PI01S/D Sries 1W DC/DC CONVERTER, High isolation, SIP-Package FEATURES Efficiency up to 75% SIP Package with Industry Standard Pinout High Isolation Volage 6000 VDC Lead free ,RoHs Complian Industrial & Medical Safety Approval Operating Temperature range - 25°C to +85°C Low isolation Capacitance >2 MHours MTBF 3 Years Product Warranty The PI01S/D series are miniature, SIP Package, isolated 1W DC/DC converters with 6,000VDC isolation. It allows a wide operating temperature range of –25°C to +85°C. With high isolation, PI01S/D is suitable for all kinds of medical device application. These high isolated DC/DC converters are the latest offering from a world leader in power systems technology and manufacturing ― Delta Electronics, Inc. Model List Model Number Input Voltage (Range) Output Voltage Max. Min. VDC VDC mA mA mA(typ.) 5 200 4 303 10 12 80 2 291 8 15 65 1 295 8 ±5 ±100 ±2 303 PI01D0512A ±12 ±40 ±1 267 8 PI01D0515A ±15 ±35 ±1 287 8 PI01S1205A 5 200 4 126 10 PI01S1212A 12 80 2 121 8 15 65 1 123 8 66 ±5 ±100 ±2 126 10 66 PI01D1212A ±12 ±40 ±1 108 8 PI01D1215A ±15 ±35 ±1 117 8 PI01S0505A PI01S0512A PI01S0515A PI01D0505A PI01S1215A PI01D1205A 5 (4.5 ~ 5.5) 12 (10.8 ~ 13.2) Output Current Input Current Load Regulation Max. capacitive Load % (max.) uF @Max. Load @No Load mA(typ.) 55 30 Efficiency (typ.) @Max. Load % 66 680 66 66 10 66 220* 72 73 66 680 220* 66 74 75 * For each output DS_PI01S/D_03202012 E-mail: [email protected] http://www.delta.com.tw/dcdc P1 Input Characteristics Parameter Model 5V Input Models 12V Input Models 5V Input Models 12V Input Models Input Voltage Range Input Surge Voltage (1 sec. max.) Reverse Polarity Input Current Input Filter Internal Power Dissipation Min. 4.5 10.8 -0.7 -0.7 --- Typ. 5 12 ------- All Models Max. 5.5 13.2 9 29 0.3 Unit VDC 650 mW A LC Filter --- --- Output Characteristics Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise (20MHz) Ripple & Noise (20MHz) Ripple & Noise (20MHz) Conditions Dual Output, Balanced Loads For Vin Change of 1% Io=20% to 100% Over Line, Load & Temp. Temperature Coefficient Short Circuit Protection Min. ------- Typ. Max. ±1.0 ±3.0 ±0.1 ±1.0 ±1.2 ±1.5 See Model Selection Guide 100 150 --200 --15 --------- ±0.01 ±0.02 0.5 Second Max. Unit % % % mV P-P mV P-P mV rms %/℃ Isolation and Safety Standards Parameter Conditions Min. Typ. Max. Unit 60 Seconds 3000 --- --- VACrms I/O Isolation Test Voltage Flash tested for 1 Second 4500 --- --- VPK I/O Isolation Resistance 500 VDC 10 --- --- GΩ 20 pF I/O Isolation Voltage (rated) I/O Isolation Capacitance 100KHz, 1V --15 cUL/UL60950-1, CSA C22.2 No. 60950-1-03 UL60601-1,CSA C22.2 No.601-1 IEC/EN 60950-1, IEC/EN 60601-1 IEC60950-1 CB report, cUL/UL 60950-1 certificate UL60601-1 UL certificate Safety Standards Approvals General Characteristics Parameter Conditions Min. Typ. Max. Unit 50 80 100 KHz 2,000,000 --- --- Hours Switching Frequency MTBF (calculated) MIL-HDBK-217F@25℃, Ground Benign Recommended Input Fuse 5V Input Models 12V Input Models 500mA Slow-Blow Type 200mA Slow-Blow Type Environmental Specifications Parameter Conditions Min. Max. Unit Ambient -25 +85 ℃ Case Temperature --- +90 ℃ Storage Temperature Range -50 +125 ℃ Humidity (non condensing) --- 95 % rel. H 260 ℃ Operating Temperature Range (with Derating) Cooling Free-Air convection Lead Temperature (1.5mm from case for 10Sec.) --- DS_PI01S/D_03202012 E-mail: [email protected] http://www.delta.com.tw/dcdc P2 Power Derating Curve 100 Natural convection Output Power (%) 80 100LFM 200LFM 60 400LFM 40 20 0 ~ -25 0 20 40 60 80 100 110 Ambient Temperature Notes 1 2 3 4 5 Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted. Ripple & Noise measurement bandwidth is 0-20MHz. These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. All DC/DC converters should be externally fused at the front end for protection. Specifications subject to change without notice. DS_PI01S/D_03202012 E-mail: [email protected] http://www.delta.com.tw/dcdc P3 Mechanical Drawing Mechanical Dimensions Pin Connections 3.50 2.54 [0.14][0.10] 7.62 [0.30] Single Output Dual Output 1 +Vin +Vin -Vin -Vin 12.5 [0.49] 0.5 [0.02] 0.5 [0.02] Pin 2 5 -Vout -Vout 6 No Pin Common 3.2 [0.13] 22.0 [0.87] 7 +Vout +Vout ►All dimensions in mm (inches) 2X2.54 [2X0.10] ►Tolerance: X.X±0.25 (X.XX±0.01) X.XX±0.13 ( X.XXX±0.005) ►Pins ±0.05 (±0.002) 21.0 [0.83] 6 7 0.25 [0.01] 0.50 [0.02] 5 2.0 [0.08] 2 7.5 [0.30] Bottom View 1 Physical Outline Case Size : 22.0x7.5x12.5mm (0.87x0.30x0.49 Inches) Case Material : Non-Conductive Black Plastic (flammability to UL 94V-0 rated) Weight : 3.9g DS_PI01S/D_03202012 E-mail: [email protected] http://www.delta.com.tw/dcdc P4 Part Numbering System P I 01 S 05 12 A Form factor Family series Watt Number of Outputs Input Voltage Output Voltage Option Code D-DIP P-SIP S-SMD A~Z 01:1W 02:2W 03:3W 04:4W 06:6W 03:3.3V 05: 5V 12:12V 24: 24V 48:48V 03:3.3V 05: 5V 12:12V 15: 15V 24: 24V S - Single D- Dual A - Std. Functions WARRANTY Delta offers a three(3) years limited warranty. Complete warranty information is listed on our web site or is available upon request from Delta. Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice. DS_PI01S/D_03202012 E-mail: [email protected] http://www.delta.com.tw/dcdc P5