1000 WATTS POWER FACTOR CORRECTED MULTIPLE OUTPUT, FORCED CURRENT SHARING NMX-1000 Featuring: • Forced current sharing for N +1 redundancy • Remote sense on outputs #1, 2 and 3 • “Zero wire” slope program current sharing on outputs #2 and 3 for redundancy • Universal AC input • 0.99 power factor • Mag-Amp regulators eliminate interaction between logic and auxiliary outputs • Compact, low-profile package, only 12” x 8” x 3.38” • DC power good and AC power fail signals • True remote inhibit STANDARD NMX SERIES MODEL PWR OUTPUT #1 NMX-1003-0512 NMX-1004-1203 NMX-1004-1205 NMX-1004-1212 NMX-1004-1224 NMX-1004-1512 NMX-1004-1524 1000 1000 1000 1000 1000 1000 1000 +5V +5V +5V +5V +5V +5V +5V @ @ @ @ @ @ @ 150A 150A 150A 150A 150A 150A 150A OUTPUT #2 +12V +12V +12V +12V +12V +15V +15V @ @ @ @ @ @ @ 20/30A pk 20/30A pk 20/30A pk 20/30A pk 20/30A pk 20/30A pk 20/30A pk OUTPUT #3 OUTPUT #4 -12V -12V -12V -12V -12V -15V -15V 3.3V @ 10A 5V @ 10A 12V @ 10A 24V @ 5A 12V @ 10A 24V @ 5A @ @ @ @ @ @ @ 10A 10A 10A 10A 10A 10A 10A The smallest most capable 1000 W power supply of its kind. When used with external OR-ing diodes, NMX Series power supplies can easily be configured as multiple-output, current-sharing, redundant power systems. NMX Series switching power supplies have power factor correction, 1000watt multiple output, and current sharing. They are available as low-profile, selfcooled modules, and are designed to meet global requirements. Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com 1000 WATTS 12”x 8”x 3.38” NMX-1000 NMX-1000 10.4 lbs - 4.7 kgs Dimensions: Inches Millimeters SPECIFICATIONS: ALL MODELS INPUT AC Input: 90-264 Vac continuous range, 47 to 63 Hz. Internally fused for 20 A. Power Factor: 0.99 typical at full load. Meets EN61000-3-2. Inrush: Cold start AC current is less than 90 A at 115 Vac and 180 A at 230 Vac. Limited by thermistor. Brownout Protection: Holds regulation to 85 Vac. Holdup Time: 20 ms minimum after removal of power at full load. Efficiency: 75% typical. AC Power Fail: Provides TTL “0” 5 ms before output voltage goes out of regulation band upon loss of AC power. OUTPUT Adjustability: All outputs user adjustable ±5% minimum. Outputs #2 and 3 have factory adjustable preprogrammed slope. Line & Load Reg: Outputs #1 and 4 hold ±1% over AC input range and 0 to 100% load change. Outputs #2 and 3 hold ±2% (preprogrammed slope). Output #1 requires minimum load of 10%. Ripple & Noise: Less than 1% p-p or 100 mV, whichever is greater. Remote Sense (Outputs #1, 2, and 3): Compensates for 250 mV total line drop. Open sense lead protection. Temperature Coefficient: 0.02% per degree C. Stability: 0.1% over 8 hours after 30 minutes warm-up. Transient Response (Output #1): Output voltage returns to within 1% in less than 500 µs for a 50% load change. Peak transient does not exceed 5%. Overload Protection: All outputs are protected against overload and short circuit. Automatic recovery upon removal of fault. Overvoltage Protection (Outputs #1, 2, and 3): Protects load against power supply induced overvoltage. Trip point is factory set so that output voltage cannot exceed 136% of nominal. Peak Output Current: Dual current ratings define continuous and peak currents. The peak current shown can be delivered for a maximum period of 30 seconds. Remote Inhibit: Contact closure to the negative sense line or a TTL level “0” turns off DC outputs. DC Power Good: Provides a TTL “1” when output #1 is above 4.6 V nominal. Redundancy: External OR-ing diodes and current sharing on outputs #1, 2, and 3 provide “N+1” capability. Remote senses compensate for additional 0.6 V diode voltage drop. When the forced current sharing terminal is connected among units, current sharing remains within 10% of the unit’s full output current rating. ENVIRONMENTAL Thermal Protection: Shuts down power supply if overheated. Automatic recovery. Temperature Range: 0° to 50°C at full ratings. Safety Agencies: Most models are approved to UL1950; CSA 22.2 #234; IEC 950 and TÜV EN60950, Class 1 SELV., CE 72/23/EEC/93/68EEC (low voltage directive). Conducted RFI: Meets FCC Part 15, Subpart J, Class A; EN55022 Class B; CISPR 22 Class B. Output Isolation: Isolated from ground 50 Vdc. Reverse Voltage: Protected against reverse voltage up to supply current rating. Cooling: Self cooled with internal ball-bearing fans. Consult factory for alternative configurations. OPTIONS: Consult factory for available options. AC INPUT (90-264 VAC Continuous Range) FUNCTION TB1- (L ) TB1- (N) TB1- ( ) 115 VAC Line Neutral Safety Ground 230 VAC Line 1 Line 2 Safety Ground LOCATION Terminal marked +V Terminal marked -V J2-1, 2, 3 J2-4, 5, 6 J2-7, 8, 9 J2-4, 5, 6 J2-10, 11, 12, J2-13, 14, 15 NOTES Main output Rtn (Common) CONNECTOR Barrier strip # 6-32 screws 3/8” centers DC OUTPUT FUNCTION Output #1 Output #2 Output #3 Output #4 Rtn (Common) Rtn (Common) (+) Floating Output (-) Floating Output CONNECTOR Studs # 5/16-18 x 1” AMP # 350830-1 mates with plug housing # 350736-1 with pins STATUS AND CONTROL FUNCTION Remote Sense DC Power Good AC Power Fail Inhibit Current Share LOCATION J3-1 J3-3 J3-8 J3-7 J3-9 J3-6 J3-4 J3-5 J3-2 NOTES CONNECTOR Output #1 Sense Output #1 Sense Rtn Output #2 Sense Output #2&3Sense Rtn AMP MTA type #640456-9 pin Output #3 Sense header (locking) Reference to Common when a Sense Rtn is terminated Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com