LEM HTY75-P

Current Transducer HTY 50..100-P
IPN = 50 .. 100 A
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Electrical data
Primary nominal
current rms
IPN (A)
Primary current
measuring range
IPM (A)
50
75
100
± 150
± 225
± 300
VC
IC
Vd
R IS
VOUT
RL
Type
RoHS since
date code
HTY 50-P
HTY 75-P
HTY 100-P
Supply voltage (± 5 %)
Current consumption
Rms voltage for AC isolation test, 50 Hz, 1 min
Isolation resistance @ 500 VDC
Output voltage (Analog) @ ± IPN, RL = 10 kΩ, TA = 25°C
Load resistance
• Hall effect measuring principle
• Galvanic isolation between primary
46115
46013
46067
± 15
< ± 20
2.5
> 500
±4
> 10
and secondary circuit
V
mA
kV
MΩ
V
kΩ
Accuracy-Dynamic performance data
X
ε
L
VOE
VOH
TCVOE
TCVOUT
tr
BW
Accuracy @ IPN, TA = 25°C (excluding offset)
Linearity error (0 .. ± IPN)
Electrical offset voltage @ TA = 25°C
Hysteresis offset voltage @ IP = 0,
after an excursion of 1 x IPN
Temperature coefficient of VOE
< ± 1 % of IPN
< ± 1 % of IPN
< ± 30
mV
< ± 15
mV
typ. ± 2.0
mV/K
max. ± 3.0
mV/K
Temperature coefficient of VOUT (% of reading)
< ± 0.1
%/K
Response time to 90% of IPN step
<7
µs
Frequency bandwidth (- 3 dB)1)
DC .. 50
kHz
Ambient operating temperature
Ambient storage temperature
Mass
• Isolation voltage 2500 V
• Low power consumption
• Extended measuring range(3 x IPN)
Advantages
• Easy installation
• Small size and space saving
• Only one design for wide current
ratings range
• High immunity to external
interference.
Applications
• DC motor drives
• Switched Mode Power Supplies
(SMPS)
• AC variable speed drives
• Uninterruptible Power Supplies
(UPS)
General data
TA
TS
m
Features
- 10 .. + 75
- 15 .. + 85
30
°C
°C
g
• Battery supplied applications
• Inverters
Application domain
• Industrial
Note :
1)
Derating is needed to avoid excessive core heating at high frequency.
Page 1/2
070116/3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Dimensions HTY 50..100-P (in mm. 1 mm = 0.0394 inch)
24 +/-1
26 +/-1
Front View
Direction of Current Flow
6 +/-1
4 3 2 1
5 +/-1
0.5
14
d1
1
3-P2.5
Right View
4-0.5*0.25
8.5 +/-1
16 +/-1
20 +/-1
4-d1 (Mounting Post)
20 +/-1
Bottom View
Terminal Pin Identification
1 -Vcc
2 0V
3 +Vcc
4 Output
UNIT : mm
Safety
SCALE : 2/1
This transducer must be used in electric/electronic equipment
with respect to applicable standards and safety requirements
in accordance with the following manufacturer's operating
instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can
carry hazardous voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious
damage.
This transducer is a built-in device, whose conducting parts
must be inaccessible after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 2/2
070116/3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com