AIMTEC AMES15

Series AMES15-MAZ
15 Watt | AC-DC Converter
FEATURES:
•
•
•
•
•
Screw Terminals on Input & Output
Operating temperature: -40 to +80°C
Over load, Over Voltage, Short Circuit Protection
Optional DIN Rail mounting bracket
Universal input: 90-264VAC, 47-440Hz
•
•
•
•
•
RoHS compliant
Soft start
Energy Star compliant
CE, cULus, CB approvals
4000VAC I/O Isolation
CB
Models
Single output
Model
Input Voltage
(VAC/Hz)
Input
voltage
(VDC)
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
120-370
120-370
120-370
120-370
120-370
Input Voltage
(VAC/Hz)
Input
voltage
(VDC)
90-264/47-440
90-264/47-440
90-264/47-440
120-370
120-370
120-370
AMES15-3.3SMAZ
AMES15-5SMAZ
AMES15-12SMAZ
AMES15-15SMAZ
AMES15-24SMAZ
Max
Output
wattage
(W)
9.9
15
15
15
15
Output
Voltage
(V)
3.3
5
12
15
24
Output
Current
max (A)
3
3
1.25
1
0.63
Ripple &
Noise
(mV)
Maximum
Capacitive
Load
(µF)
Efficiency
(%)
50
50
100
100
100
4700
2200
1000
680
470
74
78
81
81
83
Ripple &
Noise*
(mV)
Maximum
Capacitive
Load
(µF)
Efficiency
(%)
50
100
100
±1000
±470
±330
78
80
81
Models
Dual output
Model
AMES15-5DMAZ
AMES15-12DMAZ
AMES15-15DMAZ
Max
Output
wattage
(W)
15
15
15
Output
Voltage
(V)
±5
±12
±15
Output
Current
max (A)
±1.5
±0.63
±0.5
*Ripple & Noise measured with 1µF M/C and 47µF E/C (20MHz bandwidth)
Input Specifications
Parameters
Current
Inrush current <2ms
Leakage current
External Fuse (recommend)
Input Dissipation
Under Voltage Protection
Conditions
Typical
115VAC
230VAC
115 VAC
230 VAC
115 VAC
264 VAC
slow blow type
No load
Maximum
Units
350
180
10
20
0.1
0.2
mA
mA
A
A
mA
mA
A
W
VAC
Maximum
Units
2
<0.5
88
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation (single output)
Cross regulation (dual output)
Transient Recovery Time
Transient Recovery Deviation
Hold-up time
www.aimtec.com
F 052e R7.L
Conditions
Typical
LL-HL
0-100%
25% load - 1st out, 100% load – 2nd out
25% load step
min
Tel: +1 514 620 2722
1 of 5
±2
±0.5
±0.5
±5
200
±2
20
%
%
%
%
µs
% of Vout
ms
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMES15-MAZ
15 Watt | AC-DC Converter
Isolation Specifications
Parameters
Conditions
Tested I/O voltage
Isolation resistance
Typical
3 sec
Rated
Units
4000
VAC
MΩ
Maximum
Units
>1000
General Specifications
Parameters
Conditions
Switching frequency
Start up time
Over load protection
Over voltage protection
Short circuit protection
Short Circuit restart
Operating temperature
Storage temperature
Max Case temperature
Temperature coefficient
Cooling
Humidity
Weight
Dimensions (L x W x H)
MTBF
Typical
132
900
>131
Zener diode clamp
Continuous
Auto recovery
-40 to +80
-50 to +100
Auto recovery, hiccup mode
With derating over 55 oC (10CFM)
KHz
mS
%
o
C
C
o
C
% / oC
o
100
±0.02
Free air convection
95
100
3.62 x 2.56 x 0.94 inches
92.0 x 65.0 x 24.0 mm
> 400 000hrs (MIL-HDBK -217F, t=+25oC)
% RH
g
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Environment Approval
Parameters
Shock
Vibrations
Conditions
Wave form: Half sine wave
Acceleration amplitude: 5gn
Bump duration: 30 ms
Number of bumps: 18 (3 in each direction for every axis)
Converter operation before and after test, body mounted (on chassis)
Test mode: Sweep sine
10-100Hz, speed 0.05Hz/s
Displacement: 1mm
Acceleration: 3g
3 loops 30min one cycle, 3h total, every axis tested
Converter operation before and after test, body mounted (on chassis)
Safety & EMC Specifications
Parameters
Agency approvals
Standards
www.aimtec.com
F 052e R7.L
cULus, CE, CB
Medical Electrical Equipment
Information technology Equipment
EMI - Conducted and radiated emission
Harmonic Current Emissions
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
IEC\EN\UL 60601-1, CSA-C22.2 No. 601.1-M90
EN 60950-1:2006+A11:2009
EN55011, class B
IEC/EN 61000-3-2, (EN60555-2)
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMES15-MAZ
15 Watt | AC-DC Converter
Derating
A
A
B
100
Free Air
Convection
40 º C
80
B
60
40
10 CFM
55 º C
Safe Operating Area
20
0
- 40 - 20
0
20
40
60
80
85
100
Ambient Temperature º C
Pin Out Specifications
Pin
Single
Dual
1
2
3
4
5
AC Input (N)
AC Input (L)
-V Output
No Connection
+V Output
AC Input (N)
AC Input (L)
-V Output
Common
+V Output
www.aimtec.com
F 052e R7.L
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMES15-MAZ
15 Watt | AC-DC Converter
24
Dimensions
PCB Mounting
Screw
PCB Mounting
Screw
PCB
Mylar Film
Bracket
Mountin
g Screw
PCB
Mylar Film
2.6 mm Max
Customer Chassis
www.aimtec.com
F 052e R7.L
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMES15-MAZ
15 Watt | AC-DC Converter
Optional DIN Rail Bracket
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer
controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary
based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C,
humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all
internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for
release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications
which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at
www.aimtec.com.
www.aimtec.com
F 052e R7.L
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only