ActiveReports Document

PowerPlus DC
• Optically Isolated MOSFET output
• Ratings from 10A to 40A @ 150 VDC and 10 & 20A @ 300 VDC
• AC and DC control
• Relays are easily paralleled for higher-current applications
• LED Status Indicator
• Optional IP20 Cover
• UL Recognized, CE and RoHS Compliant
• PWM to 1K HZ
PRODUCT SELECTION
Control Voltage
4-32 VDC
90-140 VAC
10A
20A
40A
60A
10A
20A
DC200D10
DC200A10
DC200D20
DC200A20
DC200D40
DC200D60
DC400D10
DC400A10
DC400D20
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage [Vdc] (2)
Blocking Voltage
Rated Load Current [Adc] (3)
Minimum Load Current [mA] (4)
Maximum Surge Current [Adc] (10ms)
Maximum On-State Voltage Drop @ Rated Current [Vdc]
Maximum Off-State Leakage Current @ Rated Voltage [mA]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum On-State Resistance @ Rated Current [RDS-ON][mOhms]
Maximum PWM [Hz] (5)
10A
20A
40A
60A
10A
20A
1-150 VDC
200
10
2.5
71
0.66
0.2
1.05
66
1K
1-150 VDC
200
20
2.5
71
1.1
0.2
0.85
51
1K
1-150 VDC
200
40
2.5
142
1
0.2
0.51
24
900
1-150 VDC
200
60
2.5
213
1.1
0.2
0.42
17
700
1-300 VDC
400
10
2.5
32
2.3
0.4
0.57
230
900
1-300 VDC
400
20
2.5
48
3
0.4
0.45
155
700
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Minimum Input Current @ min Control Voltage [mA]
Maximum Input Current @ max Control Voltage [mA]
Nominal Input Impedance
Maximum Turn-On Time [msec]
Maximum Turn-Off Time [msec]
DCxxxDxx
DCxxxAxx
4-32 VDC
11
12
Current Regulated
0.075
0.32
90-140 VAC
11
13
Current Regulated
10
10
GENERAL SPECIFICATIONS
Description
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 V DC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range (6)
Ambient Storage Temperature Range
Housing Material
Weight (typical) (7)
Encapsulation (8)
Terminal Finish
Recommended Terminal Screw Torque (6-32) [in lbs/Nm]
Recommended Terminal Screw Torque (8-32) [in lbs/Nm]
GENERAL NOTES
1) All parameters at 40°C and per section unless otherwise specified.
2) Maximum voltage is 200 and 400VDC
3) Heat sinking required, see derating curves.
4) Low current loads and high ambient temperature can affect turn-on time.
5) @ a minimum of 8VDC control. See PWM Derating Information page 3.
6) Maximum Ambient Operating Temperature for the AC control relays is 65°C.
7) Typical weight for the AC control relays is 2.99 oz/85g.
8) AC controlled relays contain thermal conductive epoxy.
MECHANICAL SPECIFICATIONS
Parameters
2500 Vrms
109 Ohm
10 pF
-30 to 80°C
-40 to 125 °C
Valox 420 SEO Black, UL 94 V-0
2.65 oz (75g)
Thermally conductive Epoxy
Electroless Nickel
10/1.1
20/2.2
WIRING DIAGRAM
PWM DERATE INFORMATION
THERMAL DERATE INFORMATION
THERMAL DERATE INFORMATION
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
IEC 61000-4-2 Electrostatic Discharge
Level 3, Criteria A
IEC 61000-4-4 Electrically Fast Transients Level 3, Criteria A
IEC 61000-4-5 Electrical Surges
Level 3, Criteria A
E116950
072312
ANNEX - ENVIROMENTAL INFORMATION