TOTAL POWER INT. T60 AC-DC 60W POWER SUPPLY .LOW COST, HIGH RELIABILITY .COMPACT SIZE, LIGHT WEIGHT .105ºC OUTPUT CAPACITOR .100% FULL LOAD BURN-IN TEST .INTERNATIONAL AC INPUT RANGE .HIGH EFFICIENCY, LOW WORKING TEMPERATURE .SOFT-START CIRCUIT, LIMITING AC SURGE CURRENT .SHORT CIRCUIT, OVERLOAD, OVER VOLTAGE PROTECTED T-60A MODEL SPECIFICATION DC OUTPUT VOLTAGE CH1 CH2 T-60B CH3 CH1 T-60C CH2 CH3 CH1 CH2 CH3 5V 12V -5V 5V 12V -12V 5V 15V -15V ±2% ±6% ±6% ±2% ±6% ±6% ±2% ±6% ±6% OUTPUT RATED CURRENT 5A 2.5A 0.5A 5A 2.5A 0.5A 5A 2A 0.5A OUTPUT CURRENT RANGE 0.5-7A 0.2-3.5A 0-1A 0.5-7A 0.2-3.5A 0-1A 0.5-7A 0.2-3A 0-1A RIPPLE & NOISE(Vp-p) 100m 100m 100m 100m 100m 100m 100m 100m 100m LINE REGULATION ±0.5% ±1% ±0.5% ±0.5% ±1% ±0.5% ±0.5% ±1% ±0.5% LOAD REGULATION ±1% ±4% ±1% ±1% ±4% ±1% ±1% ±4% ±1% OUTPUT V. TOLERANCE RATED OUTPUT POWER 57.5W EFFICIENCY DC VOLTAGE ADJ. 61W 62.5W 72% 72% 72% CH1:+10,-5% CH1:+10,-5% CH1:+10,-5% INPUT VOLTAGE RANGE 85~264VAC 47~63Hz ; 120~370VDC AC CURRENT 2A/115V 1A/230V INRUSH CURRENT COLD START 30A/115V 60A/230V LEAKAGE CURRENT <1mA/240VAC OVERLOAD PROTECTION 105%~150%/115VAC TYPE:PULSING HICCUP SHUTDOWN RESET:AUTO RECOVERY OVER VOLTAGE PROTECTION CH1:5.75~6.75V TEMP. COEFFICIENT ±0.03% / ºC (0~50ºC) ON +5V OUTPUT SETUP,RISE,HOLD UP TIME 800ms, 50ms, 10ms / 115VAC 300ms, 50ms, 80ms / 230VAC VIBRATION 10~500Hz, 2G 3AXES 10min. / 1cycle ( 1 HOUR / EACH AXES ) WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 1min. ISOLATION RESISTANCE I/P-O/P,I/P-FG,O/P-FG:500VDC / 100M Ohms WORKING TEMP., HUMIDITY -10ºC~+60ºC(REFER TO OUTPUT DERATING CURVE), 20%~90% RH STORAGE TEMP., HUMIDITY -20ºC~+85ºC, 10%~95% RH DIMENSION 159*97*38mm CASE:901 WEIGHT 0.56Kgs SAFETY STANDARDS UL1012, TUV EN60950, IEC950, UL1950 APPROVED EMC STANDARDS CISPR22(EN55022) CLASS B, IEC801-2,3,4, IEC555-2 VERIFICATION NOTE : 1.ALL PARAMETERS ARE SPECIFIED AT 230VAC INPUT, RATED LOAD, 25ºC 70% RH. AMBIENT. 2.TOLERANCE GINCLUDE SET UP TOLERANCE, LINE REGULATION, LOAD REGULATION. 3.RIPPLE & NOISE ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED WITH A 0.1uF & 47uF CAPACITOR. 4.LINE REGULATION IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD. 5.LOAD REGULATION IS MEASURED FROM 20% TO 100% RATED LOAD, AND OTHER OUTPUT AT 60% RATED LOAD 6.EACH OUTPUT PROVIDE UP TO MAXIMUM CURRENT, BUT TOTAL LOAD CAN NOT EXCEED MAX. OUTPUT POWER. 7.C23,6 MUST BE REMOVED.