fully-regulated outputs with high peak current capabilities in a compact 4.50" x 8.50" x 2.00" U-channel chassis. Other standard features include autoselect AC input, EMI level B filtering, power fail, thermal shutdown (with warning), remote sense, and metric and SAE mounting inserts. This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50°C. All products are approved to the latest international regulatory standards and display the CE Mark. Single Output Model Selection MODEL MAP130-1005 MAP130-1012 MAP130-1024 OUTPUT VOLTAGE ADJUSTMENT RANGE CONTINUOUS CURRENT PEAK CURRENT (NOTE 3) LINE REGULATION LOAD REGULATION 5V 12V/15V 24V/28V 4.75V to 5.50V 11.4V to 15.75V 22.5V to 30.0V 26A 12A/10A (Note 2) 6.2A/5.4A (Note 2) 30A 13.8A/11A 6.8A/5.9A 0.2% 0.2% 0.2% 1% 1% 1% TYPICAL RIPPLE & INITIAL SETTING NOISE %p-p (NOTE 1) ACCURACY 1% 1% 1% 5.1V to 5.2V 12.0V to 12.2V 23.9V to 24.1V NOTES: 1) Typical peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. 2) MAP130-1012 output currents are expressed as 12V/15V operation. MAP130-1024 output currents are expressed as 24V/28V operation. 3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum. Multiple Output Model Selection – 130W Continuous Output Power MODEL MAP130-4000 MAP130-4001 MAP130-4002 MAP130-4003 OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT PEAK CURRENT (NOTE 1) LINE REGULATION LOAD REGULATION +5V +12V -5V -12V +5V +24V -12V +12V +5V +12V -12V +12V +5V +15V -5V -15V 4.75V to 5.50V 11.5V to 12.5V Fixed Fixed 4.75V to 5.50V 23.0V to 25.0V Fixed Fixed 4.75V to 5.50V 11.5V to 12.5V Fixed Fixed 4.75V to 5.50V 14.0V to 16.0V Fixed Fixed 20A 5A 1A 1A 20A 3.5A 1A 1A 20A 5A 1A 1A 20A 4A 1A 1A 30A 10A 1A 1A 30A 5A 1A 1A 30A 10A 1A 1A 30A 8A 1A 1A 0.2% 0.5% 0.5% 0.5% 0.2% 0.5% 0.5% 0.5% 0.2% 0.5% 0.5% 0.5% 1% 1% 2% 2% 1% 2% 2% 2% 1% 2% 2% 2% 1% 2% 2% 2% 1% 2% 2% 2% JUN 14, 2006 revised to AUG 10, 2006 Page 1 of 4 TYPICAL RIPPLE & INITIAL SETTING NOISE %p-p (NOTE 2) ACCURACY 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 5.1V to 5.2V 11.75V to 12.0V -4.8V to -5.2V -11.6V to -12.4V 5.1V to 5.2V 23.9V to 24.1V -11.6V to -12.4V -11.6V to -12.4V 5.1V to 5.2V 11.9V to 12.1V -11.6V to -12.4V 11.6V to 12.4V 5.1V to 5.2V 15.0V to 15.1V -4.8V to -5.2V -14.7V to -15.3V www.power-one.com MAP130 AC-DC Series Data Sheet Multiple Output Model Selection (Cont.) – 130W Continuous Output Power MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT PEAK CURRENT (NOTE 1) LINE REGULATION LOAD REGULATION +5V +24V -15V +15V +5V +12V -5V -12V +5V +12V -12V -5V 4.75V to 5.50V 23.0V to 25.0V Fixed Fixed 4.75V to 5.50V 11.5V to 12.8V Fixed Fixed 4.75V to 5.50V 11.5V to 12.8V Fixed Fixed 20A 3.5A 1A 1A 20A 5A 1A 3A 20A 5A 1A 3A 30A 5A 1A 1A 30A 10A 1A 3A 30A 10A 1A 3A 0.2% 0.5% 0.5% 0.5% 0.2% 0.5% 0.5% 0.5% 0.2% 0.5% 0.5% 0.5% 1% 2% 2% 2% 1% 2% 2% 2% 1% 2% 2% 2% MAP130-4004 MAP130-4010 MAP130-4020 TYPICAL RIPPLE & INITIAL SETTING NOISE %p-p (NOTE 2) ACCURACY 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 5.15V to 5.2V 23.9V to 24.1V -14.5V to -15.5V 14.5V to 15.5V 5.1V to 5.25V 11.75V to 12.0V -4.8V to -5.2V -11.6V to -12.4V 5.1V to 5.25V 11.75V to 12.0V -11.6V to -12.4V -4.8V to -5.2V NOTES: 1) Peak loads up to 165 Watts, (total of all outputs), for 60 seconds or less are acceptable, (10% duty cycle max.). 2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. Input Specifications PARAMETER CONDITIONS/DESCRIPTION Input Voltage- AC Auto-ranging. Input Frequency Brown out Protection Hold-up Time Input Current Input Protection Inrush Surge Current Operating Frequency AC Input. Lowest AC input voltage that regulation is maintained with full rated loads. Nominal AC input voltage (115 VAC). 130W load: 90 VAC, 130W load. Non-user serviceable internally located AC input line fuse. Internally limited by thermistor. Vin = 264 VAC (one cycle). 25° C. Switching frequency of main transformer (variable). Range: Low Range High Range MIN NOM MAX 90 175 47 90 40 115 230 132 264 63 3.3 16 UNITS VAC Hz VAC mS ARMS 38 120 APK kHz MAX UNITS Output Specifications PARAMETER CONDITIONS/DESCRIPTION MIN Efficiency Minimum Loads Full Load, 115VAC. Varies with distribution of loads among outputs. MAP130-1012. MAP130-1024. MAP130-1005 and all multiple output models, main channel only. Full load, 20MHz bandwidth. Continuous output power, all multiple output models. Peak output power (60s maximum, 10% duty cycle), all multiple output models. Output voltage overshoot/undershoot at turn-on / turn-off Varies by output, Total regulation includes: line changes from 90-132 VAC or 175-264, changes in load starting at 20% load and changing to 100% load. Recovery time to within 1% of initial set point due to a 50-100% load change, 4% max. deviation. (Main output only on multi-output units) Time required for initial output voltage stabilization. Time required for output voltage to rise from 10% to 90%. 71 80 1.25 0.63 3.00 See Model Selection Chart 130 165 1 Ripple and Noise Output Power Overshoot /Undershoot Regulation Transient Response Turn-on Delay Turn-on Rise Time MAY 13, 2005 revised to JUN 14, 2006 Page 2 of 4 NOM % Amps Watts % See Model Selection Chart 500 µS 2 20 Sec mS www.power-one.com MAP130 AC-DC Series Data Sheet Interface Signals and Internal Protection PARAMETER CONDITIONS/DESCRIPTION Overvoltage Protection Provided on single output units and only the main output of multiple output units. Overcurrent Protection Remote Sense Power Fail Warning (Note 1) Overtemperature Warning (Note 2) MIN NOM MAP130-1012 17.0 MAP130-1024 32.0 MAP130-4004 6.2 All other models. 5.5 All models have inherent short circuit protection. Units will automatically restart at the removal of the fault. Total voltage compensation for main output cable losses. Logic LO (denotes power fail detected). Logic HI with internal pull-up to output. 10 Power Fail trip point, maximum load, decreasing line. 86 Time before regulation dropout, at full load, due to loss of input power. 5 Warning prior to system shutdown due to excessive internal temperatures. 20 Shifts Power Fail signal to a logic LO state. MAX UNITS 22.0 37.0 7.4 6.8 VDC 250 0.7 94 mV V k⍀ VAC mS mS NOTES: 1) Power Fail not available on MAP130-1012 and MAP130-1024. 2) MAP130-1012 and MAP130-1024 have overtemperature protection, but do not have the warning feature. Safety, Regulatory, and EMI Specifications PARAMETER CONDITIONS/DESCRIPTION Agency Approvals ESD Susceptibility Radiated Susceptibility EFT/Burst Input Transient Protection UL1950. CSA 22.2 No. 234/950. EN60950 (TÜV). Input to Output, 1 second. FCC CFR title 47 Part 15 Sub-Part B - Conducted EN55022 / CISPR 22 Conducted EN55022 / CISPR 22 Radiated (Note 1) Per EN61000-4-2, level 4 Per EN61000-4-3, level 3 Per EN61000-4-4, level 3 (Note 2) Per EN61000-4-5 class 3 Insulation Resistance Leakage Current Input to output Per EN60950 (264 VAC) Dielectric Withstand Voltage Electromagnetic Interference, MIN NOM MAX UNITS Approved 2600 B B B 8 10 ±2 Line to Line 1 Line to Ground 2 7 VDC Class kV V/M kV kV 700 M⍀ µA MAX UNITS NOTES: 1) MAP130-1005 meets Class A, radiated. 2) MAP130-1005, MAP130-4003, and MAP130-4010, meet level 2, ±1kV. Environmental Specifications PARAMETER CONDITIONS/DESCRIPTION Altitude Operating Non-Operating MIN Operating Temperature Derate linearly above 50°C by 2.5% per °C Storage Temperature Temperature Coefficient Relative Humidity Shock Vibration At 100% load: At 50% load: NOM 0 -40 0°C to 70°C (after 15 minute warm-up period) Non-Condensing Operating, peak acceleration Random vibration, 10Hz to 2kHz, 3 axis ±0.02 5 10K 40K 50 70 85 ±0.05 95 20 6 Feet °C °C °C %/°C %RH GPK GRMS Options DESCRIPTION NOTES Cover Add ‘C’ suffix to model number or order part number 412-59586-G separately. For convection cooled applications with covers, derate output power as follows: Derate all multiple output models and MAP130-1005 to 120 watts. Derate MAP130-1012 and MAP130-1024 to 140 watts. JUN 14, 2006 revised to AUG 10, 2006 DIMENSIONS Page 3 of 4 8.50" x 4.50" x 2.40" (215.9mm x 114.3mm x 61.0mm) www.power-one.com MAP130 AC-DC Series Data Sheet OVERALL SIZE: 8.50" x 4.50" x 2.00" (215.9mm x 114.3mm x 50.8mm) WEIGHT: 2.5 lb (1.13 kg) INPUT & OUTPUT CONNECTIONS: 6-32 SCREW WIRE CLAMPS ON 0.312" (7.9mm) CENTERS, 0.045" (1.1mm) SQUARE PINS ON 0.156" (3.96mm) CENTERS; MATES WITH MOLEX SERIES 2139, 6442, & 41695 POWER FAIL CONNECTIONS, J2: 0.035" (0.89mm) SQUARE PINS ON 0.100" (2.54mm) CENTERS; MATES WITH MOLEX SERIES 2695 & 6471 CHASSIS: 0.090" (2.286mm) ALUMINUM ALLOY WITH CLEAR FINISH NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. MAY 13, 2005 revised to JUN 14, 2006 Page 4 of 4 www.power-one.com