Materials 1. Spring contact, beryllium copper, 2 μm nickel plated 2. Insulator, POM, black 3. Center contact, brass, 2 μm nickel plated 4. Shell, C3604 brass, 2 μm nickel plated Electrical requirements Dielectric strength: 1 min @ 500 Vac Insulation resistance: 100 MΩ @ 500 Vdc Contact resistance: 30 mΩ or less Rated voltage: 20 Vdc Rated current: 4 A Mechanical requirements Insertion force: 0.3-2.5 kgf Withdrawal force: 0.3-2.5 kgf Durability: 5000 mating cycles while maintaining; 0.3 kgf min. insertion force, 0.2 kgf min. withdrawal force and a less than 100 mΩ contact resistance. Environmental requirements Damp test: 40 °C, RH 90-100% for 96 hrs. Cool to ambient and recover for 2 hours. Maintain dielectric strength of 500 Vac for 1 min, insulation resistance of 50 MΩ @ 500 Vdc minimum and a contact resistance of 100 mΩ or less. Dry test: 70 °C, RH 70-85% for 96 hrs. Cool to ambient and recover for 2 hours. Maintain insulation resistance of 50 MΩ @ 500 Vdc minimum and a contact resistance of 100 mΩ or less. Salt spray test: 35 °C, RH 90-95%, 5% NaCl mist for 24 hrs. Wash parts after test. Maintain mechanical requirements and a contact resistance of less than 80 mΩ. Operating range -25 to 70 °C, relative humidity of 85% or less Revision Date 16.5 ±0.50 2.5 +0.10 3.6 - 0 2/20/2012 Initial release A1 12/5/2011 updated description to standard A2 2/20/2012 updated drawing A3 11/9/2012 Added test data 1 1.32 ±0.02 6 ±0.05 2.3 4 1 9.5 Notes RoHS compliant Function test: no open, no short circuit, no INT DIMENSIONS ARE IN MILLIMETERS TOLERANCES: X: 0.5 mm X.X: 0.3 mm X.XX: 0.05 mm 5 2 3 Description A 7 ±0.10 1 4 20802 Sockeye Place #130 Bend, OR 97701 USA tel 541.323.3228 fax 541.323.4202 800 877.670.7118 www.tensility.com DESCRIPTION: Connector, dc jack, 3.5x1.35xL16.5 mm, molding style SIZE Part number A 50-00057 SCALE: 2:1 3 2 SHEET 1 OF 1 WEIGHT: 1