ROITHNER LD-445

LD-445-1000MG
TECHNICAL DATA
Blue Laser Diode
Features
•
•
•
•
Multi Transverse Mode
Peak Wavelength: 445 nm
Optical Ouput Power: 1W
Package: 5.6 mm, dismounted
Electrical Connection
Pin Configuration
Bottom View
m-type
PIN
1
2
3
Function
LD Anode
n.c
LD Cathode
Absolute Maximum Ratings (TC=25°C)
Item
LD Reverse Voltage
LD Forward Current
Operating Case Temperature
Storage Temperature
Symbol
VR (LD)
IF
TC
Tstg
Value
4.5
1.4
0 … +35
-30 … +70
Unit
V
A
°C
°C
Specifications (TC=25°C, IOP=1.05A)
Item
Optical Specifications
Optical Output Power (CW)
Dominant Wavelength
Beam Divergence Full Angle (1/e²)
Emission Point Accuracy
Electrical Specifications
Threshold Current
Operating Current
Operating Voltage
Slope Efficiency
Symbol
Min.
Typ.
Max.
Unit
PO
λD
ΘII
Θ┴
Δθ┴
0.9
442
5
30
-5
1.00
445
12
40
Δθ┴
1.10
448
25
50
5
W
nm
deg
deg
deg
Ith
Iop
Vop
η
150
4.0
0.8
1.05
-
200
6.0
1.8
mA
A
V
W/A
*The above specifications are for reference purpose only and subjected to change without prior notice.
02.09.2011
LD-445-1000MG
1 of 3
Package Dimensons
5.6 mm Package
02.09.2011
LD-445-1000MG
2 of 3
Safety of Laser light
•
Laser Light can damage the human eyes and skin. Do not expose the eye or skin directly to
any laser light and/or through optical lens. When handling the LDs, wear appropriate safety
glasses to prevent laser light, even any reflections from entering to the eye. Focused laser
beam through optical instruments will increase the chance of eye hazard.
Cautions
1. Operating methode
• This LD shall change its forward voltage requirement and optical ouput power according to
temperature change. Also, the LD will require more operation current to maintain same ouput
power as it degrades. In order to maintain output power, use of APC (Automatic Power
Control) is recommended. Which use monitor feedback to adjust the operation current.
• Confirm that electrical spike current generated by switching on and off does not exceed the
maximum operating current level specified herein above as absolute maximum rating. Also,
employ appropriat countermeasures to reduce chattering and/or overshooting in the circuit.
2. Static Electricity
• Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is
recommended to use a wrist trap or anti-electrostatic glove when handeling the product.
3. Absolute Maximum Rating
• Active layer of LDs shall have high current density and generate high electric field during its
operation. In order to prevent excessive damage, the LD must be operated striclty below
absolute maximum rating.
02.09.2011
LD-445-1000MG