MA-COM 60DCB6F

CORCOM Product Guide
RFI Power Line Filters for DC Applications
DC Series
EN
60 950
UL Recognized
CSA Certified
TUV Approved
DC
Specifications
Hipot rating (one minute):
line-to-ground
line-to-line
DC Series
2250 VDC
1450 VDC
Operating Voltage (max):
The DC series filters were designed as general purpose line filters
for DC applications. They are available with or without circuit
breakers for extra protection. They are available with feed-through
capacitors for added high frequency performance. The DC series
is designed to comply with UL 1283, CSA 22.2 No. 8 and
EN60950.
The DC series was developed in response to the increasing
demand for DC filtering in the telecom-datacom market. These
filters are generally used in central office equipment like switches,
routers, and hubs to clean up the 48 VDC power, but are not
exclusive to that equipment. They can also be used at the primary
input of the DC power supply. The DC Series is available in both a
flange mount (DCF) and bulkhead mount (DCB) configuration.
Circuit Breaker Features (B Suffix)
• always hold 100% of rated current independent of ambient
temperature (minimize nuisance tripping)
• Always trip at 125% of rated current independent of ambient
temperature
• Can be combined with feed through capacitor in bulk head
mount (DCB prefix) for high performance applications (BF
Suffix)
Feed Through Capacitor for High Performance (F Suffix)
• High performance results out to 3Ghz
• Available only in bulk head (DCB prefix ) configuration only
• Can be combined with circuit breaker feature (BF Suffix)
Electrical Schematics
Standard Performance Version
Note 2
Note 3
LOAD
LINE
Note 1
Note 1
Note 4
High Frequency Performance Version
Note 2
LOAD
LINE
Note 1
Note 3
Note 4
150
Resistor location for reference only.
Note 1: Depicts redundant style 6 terminals.
Note 2: Depicts optional circuit breaker.
Note 3: For 100 & 125A versions delete second coil.
Note 4: Depicts style 10 terminal versions which have separate ground stud.
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Operating Ambient Temperature Range:
(@ rated current Ir)
80 VDC
-10˚C to +55˚C
In an ambient, Ta, higher than +55˚C, the maximum
85 - Ta
operating current, Io, is as follows: Io = Ir
30
Minimum insertion loss in dB:
Standard Performance
Line-to-ground in 50 ohm circuit
Current
Frequency-MHz
Rating .01 .05 .1 .15 .5
1
3
15A
1
12 20 41 45 61
30A
4
15 23 47 59 64
60A
9 17 38 40 59
100A
10 18 38 39 53
125A
12 18 30 32 44
Line-to-line in 50 ohm circuit
Current
Frequency-MHz
Rating .01 .05 .1 .15 .5
1
3
15A
7 22 27 30 30 36 56
7 22 28 31 32 59 56
30A
60A
15 30 36 40 40 35 60
100A
14 29 35 39 33 30 53
14 24 35 39 40 28 53
125A
5
63
56
50
50
49
10
47
44
39
35
29
30
39
36
34
21
18
5
49
51
51
53
60
10
38
41
39
41
42
30
31
28
32
30
33
High Frequency Performance ("F" & "BF" Styles)
Line-to-ground in 50 ohm circuit
50 300
Current
Frequency-MHz
to to
Rating .01 .05 .1 .15 .5 1 3 5 10 20 300 3000
1 12 20 41 45 55 50 45 25 50 30
15A
4 15 20 46 58 60 60 48 35 50 30
30A
60A
9 16 38 42 52 60 48 26 40 30
9 16 38 42 52 60 42 26 40 30
100A
125A
9 16 28 34 46 54 34 34 40 30
Line-to-line in 50 ohm circuit
Current
Frequency-MHz
1
3
5
10 20
Rating .01 .05 .1 .15 .5
15A
7 22 27 30 30 50 60 60 60 36
7 22 27 30 33 56 60 60 60 40
30A
15 30 36 40 37 26 46 54 48 30
60A
100A
14 29 35 39 33 30 56 53 41 30
14 29 35 39 40 28 53 60 42 33
125A
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com
CORCOM Product Guide
RFI Power Line Filters for DC Applications (Continued)
DC Series
Cutout Dimensions
Recommended Panel Cutouts
DCB6(F) & DCB10(F)
DCB6(F) & DCB10(F)
(Viewed from filter side)
Part No.
15DCB6(F)
30DCB6(F)
15DCB10(F)
30DCB10(F)
60DCB6(F)
60DCB10(F)
100DCB6(F)
125DCB6(F)
100DCB10(F)
125DCB10(F)
A
1.375
34.93
1.250
31.75
1.375
34.93
1.674
42.52
1.700
43.18
1.954
49.63
2.250
57.15
B
1.249
31.72
1.000
25.40
1.249
31.72
1.010
25.65
1.549
39.34
1.500
38.10
1.590
40.39
C
3.472
88.19
3.472
88.19
3.472
88.19
3.443
87.45
3.472
88.19
2.830
71.20
2.725
69.22
Holes: .157 [3.99] Dia. (4)
See case dimensions for
spacing.
C
B
Tolerance: ±.005/±.13
A
DCB6B(F) & DCB10B(F) – 15 to 60 Ampss
(Viewed from filter side)
D
C
Holes: .157 [3.99] Dia. (4)
See case dimensions for
spacing.
DCB6B(F) & DCB10B(F) – 15 to 60 Amps
B
A
1.50
38.10
1.50
38.10
1.50
38.10
1.50
38.10
1.50
38.10
1.50
38.10
B
0.781
19.84
0.781
19.84
0.781
19.84
0.781
19.84
0.781
19.84
0.781
19.84
C
1.308
33.22
1.308
33.22
1.308
33.22
1.308
33.22
1.308
33.22
1.308
33.22
D
3.472
88.19
3.472
88.19
3.472
88.19
3.472
88.19
3.443
87.45
3.472
88.19
E
1.375
34.93
1.250
31.75
1.375
34.93
1.250
31.75
1.674
42.52
1.375
34.93
F
1.249
31.72
1.000
25.40
1.249
31.72
1.0
25.40
1.010
25.65
1.249
31.72
F
Tolerance: ±.005/±.13
E
A
DCB6B(F) & DCB10B(F) – 100 to 125 Amps
(Viewed from filter side)
125DCB10B(F)
125DCF10B
Holes: .157 [3.99] Dia. (4)
See case dimensions for
spacing.
C
1.250
31.75 .625
15.88
B
.262
6.65
Tolerance: ±.005/±.13
1.557
39.55
A
1.500 x 0.781
38.10 x 19.84
DCB6B(F) & DCB10B(F) – 100 to 125 Amps
Part No.
100DCB6B(F)
100DCF6B
125DCB6B(F)
125DCF6B
100DCB10B(F)
100DCF10B
DC Filters
Part No.
15DCB6B(F)
15DCF6B
15DCB10B(F)
15DCF10B
30DCB6B(F)
30DCF6B
30DCB10B(F)
30DCF10B
60DCB10B(F)
60DCF10B
60DCF6B(F)
60DCF6B
A
B
C
1.700
43.18
1.549
39.34
4.222
107.23
1.954
49.63
2.250
57.15
2.250
57.15
1.50
38.10
1.590
40.39
1.590
40.39
4.295
109.09
4.147
105.33
2.725
105.33
Part Numbers
** All cutout dimensions ± .005 [±.13]
High Performance
Standard Performance
15DCF6
30DCF6
60DCF6
100DCF6
125DCF6
15DCF6B
30DCF6B
60DCF6B
100DCF6B
125DCF6B
15DCB6
30DCB6
60DCB6
100DCB6
125DCB6
15DCB6B
30DCB6B
60DCB6B
100DCB6B
125DCB6B
15DCF10
30DCF10
60DCF10
100DCF10
125DCF10
15DCF10B
30DCF10B
60DCF10B
100DCF10B
125DCF10B
15DCB10
30DCB10
60DCB10
100DCB10
125DCB10
15DCB10B
30DCB10B
60DCB10B
100DCB10B
125DCB10B
15DCB10F
30DCB10F
60DCB10F
100DCB10F
125DCB10F
15DCB6BF
30DCB6BF
60DCB6BF
100DCB6BF
125DCB6BF
15DCB10BF
30DCB10BF
60DCB10BF
100DCB10BF
125DCB10BF
15DCB6F
30DCB6F
60DCB6F
100DCB6F
125DCB6F
151
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com
CORCOM Product Guide
RFI Power Line Filters for DC Applications (Continued)
DC Series
DCB10 & DCB10B (60 to 125 Amp)
Case Styles
A
E
C
DCB6 & DCB6B
C
F
A
E
RTN
L
O
A
D
L
O
A
D
ON
OFF
L
I
N
E
L
I
N
E
B
VDC
D
OFF
B D
RTN
VDC
RTN
-VDC
VDC
RTN
ON
-VDC
RTN
F
Tapped insert: 6-32 (4)
Note: Delete circuit breaker for DCB10 models
Tapped insert: 6-32 (4)
Note: Delete circuit breaker for DCB6 models.
DCF6
DCF10 (15 & 30 Amp)
A
E
B
L
I
N
E
D
A
E
C
L
O
A
D
RTN
B
RTN
-VDC
RTN
RTN
L
I
N
E
D
-VDC
C
L
O
A
D
-VDC
-VDC
F
Typical dimensions:
Mounting Slots: .260 x .39 [6.6 x 9.9] (4)
Mounting Holes: .203x.156 [5.2 x 4.0] (4)
Note: 15A & 30A versions come with mounting holes in place of mounting slots.
F
Typical dimensions:
Mounting Holes: .156 x .203 [4.0 x 5.2] Dia. (4)
DCF10 (60 to 126 Amps)
DCF6B
C
A
E
A
E
C
RTN
-VDC
D
B
OFF
L
I
N
E
L
O
A
D
RTN
B
D
-VDC
RTN
L
I
N
E
L
O
A
D
RTN
-VDC
ON
-VDC
Tapped insert: 6-32 (4)
F
F
Typical dimensions:
Mounting Slots: .260 x .39 [6.6 x 9.9] (4)
Typical dimensions:
Mounting Slots: .260 x .39 [6.6 x 9.9] (4)
DCF10B (15 & 30 Amp)
DCB10 & DCB10B (15 & 30 Amp)
C
A
E
A
E
C
RTN
RTN
-VDC
L
O
A
D
D
B
L
I
N
E
L
O
A
D
RTN
ON
OFF
L
I
N
E
OFF
B
D
-VDC
RTN
ON
-VDC
-VDC
F
Tapped insert: 6-32 (4)
Tapped insert: 6-32 (4)
Note: Delete circuit breaker for DCB10 models.
F
Typical dimensions:
Mounting Slots: .260 x .39 [6.6 x 9.9] (4)
152
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com
CORCOM Product Guide
RFI Power Line Filters for DC Applications (Continued)
DC Series
Case Styles (continued)
Case Dimensions (cont'd)
Part
Number
DCF10B (60 to 125 Amps)
C
A
E
OFF
L
O
A
D
RTN
ON
Tapped insert: 6-32 (4)
F
Typical dimensions:
Mounting Slots: .260 x .39 [6.6 x 9.9] (4)
Case Dimensions
A
B
C
(max) (max) (max)
15DCB6(F)
5.69
144.5
7.69
195.3
5.06
128.5
7.06
179.3
5.33
135.4
7.69
195.3
4.75
120.7
7.06
179.3
7.69
195.3
8.69
220.7
7.06
179.3
8.06
204.7
6.19
157.2
8.69
220.73
5.56
141.2
8.06
204.7
8.69
220.73
10.69
271.5
7.56
192.0
10.69
271.5
15DCB6B(F)
15DCB10(F)
15DCB10B(F)
15DCF6
15DCF6B(F)
15DCF10
15DCF10B(F)
30DCB6(F)
30DCB6B(F)
30DCB10(F)
30DCB10B(F)
30DCF6
30DCF6B
30DCF10
30DCF10B
60DCB6(F)
60DCB6B(F)
60DCF6
60DCF6B
D
*
E
(max)
F
*
1.48
4.50
4.06 0.950
37.6 114.3 103.1 24.13
1.48
4.50
6.06 0.950
37.6 114.3 153.9 24.13
1.48
4.50
4.06 0.950
37.6 114.3 103.1 24.13
1.48
4.50
6.06 0.950
37.6 114.3 153.9 24.13
1.78 2.677
3.70
2.00
45.2
68.0
94.0 50.80
1.48 5.740
6.06
3.52
37.6 145.8 153.9 89.41
1.78 2.677
3.70
2.0
45.2
68.0
94.0
50.8
1.48 5.740
6.06 3.520
37.6 145.80 153.9 89.41
1.48
4.50
6.06
0.95
37.6 114.3 153.9 24.13
1.48
4.50
7.06
0.95
37.6 114.3 179.3 24.13
1.48
4.50
6.06
0.95
37.6 114.3 153.9 24.13
1.48
4.50
7.06
0.95
37.6 114.3 179.3 24.13
2.18
3.50
4.56
2.00
55.4
88.9
115.8 50.8
1.48
5.74
7.06
4.52
37.6 145.8 179.3 114.81
2.18
3.5
4.56
2.0
55.4
88.9
115.8 50.8
7.06
4.52
5.74
1.48
37.6 145.8 179.3 114.81
1.48
4.50
7.06
0.95
37.6 114.3 179.3 24.13
1.48
4.50
9.06
0.95
37.6 114.3 230.1 24.13
2.55
4.92
5.94 2.756
64.8 124.97 150.9 70.0
6.52
9.06
5.74
1.48
37.6 145.8 230.1 165.61
B
C
(max) (max)
5.48
139.2
5.06
128.5
5.06
128.5
6.06
153.9
5.06
128.5
6.06
153.9
6.30
160.0
6.06
153.9
6.30
160.0
6.06
153.9
5.06
128.5
6.06
153.9
5.06
128.5
6.06
153.9
6.30
160.0
6.06
153.9
6.30
160.0
6.06
153.9
2.55
64.8
1.48
37.6
1.78
45.2
1.78
45.2
1.78
45.2
1.78
45.2
2.52
64.0
1.78
45.2
2.52
64.0
1.78
45.2
1.78
45.2
1.78
45.2
1.78
45.2
1.78
45.2
2.52
64.0
1.78
45.2
2.52
64.0
1.78
45.2
D
*
E
(max)
F
*
4.92
124.97
5.74
145.8
4.50
114.3
5.50
139.7
4.50
114.3
5.50
139.7
5.70
144.78
6.74
171.2
5.70
144.78
6.74
171.2
4.50
114.3
5.50
139.7
4.50
114.30
5.50
139.7
5.70
144.78
6.74
171.2
5.70
144.78
6.74
171.2
5.94
150.9
9.06
230.1
8.06
204.7
10.06
255.5
8.06
204.7
10.06
255.5
8.46
214.9
10.06
255.5
8.46
214.9
10.06
255.5
8.06
204.7
10.06
255.5
8.06
204.7
10.06
255.5
8.46
214.9
10.06
255.5
8.46
214.9
10.06
255.5
2.576
65.43
6.52
165.61
1.25
31.75
1.25
31.75
1.25
31.75
1.25
31.75
4.52
114.81
7.52
191.01
4.52
114.81
7.52
191.01
1.25
31.75
1.25
31.75
1.25
31.75
1.25
31.75
4.52
114.81
7.52
191.01
4.52
114.81
7.52
191.01
DC Filters
Part
Number
5.06
128.5
5.06
128.5
5.06
128.5
5.06
128.5
3.10
78.7
5.06
128.5
3.10
78.7
5.06
128.5
5.06
128.5
5.06
128.5
5.06
128.5
5.06
128.5
3.96
100.6
5.0
127.0
3.96
100.58
5.06
128.52
5.06
128.52
5.06
128.52
5.48
139.2
5.06
128.52
8.56
217.4
11.75
60DCF10B
298.5
10.31
100DCB6(F)
261.9
100DCB6B(F) 12.31
312.7
11.13
100DCB10(F)
282.6
100DCB10B(F) 13.13
333.5
10.60
100DCF6
269.2
12.31
100DCF6B
312.7
11.50
100DCF10
292.1
13.13
100DCF10B
333.5
10.31
125DCB6(F)
261.9
125DCB6B(F) 12.31
312.7
11.50
125DCB10(F)
292.1
125DCB10B(F) 13.50
342.9
10.60
125DCF6
269.2
12.31
125DCF6B
312.7
11.86
125DCF10
301.2
13.50
125DCF10B
342.9
60DCF10
VDC
RTN
VDC
L
I
N
E
D
B
A
(max)
* ±.020 [±.51]
Terminations
Style 6 (15, 30 & 60A)
Style 6 (100 & 125A)
Supplied with #10-32 redundant
studs - 0.625 [15.88] spacing like
polarity, 0.750 [19.05] spacing
opposing polarity.
Torque Spec: 27±3 in-lb.
Supplied with 1/4-20 redundant
studs - 0.750 [19.05] spacing like
polarity.1.000 [25.4] spacing
opposing polarity.
Torque Spec: 45±2 in-lb.
Style 10 (15 & 30A)
Style 10 (60A)
Phoenix Contact
Part No. VDFK4
Accepts 12 AWG stranded wire
Wire Strip Length: 0.315 [8.0]
Torque Spec: 5.5 - 7.0 in-lb.
Ground Stud 8-32
Phoenix Contact
Part No. HDFK 16-VP
Accepts 6 AWG stranded wire
Wire Strip Length: 0.630 [16.0]
Torque Spec: 17.7 - 21.2 in-lb.
Ground Stud 10-32
Style 10 (100A)
Style 10 (125A)
Phoenix Contact
Phoenix Contact
Part No. HDFK 25-VP
Accepts 4 AWG stranded wire
Wire Strip Length: 0.748 [19.0]
Torque Spec: 35.4 - 39.9 in-lb.
Ground Stud 1/4 - 20
Part No. HDFK-50-VP
Accepts 1 AWG stranded wire
Wire Strip Length: 0.945 [24.0]
Torque Spec: 35.4 - 39.9 in-lb.
Ground Stud 1/4 - 20
153
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023