VISHAY HFA15TB60PBF

HFA15TB60PbF/HFA15TB60-1PbF
Vishay High Power Products
HEXFRED®
Ultrafast Soft Recovery Diode, 15 A
FEATURES
HFA15TB60PbF
•
•
•
•
•
•
•
HFA15TB60-1PbF
Ultrafast recovery
Ultrasoft recovery
Very low IRRM
Very low Qrr
Specified at operating conditions
Lead (Pb)-free
Designed and qualified for industrial level
Available
RoHS*
COMPLIANT
BENEFITS
Base
cathode
2
1
Cathode
3
Anode
TO-220AC
•
•
•
•
•
2
1
N/C
3
Anode
DESCRIPTION
HFA15TB60 is a state of the art ultrafast recovery diode.
Employing the latest in epitaxial construction and advanced
processing techniques it features a superb combination of
characteristics which result in performance which is
unsurpassed by any rectifier previously available. With basic
ratings of 600 V and 15 A continuous current, the
HFA15TB60 is especially well suited for use as the
companion diode for IGBTs and MOSFETs. In addition to
ultrafast recovery time, the HEXFRED® product line features
extremely low values of peak recovery current (IRRM) and
does not exhibit any tendency to “snap-off” during the tb
portion of recovery. The HEXFRED features combine to offer
designers a rectifier with lower noise and significantly lower
switching losses in both the diode and the switching
transistor. These HEXFRED advantages can help to
significantly reduce snubbing, component count and
heatsink sizes. The HEXFRED HFA15TB60 is ideally suited
for applications in power supplies and power conversion
systems (such as inverters), motor drives, and many other
similar applications where high speed, high efficiency is
needed.
TO-262
PRODUCT SUMMARY
VR
600 V
VF at 15 A at 25 °C
1.7 V
IF(AV)
15 A
trr (typical)
19 ns
TJ (maximum)
150 °C
Qrr
84 nC
dI(rec)M/dt
188 A/µs
Reduced RFI and EMI
Reduced power loss in diode and switching transistor
Higher frequency operation
Reduced snubbing
Reduced parts count
ABSOLUTE MAXIMUM RATINGS
PARAMETER
SYMBOL
Cathode to anode voltage
TEST CONDITIONS
VR
Maximum continuous forward current
IF
Single pulse forward current
IFSM
Maximum repetitive forward current
IFRM
Maximum power dissipation
PD
Operating junction and storage temperature range
TC = 100 °C
VALUES
UNITS
600
V
15
150
A
60
TC = 25 °C
74
TC = 100 °C
29
TJ, TStg
- 55 to + 150
W
°C
* Pb containing terminations are not RoHS compliant, exemptions may apply
Document Number: 94053
Revision: 28-Jul-08
For technical questions, contact: [email protected]
www.vishay.com
1
HFA15TB60PbF/HFA15TB60-1PbF
Vishay High Power Products
HEXFRED®
Ultrafast Soft Recovery Diode, 15 A
ELECTRICAL SPECIFICATIONS (TJ = 25 °C unless otherwise specified)
PARAMETER
SYMBOL
TEST CONDITIONS
Cathode to anode
breakdown voltage
VBR
IR = 100 µA
Maximum forward voltage
VFM
IF = 30 A
IF = 15 A
See fig. 1
MIN.
TYP.
MAX.
600
-
-
-
1.3
1.7
-
1.5
2.0
UNITS
V
IF = 15 A, TJ = 125 °C
-
1.2
1.6
VR = VR rated
-
1.0
10
-
400
1000
-
25
50
pF
-
8.0
-
nH
UNITS
Maximum reverse
leakage current
IRM
Junction capacitance
CT
VR = 200 V
Series inductance
LS
Measured lead to lead 5 mm from package body
TJ = 125 °C, VR = 0.8 x VR rated
See fig. 2
See fig. 3
µA
DYNAMIC RECOVERY CHARACTERISTICS (TJ = 25 °C unless otherwise specified)
PARAMETER
Reverse recovery time
See fig. 5
Peak recovery current
See fig. 6
Reverse recovery charge
See fig. 7
Peak rate of fall of recovery
current during tb
See fig. 8
SYMBOL
TEST CONDITIONS
trr
IF = 1.0 A, dIF/dt = 200 A/µs, VR = 30 V
MIN.
TYP.
MAX.
-
19
-
trr1
TJ = 25 °C
-
42
60
trr2
TJ = 125 °C
-
74
120
IRRM1
TJ = 25 °C
-
4.0
6.0
IRRM2
TJ = 125 °C
-
6.5
10
Qrr1
TJ = 25 °C
Qrr2
TJ = 125 °C
dI(rec)M/dt1
dI(rec)M/dt2
IF = 15 A
dIF/dt = 200 A/µs
VR = 200 V
ns
A
-
84
180
-
241
600
TJ = 25 °C
-
188
-
TJ = 125 °C
-
160
-
MIN.
TYP.
MAX.
UNITS
-
-
300
°C
-
-
1.7
nC
A/µs
THERMAL - MECHANICAL SPECIFICATIONS
PARAMETER
SYMBOL
TEST CONDITIONS
Lead temperature
Tlead
Thermal resistance,
junction to case
RthJC
Thermal resistance,
junction to ambient
RthJA
Typical socket mount
-
-
80
Thermal resistance,
case to heatsink
RthCS
Mounting surface, flat, smooth and gerased
-
0.5
-
-
2.0
-
g
-
0.07
-
oz.
6.0
(5.0)
-
12
(10)
kgf · cm
(lbf · in)
0.063" from case (1.6 mm) for 10 s
Weight
Mounting torque
Marking device
www.vishay.com
2
Case style TO-220AC
Case style TO-262
For technical questions, contact: [email protected]
K/W
HFA15TB60
HFA15TB60-1
Document Number: 94053
Revision: 28-Jul-08
HFA15TB60PbF/HFA15TB60-1PbF
100
10 000
IR - Reverse Current (µA)
IF - Instantaneous Forward Current (A)
HEXFRED®
Vishay High Power Products
Ultrafast Soft Recovery Diode, 15 A
10
TJ = 150 °C
TJ = 125 °C
TJ = 25 °C
1
1.0
TJ = 150 °C
1000
TJ = 125 °C
100
10
1
TJ = 25 °C
0.1
0.01
1.2
1.4
1.6
2.0
1.8
2.2
0
2.4
100
300
200
500
400
600
VFM - Forward Voltage Drop (V)
VR - Reverse Voltage (V)
Fig. 1 - Maximum Forward Voltage Drop vs.
Instantaneous Forward Current
Fig. 2 - Typical Reverse Current vs. Reverse Voltage
CT - Junction Capacitance (pF)
100
TJ = 25 °C
10
10
100
1000
VR - Reverse Voltage (V)
Fig. 3 - Typical Junction Capacitance vs. Reverse Voltage
ZthJC - Thermal Response
10
1
PDM
t1
D = 0.50
D = 0.20
D = 0.10
D = 0.05
D = 0.02
D = 0.01
0.1
Single pulse
(thermal response)
0.01
0.00001
0.0001
0.001
t2
Notes:
1. Duty factor D = t1/t2
2. Peak TJ = PDM x ZthJC + TC
0.01
0.1
1
t1 - Rectangular Pulse Duration (s)
Fig. 4 - Maximum Thermal Impedance ZthJC Characteristics
Document Number: 94053
Revision: 28-Jul-08
For technical questions, contact: [email protected]
www.vishay.com
3
HFA15TB60PbF/HFA15TB60-1PbF
Vishay High Power Products
HEXFRED®
Ultrafast Soft Recovery Diode, 15 A
800
100
IF = 30 A
IF = 15 A
IF = 5 A
VR = 200 V
TJ = 125 °C
TJ = 25 °C
600
Qrr (nC)
trr (ns)
80
700
60
40
500
400
IF = 30 A
IF = 15 A
IF = 5 A
300
200
20
VR = 200 V
TJ = 125 °C
TJ = 25 °C
100
0
100
0
100
1000
dIF/dt (A/µs)
Fig. 5 - Typical Reverse Recovery Time vs. dIF/dt
Fig. 7 - Typical Stored Charge vs. dIF/dt
10 000
25
15
dI(rec)M/dt (A/µs)
VR = 200 V
TJ = 125 °C
TJ = 25 °C
20
Irr (A)
1000
dIF/dt (A/µs)
IF = 30 A
IF = 15 A
IF = 5 A
10
IF = 30 A
IF = 15 A
IF = 5 A
1000
5
0
100
www.vishay.com
4
1000
VR = 200 V
TJ = 125 °C
TJ = 25 °C
100
100
1000
dIF/dt (A/µs)
dIF/dt (A/µs)
Fig. 6 - Typical Recovery Current vs. dIF/dt
Fig. 8 - Typical dI(rec)M/dt vs. dIF/dt
For technical questions, contact: [email protected]
Document Number: 94053
Revision: 28-Jul-08
HFA15TB60PbF/HFA15TB60-1PbF
HEXFRED®
Vishay High Power Products
Ultrafast Soft Recovery Diode, 15 A
VR = 200 V
0.01 Ω
L = 70 µH
D.U.T.
dIF/dt
adjust
D
IRFP250
G
S
Fig. 9 - Reverse Recovery Parameter Test Circuit
(3)
trr
IF
ta
tb
0
Qrr
(2)
IRRM
(4)
0.5 IRRM
dI(rec)M/dt (5)
0.75 IRRM
(1) dIF/dt
(1) dIF/dt - rate of change of current
through zero crossing
(2) IRRM - peak reverse recovery current
(3) trr - reverse recovery time measured
from zero crossing point of negative
going IF to point where a line passing
through 0.75 IRRM and 0.50 IRRM
extrapolated to zero current.
(4) Qrr - area under curve defined by trr
and IRRM
Qrr =
trr x IRRM
2
(5) dI(rec)M/dt - peak rate of change of
current during tb portion of trr
Fig. 10 - Reverse Recovery Waveform and Definitions
LINKS TO RELATED DOCUMENTS
Dimensions
http://www.vishay.com/doc?95261
Part marking information
http://www.vishay.com/doc?95262
Document Number: 94053
Revision: 28-Jul-08
For technical questions, contact: [email protected]
www.vishay.com
5
Legal Disclaimer Notice
Vishay
Disclaimer
All product specifications and data are subject to change without notice.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf
(collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein
or in any other disclosure relating to any product.
Vishay disclaims any and all liability arising out of the use or application of any product described herein or of any
information provided herein to the maximum extent permitted by law. The product specifications do not expand or
otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed
therein, which apply to these products.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this
document or by any conduct of Vishay.
The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications unless
otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such
applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting
from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding
products designed for such applications.
Product names and markings noted herein may be trademarks of their respective owners.
Document Number: 91000
Revision: 18-Jul-08
www.vishay.com
1