200 WATTS POWER FACTOR CORRECTED MULTIPLE OUTPUT PCI-200 STANDARD PCI SERIES Featuring: • Dual main outputs • Flexible ratings • 5 V “Keep Alive” bias output • Universal AC input • 0.99 typical power factor • Remote sense on main outputs • DC power good and AC power fail • True remote inhibit • High-current bus bars MODEL PCI 204-1203 PWR 200 OUTPUT #1 +5V @ 30A* OUTPUT #2 +3.3V @ 20A* OUTPUT #3 +12V @ 5A** OUTPUT #4 -12V @ 5A** * Combined rating, sum of output currents of outputs #1 & #2 equals 30 A. ** Combined rating, sum of output currents of outputs #3 & #4 equals 5 A. The PCI 204 power supply series provides simultaneous high currents on both 5 V and 3.3 V outputs. The load may be shifted between outputs. For example: the PCI 204-1203 may be loaded at +5 V @ 25 A and 3.3 V @ 5 A, or 5 V @ 10 A and 3.3 V @ 20 A, or any other combination of loads within the maximum ratings. Similarly the ±12 V may be loaded in any combination not exceeding maximum ratings. The PCI series provides a single solution as system configurations proliferate, thereby reducing cycle time and cost. Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com 200 WATTS 8.09”x 5”x 2” PCI-200 PCI-200 2.0 lbs .9 kgs Dimensions: Inches Millimeters SPECIFICATIONS: INPUT AC Input: 90 - 264 Vac continuous range, 47 to 63 Hz. Internally fused for 4 A. Power Factor: 0.99 typical at full load. Meets EN61000-3-2. Inrush: Cold start AC current limited to 16 A. at 115 Vac, 30 A. at 230 Vac. Limited by thermistor. Brownout Protection: Holds regulation to 85 Vac. Holdup Time: 16 ms minimum. Efficiency: 70% typical at full load nominal line. AC Power Fail: Provides TTL “0” 5 ms before output goes out of regulation band upon loss of input power. OUTPUT Adjustability: + / - 5% Line & Load Reg: + /- 1% over AC input range and minimum to maximum load. Minimum Load: 10% on main to insure regulation of aux outputs. Ripple & Noise: Less than 1% p-p or 100 mV, which ever greater. Remote Sense: (Outputs #1, and #2) Compensates for 250 mv total line drop. Open sense lead protection. Temperature Coefficient: 0.02% per degree C. Transient Response: Output voltage returns to within 1% in less than 500 µs for a 25% load change. Peak transient does not exceed 3%. Overload Protection: All outputs are protected against overload and short circuit. Automatic recovery upon removal of fault. Overvoltage Protection: Output #1 protected against power supply induced overvoltage condition. Factory set to 136% maximum. Other outputs inherently voltage limited by design. Remote Inhibit: Contact closure to negative sense line or a TTL “0” (open collector) turns off DC outputs. Reverse Voltage: Protected against reversed voltage up to supply current ratings. DC Power Good: Provides TTL “0” (open collector) when output #1 above 4.6V. Aux Output: Provides 5 V + / - 5% @ 100 ma bias output, which is present whenever power supply has input power. ENVIRONMENTAL Thermal Protection: Shuts down power supply if heatsink temperature exceeds 82° C. Temperature Range: 0° C to 50° C at full ratings. Safety Agencies: Approved to UL 1950; CSA 22.2 # 234 (950); TUV EN60950, Class 1 SELV; CE 72/23/EEC/93/68EEC (low voltage directive). Output Isolation: Isolated form ground 50Vdc. Conducted RFI: Meets FCC part 15, Subpart J class A, and CISPR 22 class A. Cooling: 30 CFM required to achieve full ratings. AC INPUT (90 - 264 VAC Continuous Range) FUNCTION J1-17 115 VAC Neutral 230 VAC Line 2 J1-15 Line Line 1 CONNECTOR AMP p/n 1-60445-7 mates with: AMP p/n 1-640426-7 DC OUTPUT FUNCTION Output #1 Output #2 Output #3 Output #4 LOCATION Terminal marked +5 Terminal marked RTN Terminal marked +3.3 J1-5 J1-6 J1-7 NOTES CONNECTOR Main Output RTN (com) +3.3 Output + Output +/- RTN (com) - Output Bus bar #8-32 screw Bus bar #8-32 screw Bus bar #8-32 screw AMP p/n 1-6044-7 mates with: NOTES +5 sense +3.3 sense +3.3 sense rtn +5 sense rtn Reference to com Reference to com Reference to com 5V aux bias 5V aux bias rtn CONNECTOR See above STATUS AND CONTROL FUNCTION Remote Sense DC Power Good AC Power Fail Inhibit Aux output (+) Aux output (-) LOCATION J1-1 J1-2 J1-3 J1-4 J1-8 J1-9 J1-10 J1-11 J1-12 OPTIONS: Consult factory for available options. Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com