AIMTEC AMSR

Series AMSR-78Z
Up to 7.5Watt | DC-DC Switching Regulator
FEATURES:
•
•
•
•
Models
Single output
Model
Input Voltage
(V)
AMSR-781.5Z
AMSR-781.8Z
AMSR-782.5Z
AMSR-783.3Z
AMSR-7805Z
AMSR-786.5Z
AMSR-787.2Z
AMSR-7809Z
AMSR-7812Z
AMSR-7815Z
4.75-30
4.75-34
4.75-34
4.75-34
6.5-34
8-34
9-34
11-34
15-34
18-34
Input Specifications
Parameters
Voltage range
Filter
No load Input Current
Input Reflected Ripple Current
Absolute Maximum Stress rating
Output Specifications
Parameters
Voltage accuracy
Short Circuit protection
Short Circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
General Specifications
Parameters
RoHS Compliant
3 Pin SIP Package
Non-Isolated
Low ripple and noise
Output
Voltage
(V)
1.5
1.8
2.5
3.3
5
6.5
7.2
9
12
15
Nominal
Conditions
10-100% load
20MHz Bandwidth
Conditions
•
•
•
Output
Current max
(mA)
500
500
500
500
500
500
500
500
500
500
Operating temperature -40°C to +85
Very high efficiency up to 97%
Pin compatible to multiple manufacturers
Maximum
Capacitive load
(µF)
220
220
220
220
220
220
220
220
220
220
Typical
See the table above
Capacitor
Typical
±2
±0.5
±0.6
±0.02
60
Typical
Efficiency
Vin Max
(%)
78
82
87
91
94
95
95
96
97
97
Efficiency
Vin Min
(%)
65
70
76
81
85
88
89
92
94
95
Maximum
Units
8
35
-0.3-34
mA
mA p-p
VDC
Maximum
Units
Continuous
Auto recovery
VDC
%
%
%
%/oC
mV p-p
Maximum
Units
KHz
Switching frequency
100% load
330
o
C
Operating temperature
Without derating
-40 to +85
o
C
Storage temperature
-40 to +125
o
Max Case temperature
100
C
Cooling
Free air convection
Humidity
95
%
Case material
Non-conductive black plastic (UL94V-0 rated)
Weight
1.8
g
Dimensions (L X W X H)
0.46 x 0.29 x 0.38 inches 11.70 x 7.50 x 9.70 mm
MTBF
> 1 121 000 hrs (MIL-HDBK-217F, Ground Benign, t=+25 oC)
o
C
Soldering Temperature
1.5 mm from case for 10 sec
260
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
www.aimtec.com
F 051e R8.C
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMSR-78Z
Up to 7.5Watt | DC-DC Switching Regulator
Safety Specifications
Parameters
Agency Approval
CE
EN55022: 2006 + A1:2007, Class B
EN55024:1998 + A1:2001 + A2:2003
IEC61000-4-2:1995 + A1:1998 + A2:2000, Perf. Criteria B
IEC61000-4-3:2006, Perf. Criteria A
IEC61000-4-4:2004, Perf. Criteria B (external 220uF/100V cap required)
IEC61000-4-6:2007, Perf. Criteria A
IEC61000-4-8, Perf:1993 + A1:2000, Criteria A
NOTE: also designed to meet IEC 60950-1:2001
Standards
Pin Out Specifications
Pin
Dimensions
Single
1
2
3
+V Input
Ground
+V Output
Typical Application Circuit
Vin
1
C1
22µF
GND
AMSR1-78XX-Z
2
3
Vout
C2
100µF
GND
C1: A low ESR capacitor is required to keep the converter to a minimum.
Ceramic capacitors are recommended, but tantalum or electrolytic may
be used. Typical value is 22µF / 50V.
C2: Installation of C2 is recommended but optional. Typical value
100µF / 25V electrolytic.
NOTE: It is not recommended to connect in parallel.
www.aimtec.com
F 051e R8.C
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMSR-78Z
Up to 7.5Watt | DC-DC Switching Regulator
Recommended Circuits
Conducted and Radiated Emissions
6.4uH
L
+V output
+V input
C1
C2
470uF
35V
470uF
35V
DC/DC
Converter
-V input
Load
-V output
EFT/Surge
+V output
+V input
DC/DC
Converter
C2
Load
220uF
100V
-V input
-V output
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R8.C
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only