HIGH PERFORMANCE POWER ENTRY SERIES MODULE EMI FILTERS V D E SPECIFICATIONS INTRODUCTIONS 1. Power module incorporates an IEC connector, single or double-fuse (IEC 5x20mm or 3AG 6.3x32mm) holder, optional voltage selector switch and double-pole power switch, plus an EMI filter all-in-one easy-to-install unit. 2. Adapts to 100-120V or 200-240V input voltage by simply reversing the fuse cartridge. 3. All part numbers are UL recognized, CSA certified and VDE approved. 4. Switch electrical lifetime: 10,000 cycles. Maximum inrush current: 70A. 1. Maximum leakage current each line-to-ground @ 115VAC 60Hz: 0.25mA 0.4mA (4700pF) @ 250VAC 50Hz: 0.45mA 0.8mA (4700pF) 2. Hipot rating (one minute) line-to-ground: 2250VDC line-to-line: 1450VDC 3. Operating frequency: 50/60Hz 4. Rated voltage: 115/250VAC COMPONENTS PART NO. 03EK3/A 03EK3B/S 03EK3L/S 03EK3S/A 06EK3/A 06EK3S/A 10EK3/A 10EK3S/A L (mH) 8 2.3 13.77 8 C1 (uF) 0.22 0.22 0.47 C2 (uF) 0.1 0.1 0.22 Cy (pF) 3300 4700 4700 0.22 0.1 3300 V D E 2.5 1.6 R: 1M Lg: 400uH (EK3A, EK3SA only) TYPE & FEATURE 03EK3 03EK3B POWER ENTRY MODULE FILTERS DELTA PART NO. FUSE IEC CONNECTOR DOUBLE POLE POWER SWITCH VOLTAGE SELECTOR SW ELECTRICAL SCHEMATIC 03EK3A 03EK3L 06EK3 10EK3 DOUBLE 06EK3A 10EK3A DOUBLE FIG.A FIG.B 03EK3S 03EK3BS 03EK3SA 03EK3LS 06EK3S 10EK3S SINGLE 06EK3SA 10EK3SA SINGLE FIG.A FIG.B UL, CSA & VDE approved current rating: UL-10A both at 125VAC & 250VAC; CSA & VDE-6A at 250VAC. UL, CSA & VDE approved current rating: UL & CSA-10A both at 125VAC & 250VAC; VDE-10A at 250VAC. ELECTRICAL SCHEMATIC SW 1 F L L I N E 2 C1 Cy R C2 L Cy L O A D 3 N G G' SW L L I N E 110V 110V 1 F 2 C1 Cy R C2 L Cy L O A D 3 N 4 G' G 4 Lg FOR XXEK3SA (M) FOR XXEK3S (M) EK3A, EK3SA FIG. B FIG. A 4-10 110V 110V INSERTION LOSS (TYPICAL) 03EK3 06EK3 DIFF. MODE DIFF. MODE COMMON MODE COMMON MODE 80 dB 80 dB 60 dB 60 dB 40 dB 40 dB 20 dB 20 dB 0 dB 1M 100K 10K 0 dB 10M 1M 100K 10K DIFF. MODE DIFF. MODE COMMON MODE COMMON MODE 10EK3 10EK3A 10M MINIMUM INSERTION LOSS IN dB COMMON MODE (L-G) IN 50 OHM SYSTEM 3A CURRENT RATING .15 3A 32 FREQUENCY-MHz .50 1.0 5.0 38 38 38 10 38 30 25 6A 10A 3A (A,SA) 6A (A,SA) 10A (A,SA) 30 25 40 30 25 40 40 45 40 45 30 30 25 30 30 20 15 30 20 20 35 30 40 35 30 40 40 40 40 45 DIFFERENTIAL MODE (L-L) IN 50 OHM SYSTEM 20 50 55 40 40 30 6A 5 10A 3 3A (A,SA) 20 6A (A,SA) 5 10A (A,SA) 3 40 35 50 40 35 50 45 50 50 45 40 40 50 40 45 40 40 45 40 40 40 30 30 40 30 +0.02 1.14-0 +0.5 29.0-0 1.575 0.004 40.0 0.1 1.99MAX. 50.5MAX. 1.575 0.02 40.0 0.5 110-120V USE ONLY WITH 250V FUSES/EMPLOYER UNIQUEMENT AVEC DES FUSIBLES DE 250V MECHANICAL CONSTRUCTION +0.02 2.37-0 +0.5 60.2-0 220-240V 1.12 0.02 28.4 0.5 2.58MAX. 65.5MAX. M3(2X) R0.0984MAX. R2.5MAX. 0.13 0.3(2X) 3.3 0.3(2X) 2.37MAX. 60.2MAX. 4-11 3.28MAX. 83.3MAX. 3.51MAX. 89.2MAX. SUGGESTED MOUNTING CUTOUT (MOUNTING FROM FRONT) 1.14MAX. 29.0MAX. UNIT: INCH mm POWER ENTRY MODULE FILTERS CSA approved 6A at 125/250 VAC; VDE-6A/250VAC