CRYDOM HDC100A120

HDC Series
• Ratings of 120A and 160A @ 72VDC
• LED Status Indicator
• Heavy Duty Stud Terminals
• AC or DC control
• µS Turn-On and Off times
• Low On-State Voltage Drop
• PWM to 1K Hz
PRODUCT SELECTION
Control Voltage
4.5-32 Vdc
90-140 Vac
120A
160A
HDC100D120
HDC100A120
HDC100D160
HDC100A160
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage [Vdc]
Blocking Voltage [Vdc]
Rated Load Current [Arms] (2)
Minimum Load Current [mA]
Maximum Surge Current (10ms) [Adc]
Maximum Off-State Leakage Current @ Rated Voltage [mA]
Maximum On-State Voltage Drop @ Rated Current [Vdc]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum On-State Resistance @ Rated Current (RDS-ON) [mOhms]
Wire Size max (solid/stranded) [AWG/ IEC mm²]
Output Terminal Nut Torque Range [in lb (Nm)
Maximum PWM (Hz) (3)
120A
160A
7-72
100
120
2.5
360
0.15
0.52
0.42
4.32
2/0 / 67.4
225-300 (25.4-33.9)
1000
7-72
100
160
2.5
470
0.15
0.56
0.36
3.5
2/0 / 67.4
225-300 (25.4-33.9)
1000
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Must Turn-Off Voltage
Minimum Input Current @ Minimum Voltage (for on-state)
Maximum Input Current @ Maximum Voltage
Nominal Input Impedance
Maximum Turn-On Time at min voltage
Maximum Turn-On Time at max voltage
Maximum Turn-Off Time at min voltage
Maximum Turn-Off Time at max voltage
LED Status Indicator (Color)
Terminal Type / size in (mm)
GENERAL NOTES
1) All parameters at 40°C unless otherwise specified.
2) Heat sinking required, see derating curves.
3) See PWM Derating Chart.
WIRING DIAGRAM
HDCxxD
HDCxxA
4.5-32 Vdc
4.2 VDC
23 mA
45 mA
Current Regulated
90.5 µs
8.5 µs
145 µs
330 µs
Green
QC / 0.187 (4.75)
90-140 VAC
35 VAC
31 mA
33 mA
Current Regulated
6 ms
4 ms
9.2 ms
9.2 ms
Green
QC / 0.187 (4.75)
MECHANICAL SPECIFICATIONS
THERMAL DERATE INFORMATION
PWM DERATE INFORMATION
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
IEC 61000-4-2 : Electrostatic Discharge: Level 3 (Criteria A)
IEC 61000-4-4 : Electrically Fast Transients: Level 3 (Criteria A)
IEC 61000-4-5 : Electricsl Surges: Level 3 (Criteria A)
Rev. 072312
ACCESSORIES
ANNEX - ENVIROMENTAL INFORMATION