TENSILITY 50

Materials
1. Spring contact, beryllium copper, 2 μm nickel plated
2. Insulator, POM, black
3. Center contact, brass, 2 μm nickel plated
4. Shell, C3604 brass, 2 μm nickel plated

Electrical requirements
Dielectric strength: 1 min @ 500 Vac
Insulation resistance: 100 MΩ @ 500 Vdc
Contact resistance: 30 mΩ or less
Rated voltage: 20 Vdc
Rated current: 4 A

Mechanical requirements
Insertion force: 0.3-2.5 kgf
Withdrawal force: 0.3-2.5 kgf
Durability: 5000 mating cycles while maintaining; 0.3 kgf
min. insertion force, 0.2 kgf min. withdrawal force and a
less
than 100 mΩ contact resistance.

Environmental requirements
Damp test: 40 °C, RH 90-100% for 96 hrs. Cool to ambient
and recover for 2 hours. Maintain dielectric strength of 500
Vac for 1 min, insulation resistance of 50 MΩ @ 500 Vdc
minimum and a contact resistance of 100 mΩ or less.

Dry test: 70 °C, RH 70-85% for 96 hrs. Cool to ambient and
recover for 2 hours. Maintain insulation resistance of 50
MΩ @ 500 Vdc minimum and a contact resistance of 100
mΩ or less.

Salt spray test: 35 °C, RH 90-95%, 5% NaCl mist for 24 hrs.
Wash parts after test. Maintain mechanical requirements
and a contact resistance of less than 80 mΩ.

Operating range
-25 to 70 °C, relative humidity of 85% or less
Revision
Date
16.5 ±0.50
2.5
+0.10
3.6 - 0
2/20/2012
Initial release
A1
12/5/2011
updated description to standard
A2
2/20/2012
updated drawing
A3
11/9/2012
Added test data
1
1.32 ±0.02
6 ±0.05
2.3
4
1
9.5
Notes
RoHS compliant
Function test: no open, no short circuit, no INT
DIMENSIONS ARE IN MILLIMETERS
TOLERANCES:
X:
0.5 mm
X.X:
0.3 mm
X.XX: 0.05 mm
5
2
3
Description
A
7 ±0.10 1
4
20802 Sockeye Place #130
Bend, OR 97701 USA
tel 541.323.3228 fax 541.323.4202
800 877.670.7118 www.tensility.com
DESCRIPTION:
Connector, dc jack, 3.5x1.35xL16.5 mm,
molding style
SIZE Part number
A
50-00057
SCALE: 2:1
3
2
SHEET 1 OF 1
WEIGHT:
1