POWER-ONE MDU200

MPU200/MDU200 Series Data Sheet
Features
•
RoHS lead free solder and lead solder exempted products
are available
Power Factor Correction (PFC) meets EN61000-3-2
Same size, airflow, and construction as MPU150/MDU150
with over 33% more power
Single-wire current sense on quad model outputs V1 and V2
Remote sense on quad model outputs V1 and V2
Current share and N+1 redundancy (standard on all models)
Overtemperature, overload, and overvoltage protection
Available with SAE mountings
MDU200 models have 48VDC input
•
•
•
•
•
•
•
•
Description
The MPU200/MDU200 Series is based upon the proven architecture of the MPU150/MDU150 product line. The MPU products
incorporate Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints. In this series, 200W
of continuous output power is provided with single or multiple output units suited for distributed power or central power applications.
The series provides high current +3.3V and +5V on a single platform to support mixed-mode, high-speed digital circuitry.
Power-One's dual-converter architecture combines high reliability with exceptional regulation. All multiple-output models feature
remote sense on outputs V1 and V2 to provide independent compensation of output cable losses.
Other standard features include independent current sharing on V1 and V2 quad-model outputs, thermal shutdown, and remote
inhibit. Airflow of 300 linear feet per minute (LFM) is required to deliver the full power density of greater than 4.0 watts per cubic inch.
The MDU200 Series provides the same benefits as the MPU200 Series, with a nominal 48 volt DC input.
AC Input, Single-Output Model Selection
MODEL
MPU200-1012
MPU200-1024
MPU200-1048
200W/225W PK WITH 300 LFM FORCED-AIR COOLING (NOTE 1)
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT (NOTE 2)
12V
24V
48V
11.6V to 16V
22.8V to 29.2V
45V to 56V
17.0A
8.35A
4.2A
PEAK OUTPUT
LINE
CURRENT (NOTE 2) REGULATION
19.0A
9.4A
4.7A
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 3)
INITIAL SETTING
ACCURACY
1%
1%
1%
1%
1%
1%
11.97V to 12.03V
23.95V to 24.05V
47.9V to 48.1V
0.1%
0.1%
0.1%
AC Input, Multiple-Output Model Selection
200W WITH 300 LFM FORCED-AIR COOLING (NOTE 1)
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS
MODEL
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT (NOTE 2)
LINE
REGULATION
LOAD
REGULATION
+5V
5.0V to 5.5V
30A (Note 4)
0.4%
1%
+3.3V
3.15V
to
3.60V
15A
(Note
4)
0.6%
1.5%
MPU200-4530
12V
10.8V to 13.2V
8A (Note 5)
0.4%
10%
12V
10.8V to 13.2V
4A (Note 5)
0.4%
10%
NOTES: 1) This product is not rated for convection applications.
2) Output currents ratings are expressed with 300 LFM forced air.
3) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
4) Total current for V1 and V2 is not to exceed 35A.
5) Total power on V3 and V4 is not to exceed 100W.
RIPPLE & NOISE
%Pk-Pk (NOTE 3)
INITIAL SETTING
ACCURACY
1%
1.5%
1%
1%
4.98V to 5.02V
3.28V to 3.32V
11.94V to 12.06V
11.60V to 12.40V
Ordering Information:
OPTIONS
SUFFIXES TO ADD TO PART NUMBER
Metric Mounting
Add “M” as a suffix to the model number to order chassis with
M3 x 0.7 mounting inserts. Consult factory for availability.
Offered on single-output models. Add “D” to the part number suffix if an isolation diode is needed.
Consult factory for availability.
Isolation Diode
RoHS lead solder exemption
RoHS compliant for all 6 substances
JUL 14, 2006 revised to JUL 24, 2006
No RoHS suffix character required.
Add “G” as the last character of the part number.
Page 1 of 6
www.power-one.com
MPU200/MDU200 Series Data Sheet
DC Input, Single Output Model Selection
MODEL
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
12V
24V
11.6V to 16V
22.8V to 29.2V
17.0A
8.35A
48V
45V to 56V
4.2A
MDU200-1012G
MDU200-1024G
(NOTE 4)
MDU200-1048G
200W WITH 300 LFM FORCED-AIR COOLING (NOTE 1)
MAXIMUM OUTPUT
PEAK OUTPUT
CURRENT (NOTE 2) CURRENT (NOTE 2)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%Pk-Pk (NOTE 3)
INITIAL SETTING
ACCURACY
19.0A
9.4A
0.1%
0.1%
1%
1%
1%
1%
11.97V to 12.03V
23.95V to 24.05V
4.7A
0.1%
1%
1%
47.9V to 48.1V
Isolation Diode Option - Offered on single-output models. Add “D” at the end of the part number if an isolation diode is needed.
MPU200 Input Specifications
PARAMETER
Input Voltage - AC
Input Frequency
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Power Factor
Operating Frequency
CONDITIONS/DESCRIPTION
Continuous input range.
AC input.
After last AC line peak at 200 watts
85 VAC at full rated load.
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 230 VAC, one cycle, 25°C.
Per EN61000-3-2.
Switching frequency of main output transformer.
Switching frequency of secondary transformer.
Switching frequency of Power Factor Correction circuit.
MIN
85
47
15
NOM
MAX
264
63
4.0
35
0.95
100
65
120
90
UNITS
VAC
Hz
ms
ARMS
APK
W/VA
kHz
60
MDU200 Input Specifications
PARAMETER
Input Voltage - DC
Brown Out Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Operating Frequency
CONDITIONS/DESCRIPTION
Continuous input range.
Lowest DC input voltage that regulation is maintained with full rated loads.
At 200 watts, over DC input range.
36 VDC at full rated load.
Non-user serviceable internally located AC input line fuse.
Consult factory.
Switching frequency of main output transformer.
Switching frequency of secondary transformer.
MIN
36
34
15
NOM
MAX
75
8.35
100
70
UNITS
VDC
VDC
ms
ARMS
kHz
NOTES:1) This product is not rated for convection applications.
2) Output currents ratings are expressed with 300 LFM forced air.
3) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
4) Derating is required on output voltages above 27VDC. Consult factory.
JUL 14, 2006 revised to JUL 24, 2006
Page 2 of 6
www.power-one.com
MPU200/MDU200 Series Data Sheet
Output Specifications
PARAMETER
Efficiency
Minimum Load, V1
Minimum Load, V3
Ripple and Noise
Overshoot / Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
Full Rated Load, 110 VAC (MPU) or 48VDC (MDU).
Varies with distribution of loads among outputs.
65
75
Minimum load required to maintain regulation on,
V2 at maximum load.
Quad output model V1
3
Minimum load required on single output models.
Single output models V1
0
Minimum load required to maintain regulation on
Quad output model V3
0.3
V4 at maximum load.
Full load, 20 MHz bandwidth.
See Model Selection Charts
Output voltage overshoot/undershoot at turn-on.
5
Varies by output. Total regulation includes: line changes over the specified.
See Model Selection Charts
input range, changes in load starting at 20% load and changing to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100% load change,
500
5% max. deviation.
Time required for initial output voltage stabilization.
2
Time required for output voltage to rise from 10% to 90%.
MPU200
50
MDU200
80
UNITS
%
A
A
%
μs
s
ms
Interface Signals and Internal Protection
PARAMETER
Overvoltage Protection
CONDITIONS/DESCRIPTION
Latch style overvoltage protection.
4.2
6.4
19
20.5
38.0
62.7
Overload Protection
Overtemperature Protection
MPU200-4530 3.3V output
3.8
MPU200-4530 5V output
6.0
MPU200-4530 12V output
14
MDU200/MPU200-1012 V1 17.0
MDU200/MPU200-1024 V1 32.0
MDU200/MPU200-1048 V1 58.0
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
System shutdown due to excessive internal temperature, automatic reset.
TTL compatible signal available for V1. Internal pull-up resistor is 475⍀.
3.3V
Signal is high when output is above the specified limits. Signal shall
5V
remain low for 20 milliseconds following loss of Output Good.
MDU200/MPU200-1012 12V
MDU200/MPU200-1024 24V
MDU200/MPU200-1048 48V
TTL compatible logic signal. Time before regulation dropout due to loss of input
power. May be used as independent PSOK signal in redundant applications.
Accuracy of shared current with up to 6 parallel units. Single wire current share
on V1 and V2 with return via -Sense return.
Available on V1 and V2. Total voltage compensation for cable losses with
respect to the main output.
Output voltage is inhibited by application of an external high (5V) signal.
3.16
4.75
3.25
4.95
10.5
21.5
43.0
11.9
23.5
47.0
Output Good Signal
(Transision from
Low to High)
Input Power Fail Warning
Current Share
Remote Sense
Inhibit
JUL 14, 2006 revised to JUL 24, 2006
MIN
Page 3 of 6
NOM
MAX
5
UNITS
V
V
ms
10
%
500
mV
www.power-one.com
MPU200/MDU200 Series Data Sheet
Safety, Regulatory, and EMI Specifications
PARAMETER
Agency Approvals
Dielectric Withstand Voltage
CONDITIONS/DESCRIPTION
UL60950,CSA 22.2 NO. 60950, and EN60950-1 (TÜV).
Input to output per EN60950.
Electromagnetic Interference
FCC CFR title 47 Part 15 Sub-Part B - Conducted.
EN55022 / CISPR 22 Conducted.
Per EN61000-4-2, level 4.
Per EN61000-4-3, level 3.
Per EN61000-4-4, level 3.
Per EN61000-4-5, class 3.
ESD Susceptibility
Radiated Susceptibility
EFT/Burst
Input Transient Protection
Insulation Resistance
Leakage Current
Input to output.
Per EN60950.
MIN
NOM
MAX
UNITS
(Approved)
MPU200:
MPU200:
MDU200:
MDU200:
MPU200
MDU200
Line to Line
Line to Ground
Line to Line
Line to Ground
2600
1414
B
B
8
10
±2
1
2
0.5
0.5
VDC
Class
kV
V/M
kV
kV
10
MPU200 Quad Output Model
MPU200 Single Output Models
MDU200 at 72 VDC
(Not required by EN60950)
MV
2.2
1.7
N/A
mA
MAX
10k
40k
50
70
85
±0.05
95
20
6
UNITS
ASL Ft.
ASL Ft.
°C
°C
°C
%/°C
%RH
GPK
GRMS
Environmental Specifications
PARAMETER
Altitude
CONDITIONS/DESCRIPTION
Operating.
Non-Operating.
MIN
Operating Temperature
Derate linearly above 50°C by 2.5% per °C.
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
0°C to 70°C (after 15 minute warm-up).
Non-Condensing.
Peak acceleration.
Random vibration, 10Hz to 2kHz, 3 axis.
At 100% load
At 50% load
NOM
0
0
-55
±0.02
5
Options
DESCRIPTION
Metric Mounting
Isolation Diode
NOTES
Add “M” as a suffix to the model number to order chassis with
M3 x 0.7 mounting inserts. Consult factory for availability.
Offered on single-output models. Add “D” to the part number suffix if an isolation diode is needed. Consult factory for
availability.
JUL 14, 2006 revised to JUL 24, 2006
Page 4 of 6
www.power-one.com
MPU200/MDU200 Series Data Sheet
Overall Size: 8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm) Weight: 2.0 lb (0.89 kg)
SINGLE OUTPUT
OUTPUTS:
8-32 SCREW
CONNECTIONS
(4PL)
+V1
RTN
INTERFACE CONNECTIONS (J300)
MDU200
DC
INPUT
J1
+ 5
+ 4
S
V1,V.
ADJ.
3
2
1
MPU200 J1
AC
L 1
INPUT
PIN
10. +S, V1
9. -S, V1
8. CURRENT SHARE, V1
7. NO CONNECTION
6. NO CONNECTION
5. NO CONNECTION
4. OUTPUT GOOD, V1
3. POWER FAIL WARNING
2. INHIBIT
1. SIGNAL GROUND
MOLEX SERIES 5268-NA, P/N: 22-05-7105, PINS
ON 2.50mm CENTERS.
N 3
5
MATES WITH MOLEX:
HOUSING SERIES 5264-N, P/N: 50-37-5103 (&)
PINS SERIES 5263, P/N: 80-70-1040 (LOOSE)
3
TBD
NOTE:
MAX. LEAD PROTRUSION IS 0.0625" (1.588mm)
ON THE FOUR BOTTOM MOUNTING HOLES.
MAX. LEAD PROTRUSION OF 0.25" (6.25mm)
IS ACCEPTABLE ON THE FOUR SIDE MOUNTING
HOLES.
CONNECTOR
J1
J300
MOLEX
SERIES
41695
41695
2139
09-50-8051
09-50-8051
09-50-3051
5264-N
50-37-5103
HOUSING
JUL 14, 2006 revised to JUL 24, 2006
PIN
PINS
PINS
WIRE
SERIES (LOOSE)
(CHAIN)
GAUGE
6838 08-50-0189 08-50-0187 18-20AWG
2478 08-50-0106 08-50-0105 18-20AWG
2478 08-50-0106 08-50-0105 18-20AWG
5263
CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY,
WITH CLEAR FINISH
08-70-1040 08-70-1039 22-28AWG
Page 5 of 6
www.power-one.com
MPU200/MDU200 Series Data Sheet
Overall Size: 8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm) Weight: 2.0 lb (0.89 kg)
3
TBD
NOTE:
MAX. LEAD PROTRUSION IS 0.0625" (1.588mm)
ON THE FOUR BOTTOM MOUNTING HOLES.
MAX. LEAD PROTRUSION OF 0.25" (6.25mm)
IS ACCEPTABLE ON THE FOUR SIDE MOUNTING
HOLES.
CONNECTOR
J1
(ALL MODELS)
J2
(TRIPLE OUTPUT)
J3
(TRIPLE OUTPUT)
J3
(QUAD OUTPUT)
J300
MOLEX
SERIES
41695
41695
2139
5051-N
5051-N
41695
41695
2139
41695
41695
2139
5264-N
HOUSING
09-50-8051
09-50-8051
09-50-3051
22-01-1022
22-01-1022
09-50-8021
09-50-8021
09-50-3021
09-50-8061
09-50-8061
09-50-3061
50-37-5103
PIN
SERIES
6838
2478
2478
2759
2759
6838
2478
2478
6838
2478
2478
5263
PINS
(LOOSE)
08-50-0189
08-50-0106
08-50-0106
08-50-0114
08-65-0805
08-50-0189
08-50-0106
08-50-0106
08-50-0189
08-50-0106
08-50-0106
08-70-1040
PINS
(CHAIN)
08-50-0187
08-50-0105
08-50-0105
08-50-0113
08-65-0804
08-50-0187
08-50-0105
08-50-0105
08-50-0187
08-50-0105
08-50-0105
08-70-1039
WIRE
GAUGE
18-20AWG
18-20AWG
18-20AWG
22-30AWG
22-30AWG
18-20AWG
18-20AWG
18-20AWG
18-20AWG
18-20AWG
18-20AWG
22-28AWG
CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY,
WITH CLEAR FINISH
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
JUL 14, 2006 revised to JUL 24, 2006
Page 6 of 6
www.power-one.com