CORCOM Product Guide High Performance Compact RFI Power Line Filters with IEC Connectors EC Series EC8 UL Recognized CSA Certified VDE Approved EC2 EC4 EC1 EC Series Specifications The EC series RFI power line filters provide the highest attenuation of any standard filter available in a package size limited by the dimensions of the integral IEC connector. These filters combine high common-mode inductance with high differential-mode capacitance and minimal parasitic elements, for effective attenuation of line-to-ground and line-to-line noise across the frequency range. Performance and applications are similar to those of the ED series, but with higher differential-mode performance in most applications, due to an additional capacitor on the load side. Maximum leakage current,each line-to-ground @ 120 VAC 60 Hz: @ 250 VAC 50 Hz: Hipot rating (one minute): line-to-ground line-to-line Operating frequency: Rated voltage (max.): Minimum insertion loss in dB: Line-to-ground in 50 ohm circuit .22 mA .38 mA 1500 VAC 1450 VDC 50/60 Hz 250 VAC Current Rating .15 Frequency-MHz .5 1 5 10 30 01A 03A 06A 10A 25 20 15 7 35 30 22 14 50 48 45 39 50 50 50 48 40 37 25 20 50 47 40 35 Line-to-line in 50 ohm circuit Electrical Schematic LINE Current Rating LOAD Resistor location for reference only. Frequency-MHz .5 1 5 10 20 30 EC1, EC2, EC8 01A 5 03A 5 06A 10 10A 10 35 25 10 10 50 45 40 27 60 60 65 65 60 55 60 56 40 34 40 38 40 34 40 38 EC4 01A 03A 06A 35 30 10 50 45 40 60 60 65 60 55 60 33 34 33 33 34 33 .15 5 5 10 Line Cord Line Cord No. GA400: 71/2 foot, 3-conductor line cord to mate with EC series. 30 Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com CORCOM Product Guide High Performance Compact RFI Power Line Filters with IEC Connectors (Continued) EC Series Case Dimensions EC1 A Part No. (max) 2.62 66.5 1.97 50.0 1.97 50.0 1.98 50.3 2.62 66.5 1.97 50.0 1.97 50.0 1.98 50.3 2.62 66.5 1.97 50.0 1.97 50.0 1.98 50.3 2.62 66.5 1EC1 1EC2 1EC4 EC2 1EC8 C 3EC1 .65 Max. 16.5 D E A Typical dimensions: Terminals: .250 [6.35] (3) Slot: .07 x .16 [1.8 x 4.1] B Holes: .07 [1.8] Dia.(2) 3EC2 3EC4 3EC8 6EC1 EC4 6EC2 C E A Blue D Green/Yellow Brown 6EC4 B F 6EC8 10EC1 B (max) C (max) 1.19 30.2 1.19 30.2 1.19 30.2 1.19 30.2 1.19 30.2 1.19 30.2 1.19 30.2 1.19 30.2 1.19 30.2 1.19 30.2 1.19 30.2 1.19 30.2 1.19 30.2 0.81 20.6 0.85 21.6 0.85 21.6 0.81 20.6 0.81 20.6 0.85 21.6 0.85 21.6 0.81 20.6 0.81 20.6 0.85 21.6 0.85 21.6 0.81 20.6 0.81 20.6 D ± .015 ± .38 1.575 40.01 1.575 40.01 1.575 40.01 1.575 40.01 1.575 40.01 1.575 40.01 1.575 40.01 1.575 40.01 1.575 40.01 1.575 40.01 1.575 40.01 1.575 40.01 1.575 40.01 E (max) F (ref) 1.98 50.3 1.98 50.3 1.98 50.3 1.98 50.3 1.98 50.3 1.98 50.3 1.98 50.3 1.98 50.3 1.98 50.3 1.98 50.3 1.98 50.3 1.98 50.3 1.98 50.3 — RFI Power Line Filters Case Styles — .295 7.5 .295 7.5 — — .295 7.5 .295 7.5 — — .295 7.5 .295 7.5 — Part Numbers F 06EC1 06EC2 06EC4 06EC8 10EC1 1EC1 1EC2 1EC4 1EC8 3EC1 3EC2 3EC4 3EC8 Line Cord No. Insulating Boot No. EC8 GA400 FA601 Recommended Panel Cutouts .820 20.8 1.200 30.48 Typical dimensions: Wire Leads: 4.0 [101.6] Min. 18 AWG Mounting holes: .132 [3.35] Dia. (2) 1.575 40.01 Panel Cutout (front mount) .900 22.9 .140 Dia. (2) 3.56 .062 R 1.58 1.200 30.48 1.575 40.01 Panel Cutout (back mount) Tolerance ±.005 [0.13] .140 Dia. (2) 3.56 .234 R 5.94 Tolerance ±.005 [0.13] Note 1: EC1 and EC8 allow front or back mounting. Note 2: EC2 and EC4 allow back mounting only. 31 Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com