Features
Functional Description
• Dual channel video serializer
— 195- to 1500-Mbps serial data signaling rate
— Simultaneous operation at different signaling rates
• Second-generation HOTLink® technology
• Compliant to SMPTE 292M and SMPTE 259M video
standards
• Supports half-rate and full-rate clocking
• Internal phase-locked loops (PLLs) with no external
PLL components
• Redundant differential PECL-compatible serial outputs
per channel
— No external bias resistors required
— Signaling-rate controlled edge-rates
— Internal source termination
• Synchronous LVTTL parallel interface
• JTAG boundary scan
• Built-In Self-Test (BIST) for at-speed link testing
• Low-power 1.4W @ 3.3V typical
• Single 3.3V supply
• Thermally enhanced BGA
• 0.25µ BiCMOS technology
The CYV15G0203TB Independent Clock Dual HOTLink II™
Serializer is a point-to-point or point-to-multipoint communications building block enabling transfer of data over a variety of
high-speed serial links including SMPTE 292M and SMPTE
259M video applications. It supports signaling rates in the
range of 195 to 1500 Mbps per serial link. The two channels
are independent and can simultaneously operate at different
rates. Each channel accepts 10-bit parallel characters in an
Input Register and converts them to serial data. Figure 1 illustrates typical connections between independent video coprocessors and corresponding CYV15G0203TB Serializer
and CYV15G0204RB Reclocking Deserializer chips.
The CYV15G0203TB satisfies the SMPTE-259M and SMPTE292M compliance as per SMPTE EG34-1999 Pathological
Test Requirements.
As
a
second-generation
HOTLink
device,
the
CYV15G0203TB extends the HOTLink family with enhanced
levels of integration and faster data rates, while maintaining
serial-link compatibility (data, and BIST) with other HOTLink
devices. Each channel of the CYV15G0203TB Dual HOTLink
II device accepts scrambled 10-bit transmission characters.
These characters are serialized and output from dual Positive
ECL (PECL) compatible differential transmission-line drivers
at a bit-rate of either 10- or 20-times the input reference clock
for that channel.
Each channel contains an independent BIST pattern
generator. This BIST hardware allows at-speed testing of the
high-speed serial data paths in each transmit section of this
device, each receive section of a connected HOTLink II
device, and across the interconnecting links.
The CYV15G0203TB is ideal for SMPTE applications where
different data rates and serial interface standards are
necessary for each channel. Some applications include multiformat routers, switchers, format converters, and cameras.
Reclocked
Output
Video Coprocessor
10
Independent
Channel
CYV15G0203TB
Serializer
Independent
Channel
CYV15G0204RB
Reclocking Deserializer
Serial Links
10
Video Coprocessor
10
10
Reclocked
Output
Figure 1. HOTLink II™ System Connections
Cypress Semiconductor Corporation
Document #: 38-02105 Rev. **
•
3901 North First Street
•
San Jose, CA 95134
•
408-943-2600
Revised July 21, 2004
CYV15G0203TB
PRELIMINARY
Document #: 38-02105 Rev. **
REFCLKB±
TXDB[9:0]
x10
Phase
Align
Buffer
Phase
Align
Buffer
Serializer
Serializer
TX
TX
OUTB1±
OUTB2±
REFCLKA±
x10
OUTA1±
OUTA2±
TXDA[9:0]
CYV15G0203TB Serializer Logic Block Diagram
Page 2 of 19
CYV15G0203TB
PRELIMINARY
Serializer Path Block Diagram
Bit-Rate Clock A
REFCLKA+
Transmit
PLL
Transmit PLL
Clock
ClockMultiplier
Multiplier A
REFCLKA–
TXRATEA
= Internal Signal
OE[2..1]A
RESET
SPDSELA
TXCLKOA
Character-Rate Clock A
TXERRA
TXCLKA
10
OUTA1+
OUTA1–
Shifter
BIST LFSR
10
Phase-Align
Phase-Align
Buffer
Buffer
10
TXDA[9:0]
1
Input
Register
TXCKSELA
OE[2..1]A
TXBISTA
PABRSTA
0
10
OUTA2+
OUTA2–
Bit-Rate Clock B
REFCLKB+
Transmit
PLL
Transmit PLL
Clock
ClockMultiplier
Multiplier B
REFCLKB–
TXRATEB
OE[2..1]B
SPDSELB
TXCLKOB
Character-Rate Clock B
TXERRB
TXCLKB
PABRSTB
10
10
10
Shifter
10
BIST LFSR
TXDB[9:0]
Phase-Align
Phase-Align
Buffer
Buffer
TXCKSELB
OE[2..1]B
TXBISTB
1
Input
Register
0
JTAG and Device Configuration and Control Block Diagram
OUTB1+
OUTB1–
OUTB2+
OUTB2–
= Internal Signal
RESET
WREN
ADDR[2:0]
Device Configuration
and Control Interface
DATA[3:0]
Document #: 38-02105 Rev. **
TXRATE[A..B]
TXCKSEL[A..B]
PABRST[A..B]
TXBIST[A..B]
OE[2..1][A..B]
JTAG
Boundary
Scan
Controller
TRST
TMS
TCLK
TDI
TDO
Page 3 of 19
CYV15G0203TB
PRELIMINARY
Pin Configuration (Top View)[1]
A
B
C
D
E
F
G
H
J
K
L
M
N
P
R
T
U
V
W
Y
1.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
NC
NC
NC
NC
VCC
NC
OUT
B1–
GND
GND
OUT
B2–
GND
OUT
A1–
GND
GND
OUT
A2–
VCC
VCC
NC
VCC
NC
VCC
NC
VCC
NC
VCC
VCC
OUT
B1+
GND
NC
OUT
B2+
NC
OUT
A1+
GND
NC
OUT
A2+
VCC
NC
NC
NC
NC
TDI
TMS
VCC
VCC
VCC
NC
NC
GND
NC
NC
DATA
[2]
DATA
[0]
GND
NC
SPD
SELB
VCC
NC
TRST
GND
TDO
TCLK
RESET
VCC
VCC
VCC
VCC
NC
GND
GND
DATA
[3]
DATA
[1]
GND
GND
GND
NC
VCC
NC
NC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
NC
NC
VCC
NC
NC
NC
NC
NC
GND
WREN
GND
GND
NC
NC
SPD
SELA
NC
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
NC
NC
NC
NC
NC
NC
GND
GND
NC
NC
NC
NC
NC
NC
NC
GND
NC
NC
NC
GND
NC
NC
NC
NC
NC
NC
NC
GND
GND
GND
GND
GND
GND
GND
GND
GND
NC
NC
NC
NC
GND
GND
GND
GND
NC
NC
NC
NC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
TX
DB[0]
TX
DB[1]
TX
DB[2]
TX
DB[9]
VCC
NC
NC
GND
TX
DA[9]
ADDR
[0]
REF
CLKB–
TX
DB[3]
TX
DB[4]
TX
DB[8]
NC
VCC
NC
NC
GND
NC
GND
REF
TX
CLKB+ CLKOA
TX
DB[5]
TX
DB[7]
NC
NC
VCC
NC
NC
GND
ADDR
[2]
ADDR
[1]
NC
TX
DB[6]
TX
CLKB
NC
NC
VCC
NC
NC
GND
TX
CLKOB
NC
TX
CLKA
TX
DA[1]
SCAN TMEN3
EN2
GND
TX
DA[4]
TX
DA[8]
VCC
NC
VCC
NC
NC
GND
TX
DA[3]
TX
DA[7]
VCC
NC
NC
NC
NC
TX
ERRA
GND
TX
DA[2]
TX
DA[6]
VCC
NC
REF
CLKA+
NC
NC
NC
GND
TX
DA[0]
TX
DA[5]
VCC
TX
ERRB
REF
CLKA–
NC
NC
NC = Do not connect.
Document #: 38-02105 Rev. **
Page 4 of 19
CYV15G0203TB
PRELIMINARY
Pin Configuration (Bottom View)[1]
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
A
NC
VCC
NC
VCC
VCC
OUT
A2–
GND
GND
OUT
A1–
GND
OUT
B2–
GND
GND
OUT
B1–
NC
VCC
NC
NC
NC
NC
B
NC
NC
NC
NC
VCC
OUT
A2+
NC
GND
OUT
A1+
NC
OUT
B2+
NC
GND
OUT
B1+
VCC
VCC
NC
VCC
NC
VCC
C
TDO
GND
TRST
NC
VCC
SPD
SELB
NC
GND
DATA
[0]
DATA
[2]
NC
NC
GND
NC
NC
VCC
VCC
VCC
TMS
TDI
NC
NC
VCC
NC
GND
GND
GND
DATA
[1]
DATA
[3]
GND
GND
NC
VCC
VCC
VCC
VCC
RESET
TCLK
D
TMEN3 SCAN
EN2
E
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
F
NC
NC
NC
NC
NC
VCC
NC
NC
G
NC
SPD
SELA
NC
NC
GND
GND
WREN
GND
H
GND
GND
GND
GND
GND
GND
GND
GND
J
NC
NC
NC
NC
GND
GND
GND
GND
K
NC
NC
NC
NC
GND
GND
NC
NC
L
GND
NC
NC
NC
GND
NC
NC
NC
M
GND
NC
NC
NC
NC
NC
NC
NC
N
GND
GND
GND
GND
GND
GND
GND
GND
P
GND
GND
GND
GND
NC
NC
NC
NC
R
VCC
VCC
VCC
VCC
NC
NC
NC
NC
T
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
U
NC
NC
VCC
NC
VCC
TX
DA[8]
TX
DA[4]
GND
V
NC
NC
NC
NC
VCC
TX
DA[7]
TX
DA[3]
GND
W
NC
NC
REF
CLKA+
NC
VCC
TX
DA[6]
TX
DA[2]
GND
TX
ERRA
Y
NC
NC
REF
CLKA–
TX
ERRB
VCC
TX
DA[5]
TX
DA[0]
GND
NC
Document #: 38-02105 Rev. **
TX
DA[1]
REF
CLKB–
ADDR
[0]
TX
DA[9]
GND
NC
NC
VCC
TX
DB[9]
TX
DB[2]
TX
DB[1]
TX
DB[0]
TX
REF
CLKOA CLKB+
GND
NC
GND
NC
NC
VCC
NC
TX
DB[8]
TX
DB[4]
TX
DB[3]
NC
ADDR
[1]
ADDR
[2]
GND
NC
NC
VCC
NC
NC
TX
DB[7]
TX
DB[5]
TX
CLKA
NC
TX
CLKOB
GND
NC
NC
VCC
NC
NC
TX
CLKB
TX
DB[6]
Page 5 of 19
PRELIMINARY
CYV15G0203TB
Pin Definitions
CYV15G0203TB Dual HOTLink II Serializer
Name
I/O Characteristics
Signal Description
Transmit Path Data and Status Signals
TXDA[9:0]
TXDB[9:0]
LVTTL Input,
synchronous,
sampled by the
associated
TXCLKx↑ or
REFCLKx↑[2]
Transmit Data Inputs. TXDx[9:0] data inputs are captured on the rising edge of the
transmit interface clock. The transmit interface clock is selected by the TXCKSELx
latch via the device configuration interface.
TXERRA
TXERRB
LVTTL Output,
synchronous to
REFCLKx↑ [3],
asynchronous to
transmit channel
enable / disable,
asynchronous to loss
or return of
REFCLKx±
Transmit Path Error. TXERRx is asserted HIGH to indicate detection of a transmit
Phase-Align Buffer underflow or overflow. If an underflow or overflow condition is
detected, TXERRx, for the channel in error, is asserted HIGH and remains asserted
until the transmit Phase-Align Buffer is re-centered with the PABRSTx latch via the
device configuration interface. When TXBISTx = 0, the BIST progress is presented
on the associated TXERRx output. The TXERRx signal pulses HIGH for one
transmit-character clock period to indicate a pass through the BIST sequence once
every 511 character times.
TXERRx is also asserted HIGH, when any of the following conditions is true:
• The TXPLL for the associated channel is powered down. This occurs when OE2x
and OE1x for a given channel are both disabled by setting OE2x = 0 and OE1x = 0.
• The absence of the REFCLKx± signal.
Transmit Path Clock Signals
REFCLKA±
REFCLKB±
Differential LVPECL
or single-ended
LVTTL input clock
Reference Clock. REFCLKx± clock inputs are used as the timing references for the
associated transmit PLL. These input clocks may also be selected to clock the
transmit parallel interface. When driven by a single-ended LVCMOS or LVTTL clock
source, connect the clock source to either the true or complement REFCLKx input,
and leave the alternate REFCLKx input open (floating). When driven by an LVPECL
clock source, the clock must be a differential clock, using both inputs.
TXCLKA
TXCLKB
LVTTL Clock Input,
internal pull-down
Transmit Path Input Clock. When configuration latch TXCKSELx = 0, the
associated TXCLKx input is selected as the character-rate input clock for the
TXDB[9:0] input. In this mode, the TXCLKx input must be frequency-coherent to its
associated TXCLKOx output clock, but may be offset in phase by any amount. Once
initialized, TXCLKx is allowed to drift in phase as much as ±180 degrees. If the input
phase of TXCLKx drifts beyond the handling capacity of the Phase Align Buffer,
TXERRx is asserted to indicate the loss of data, and remains asserted until the
Phase Align Buffer is initialized. The phase of the TXCLKx input clock relative to its
associated REFCLKx± is initialized when the configuration latch PABRSTx is written
as 0. When the associated TXERRx is deasserted, the Phase Align Buffer is
initialized and input characters are correctly captured.
TXCLKOA
TXCLKOB
LVTTL Output
Transmit Clock Output. TXCLKOx output clock is synthesized by each channel’s
transmit PLL and operates synchronous to the internal transmit character clock.
TXCLKOx operates at either the same frequency as REFCLKx± (TXRATEx = 0), or
at twice the frequency of REFCLKx± (TXRATEx = 1). The transmit clock outputs
have no fixed phase relationship to REFCLKx±.
Device Control Signals
RESET
LVTTL Input,
asynchronous,
internal pull-up
Asynchronous Device Reset. RESET initializes all state machines, counters, and
configuration latches in the device to a known state. RESET must be asserted LOW
for a minimum pulse width. When the reset is removed, all state machines, counters
and configuration latches are at an initial state. See Table 2 for the initialize values
of the device configuration latches.
Notes:
2. When REFCLKx± is configured for half-rate operation, these inputs are sampled relative to both the rising and falling edges of the associated REFCLKx±.
3. When REFCLKx± is configured for half-rate operation, these outputs are presented relative to both the rising and falling edges of the associated REFCLKx±.
Document #: 38-02105 Rev. **
Page 6 of 19
PRELIMINARY
CYV15G0203TB
Pin Definitions (continued)
CYV15G0203TB Dual HOTLink II Serializer
Name
SPDSELA
SPDSELB
I/O Characteristics
3-Level Select[4]
static control input
Signal Description
Serial Rate Select. The SPDSELx inputs specify the operating signaling-rate range
of each channel’s PLL.
LOW = 195 – 400 MBd
MID = 400 – 800 MBd
HIGH = 800 – 1500 MBd.
Device Configuration and Control Bus Signals
WREN
LVTTL input,
asynchronous,
internal pull-up
Control Write Enable. The WREN input writes the values of the DATA[3:0] bus into
the latch specified by the address location on the ADDR[2:0] bus.[5]
ADDR[2:0]
LVTTL input
asynchronous,
internal pull-up
Control Addressing Bus. The ADDR[2:0] bus is the input address bus used to
configure the device. The WREN input writes the values of the DATA[3:0] bus into
the latch specified by the address location on the ADDR[2:0] bus.[5] Table 2 lists the
configuration latches within the device, and the initialization value of the latches upon
the assertion of RESET. Table 3 shows how the latches are mapped in the device.
DATA[3:0]
LVTTL input
asynchronous,
internal pull-up
Control Data Bus. The DATA[3:0] bus is the input data bus used to configure the
device. The WREN input writes the values of the DATA[3:0] bus into the latch
specified by address location on the ADDR[2:0] bus.[5 ] Table 2 lists the configuration
latches within the device, and the initialization value of the latches upon the assertion
of RESET. Table 3 shows how the latches are mapped in the device.
Internal Device Configuration Latches
TXCKSEL[A..B]
Internal Latch[6]
Latch[6]
TXRATE[A..B]
Internal
TXBIST[A..B]
Internal Latch[6]
Transmit Clock Select.
Transmit PLL Clock Rate Select.
Transmit Bist Disabled.
OE2[A..B]
Internal
Latch[6]
Differential Serial Output Driver 2 Enable.
OE1[A..B]
Internal Latch[6]
Differential Serial Output Driver 1 Enable.
PABRST[A..B]
Internal
Latch[6]
Transmit Clock Phase Alignment Buffer Reset.
Factory Test Modes
SCANEN2
LVTTL input,
internal pull-down
Factory Test 2. SCANEN2 input is for factory testing only. This input may be left as
a NO CONNECT, or GND only.
TMEN3
LVTTL input,
internal pull-down
Factory Test 3. TMEN3 input is for factory testing only. This input may be left as a
NO CONNECT, or GND only.
OUTA1±
OUTB1±
CML Differential
Output
Primary Differential Serial Data Output. The OUTx1± PECL-compatible CML
outputs (+3.3V referenced) are capable of driving terminated transmission lines or
standard fiber-optic transmitter modules, and must be AC-coupled for PECLcompatible connections.
OUTA2±
OUTB2±
CML Differential
Output
Secondary Differential Serial Data Output. The OUTx2± PECL-compatible CML
outputs (+3.3V referenced) are capable of driving terminated transmission lines or
standard fiber-optic transmitter modules, and must be AC-coupled for PECL-compatible
connections.
Analog I/O
Notes:
4. 3-Level Select inputs are used for static configuration. These are ternary inputs that make use of logic levels of LOW, MID, and HIGH. The LOW level is usually
implemented by direct connection to VSS (ground). The HIGH level is usually implemented by direct connection to VCC (power). The MID level is usually
implemented by not connecting the input (left floating), which allows it to self bias to the proper level.
5. See Device Configuration and Control Interface for detailed information on the operation of the Configuration Interface.
6. See Device Configuration and Control Interface for detailed information on the internal latches.
Document #: 38-02105 Rev. **
Page 7 of 19
PRELIMINARY
CYV15G0203TB
Pin Definitions (continued)
CYV15G0203TB Dual HOTLink II Serializer
Name
I/O Characteristics
Signal Description
JTAG Interface
TMS
LVTTL Input,
internal pull-up
Test Mode Select. Used to control access to the JTAG Test Modes. If maintained
high for ≥5 TCLK cycles, the JTAG test controller is reset.
TCLK
LVTTL Input,
internal pull-down
JTAG Test Clock.
TDO
3-State LVTTL Output Test Data Out. JTAG data output buffer. High-Z while JTAG test mode is not
selected.
TDI
LVTTL Input,
internal pull-up
Test Data In. JTAG data input port.
TRST
LVTTL Input,
internal pull-up
JTAG reset signal. When asserted (LOW), this input asynchronously resets the
JTAG test access port controller.
Power
VCC
+3.3V Power.
GND
Signal and Power Ground for all internal circuits.
CYV15G0203TB HOTLink II Operation
The CYV15G0203TB is a highly configurable, independent
clocking, dual-channel serializer, designed to support reliable
transfer of large quantities of digital video data, using highspeed serial links from multiple sources to multiple destinations. This device supports two 10-bit channels.
reset. While the error remains active, the transmitter for that
channel outputs a continuous “1001111000” character (LSB
first) to indicate to the remote receiver that an error condition
is present in the link.
CYV15G0203TB Transmit Data Path
Each channel contains an internal pattern generator that can
be used to validate both the link and device operation. These
generators are enabled by the associated TXBISTx latch via
the device configuration interface. When enabled, a register in
the associated channel becomes a signature pattern
generator by logically converting to a Linear Feedback Shift
Register (LFSR). This LFSR generates a 511-character
sequence. This provides a predictable yet pseudo-random
sequence that can be matched to an identical LFSR in the
attached Receiver(s).
Input Register
The parallel input bus TXDx[9:0] can be clocked in using
TXCLKx (TXCKSELx = 0) or REFCLKx (TXCKSELx = 1).
Phase-Align Buffer
Data from each Input Register is passed to the associated
Phase-Align Buffer, when the TXDx[9:0] input registers are
clocked using TXCLKx (TXCKSELx = 0 and TXRATEx = 0).
When the TXDx[9:0] input registers are clocked using
REFCLKx± (TXCKSELx = 1) and REFCLKx± is a full-rate
clock, the associated Phase Alignment Buffer in the transmit
path is bypassed. These buffers are used to absorb clock
phase differences between the TXCLKx input clock and the
internal character clock for that channel.
Once initialized, TXCLKx is allowed to drift in phase as much
as ±180 degrees. If the input phase of TXCLKx drifts beyond
the handling capacity of the Phase Align Buffer, TXERRx is
asserted to indicate the loss of data, and remains asserted
until the Phase Align Buffer is initialized. The phase of the
TXCLKx relative to its associated internal character rate clock
is initialized when the configuration latch PABRSTx is written
as 0. When the associated TXERRx is deasserted, the Phase
Align Buffer is initialized and input characters are correctly
captured.
If the phase offset, between the initialized location of the input
clock and REFCLKx, exceeds the skew handling capabilities
of the Phase-Align Buffer, an error is reported on that
channel’s TXERRx output. This output indicates an error
continuously until the Phase-Align Buffer for that channel is
Document #: 38-02105 Rev. **
Transmit BIST
A device reset (RESET sampled LOW) presets the BIST
Enable Latches to disable BIST on both channels.
All data present at the associated TXDx[9:0] inputs are ignored
when BIST is active on that channel.
Transmit PLL Clock Multiplier
Each Transmit PLL Clock Multiplier accepts a character-rate
or half-character-rate external clock at the associated
REFCLKx± input, and that clock is multiplied by 10 or 20 (as
selected by TXRATEx) to generate a bit-rate clock for use by
the transmit shifter. It also provides a character-rate clock used
by the transmit paths, and outputs this character rate clock as
TXCLKOx.
Each clock multiplier PLL can accept a REFCLKx± input
between 19.5 MHz and 150 MHz, however, this clock range is
limited by the operating mode of the CYV15G0203TB clock
multiplier (TXRATEx) and by the level on the associated
SPDSELx input.
SPDSELx are 3-level select[4] inputs that select one of three
operating ranges for the serial data outputs and inputs of the
Page 8 of 19
PRELIMINARY
associated channel. The serial signaling-rate and allowable
range of REFCLKx± frequencies are listed in Table 1.
Table 1. Operating Speed Settings
SPDSELx
TXRATEx
REFCLKx±
Frequency
(MHz)
LOW
1
reserved
0
19.5 – 40
MID (Open)
1
20 – 40
0
40 – 80
HIGH
1
40 – 75
0
80 – 150
Signaling
Rate (Mbps)
195 – 400
400 – 800
800 – 1500
The REFCLKx± inputs are differential inputs with each input
internally biased to 1.4V. If the REFCLKx+ input is connected
to a TTL, LVTTL, or LVCMOS clock source, the input signal is
recognized when it passes through the internally biased
reference point. When driven by a single-ended TTL, LVTTL,
or LVCMOS clock source, connect the clock source to either
the true or complement REFCLKx input, and leave the
alternate REFCLKx input open (floating).
When both the REFCLKx+ and REFCLKx– inputs are
connected, the clock source must be a differential clock. This
can either be a differential LVPECL clock that is DC-or
AC-coupled or a differential LVTTL or LVCMOS clock.
By connecting the REFCLKx– input to an external voltage
source, it is possible to adjust the reference point of the
REFCLKx+ input for alternate logic levels. When doing so, it
is necessary to ensure that the input differential crossing point
remains within the parametric range supported by the input.
Serial Output Drivers
The serial output interface drivers use differential Current
Mode Logic (CML) drivers to provide source-matched drivers
for 50Ω transmission lines. These drivers accept data from the
Transmit Shifter, which shifts the data out LSB first. These
drivers have signal swings equivalent to that of standard PECL
drivers, and are capable of driving AC-coupled optical
modules or transmission lines.
Transmit Channels Enabled
Each driver can be enabled or disabled separately via the
device configuration interface.
CYV15G0203TB
When a driver is disabled via the configuration interface, it is
internally powered down to reduce device power. If both serial
drivers for a channel are in this disabled state, the associated
internal logic for that channel is also powered down. A device
reset (RESET sampled LOW) disables all output drivers.
Note. When a disabled channel (i.e., both outputs disabled) is
re-enabled:
• data on the serial outputs may not meet all timing specifications for up to 250 µs
• the state of the phase-align buffer cannot be guaranteed,
and a phase-align reset is required if the phase-align buffer
is used
Device Configuration and Control Interface
The CYV15G0203TB is highly configurable via the configuration interface. The configuration interface allows each
channel to be configured independently. Table 2 lists the
configuration latches within the device including the initialization value of the latches upon the assertion of RESET.
Table 3 shows how the latches are mapped in the device.
Each row in the Table 3 maps to a 4-bit latch bank. There are
6 such write-only latch banks. When WREN = 0, the logic value
in the DATA[3:0] is latched to the latch bank specified by the
values in ADDR[2:0]. The second column of Table 3 specifies
the channels associated with the corresponding latch bank.
For example, the first three latch banks (0,1 and 2) consist of
configuration bits for channel A.
Latch Types
There are two types of latch banks: static (S) and dynamic (D).
Each channel is configured by 2 static and 1 dynamic latch
banks. The S type contain those settings that normally do not
change for a given application, whereas the D type controls
the settings that could change during the application's lifetime.
The first and second rows of each channel (address numbers
0, 1, 5, and 6) are the static control latches. The third row of
latches for each channel (address numbers 2 and 7) are the
dynamic control latches. Address numbers 3 and 4 are internal
test registers.
Static Latch Values
There are some latches in the table that have a static value
(i.e. 1, 0, or X). The latches that have a ‘1’ or ‘0’ must be
configured with their corresponding value each time that their
associated latch bank is configured. The latches that have an
‘X’ are don’t cares and can be configured with any value.
Table 2. Device Configuration and Control Latch Descriptions
Name
Signal Description
TXCKSELA
TXCKSELB
Transmit Clock Select. The initialization value of the TXCKSELx latch = 1. TXCKSELx selects the clock
source used to write data into the Transmit Input Register. When TXCKSELx = 1, the associated input
register TXDx[9:0] is clocked by REFCLKx↑. In this mode, the phase alignment buffer is bypassed. When
TXCKSELx = 0, the associated TXCLKx↑ is used to clock in the input register TXDx[9:0].
TXRATEA
TXRATEB
Transmit PLL Clock Rate Select. The initialization value of the TXRATEx latch = 0. TXRATEx is used
to select the clock multiplier for the Transmit PLL. When TXRATEx = 0, each transmit PLL multiples the
associated REFCLKx± input by 10 to generate the serial bit-rate clock. When TXRATEx = 0, the
TXCLKOx output clocks are full-rate clocks and follow the frequency and duty cycle of the associated
REFCLKx± input. When TXRATEx = 1, each Transmit PLL multiplies the associated REFCLKx± input
by 20 to generate the serial bit-rate clock. When TXRATEx = 1, the TXCLKOx output clocks are twice
the frequency rate of the REFCLKx± input. When TXCLKSELx = 1 and TXRATEx = 1, the Transmit Data
Inputs are captured using both the rising and falling edges of REFCLKx. TXRATEx = 1 and SPDSELx
= LOW, is an invalid state and this combination is reserved.
Document #: 38-02105 Rev. **
Page 9 of 19
CYV15G0203TB
PRELIMINARY
Table 2. Device Configuration and Control Latch Descriptions (continued)
TXBISTA
TXBISTB
Transmit Bist Disabled. The initialization value of the TXBISTx latch = 1. TXBISTx selects if the transmit
BIST is disabled or enabled. When TXBISTx = 1, the transmit BIST function is disabled. When
TXBISTx = 0, the transmit BIST function is enabled.
OE2A
OE2B
Secondary Differential Serial Data Output Driver Enable. The initialization value of the OE2x latch =
0. OE2x selects if the OUT2x± secondary differential output drivers are enabled or disabled. When OE2x
= 1, the associated serial data output driver is enabled allowing data to be transmitted from the transmit
shifter. When OE2x = 0, the associated serial data output driver is disabled. When a driver is disabled
via the configuration interface, it is internally powered down to reduce device power. If both serial drivers
for a channel are in this disabled state, the associated internal logic for that channel is also powered
down. A device reset (RESET sampled LOW) disables all output drivers.
OE1A
OE1B
Primary Differential Serial Data Output Driver Enable. The initialization value of the OE1x latch = 0.
OE1x selects if the OUT1x± primary differential output drivers are enabled or disabled. When OE1x =
1, the associated serial data output driver is enabled allowing data to be transmitted from the transmit
shifter. When OE1x = 0, the associated serial data output driver is disabled. When a driver is disabled
via the configuration interface, it is internally powered down to reduce device power. If both serial drivers
for a channel are in this disabled state, the associated internal logic for that channel is also powered
down. A device reset (RESET sampled LOW) disables all output drivers.
PABRSTA
PABRSTB
Transmit Clock Phase Alignment Buffer Reset. The initialization value of the PABRSTx latch = 1. The
PABRSTx is used to re-center the Transmit Phase Align Buffer. When the configuration latch PABRSTx
is written as a 0, the phase of the TXCLKx input clock relative to its associated REFCLKx+/- is initialized.
PABRST is an asynchronous input, but is sampled by each TXCLKx↑ to synchronize it to the internal
clock domain. PABRSTx is a self clearing latch. This eliminates the requirement of writing a 1 to complete
the initialization of the Phase Alignment Buffer.
Device Configuration Strategy
2. Set the static latch banks for the target channel.
The following is a series of ordered events needed to load the
configuration latches on a per channel basis:
3. Set the dynamic bank of latches for the target channel.
Enable the output drivers. [Required step.]
1. Pulse RESET Low after device power-up. This operation
resets both channels.
4. Reset the Phase Alignment Buffer for the target channel.
[Optional if phase align buffer is bypassed.]
Table 3. Device Control Latch Configuration Table
ADDR
Channel
Type
DATA3
DATA2
DATA1
DATA0
Reset
Value
0
(000b)
A
S
X
X
0
X
1111
1
(001b)
A
S
X
0
TXCKSELA
TXRATEA
0110
2
(010b)
A
D
TXBISTA
OE2A
OE1A
PABRSTA
1001
9
(101b)
B
S
X
X
0
X
1111
10
(110b)
B
S
X
0
TXCKSELB
TXRATEB
0110
11
(111b)
B
D
TXBISTB
OE2B
OE1B
PABRSTB
1001
JTAG Support
The CYV15G0203TB contains a JTAG port to allow system
level diagnosis of device interconnect. Of the available JTAG
modes, boundary scan, and bypass are supported. This
capability is present only on the LVTTL inputs and outputs and
the REFCLKx± clock input. The high-speed serial inputs and
outputs are not part of the JTAG test chain.
Document #: 38-02105 Rev. **
3-Level Select Inputs
Each 3-Level select inputs reports as two bits in the scan
register. These bits report the LOW, MID, and HIGH state of
the associated input as 00, 10, and 11 respectively
JTAG ID
The JTAG device ID for the CYV15G0203TB is ‘0C810069’x.
Page 10 of 19
CYV15G0203TB
PRELIMINARY
Maximum Ratings
Above which the useful life may be impaired. User guidelines
only, not tested
Static Discharge Voltage.......................................... > 2000 V
(per MIL-STD-883, Method 3015)
Latch-up Current..................................................... > 200 mA
Storage Temperature .................................. –65°C to +150°C
Power-up Requirements
Ambient Temperature with
Power Applied............................................. –55°C to +125°C
The CYV15G0203TB requires one power-supply. The Voltage
on any input or I/O pin cannot exceed the power pin during
power-up.
Supply Voltage to Ground Potential ............... –0.5V to +3.8V
DC Voltage Applied to LVTTL Outputs
in High-Z State .......................................–0.5V to VCC + 0.5V
Output Current into LVTTL Outputs (LOW)..................60 mA
DC Input Voltage....................................–0.5V to VCC + 0.5V
Operating Range
Range
Ambient Temperature
VCC
Commercial
0°C to +70°C
+3.3V ±5%
CYV15G0203TB DC Electrical Characteristics
Parameter
Description
LVTTL-compatible Outputs
Output HIGH Voltage
VOHT
Output LOW Voltage
VOLT
Output Short Circuit Current
IOST
IOZL
High-Z Output Leakage Current
LVTTL-compatible Inputs
Input HIGH Voltage
VIHT
VILT
Input LOW Voltage
Input HIGH Current
IIHT
IILT
Input LOW Current
Test Conditions
IOH = − 4 mA, VCC = Min.
IOL = 4 mA, VCC = Min.
VOUT = 0V[7], VCC = 3.3V
VOUT = 0V, VCC
Min.
Unit
0.4
–100
20
V
V
mA
µA
VCC + 0.3
0.8
1.5
+40
–1.5
–40
+200
–200
V
V
mA
µA
mA
µA
µA
µA
2.4
–20
–20
2.0
–0.5
REFCLKx Input, VIN = VCC
Other Inputs, VIN = VCC
REFCLKx Input, VIN = 0.0V
Other Inputs, VIN = 0.0V
VIN = VCC
VIN = 0.0V
Max.
Input HIGH Current with internal pull-down
IIHPDT
IILPUT
Input LOW Current with internal pull-up
LVDIFF Inputs: REFCLKx±
Input Differential Voltage
400
VCC
VDIFF[8]
VIHHP
Highest Input HIGH Voltage
1.2
VCC
Lowest Input LOW voltage
0.0
VCC/2
VILLP
1.0
VCC – 1.2V
VCOMREF[9] Common Mode Range
3-Level Inputs
Three-Level Input HIGH Voltage
Min. ≤ VCC ≤ Max.
0.87 * VCC
VCC
VIHH
Three-Level Input MID Voltage
Min. ≤ VCC ≤ Max.
0.47 * VCC
0.53 * VCC
VIMM
Three-Level Input LOW Voltage
Min. ≤ VCC ≤ Max.
0.0
0.13 * VCC
VILL
Input HIGH Current
VIN = VCC
200
IIHH
Input MID current
VIN = VCC/2
–50
50
IIMM
Input LOW current
VIN = GND
–200
IILL
Differential CML Serial Outputs: OUTA1±, OUTA2±, OUTB1±, OUTB2±, OUTC1±, OUTC2±, OUTD1±, OUTD2±
100Ω differential load
VCC – 0.5
Output HIGH Voltage
VCC – 0.2
VOHC
(Vcc Referenced)
VCC – 0.2
150Ω differential load
VCC – 0.5
Output LOW Voltage
VOLC
100Ω differential load
VCC – 1.4 VCC – 0.7
(VCC Referenced)
VCC – 0.7
150Ω differential load
VCC – 1.4
Output Differential Voltage
100Ω differential load
450
900
VODIF
|(OUT+) − (OUT−)|
150Ω differential load
560
1000
7.
8.
9.
mV
V
V
V
V
V
V
µA
µA
µA
V
V
V
V
mV
mV
Tested one output at a time, output shorted for less than one second, less than 10% duty cycle.
This is the minimum difference in voltage between the true and complement inputs required to ensure detection of a logic-1 or logic-0. A logic-1 exists when
the true (+) input is more positive than the complement (−) input. A logic-0 exists when the complement (−) input is more positive than true (+) input.
The common mode range defines the allowable range of REFCLKx+ and REFCLKx− when REFCLKx+ = REFCLKx−. This marks the zero-crossing between
the true and complement inputs as the signal switches between a logic-1 and a logic-0.
Document #: 38-02105 Rev. **
Page 11 of 19
CYV15G0203TB
PRELIMINARY
CYV15G0203TB DC Electrical Characteristics (continued)
Parameter
Description
Power Supply
ICC [10,11]
Max Power Supply Current
ICC [10,11]
Test Conditions
REFCLKx Commercial
= MAX
REFCLKx Commercial
= 125 MHz
Typical Power Supply Current
Min.
Typ.
435
Max.
Max.
530
Unit
425
520
mA
mA
AC Test Loads and Waveforms
3.3V
RL = 100Ω
R1
R1 = 590Ω
R2 = 435Ω
CL
CL ≤ 7 pF
(Includes fixture and
probe capacitance)
(Includes fixture and
probe capacitance)
R2
(a) LVTTL Output Test Load
(b) CML Output Test Load
Vth = 1.4V
0.8V
GND
2.0V
0.8V
Note 12
Note 12
3.0V
2.0V
RL
VIHE
VIHE
Vth = 1.4V
≤ 1 ns
VILE
≤ 1 ns
(c) LVTTL Input Test Waveform
Note 13
80%
80%
20%
≤ 270 ps
20%
VILE
≤ 270 ps
(d) CML/LVPECL Input Test Waveform
CYV15G0203TB AC Electrical Characteristics
Parameter
Description
CYV15G0203TB Transmitter LVTTL Switching Characteristics Over the Operating Range
TXCLKx Clock Cycle Frequency
fTS
TXCLKx Period=1/fTS
tTXCLK
[14]
TXCLKx HIGH Time
tTXCLKH
tTXCLKL[14]
TXCLKx LOW Time
TXCLKx Rise Time
tTXCLKR [14, 15, 16,
17]
Min.
Max
Unit
19.5
6.66
2.2
2.2
0.2
150
51.28
1.7
MHz
ns
ns
ns
ns
1.7
ns
150
51.28
0
ns
ns
MHz
ns
ns
tTXCLKF [14, 15, 16,
TXCLKx Fall Time
0.2
tTXDS
tTXDH
fTOS
tTXCLKO
tTXCLKOD
Transmit Data Set-up Time to TXCLKx↑ (TXCKSELx = 0)
Transmit Data Hold Time from TXCLKx↑ (TXCKSELx = 0)
TXCLKOx Clock Frequency = 1x or 2x REFCLKx Frequency
TXCLKOx Period=1/fTOS
TXCLKO Duty Cycle centered at 60% HIGH time
2.2
0.8
19.5
6.66
-1.9
17]
Notes:
10. Maximum ICC is measured with VCC = MAX, TA = 25°C, with both channels and Serial Line Drivers enabled, sending a continuous alternating 01 pattern, and
outputs unloaded.
11. Typical ICC is measured under similar conditions except with VCC = 3.3V, TA = 25°C, with both channels enabled and one Serial Line Driver per channel sending
a continuous alternating 01 pattern. The redundant outputs on each channel are powered down.
12. Cypress uses constant current (ATE) load configurations and forcing functions. This figure is for reference only.
13. The LVTTL switching threshold is 1.4V. All timing references are made relative to where the signal edges cross the threshold voltage.
14. Tested initially and after any design or process changes that may affect these parameters, but not 100% tested.
15. The ratio of rise time to falling time must not vary by greater than 2:1.
16. For a given operating frequency, neither rise or fall specification can be greater than 20% of the clock-cycle period or the data sheet maximum time.
17. All transmit AC timing parameters measured with 1ns typical rise time and fall time.
Document #: 38-02105 Rev. **
Page 12 of 19
CYV15G0203TB
PRELIMINARY
CYV15G0203TB AC Electrical Characteristics (continued)
Parameter
Description
Min.
CYV15G0203TB REFCLKx Switching Characteristics Over the Operating Range
fREF
REFCLKx Clock Frequency
19.5
REFCLKx Period = 1/fREF
6.6
tREFCLK
REFCLKx HIGH Time (TXRATEx = 1)(Half Rate)
5.9
tREFH
REFCLKx HIGH Time (TXRATEx = 0)(Full Rate)
2.9[14]
tREFL
REFCLKx LOW Time (TXRATEx = 1)(Half Rate)
5.9
REFCLKx LOW Time (TXRATEx = 0)(Full Rate)
2.9[14]
REFCLKx Duty Cycle
30
tREFD[18]
tREFR [14, 15, 16, 17] REFCLKx Rise Time (20%–80%)
REFCLKx Fall Time (20%–80%)
tREFF[14, 15, 16, 17]
Transmit Data Set-up Time to REFCLKx - Full Rate (TXRATEx = 0,
2.2
tTREFDS
TXCKSELx = 1)
Transmit Data Set-up Time to REFCLKx - Half Rate (TXRATEx = 1,
1.9
TXCKSELx = 1)
tTREFDH
Transmit Data Hold Time from REFCLKx - Full Rate (TXRATEx = 0,
0.8
TXCKSELx = 1)
Transmit Data Hold Time from REFCLKx - Half Rate (TXRATEx = 1,
1.5
TXCKSELx = 1)
CYV15G0203TB Bus Configuration Write Timing Characteristics Over the Operating Range
tDATAH
Bus Configuration Data Hold
0
tDATAS
Bus Configuration Data Setup
10
Bus Configuration WREN Pulse Width
10
tWRENP
CYV15G0203TB JTAG Test Clock Characteristics Over the Operating Range
JTAG Test Clock Frequency
fTCLK
JTAG Test Clock Period
50
tTCLK
CYV15G0203TB Device RESET Characteristics Over the Operating Range
tRST
Device RESET Pulse Width
30
CYV15G0203TB Transmit Serial Outputs and TX PLL Characteristics Over the Operating Range
Parameter
Description
Condition
Min.
Bit Time
5128
tB
CML Output Rise Time 20−80% (CML Test Load)
SPDSELx =
50
tRISE[14]
HIGH
SPDSELx = MID
100
SPDSELx =LOW
180
[14]
CML Output Fall Time 80−20% (CML Test Load)
SPDSELx =
50
tFALL
HIGH
SPDSELx = MID
100
SPDSELx =LOW
180
Max
Unit
150
51.28
MHz
ns
ns
ns
ns
ns
%
ns
ns
ns
70
2
2
ns
ns
ns
ns
ns
ns
20
MHz
ns
ns
Max.
660
270
Unit
ps
ps
500
1000
270
ps
ps
ps
500
1000
ps
ps
PLL Characteristics
Parameter
Description
Condition
Min.
Typ.
Max.
Unit
CYV15G0203TB Transmitter PLL Characteristics
tJTGENSD[14, 19]
Transmit Jitter Generation - SD Data Rate
REFCLKx = 27 MHz
200
tJTGENHD[14, 19]
Transmit Jitter Generation - HD Data Rate
REFCLKx = 148.5 MHz
76
tTXLOCK
Transmit PLL lock to REFCLKx±
ps
ps
200
µs
Notes:
18. The duty cycle specification is a simultaneous condition with the tREFH and tREFL parameters. This means that at faster character rates the REFCLKx± duty
cycle cannot be as large as 30%–70%.
19. While sending BIST data at the corresponding data rate, after 10,000 histogram hits on a digital sampling oscilloscope, time referenced to REFCLKx± input.
Document #: 38-02105 Rev. **
Page 13 of 19
CYV15G0203TB
PRELIMINARY
Capacitance[14]
Max.
Unit
CINTTL
Parameter
TTL Input Capacitance
Description
TA = 25°C, f0 = 1 MHz, VCC = 3.3V
Test Conditions
7
pF
CINPECL
PECL input Capacitance
TA = 25°C, f0 = 1 MHz, VCC = 3.3V
4
pF
CYV15G0203TB HOTLink II Transmitter Switching Waveforms
tTXCLK
Transmit Interface
Write Timing
TXCLKx selected
tTXCLKH
tTXCLKL
TXCLKx
tTXDS
tTXDH
TXDx[9:0]
Transmit Interface
Write Timing
REFCLKx selected
TXRATEx = 0
tREFH
tREFCLK
tREFL
REFCLKx
tTREFDS
tTREFDH
TXDx[9:0]
Transmit Interface
Write Timing
REFCLKx selected
TXRATEx = 1
tREFCLK
tREFH
tREFL
REFCLKx
Note 20
tTREFDS
tTREFDH
tTREFDS
tTREFDH
TXDx[9:0]
Transmit Interface
TXCLKOx Timing
tREFCLK
tREFH
TXRATEx = 1
REFCLKx
tREFL
Note 21
tTXCLKO
Note 22
TXCLKOx
(internal)
Document #: 38-02105 Rev. **
Page 14 of 19
CYV15G0203TB
PRELIMINARY
CYV15G0203TB HOTLink II Transmitter Switching Waveforms (continued)
Transmit Interface
TXCLKOx Timing
tREFCLK
tREFH
TXRATEx = 0
tREFL
Note21
REFCLKx
ttTXCLKO
TXCLKO
Note22
TXCLKOx
CYV15G0203TB HOTLink II Bus Configuration Switching Waveforms
Bus Configuration
Write Timing
ADDR[2:0]
DATA[3:0]
tWRENP
WREN
tDATAS
tDATAH
Notes:
20. When REFCLKx± is configured for half-rate operation (TXRATEx = 1) and data is captured using REFCLKx instead of a TXCLKx clock. Data is captured using
both the rising and falling edges of REFCLKx.
21. The TXCLKOx output remains at the character rate regardless of the state of TXRATEx and does not follow the duty cycle of REFCLKx±.
22. The rising edge of TXCLKOx output has no direct phase relationship to the REFCLKx± input.
Document #: 38-02105 Rev. **
Page 15 of 19
CYV15G0203TB
PRELIMINARY
Table 4. Package Coordinate Signal Allocation
Ball
ID
Signal Name
Signal Type
Ball
ID
Signal Name
Signal Type
Ball
ID
Signal Name
Signal Type
A01
NC
NO CONNECT
C07
NC
NO CONNECT
F17
NC
NO CONNECT
A02
NC
NO CONNECT
C08
GND
GROUND
F18
NC
NO CONNECT
A03
NC
NO CONNECT
C09
NC
NO CONNECT
F19
NC
NO CONNECT
A04
NC
NO CONNECT
C10
NC
NO CONNECT
F20
NC
NO CONNECT
A05
VCC
POWER
C11
DATA[2]
LVTTL IN PU
G01
GND
GROUND
A06
NC
NO CONNECT
C12
DATA[0]
LVTTL IN PU
G02
WREN
LVTTL IN PU
A07
OUTB1–
CML OUT
C13
GND
GROUND
G03
GND
GROUND
A08
GND
GROUND
C14
NC
NO CONNECT
G04
GND
GROUND
A09
GND
GROUND
C15
SPDSELB
3-LEVEL SEL
G17
NC
NO CONNECT
A10
OUTB2–
CML OUT
C16
VCC
POWER
G18
NC
NO CONNECT
A11
GND
GROUND
C17
NC
NO CONNECT
G19
SPDSELA
3-LEVEL SEL
A12
OUTA1–
CML OUT
C18
TRST
LVTTL IN PU
G20
NC
NO CONNECT
A13
GND
GROUND
C19
GND
GROUND
H01
GND
GROUND
A14
GND
GROUND
C20
TDO
LVTTL 3-S OUT
H02
GND
GROUND
A15
OUTA2–
CML OUT
D01
TCLK
LVTTL IN PD
H03
GND
GROUND
A16
VCC
POWER
D02
RESET
LVTTL IN PU
H04
GND
GROUND
A17
VCC
POWER
D03
VCC
POWER
H17
GND
GROUND
A18
NC
NO CONNECT
D04
VCC
POWER
H18
GND
GROUND
A19
VCC
POWER
D05
VCC
POWER
H19
GND
GROUND
A20
NC
NO CONNECT
D06
VCC
POWER
H20
GND
GROUND
B01
VCC
POWER
D07
NC
NO CONNECT
J01
GND
GROUND
B02
NC
NO CONNECT
D08
GND
GROUND
J02
GND
GROUND
B03
VCC
POWER
D09
GND
GROUND
J03
GND
GROUND
B04
NC
NO CONNECT
D10
DATA[3]
LVTTL IN PU
J04
GND
GROUND
B05
VCC
POWER
D11
DATA[1]
LVTTL IN PU
J17
NC
NO CONNECT
B06
VCC
POWER
D12
GND
GROUND
J18
NC
NO CONNECT
B07
OUTB1+
CML OUT
D13
GND
GROUND
J19
NC
NO CONNECT
B08
GND
GROUND
D14
GND
GROUND
J20
NC
NO CONNECT
B09
NC
NO CONNECT
D15
NC
NO CONNECT
K01
NC
NO CONNECT
B10
OUTB2+
CML OUT
D16
VCC
POWER
K02
NC
NO CONNECT
B11
NC
NO CONNECT
D17
NC
NO CONNECT
K03
GND
GROUND
B12
OUTA1+
CML OUT
D18
NC
NO CONNECT
K04
GND
GROUND
B13
GND
GROUND
D19
SCANEN2
LVTTL IN PD
K17
NC
NO CONNECT
B14
NC
NO CONNECT
D20
TMEN3
LVTTL IN PD
K18
NC
NO CONNECT
B15
OUTA2+
CML OUT
E01
VCC
POWER
K19
NC
NO CONNECT
B16
VCC
POWER
E02
VCC
POWER
K20
NC
NO CONNECT
B17
NC
NO CONNECT
E03
VCC
POWER
L01
NC
NO CONNECT
B18
NC
NO CONNECT
E04
VCC
POWER
L02
NC
NO CONNECT
B19
NC
NO CONNECT
E17
VCC
POWER
L03
NC
NO CONNECT
B20
NC
NO CONNECT
E18
VCC
POWER
L04
GND
GROUND
C01
TDI
LVTTL IN PU
E19
VCC
POWER
L17
NC
NO CONNECT
C02
TMS
LVTTL IN PU
E20
VCC
POWER
L18
NC
NO CONNECT
C03
VCC
POWER
F01
NC
NO CONNECT
L19
NC
NO CONNECT
Document #: 38-02105 Rev. **
Page 16 of 19
CYV15G0203TB
PRELIMINARY
Table 4. Package Coordinate Signal Allocation (continued)
Ball
ID
Signal Name
Signal Type
Ball
ID
Signal Name
Signal Type
Ball
ID
Signal Name
Signal Type
C04
VCC
POWER
F02
NC
NO CONNECT
L20
GND
GROUND
C05
VCC
POWER
F03
VCC
POWER
M01
NC
NO CONNECT
C06
NC
NO CONNECT
F04
NC
NO CONNECT
M02
NC
NO CONNECT
M03
NC
NO CONNECT
U03
TXDB[2]
LVTTL IN
W03
NC
NO CONNECT
M04
NC
NO CONNECT
U04
TXDB[9]
LVTTL IN
W04
NC
NO CONNECT
M17
NC
NO CONNECT
U05
VCC
POWER
W05
VCC
POWER
M18
NC
NO CONNECT
U06
NC
NO CONNECT
W06
NC
NO CONNECT
M19
NC
NO CONNECT
U07
NC
NO CONNECT
W07
NC
NO CONNECT
M20
GND
GROUND
U08
GND
GROUND
W08
GND
GROUND
N01
GND
GROUND
U09
TXDA[9]
LVTTL IN
W09
ADDR [2]
LVTTL IN PU
N02
GND
GROUND
U10
ADDR [0]
LVTTL IN PU
W10
ADDR [1]
LVTTL IN PU
N03
GND
GROUND
U11
REFCLKB–
PECL IN
W11
NC
NO CONNECT
N04
GND
GROUND
U12
TXDA[1]
LVTTL IN
W12
TXERRA
LVTTL OUT
N17
GND
GROUND
U13
GND
GROUND
W13
GND
GROUND
N18
GND
GROUND
U14
TXDA[4]
LVTTL IN
W14
TXDA[2]
LVTTL IN
N19
GND
GROUND
U15
TXDA[8]
LVTTL IN
W15
TXDA[6]
LVTTL IN
N20
GND
GROUND
U16
VCC
POWER
W16
VCC
POWER
P01
NC
NO CONNECT
U17
NC
NO CONNECT
W17
NC
NO CONNECT
P02
NC
NO CONNECT
U18
VCC
POWER
W18
REFCLKA+
PECL IN
P03
NC
NO CONNECT
U19
NC
NO CONNECT
W19
NC
NO CONNECT
P04
NC
NO CONNECT
U20
NC
NO CONNECT
W20
NC
NO CONNECT
P17
GND
GROUND
V01
TXDB[3]
LVTTL IN
Y01
TXDB[6]
LVTTL IN
P18
GND
GROUND
V02
TXDB[4]
LVTTL IN
Y02
TXCLKB
LVTTL IN PD
P19
GND
GROUND
V03
TXDB[8]
LVTTL IN
Y03
NC
NO CONNECT
P20
GND
GROUND
V04
NC
NO CONNECT
Y04
NC
NO CONNECT
R01
NC
NO CONNECT
V05
VCC
POWER
Y05
VCC
POWER
R02
NC
NO CONNECT
V06
NC
NO CONNECT
Y06
NC
NO CONNECT
R03
NC
NO CONNECT
V07
NC
NO CONNECT
Y07
NC
NO CONNECT
R04
NC
NO CONNECT
V08
GND
GROUND
Y08
GND
GROUND
R17
VCC
POWER
V09
NC
NO CONNECT
Y09
TXCLKOB
LVTTL OUT
R18
VCC
POWER
V10
GND
GROUND
Y10
NC
NO CONNECT
R19
VCC
POWER
V11
REFCLKB+
PECL IN
Y11
TXCLKA
LVTTL IN PD
R20
VCC
POWER
V12
TXCLKOA
LVTTL OUT
Y12
NC
NO CONNECT
T01
VCC
POWER
V13
GND
GROUND
Y13
GND
GROUND
T02
VCC
POWER
V14
TXDA[3]
LVTTL IN
Y14
TXDA[0]
LVTTL IN
T03
VCC
POWER
V15
TXDA[7]
LVTTL IN
Y15
TXDA[5]
LVTTL IN
T04
VCC
POWER
V16
VCC
POWER
Y16
VCC
POWER
T17
VCC
POWER
V17
NC
NO CONNECT
Y17
TXERRB
LVTTL OUT
T18
VCC
POWER
V18
NC
NO CONNECT
Y18
REFCLKA–
PECL IN
T19
VCC
POWER
V19
NC
NO CONNECT
Y19
NC
NO CONNECT
T20
VCC
POWER
V20
NC
NO CONNECT
Y20
NC
NO CONNECT
U01
TXDB[0]
LVTTL IN
W01
TXDB[5]
LVTTL IN
U02
TXDB[1]
LVTTL IN
W02
TXDB[7]
LVTTL IN
Document #: 38-02105 Rev. **
Page 17 of 19
CYV15G0203TB
PRELIMINARY
Ordering Information
Speed
Standard
Ordering Code
CYV15G0203TB-BGC
Package Name
BL256
Package Type
256-Ball Thermally Enhanced Ball Grid Array
Operating
Range
Commercial
Package Diagram
256-Lead L2 Ball Grid Array (27 x 27 x 1.57 mm) BL256
51-85123-*E
HOTLink is a registered trademark and HOTLink II is a trademark of Cypress Semiconductor. All product and company names
mentioned in this document may be the trademarks of their respective holders.
Document #: 38-02105 Rev. **
Page 18 of 19
© Cypress Semiconductor Corporation, 2004. The information contained herein is subject to change without notice. Cypress Semiconductor Corporation assumes no responsibility for the use
of any circuitry other than circuitry embodied in a Cypress product. Nor does it convey or imply any license under patent or other rights. Cypress products are not warranted nor intended to be
used for medical, life support, life saving, critical control or safety applications, unless pursuant to an express written agreement with Cypress. Furthermore, Cypress does not authorize its
products for use as critical components in life-support systems where a malfunction or failure may reasonably be expected to result in significant injury to the user. The inclusion of Cypress
products in life-support systems application implies that the manufacturer assumes all risk of such use and in doing so indemnifies Cypress against all charges.
CYV15G0203TB
PRELIMINARY
Document History Page
Document Title: CYV15G0203TB Independent Clock Dual HOTLink II™ Serializer
Document Number: 38-02105
REV.
ECN NO.
ISSUE
DATE
ORIG. OF
CHANGE
**
246850
See ECN
FRE
Document #: 38-02105 Rev. **
DESCRIPTION OF CHANGE
New Data Sheet
Page 19 of 19