SLPOWER PCI-200

200 WATTS
POWER FACTOR CORRECTED
MULTIPLE OUTPUT
PCI-200
STANDARD PCI SERIES
Featuring:
• Dual main outputs
• Flexible ratings
• 5 V “Keep Alive” bias output
• Universal AC input
• 0.99 typical power factor
• Remote sense on main outputs
• DC power good and AC power fail
• True remote inhibit
• High-current bus bars
MODEL
PCI 204-1203
PWR
200
OUTPUT #1
+5V @ 30A*
OUTPUT #2
+3.3V @ 20A*
OUTPUT #3
+12V @ 5A**
OUTPUT #4
-12V @ 5A**
* Combined rating, sum of output currents of outputs #1 & #2 equals 30 A.
** Combined rating, sum of output currents of outputs #3 & #4 equals 5 A.
The PCI 204 power supply series
provides simultaneous high currents
on both 5 V and 3.3 V outputs. The
load may be shifted between outputs.
For example: the PCI 204-1203 may
be loaded at +5 V @ 25 A and 3.3 V
@ 5 A, or 5 V @ 10 A and 3.3 V @
20 A, or any other combination of
loads within the maximum ratings.
Similarly the ±12 V may be loaded
in any combination not exceeding
maximum ratings.
The PCI series provides a single
solution as system configurations
proliferate, thereby reducing cycle
time and cost.
Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com
200 WATTS
8.09”x 5”x 2”
PCI-200
PCI-200
2.0 lbs .9 kgs
Dimensions:
Inches
Millimeters
SPECIFICATIONS:
INPUT
AC Input: 90 - 264 Vac continuous range, 47 to 63 Hz. Internally fused for 4 A.
Power Factor: 0.99 typical at full load. Meets EN61000-3-2.
Inrush: Cold start AC current limited to 16 A. at 115 Vac, 30 A. at 230 Vac. Limited by
thermistor.
Brownout Protection: Holds regulation to 85 Vac.
Holdup Time: 16 ms minimum.
Efficiency: 70% typical at full load nominal line.
AC Power Fail: Provides TTL “0” 5 ms before output goes out of regulation band
upon loss of input power.
OUTPUT
Adjustability: + / - 5%
Line & Load Reg: + /- 1% over AC input range and minimum to maximum load.
Minimum Load: 10% on main to insure regulation of aux outputs.
Ripple & Noise: Less than 1% p-p or 100 mV, which ever greater.
Remote Sense: (Outputs #1, and #2) Compensates for 250 mv total line drop. Open sense
lead protection.
Temperature Coefficient: 0.02% per degree C.
Transient Response: Output voltage returns to within 1% in less than 500 µs for a
25% load change. Peak transient does not exceed 3%.
Overload Protection: All outputs are protected against overload and short circuit.
Automatic recovery upon removal of fault.
Overvoltage Protection: Output #1 protected against power supply induced overvoltage
condition. Factory set to 136% maximum. Other outputs inherently voltage
limited by design.
Remote Inhibit: Contact closure to negative sense line or a TTL “0” (open collector)
turns off DC outputs.
Reverse Voltage: Protected against reversed voltage up to supply current ratings.
DC Power Good: Provides TTL “0” (open collector) when output #1 above 4.6V.
Aux Output: Provides 5 V + / - 5% @ 100 ma bias output, which is present whenever
power supply has input power.
ENVIRONMENTAL
Thermal Protection: Shuts down power supply if heatsink temperature exceeds 82° C.
Temperature Range: 0° C to 50° C at full ratings.
Safety Agencies: Approved to UL 1950; CSA 22.2 # 234 (950); TUV EN60950,
Class 1 SELV; CE 72/23/EEC/93/68EEC (low voltage directive).
Output Isolation: Isolated form ground 50Vdc.
Conducted RFI: Meets FCC part 15, Subpart J class A, and CISPR 22 class A.
Cooling: 30 CFM required to achieve full ratings.
AC INPUT (90 - 264 VAC Continuous Range)
FUNCTION
J1-17
115 VAC
Neutral
230 VAC
Line 2
J1-15
Line
Line 1
CONNECTOR
AMP p/n 1-60445-7
mates with:
AMP p/n 1-640426-7
DC OUTPUT
FUNCTION
Output #1
Output #2
Output #3
Output #4
LOCATION
Terminal marked +5
Terminal marked RTN
Terminal marked +3.3
J1-5
J1-6
J1-7
NOTES
CONNECTOR
Main Output
RTN (com)
+3.3 Output
+ Output
+/- RTN (com)
- Output
Bus bar #8-32 screw
Bus bar #8-32 screw
Bus bar #8-32 screw
AMP p/n 1-6044-7
mates with:
NOTES
+5 sense
+3.3 sense
+3.3 sense rtn
+5 sense rtn
Reference to com
Reference to com
Reference to com
5V aux bias
5V aux bias rtn
CONNECTOR
See above
STATUS AND CONTROL
FUNCTION
Remote Sense
DC Power Good
AC Power Fail
Inhibit
Aux output (+)
Aux output (-)
LOCATION
J1-1
J1-2
J1-3
J1-4
J1-8
J1-9
J1-10
J1-11
J1-12
OPTIONS:
Consult factory for available options.
Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com