PowerPlus DC • Optically Isolated MOSFET output • Ratings from 10A to 40A @ 150 VDC and 10 & 20A @ 300 VDC • AC and DC control • Relays are easily paralleled for higher-current applications • LED Status Indicator • Optional IP20 Cover • UL Recognized, CE and RoHS Compliant • PWM to 1K HZ PRODUCT SELECTION Control Voltage 4-32 VDC 90-140 VAC 10A 20A 40A 60A 10A 20A DC200D10 DC200A10 DC200D20 DC200A20 DC200D40 DC200D60 DC400D10 DC400A10 DC400D20 AVAILABLE OPTIONS OUTPUT SPECIFICATIONS (1) Description Operating Voltage [Vdc] (2) Blocking Voltage Rated Load Current [Adc] (3) Minimum Load Current [mA] (4) Maximum Surge Current [Adc] (10ms) Maximum On-State Voltage Drop @ Rated Current [Vdc] Maximum Off-State Leakage Current @ Rated Voltage [mA] Thermal Resistance Junction to Case (Rjc) [°C/W] Maximum On-State Resistance @ Rated Current [RDS-ON][mOhms] Maximum PWM [Hz] (5) 10A 20A 40A 60A 10A 20A 1-150 VDC 200 10 2.5 71 0.66 0.2 1.05 66 1K 1-150 VDC 200 20 2.5 71 1.1 0.2 0.85 51 1K 1-150 VDC 200 40 2.5 142 1 0.2 0.51 24 900 1-150 VDC 200 60 2.5 213 1.1 0.2 0.42 17 700 1-300 VDC 400 10 2.5 32 2.3 0.4 0.57 230 900 1-300 VDC 400 20 2.5 48 3 0.4 0.45 155 700 INPUT SPECIFICATIONS (1) Description Control Voltage Range Minimum Input Current @ min Control Voltage [mA] Maximum Input Current @ max Control Voltage [mA] Nominal Input Impedance Maximum Turn-On Time [msec] Maximum Turn-Off Time [msec] DCxxxDxx DCxxxAxx 4-32 VDC 11 12 Current Regulated 0.075 0.32 90-140 VAC 11 13 Current Regulated 10 10 GENERAL SPECIFICATIONS Description Dielectric Strength, Input/Output/Base (50/60Hz) Minimum Insulation Resistance (@ 500 V DC) Maximum Capacitance, Input/Output Ambient Operating Temperature Range (6) Ambient Storage Temperature Range Housing Material Weight (typical) (7) Encapsulation (8) Terminal Finish Recommended Terminal Screw Torque (6-32) [in lbs/Nm] Recommended Terminal Screw Torque (8-32) [in lbs/Nm] GENERAL NOTES 1) All parameters at 40°C and per section unless otherwise specified. 2) Maximum voltage is 200 and 400VDC 3) Heat sinking required, see derating curves. 4) Low current loads and high ambient temperature can affect turn-on time. 5) @ a minimum of 8VDC control. See PWM Derating Information page 3. 6) Maximum Ambient Operating Temperature for the AC control relays is 65°C. 7) Typical weight for the AC control relays is 2.99 oz/85g. 8) AC controlled relays contain thermal conductive epoxy. MECHANICAL SPECIFICATIONS Parameters 2500 Vrms 109 Ohm 10 pF -30 to 80°C -40 to 125 °C Valox 420 SEO Black, UL 94 V-0 2.65 oz (75g) Thermally conductive Epoxy Electroless Nickel 10/1.1 20/2.2 WIRING DIAGRAM PWM DERATE INFORMATION THERMAL DERATE INFORMATION THERMAL DERATE INFORMATION AGENCY APPROVALS Designed in accordance with the requirements of IEC 62314 IEC 61000-4-2 Electrostatic Discharge Level 3, Criteria A IEC 61000-4-4 Electrically Fast Transients Level 3, Criteria A IEC 61000-4-5 Electrical Surges Level 3, Criteria A E116950 072312 ANNEX - ENVIROMENTAL INFORMATION