MA-COM SR4M4021

SCHRACK
General Purpose Relays
Safety Relay SR4 D/M
n
4 pole safety relay with either
2 NO+2 NC or 3 NO+1 NC contacts
n
Forcibly guided contacts according to EN 50205
n
Rated current 8 A
n
Compact design & space efficient
Applications
Emergency shut-off, machine control, elevator and escalator
control, light barrier control
F0244-C
Approvals
V
REG.-Nr. 40005334, Z E214024, T968/EL 230.03/07
Technical data of approved types on request
Contact data
Contact configuration
3 NO contacts and 1 NC contact
or
2 NO contacts and 2 NC contacts
Contact set
single contact, forcibly guided
type A according to EN 50205
Type of interruption
micro disconnection
Rated voltage / max. switching voltage AC
250 / 400 VAC
Rated current
8A
Maximum breaking capacity AC
2000 VA
Contact material
AgSnO2
Minimum contact load
10 mA / 5 V
Contact resistance
w 100 mOhm / 1 A / 24 VDC
w 20 Ohm / 10 mA / 5 VDC
Rated frequency of operation with / without load
6 min-1 / 150 min-1
Contact ratings
Type
Contact Load*)
EN60947-5-1
SR4D/M 1 NO
SR4D/M 1 NO
Ambient
temp. [°C]
IEC 947-5-1 (AC15) utilization category 250 VAC / 3 A 23°C
IEC 947-5-1 (DC13) utilization category 24 VDC / 3 A 23°C
Cycles
6,050
6,050
*) load on one pole
Coil data
Rated coil voltage range DC coil
5...110 VDC
Operative range to IEC 61810
2
Coil versions, DC-coil
Coil
Rated
Operate
Release
Coil
Rated coil
code
voltage
voltage
voltage
resistance
power
VDC
VDC
VDC
Ohm
mW
005
5
3.8
0.5
31+10%
806
006
6
4.5
0.6
45+10%
800
009
9
6.8
0.9
101+10%
802
012
12
9.0
1.2
180+10%
800
015
15
11.3
1.5
281+10%
801
018
18
13.5
1.8
405+10%
800
021
21
15.8
2.1
551+10%
800
024
24
18.0
2.4
720+10%
800
036
36
27.0
3.6
1620+10%
800
040
40
30.0
4.0
2000+10%
800
048
48
36.0
4.8
2880+10%
800
060
60
45.0
6.0
4500+10%
800
085
85
63.8
8.5
9031+10%
800
110
110
82.5
11.0
15125+10%
800
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
1
Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical parameters, test conditions and
processing information only
to be used together with the
'Definitions' section in the catalogue or at schrackrelays.com
in the ‘Schrack’ section.
Specifications subject to
change.
SCHRACK
General Purpose Relays
Safety Relay SR4 D/M (Continued)
Insulation
PCB layout / terminal assignment
Dielectric strength coil-contact circuit
4000 Vrms
open contact circuit
1500 Vrms
adjacent contact circuits
2500 Vrms
Clearance / creepage coil-contact circuit
W 10 / 10 mm
adjacent contact circuits
W 3 / 3.5 mm
adjacent contact circuits (UL840)
W 1.3 / 3.5 mm
W 5.5 / 5.5 mm (in longitudinal direction)
Material group of insulation parts
IIIa
Tracking index of relay base
PTI 250
Insulation to IEC 61810-1
Type of insulation coil-contact circuit
reinforced
open contact circuit
micro disconnection
adjacent contact circuits
basic
Rated insulation voltage
250 V
Pollution degree
2
Rated voltage system
230 / 400 V
Overvoltage category
III
Insulation to EN 50178
Type of insulation coil-contact circuit
reinforced
adjacent contact circuits
basic
reinforced (in longitudinal direction)
Bottom view on solder pins
Other data
3 NO and 1 NC contacts
S0413-BC
2 NO and 2 NC contacts
S0413-BB
Mechanical endurance
10x106 cycles
Material
RoHS - Directive 2002/95/EC
compliant as per product date code 0407
Environment
Ambient temperature range
-25...+70°C
Vibration resistance (function) NO / NC contact > 10 / 2 g, 10....200 Hz
Shock resistance (function) NO / NC contact > 10 / 2 g, 11 ms half sine
Category of protection
RT III1)
Processing
Resistance to soldering heat
260°C / 5 s
Relay weight
16 g
Packaging unit
10 pcs
1)
S0413-BA
please contact technical support for washing parameters
Dimensions
S0412-BH
Product key
Typical product key
SR4
D
4
012
Type
SR4 Safety Relay SR4 D/M
Contact configuration
D 2 NO + 2 NC contacts (2 form A + 2 form B)
M 3 NO + 1 NC contacts (3 form A + 1 form B)
Contact material
4 AgSnO2
Coil
Coil code = rated coil voltage (e.g. 024=24 VDC)
Other types on request
2
Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical parameters, test conditions and
processing information only
to be used together with the
'Definitions' section in the catalogue or at schrackrelays.com
in the ‘Schrack’ section.
Specifications subject to
change.
SCHRACK
General Purpose Relays
Safety Relay SR4 D/M (Continued)
Product key
SR4D4005
SR4D4006
SR4D4009
SR4D4012
SR4D4018
SR4D4021
SR4D4024
SR4D4036
SR4D4040
SR4D4048
SR4D4060
SR4D4085
SR4D4110
SR4M4005
SR4M4006
SR4M4009
SR4M4012
SR4M4018
SR4M4021
SR4M4024
SR4M4036
SR4M4040
SR4M4048
SR4M4060
SR4M4085
SR4M4110
Type
4 pole
safety relay
Contact configuration
2 NO + 2 NC
contacts
Contact material
AgSnO2
3 NO + 1 NC
contacts
Coil
5 VDC
6 VDC
9 VDC
12 VDC
18 VDC
21 VDC
24 VDC
36 VDC
40 VDC
48 VDC
60 VDC
85 VDC
110 VDC
5 VDC
6 VDC
9 VDC
12 VDC
18 VDC
21 VDC
24 VDC
36 VDC
40 VDC
48 VDC
60 VDC
85 VDC
110 VDC
Part number
7-1415054-1
8-1415054-1
9-1415054-1
1415055-1
1-1415055-1
2-1415055-1
3-1415055-1
4-1415055-1
5-1415055-1
6-1415055-1
7-1415055-1
8-1415055-1
9-1415055-1
5-1415053-1
6-1415053-1
7-1415053-1
8-1415053-1
9-1415053-1
1415054-1
4-1415053-1
1-1415054-1
2-1415054-1
3-1415054-1
4-1415054-1
5-1415054-1
6-1415054-1
3
Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical parameters, test conditions and
processing information only
to be used together with the
'Definitions' section in the catalogue or at schrackrelays.com
in the ‘Schrack’ section.
Specifications subject to
change.