QL85D6SA

QL85D6SA
TECHNICAL DATA
Infrared Laser Diode
Features
•
•
•
•
AlGaAs laser diode
Peak Wavelength: 850 nm
Optical Ouput Power: 5 mW
Package: 5.6 mm, with photo diode
Electrical Connection
Pin Configuration
Bottom View
m-type
PIN
1
2
3
Function
LD Cathode
LD Anode, PD Cathode
PD Anode
Absolute Maximum Ratings (TC=25°C)
Item
CW Output Power
LD Reverse Voltage
PD Reverse Voltage
Operating Case Temperature
Storage Temperature
Symbol
PO
VR (LD)
VR (PD)
TC
Tstg
Value
7
2
30
-10 … +60
-40 … +85
Unit
mW
V
V
°C
°C
Specifications (TC=25°C)
Item
Optical Specifications
CW Output Power
Peak Wavelength *
FWHM Beam Divergence
Emission Point Accuracy
Astigmatism
Electrical Specifications
Threshold Current
Operating Current
Slope Efficiency
Operating Voltage
Monitor Current
Angle
Symbol
Min.
Typ.
Max.
Unit
PO
λP
θ║
θ┴
Δθ║
Δθ┴
As
845
7
25
-2.0
-3.0
5
850
9
32
-
855
12
40
2.0
3.0
15
mW
nm
deg
deg
deg
deg
µm
Ith
Iop
η
Uop
Im
5
15
0.4
0.2
10
20
0.7
1.9
0.4
20
30
0.9
2.5
0.6
mA
mA
W/A
V
mA
* Measuring specifications.
The above specifications are for reference purpose only and subjected to change without prior notice.
09.05.2012
QL85D6SA
1 of 5
Package Dimensons
5.6 mm Package (Unit:mm)
09.05.2012
QL85D6SA
2 of 5
Typical Characteristics
Optical Ouput Power vs. Forward Current
Wavelenght vs Temperature
Far Field Pattern (Po=5mW, Tc=25°C)
09.05.2012
QL85D6SA
3 of 5
Monitor Current vs Optical Power
Operating Voltage vs Temperature
Threshold Current vs Temperature
09.05.2012
QL85D6SA
4 of 5
Cautions
1. Operating methode
• This LD shall change its forward voltage requirement and optical ouput power according to
temperature change. Also, the LD will require more operation current to maintain same ouput
power as it degrades. In order to maintain output power, use of APC (Automatic Power
Control) is recommended. Which use monitor feedback to adjust the operation current.
• Confirm that electrical spike current generated by switching on and off does not exceed the
maximum operating current level specified herein above as absolute maximum rating. Also,
employ appropriat countermeasures to reduce chattering and/or overshooting in the circuit.
2. Static Electricity
• Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is
recommended to use a wrist trap or anti-electrostatic glove when handeling the Product.
3. Absolute Maximum Rating
• Active layer of LDs shall have high current density and generate high electric field during its
operation. In order to prevent excessive damage, the LD must be operated striclty below
absolute maximum rating.
09.05.2012
QL85D6SA