MB89R118C

FUJITSU SEMICONDUCTOR
DATA SHEET
DS411-00001-4v1-E
ASSP
ISO/IEC 15693 Compliant FRAM Embedded
TM
High-speed RFID LSI
MB89R118C
■ DESCRIPTION
The MB89R118C is a vicinity type of RFID LSI device embedded with 2 Kbytes FRAM, which enables fast
and frequent write operation.
■ FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
•
Memory capacity of 2 Kbytes FRAM (including 2000 bytes of user area)
8-byte/block configuration, 256 blocks
High-speed data transmission at 26.48 kbps
Fast command supported (data transmission at 52.97 kbps) (Transponder → Reader/Writer)
Carrier frequency at 13.56 MHz
Anti-collision function : 30 tags per second
Read/Write endurance : 1012 times
Data retention : 10 years ( + 85 °C) , 30 years (+70 °C)
64-bit UID
FRAM memory data protection
Electronic article surveillance (EAS) command
Compliance with ISO/IEC 15693 (partly not supported*)
Compliance with ISO/IEC 18000-3 (Mode 1) (partly not supported*)
* : Refer to “
■ USAGE NOTES”.
Note : FerVID family is a trademark of Fujitsu Semiconductor Limited, Japan.
Copyright 2010-2015 FUJITSU SEMICONDUCTOR LIMITED
2015.8
MB89R118C
■ BLOCK DIAGRAM
Analog RF interface
Antenna
coil
Digital control
FRAM
Rectifier
Clock generator
VDD
I/O
R/W
Power supply
voltage control
Modulator
Demodulator
2
Clock Commands
FRAM access
Data output
2 Kbytes
Data output
Data input Anti-collision
function
Data input
DS411-00001-4v1-E
MB89R118C
■ MEMORY MAP
This section describes the FRAM memory, which is the internal memory of the MB89R118C.
• FRAM Configuration
The FRAM has 2000 bytes for use as user area and 48 bytes for use as system area.
The FRAM memory areas consist of a total of 256 blocks (250 blocks of user area and 6 blocks of system
area). Each block can store 64 bits (8 bytes) of data.
The block is the unit used for the writing and reading of FRAM data. The memory configuration of FRAM is
shown below.
• FRAM memory configuration
Area
Block No.
User area (2000 bytes)
System area (48 bytes)
Details
Data read
Data write
00H to F9H
User area
Yes
Yes
FAH
UID (64 bits)
Yes
No
FBH
AFI, DSFID, EAS,
security status
Yes
Limited
FCH to FFH
Block security status
Yes
No
Blocks “00H” to “F9H” are user area. The user area is defined as an area that can be accessed when the
corresponding block address is specified. On the other hand, Blocks “FAH” to “FFH” are system area. The
system area is defined as an area that can be accessed only with a specific command.
The system area consists of 6 blocks and contains UID, AFI, DSFID, EAS bits, and security status (can write
or cannot write) data for individual block. UID is fixed and cannot be updated. AFI, DSFID, and EAS bits are
written at the factory, and can be updated and locked (disable to write) with commands (Only EAS bit cannot
be locked) .
As shown in above, “FAH” holds the UID, and “FCH” to “FFH” hold the security status information on individual
user areas.
The configuration of “FBH” to “FFH” blocks is shown below. “FBH” block is used for EAS status, AFI and DSFID
data, the security status data of AFI and DSFID. “FCH” to “FFH” blocks contain block security status data.
• Structure of “FBH”
MSB
64
LSB
57 56
EAS
Status
33
RFU*
32
25
24
17
DSFID
Lock
AFI
Lock
Status
Status
16
DSFID
9
8
1
AFI
* : Reserved for future use
DS411-00001-4v1-E
3
MB89R118C
• Structure of “FCH” to “FFH”
Block security status (BSS) of user
block 3FH
Block security status (BSS) of user
block 00H
MSB
LSB
FCH
3F
3E
3D
3C
3B
3A
39
03
02
01
00
FDH
7F
7E
7D
7C
7B
7A
79
43
42
41
40
FEH
BF
BE
BD
BC
BB
BA
B9
83
C3
82
C2
81
C1
80
C0
FFH
RFU* (6 bits)
F9
* : Reserved for future use
The security status of the user area is stored in the block security status bit in system area blocks of “FCH”
to “FFH” per bit in each block. A user area is unlocked when the corresponding block security status bit is
“0”; it is locked (disable to write state) when the corresponding block security status bit is “1”.
EAS bit is a 1 bit, and it is used for setting EAS status. It is possible to read/write data of 2 blocks at one
time in the user area (If Read Multiple Blocks Unlimited command is used, up to 256 blocks can be accessed
at one time) .
4
DS411-00001-4v1-E
MB89R118C
■ DATA ELEMENT DEFINITION
1. Unique Identifier (UID)
The MB89R118C has a 64-bit unique identifier (UID) that complies with ISO/IEC 15693-3. The UID is used
to distinguish a transponder from another transponder in the anti-collision algorithm described later.
The UID consists of the 3 items shown in the following.
• An 8-bit data whose value is always “E0H” (bit 57 to bit 64)
• An 8-bit IC manufacturer code whose value is always “08H”, and is defined by ISO/IEC 7816-6/AMI
(bit 49 to bit 56)
• Unique 48-bit serial number assigned by FUJITSU SEMICONDUCTOR (bit 1 to bit 48)
Among the unique 48-bit serial number assigned by FUJITSU SEMICONDUCTOR, the 1 byte from bit 41
to bit 48 defines MB89R118C code whose value is “01H”. And the 5 bytes from bit 1 to bit 40 define other
serial number.
• Structure of UID
MSB
LSB
64
57 56
“E0H”
DS411-00001-4v1-E
49 48
IC manufacturer
code “08H”
41 40
“01H”
1
Other serial number
Unique serial number assigned by
FUJITSU SEMICONDUCTOR
5
MB89R118C
2. Application Family Identifier (AFI)
The application family identifier (AFI) identifies the type of application set by the transponder.
The AFI can be written with a command. The AFI is 8-bit data and is stored in the system area of FRAM.
The factory default setting of the AFI is “00H”.
• Types of AFI
Application Application
Sub-Family
Family
(bit 8 to bit 5) (bit 4 to bit 1)
Application Use Field
Example/Note
“0”
“0”
All families and sub-families
No applicative preselection
X
“0”
All sub-families of family X
Wide applicative preselection
X
Y
Only the Yth sub-families of family X
⎯
“0”
Y
All families of Yth sub-families
⎯
“1”
“0”, Y
Transport
Mass transit, bus, airline
“2”
“0”, Y
Financial
IEP, banking, retail
“3”
“0”, Y
Identification
Access control
“4”
“0”, Y
Telecommunication
Public telephone, GSM
“5”
“0”, Y
Medical
⎯
“6”
“0”, Y
Multimedia
Internet services
“7”
“0”, Y
Gaming
⎯
“8”
“0”, Y
Data storage
Portable files
“9”
“0”, Y
EAN-UCC system for
application identifiers
Managed by ISO/IEC JTC 1/SC 31
“A”
“0”, Y
ISO/IEC JTC 1/SC 31
Data identifiers as defined in
ISO/IEC 15418
“B”
“0”, Y
UPU
Managed by ISO/IEC JTC 1/SC31
“C”
“0”, Y
IATA
Managed by ISO/IEC JTC 1
“D”
“0”, Y
“E”
“0”, Y
“F”
“0”, Y
Managed by ISO/IEC JTC 1/SC 17
RFU*
Managed by ISO/IEC JTC 1/SC 17
Managed by ISO/IEC JTC 1/SC 17
* : Reserved for future use
Note : Both X value and Y value are “1” to “F”.
In the status of the AFI_flag setting;
• If the AFI is not supported by the transponder, no response to all requests is returned.
• If the AFI is supported by the transponder, the response is returned only if the value is in accord with
the AFI sent from a reader/writer.
3. Data Storage Format Identifier (DSFID)
The data storage format identifier (DSFID) indicates how data is structured in the transponder (LSI memory
device). The DSFID can be programmed with a command.
The DSFID is 8-bit data and is stored in the system area of FRAM. The factory default setting of the DSFID
is “01H”.
6
DS411-00001-4v1-E
MB89R118C
4. Cyclic Redundancy Check (CRC)
When a frame is received, reception of correct data making up the frame is assumed only when the value
of the cyclic redundancy check (CRC) code is valid. For error-checking purposes, a 2-byte CRC code value
is inserted between data and the EOF signal.
The value of CRC code is required from all the data contained between the SOF and CRC field in each
frame. Method of calculation is provided in ISO/IEC 13239. The details are provided in ISO/IEC 15693-3
and ISO/IEC 18000-3 (Mode 1) . The initial value of the CRC code provided in ISO/IEC 15693-3 is “FFFFH”.
The CRC code is transferred, beginning with the lowest-order bit in the lowest-order byte.
• CRC bit/byte transition order
LSByte
LSBit
MSByte
MSBit
CRC 16 (8 Bits)
LSBit
MSBit
CRC 16 (8 Bits)
First transmitted bit of the CRC
5. Electronic Article Surveillance (EAS) status
EAS status is 1 bit data (LSB side) , which is stored in the system area of FRAM. The initial value is “1”.
EAS bit “1” means goods-monitoring status, and EAS bit “0” means that goods-monitoring status is cleared.
EAS status can be written by Write EAS command and can be checked “FBH” block (refer to “■ MEMORY
MAP”) by Read commands such as Read Single Block command.
Together with Gate type reader/writer, EAS command can support anti-theft security functions.
DS411-00001-4v1-E
7
MB89R118C
■ FUNCTION DESCRIPTION
1. Communication from Reader/Writer to Transponder
(1) Modulation method
The MB89R118C supports both 10% ASK modulation and 100% ASK modulation.
Modulation index m is defined as m = (a - b)/(a + b) with reference to the modulated waveform shown below.
The values a and b indicate, respectively, the maximum and minimum amplitude of magnetic field transmitted
from a reader/writer.
• Modulation of the carrier for 10% ASK
hr
y
y
hf
t2
t1
a
t3
b
0V
13.56 MHz
• Modulation of the carrier for 100% ASK
t3
t1
t4
105 %
95 %
60 %
a
5%
0V
t2
b
13.56 MHz
Maximum and minimum values of t1, t2, t3 and t4 are shown in the table of “ ■RECOMMENDED OPERATING
CONDITIONS”. In this table, y is 0.05 (a-b) and the maximum value of hf and hr is 0.1(a-b).
8
DS411-00001-4v1-E
MB89R118C
(2) Data rate and data coding
The MB89R118C supports only 1 out of 4 mode for bit coding, not 1 out of 256 mode. In 1 out of 4 mode,
2-bit signals are coded in a period of 75.52 μs as shown in the following. When coding takes place, the data
rate is 26.48 kbps (fc/512). Each signal is transmitted beginning with the lowest bit.
• Coding Method in 1 out of 4 Mode
• “00B” pulse position
9.44 μs
9.44 μs
75.52 μs
• “01B” pulse position (1 = LSB)
28.32 μs
9.44 μs
75.52 μs
• “10B” pulse position (0 = LSB)
47.20 μs
9.44 μs
75.52 μs
• “11B” pulse position
66.08 μs
9.44 μs
75.52 μs
(3) Data frame
A data frame begins with a start of frame (SOF) signal and ends with an end of frame (EOF) signal.
The MB89R118C is enabled to receive a frame from a reader/writer within 300 μs after the MB89R118C
has sent a frame to the reader/writer. The MB89R118C is also enabled to receive a frame from a reader/
writer within 1 ms after power has been supplied to the MB89R118C.
• Waveforms of SOF and EOF signals of a frame sent from a reader/writer
SOF
9.44 μs
9.44 μs
37.76 μs
9.44 μs
37.76 μs
EOF
37.76 μs
DS411-00001-4v1-E
9.44 μs
9.44 μs
9
MB89R118C
2. Communication from Transponder to Reader/Writer
• Minimum load modulation amplitude (Vlm) : 10 mV (based on ISO/IEC 10373-7)
• Load modulation subcarrier frequency (fs) : 423.75 kHz(fc/32)
The MB89R118C supports only a 1-subcarrier system.
(Not supports 2-subcarrier system.)
• Data rate : The MB89R118C supports the following 2 data rate modes :
• Low data rate
• High data rate
One of the 2 data rate modes is specified by the Data_rate_flag (described later) sent from
the reader/writer. In low data rate mode, the data rate is 6.62 kbps (fc/2048); in high data rate
mode, it is 26.48 kbps (fc/512).
When receiving the Fast commands (Custom commands) , the communication starts from
the transponder in the data rate that is twice as fast as normal data rate. In this case, the
2 data rate modes of low data rate and high data rate specified by the Data_rate_flag is
supported. In Low data rate mode, the data rate is 13.24 kbps (fc/1024) ; in high data rate
mode, it is 52.97 kbps (fc/256) .
(1) Bit coding
The Manchester coding is used for the bit coding. The following figures show the signals modulated in high
data rate mode when ISO command is received and the same signals when fast command is received. In
low data rate mode of both ISO commands and fast commands, the number of pulses for subcarrier and
data transfer time are 4 times as large as the number in high data rate mode.
• Signal waveforms by load modulation in high data rate mode (ISO commands)
• Logic 0
423.75 kHz subcarrier
18.88 μs (modulated)
18.88 μs
(not modulated)
37.76 μs
• Logic 1
423.75 kHz subcarrier
18.88 μs
(not modulated)
18.88 μs (modulated)
37.76 μs
• Signal waveforms by load modulation in high data rate response mode (fast commands)
• Logic 0
9.44 μs
9.44 μs
18.88 μs
• Logic 1
9.44 μs
9.44 μs
18.88 μs
10
DS411-00001-4v1-E
MB89R118C
(2) Data frame
A data frame sent from a transponder starts with a start of frame (SOF) signal and ends with an end of frame
(EOF) signal. The following figures show the SOF and EOF signals sent in high data rate mode when an
ISO command is received and the same signals when a fast command is received. In low data rate mode
of both ISO commands and fast commands, the number of pulses in subcarrier and data transfer time are
4 times as large as the number in high data rate mode. The reader/writer shall be ready to receive a frame
from the transponder within 300 μs after having sent a frame to the transponder.
• Waveforms of SOF and EOF signals of a frame sent from a transponder (ISO commands)
• SOF
423.75 kHz subcarrier
56.64 μs
56.64 μs
37.76 μs
• EOF
37.76 μs
56.64 μs
56.64 μs
• Waveforms of SOF and EOF signals of a frame sent from a transponder (fast commands)
• SOF
423.75 kHz
Subcarrier
28.32 μs
28.32 μs
18.88 μs
• EOF
423.75 kHz
Subcarrier
18.88 μs
28.32 μs
28.32 μs
3. FRAM Data Protection if Power Lost During Data Writing
MB89R118C accesses to FRAM with the unit of 1 byte. When RF power is shut down during accessing
FRAM, writing in FRAM is completed by the charges stored in a smoothing capacitor on the LSI and FRAM
data writing error is prevented.
Therefore, the commands of 1 byte access such as Write AFI, Write DSFID, Write EAS, and Lock command
can protect the data from the power down.
On the other hand, the commands of more than 2 bytes access such as Write Single Block command may
not protect all the data from the power down during the access. In this case, it is recommended to confirm
the data correctness by a read command.
DS411-00001-4v1-E
11
MB89R118C
4. Requests/Responses
A request is sent from the reader/writer to the transponder. In replying to the request, the transponder sends
a response to the reader/writer.
Each request, and response, is transmitted in each single frame.
• Structure of requests and responses
A request consists of the following 5 fields :
• Flag
• Command code
• Parameter (required or optional depending on the command)
• Application data
• CRC
A response consists of the following 4 fields :
• Flag
• Parameter (required or optional depending on the command)
• Application data
• CRC
Each byte is transferred, beginning with the lowest bit. When two or more bytes are transferred, transfer
begins with the lowest one.
5. Operating Modes
The MB89R118C has the following 3 operating modes :
Each mode specifies a different mechanism for how the transponder returns a response in replying to a
request from the reader/writer :
• Addressed mode
The MB89R118C enters Addressed mode when the Address_flag is set to “1”.
In Addressed mode, a request includes a UID (the Address_flag is set to “1” simultaneously), and only the
transponder that matches the UID in the request returns a response. If no transponder that matches the UID
exists, a response is not returned.
• Non-Addressed mode
The MB89R118C enters Non-Addressed mode when the Address_flag is set to “0”.
In Non-Addressed mode, a request does not include a UID. The transponders that receive the request
execute processing and return its response in accordance with the requested command.
• Select mode
The MB89R118C enters Select mode when the Select_flag is set to “1”, and the Address_flag is set to “0”.
In Select mode, the request shall not contain a UID. When the transponders receive the command, only the
transponder in the select state executes processing and returns its response in accordance with the requested command.
12
DS411-00001-4v1-E
MB89R118C
6. Request Format
The following figure shows a typical example of the request data format, and the following table shows the
definition of request flag bits.
• Structure of the request frame
SOF
Flag
Command code
• Setting of Bit 1 to Bit 4
Bit
Flag name
1
Data_rate_flag
3
Inventory_flag
4
1/0
0
Sub-carrier_flag
2
Parameter
Protocol_Extension_flag
CRC
Data
EOF
State/Description
1-subcarrier selected
1
2-subcarrier selected (not supported)
0
Low data rate (6.62 kbps) selected
1
High data rate (26.48 kbps) selected
0
Command other than Inventory command selected
1
Inventory command selected
0
Protocol not extended
1
Protocol extended (RFU*)
* : Reserved for future use
Note : “Inventory_flag” of bit 3 is determined whether “Inventory command” (select “1”) or other command
(select “0”) is used.
• Setting of Bit 5 to Bit 8 (When Inventory command is selected [Inventory_flag = “1”])
Bit
Flag name
1/0
State/Description
5
AFI_flag
6
Nb_slots_flag
7
Option_flag
8
RFU*
0
AFI not set
1
AFI set (response when it is in accord with AFI of the
transponder)
0
16 slots
1
1 slot
0
Command option not supported
1
Command option supported (not supported)
0
Set to “0”
⎯
1
* : Reserved for future use
• Setting of Bit 5 to Bit 8 (When the command other than Inventory command is selected [Inventory_flag = “0”])
Bit
Flag name
1/0
State/Description
5
0
Request shall be executed according to the setting of
Address_flag.
1
Select mode (Request shall be executed only by the transponder in select state.) The Address_flag shall be set to “0”.
0
Non-Addressed mode (UID not included in the command)
1
Addressed mode (UID included in the command)
0
Command option not supported (for the command not
supporting the Option_flag)
1
Command option supported
0
Set to “0”
Select_flag
6
Address_flag
7
Option_flag
8
RFU*
1
⎯
* : Reserved for future use
DS411-00001-4v1-E
13
MB89R118C
7. Response Format
The following figure shows a typical example of the response data format, and the following table shows the
definition of the response flag and error codes.
If the Error_flag is set to “1”, an error code field is generated in the response. If the Error_flag is set to “0”,
this means no error, and If the Error_flag is set to “1”, this means any error generation.
• Structure of the response frame
Flag
SOF
• Response flag definitions
Bit
Flag name
Parameter
Data
1/0
Error not found
1
Error found
RFU*
0
Set to “0”
3
RFU*
0
Set to “0”
4
Extension_flag
0
Set to “0”
5
RFU*
0
Set to “0”
6
RFU*
0
Set to “0”
7
RFU*
0
Set to “0”
8
RFU*
0
Set to “0”
Error_flag
2
EOF
Description
0
1
CRC
* : Reserved for future use
• Error code definitions
Error code
“01”
The specific command is not supported. Example: Command code error
“02”
Cannot recognize the command. The number of blocks is over the limit. Example: Format error
“03”
Specific options are not supported.
“0F”
Other errors
“10”
The specified block cannot be used (or was not found).
“11”
The specified block has already been locked and cannot be locked again.
“12”
The specified block has already been locked, and its contents cannot be updated.
“13”
The specified block could not be programmed normally (a write verify error occurred).
“14”
The specified block could not be locked normally (a lock verify error occurred) .
Others
14
Meaning
Unused.
DS411-00001-4v1-E
MB89R118C
8. Anti-Collision Algorithm
The MB89R118C executes an anti-collision sequence loop based on an algorithm that complies with ISO/
IEC 15693-3.
The anti-collision algorithm is designed to examine the transponders located within reader/writer communication areas on the basis of UID.
The reader/writer issues an Inventory command to transponders, and some transponders return responses
while other transponders do not respond, according to the algorithm described in “10. Execution of Inventory
Command by a Transponder”.
9. Request Parameter
• Request Parameter Settings
Set the reader/writer as follows before issuing the Inventory command.
• The Nb_slots_flag (bit 6), which is a request flag, is set to the desired value :
“0” : 16 slots (for plural transponders)
“1” : 1 slot (for single transponder)
• A mask length and a mask value are added after the command code.
• The mask length represents the data length of the mask value in bits.
• The mask value is integer bytes of data, transmitted beginning with the lowest bit. If the mask data is not
a multiple of 8 (bits) in length, 0 is padded on the MSB side of the mask value so that the data is in units
of bytes.
The following figure shows an example of the mask value with padding. Since the mask length is 12 bits,
the mask value is padded with 4 bits on the MSB side so that the mask data is in units of bytes (2 bytes =
16 bits in this case).
If the AFI flag in the request flags is set in the format explained in “• Structure of the request frame of 6.
Request Format”, an AFI field is added to the format. The command ends with transmission of an EOF signal
as described in “1. Communication from Reader/Writer to Transponder”. Thereafter, processing in the first
slot starts immediately. To proceed to the next slot, the reader/writer sends an EOF signal.
• Format of the Command
SOF
Flag
Command code Optional AFI Mask length
8 bits
8 bits
8 bits
Mask value
CRC
0 to 64 bits
16 bits
8 bits
EOF
• Example of the Mask Value with Padding
LSB
MSB
DS411-00001-4v1-E
0000
0100 1100 1111
Pad
Mask value
15
MB89R118C
10. Execution of Inventory Command by a Transponder
A transponder returns a response to the reader/writer when its UID is equal to the value that consists of the
mask value and the number of slots. The mask value is sent in the Inventory command, and the number of
slots is determined by the number of times the EOF signal is transmitted.
• Algorithm for execution of processing by a transponder
The following figure shows the algorithm for the execution of processing by a transponder when an Inventory
command is received. The next figure shows the relationship between the UID and the mask value.
• Algorithm for Execution of Processing by a Transponder when Inventory Command
NbS
SN
LSB (value, n)
&
Slot_Frame
: Total number of slots (1 or 16)
: Current slot number
: The “n” least significant bits of value
: Concatenation operator
: SOF or EOF
SN = 0
Nb_slots_flag=1?
YES
NO
NbS = 1
SN_length=0
NbS = 16
SN_length=4
LSB (UID, SN_length + mask length) =
LSB (SN, SN_length) & LSB (mask,
mask length) ?
YES
Response transmission
NO
Wait (Slot_Frame)
Slot_Frame=SOF?
YES
NO
Slot_Frame=EOF?
NO
YES
End of processing
End of processing
SN < NbS-1
NO
YES
SN = SN + 1
16
End of processing
DS411-00001-4v1-E
MB89R118C
• Comparison of the mask value and the number of slots with the UID
[Inventory command (the side of a reader/writer)]
Padding
Inventory command includes the mask value and mask
length.
The mask value is padded with “0” into the higher bit side
so to make the byte-unit length (a multiple of 8 bits).
000•••
Mask value
(specified by the
Inventory command)
Mask length
If Inventory command is received, the slot
counter is reset to “0”.
Slot
counter
If EOF is received, the increment of the slot
counter is started by the transponder.
Number of
Mask value (no padding)
slots
The value is compared with the lowest bit in
UID of the transponder.
If the value is in accord with the mask value,
the response is returned by the transponder.
Ignored
Compared
Unique Identifier (UID)
MSB
DS411-00001-4v1-E
[Unique Identifier (the side of a transponder) ]
LSB
17
MB89R118C
11. Anti-Collision Sequence
• Execution of anti-collision sequence
The following steps summarize the main cases that can occur during a typical anti-collision sequence where
the number of slots is 16.
1) The reader/writer sends an Inventory command.
The Nb_slots_flag bit of the request flags is set to “0” to specify the number of slots.
2) In slot 0, transponder 1 transmits its response in the time t1_a from the detection of the rising edge of the
EOF. In this case no collision occurs and the UID of transponder is received and registered by the reader/
writer.
3) The reader/writer sends an EOF signal to switch to the next slot in the time t2_a after the response 1.
4) In slot 1, transponder 2 and transponder 3 transmit their response in the time t1_a from the detection of
the rising edge of the EOF. In this case, the reader/writer cannot recognize the UIDs of the two
transponders because the collision occurs, and the reader/writer remembers that a collision was
detected in slot 1.
5) The reader/writer sends an EOF signal to switch to the next slot in the time t2_a after the responses.
6) In slot 2, no transponder transmits a response. The reader/writer does not detect any response, and
sends an EOF signal to switch to the next slot in the time t3_a from the detection of the rising edge of
the EOF.
7) In slot 3, transponder 4 and transponder 5 transmit their response in the time t1_a from the detection of
the rising edge of the EOF, and another collision occurs.
8) The reader/writer sends a request (for example, a Read Single Block command, described later) to the
transponder 1, which UID was already correctly received.
9) All transponders detect an SOF signal and exit the anti-collision sequence. In this case, since the request
is addressed to transponder 1 (Addressed mode), only transponder 1 transmits its response.
10) All transponders are ready to receive another request from the reader/writer. If the Inventory command is
sent again, the anti-collision sequence starts from slot 0.
Note : t1_a, t2_a, t3_a are specified in “12. Timing definitions”.
18
DS411-00001-4v1-E
MB89R118C
• Example of Anti-Collision Sequence
Slot 0
Slot_Counter (1)
Reader/writer
SOF
Inventory
command
EOF
Slot 1
(3)
EOF
(2)
(4)
Response 1
Response 2
MB89R118C
Response 3
Timing
t1_a
Status
t1_a
No collision
Slot 2
Slot_Counter (5)
Reader/writer
t2_a
EOF
t2_a
Collision
Slot 3
(6)
(7)
EOF
EOF
Response 4
MB89R118C
Response 5
Timing
t3_a
Status
t1_a
No response
Slot_Counter
t2_a
Collision
(8)
Reader/writer
SOF
Command
(to Transponder1)
(9)
EOF
Response
(Transponder1)
MB89R118C
Timing
t3_a
t1_a
Status
DS411-00001-4v1-E
19
MB89R118C
12. Timing definitions
(1) Period during which the MB89R118C waits for the start of response transmission after an EOF
signal transmitted from the reader/writer : t1_a
After detection of an EOF signal sent from the reader/writer, MB89R118C must wait for a certain time (t1_a)
before sending a response to the reader/writer. t1_a begins at the rising edge of the EOF pulse, and it is
defined as follows. The minimum value is 4320/fc (318.6 μs), the nominal value is 4352/fc (320.9 μs), and
the maximum value is 4384/fc (323.3 μs).
Even if the 10% ASK modulated signal from the reader/writer is detected within the time t1_a, the transponder
ignore the signal and wait for further time t1_a before starting to transmit.
(2) Period during which the MB89R118C ignores modulated signals after an EOF signal transmitted
from the reader/writer : tmit
After detection of an EOF signal sent from the reader/writer, MB89R118C must ignore the 10% ASK modulated signals from the reader/writer for a time (tmit).
tmit begins at the rising edge of the EOF pulse. The minimum value of tmit is defined as 4384/fc (323.3 μs)
+ tnrt.
In the above expression, tnrt stands for the response time of MB89R118C.
(3) Period during which the reader/writer waits before sending a request : t2_a
When the reader/writer has received a response from the transponder to a previous request other than
Inventory and Stay Quiet command, it shall wait a time t2_a before sending a subsequent request. The
minimum value of t2_a is 309.2 μs. It is defined in ISO/IEC 15693-3. And ISO/IEC 18000-3 (Mode 1) .
(4) Period during which the reader/writer waits before sending a request during execution of the Inventory command : t2inv
While an Inventory command is being executed, the reader/writer sends an EOF signal when it shifts to the
next slot. In this case, the wait time is defined as follows depending on whether transponders return responses :
-
Wait time applied when the reader/writer has received one or more responses : t2invwr
It is defined in ISO/IEC 15693-3. And ISO/IEC 18000-3 (Mode 1) that when the reader/writer has received
one or more responses, the reader/writer must wait until responses from the transponders have been
completed (that is, the reader/writer receives an EOF signal or tnrt passes). After that, the reader/writer
must wait until t2_a passes before sending an EOF signal to switch to the next slot.
-
Wait time applied when the reader/writer has not received any responses : t3_a
When the reader/writer has not received any responses from the MB89R118C, the reader/writer must
wait until t3_a passes before sending an EOF signal. In this case, t3_a begins at the rising edge of the
EOF pulse that was sent previously. The minimum value of t3_a is defined as shown in the following table.
MB89R118C does not support the minimum value of t3_a as “4384/fc (323.3 μs) + tsof” when the reader/
writer sends a 100% modulated EOF, which is defined in ISO/IEC 15693-3 and ISO/IEC 18000-3 (Mode 1).
(a) If the reader/writer sends a ASK10% modulated EOF, the minimum value of t3_a (ASK10%) is “4384/
fc (323.3 μs + tnrt')
(b) If the reader/writer sends a ASK100% modulated EOF, the minimum value of t3_a (ASK100%) is
“4384/fc (323.3 μs + tsof')
tnrt: The nominal response time of transponder
tsof: The time for transponder to transmit a SOF to the reader/writer
20
DS411-00001-4v1-E
MB89R118C
• t3_a for ASK10% and ASK100% signal
Reader/Writer
SOF
Inventory
command
New command
(or EOF signal)
EOF
No response
MB89R118C
t1_a
t3_a (ASK100 %)
t3_a (ASK10 %)
Timing
tsof
tnrt
Possible to receive
ASK 10 % signal
Ignore ASK 10 % signal
MB89R118C
ASK signal handling
Reset t1_a
after receiving
ASK 100 % signal
Ignore
ASK 100 %
signal
Possible to receive
ASK 100 % signal
• Timing specification
Min
Typ
Max
t1_a
4320/fc (318.6 μs)
4352/fc (320.9 μs)
4384/fc (323.3 μs)
tmit
4384/fc (323.3 μs) + tnrt
⎯
⎯
t2_a
4192/fc (309.2 μs)
⎯
⎯
t2invwr
t2_a + tnrt
⎯
⎯
t3_a (ASK10%)
4384/fc (323.3 μs) + tnrt
⎯
⎯
t3_a (ASK100%)
4384/fc (323.3 μs) + tsof
⎯
⎯
tnrt
tsof
DS411-00001-4v1-E
⎯
Low data rate
High data rate
Fast Low data rate
Fast High data rate
: 15708.16 ms
: 3927.04 ms
: 7854.08 ms
: 1963.52 ms
⎯
⎯
Low data rate
High data rate
Fast Low data rate
Fast High data rate
:
:
:
:
⎯
604.16
151.04
302.08
75.52
ms
ms
ms
ms
21
MB89R118C
■ COMMAND LIST
All Mandatory and Optional commands defined by ISO/IEC 15693-3 are supported.
The following Custom commands are supported :
• EAS command
: Using for preventing the theft of goods and goods-monitoring
• Write EAS command
: Writing data to the EAS bit
• Read Multiple Blocks Unlimited command : Enable to read FRAM area of up to 2048 bytes in a lump
• Fast command
: Respond at double speed compared to ISO commands
• Command list
Command
code
22
Command name
Command
Type
Details
“01H”
Inventory
Mandatory Execute the anti-collision sequence and get UID.
“02H”
Stay Quiet
Mandatory Enter the Quiet state
“20H”
Read Single Block
Optional
Read the requested 1 block data in the user area/system
area
“21H”
Write Single Block
Optional
Write the requested 1 block data in the user area
“22H”
Lock Block
Optional
Lock (disable to write) the requested 1 block in the user
area
“23H”
Read Multiple Blocks
Optional
Read the requested 1 or 2 blocks data in the user area/
system area
“24H”
Write Multiple Blocks
Optional
Write the requested 1 or 2 blocks data in the user area
“25H”
Select
Optional
Enter the select (communication selected) state
“26H”
Reset to Ready
Optional
Enter the ready (communication enabled) state
“27H”
Write AFI
Optional
Write AFI (Application Family Identifier) data into FRAM.
“28H”
Lock AFI
Optional
Lock AFI data (disable to write)
“29H”
Write DSFID
Optional
Write DSFID (Data Storage Format Identifier) data into
FRAM
“2AH”
Lock DSFID
Optional
Lock DSFID (Data Storage Format Identifier) data (disable
to write)
“2BH”
Get System Information
Optional
Read the system information value (UID, DSFID, AFI,
number of bytes per block, number of blocks in user area,
and IC information)
“2CH”
Get Multiple Block
Security Status
Optional
Read the block security status stored in system area.
“A0H”
EAS
Custom
When EAS bit is “1”, reply response code 6 times.
“A1H”
Write EAS
Custom
Write EAS data (1 bit). Data “1” validates anti-theft/goodsmonitoring, and data “0” invalidates them.
“A5H”
Read Multiple Blocks
Unlimited
Custom
Read the specified data of up to 256 blocks in the user
area/system area.
“B1H”
Fast Inventory
Custom
Fast response Inventory command
“C0H”
Fast Read Single Block
Custom
Fast response Read Single Block command
“C1H”
Fast Write Single Block
Custom
Fast response Write Single Block command
“C3H”
Fast Read Multiple Blocks
Custom
Fast response Read Multiple Blocks command
“C4H”
Fast Write Multiple Blocks
Custom
Fast response Write Multiple Blocks command
“D1H”
Fast Write EAS
Custom
Fast response Write EAS command
“D5H”
Fast Read Multiple Blocks
Unlimited
Custom
Fast response Read Multiple Blocks Unlimited command
DS411-00001-4v1-E
MB89R118C
■ COMMAND DESCRIPTION
1. Description of Mandatory Commands
1-1. Inventory command
The Inventory command executes the anti-collision sequence.
If an error is detected during execution of this command, a response indicating the error shall be not returned.
The Inventory_flag (bit 3) must be set to “1”.
When the AFI_flag (bit 5) in the Inventory command frame is set as “1”, the response shall be returned in
the following cases.
• The AFI value of the transponder is in accord with the optional AFI value.
• The 4 bits value MSB of the Optional AFI is “0H”, and the 4 bits value LSB of the Optional AFI is in
accord with the 4 bits value LSB of the transponder.
• The 4 bits value LSB of the Optional AFI is “0H”, and the 4 bits value MSB of the Optional AFI is in
accord with the 4 bits value MSB of the transponder.
• The optional AFI value is “00H”.
• Request
[Request from the reader/writer to the transponder]
Command
SOF
Flag
Optional AFI
(Inventory)
8 bits
8 bits (“01H”)
8 bits
Mask length
Mask value
CRC
8 bits
0 to 64 bits
16 bits
EOF
• Response
[Response from the transponder to the reader/writer]
SOF
Flag
DSFID
8 bits (“00H”)
8 bits
UID
CRC
64 bits
16 bits
EOF
1-2. Stay Quiet command
On receiving the Stay Quiet command, the transponder enters the quiet state. The transponder does not
return any responses, including an error indication.
In the quiet state, the transponder does not execute any request for which the Inventory_flag (bit 3) is set to
“1” and executes only a command for which the Address_flag (bit 6) is set to “1”.
The transponder exits the quiet state only in the following cases:
• The transponder enters the power-off state.
• The transponder receives the Select command and enters the select state.
• The transponder receives the Reset to Ready command and enters the ready state.
• Request
[Request from the reader/writer to the transponder]
Command
SOF
Flag
(Stay Quiet)
8 bits
8 bits (“02H”)
UID (necessary)
CRC
64 bits
16 bits
EOF
• Response
[Response from the transponder to the reader/writer]
No response
DS411-00001-4v1-E
23
MB89R118C
2. Description of Optional Commands
2-1. Read Single Block command
On receiving the Read Single Block command, the transponder reads the data stored in the specified singleblock to the reader/writer.
If the Option_flag (bit 7) is “1”, the transponder adds block security status information in the response. If the
Option_flag (bit 7) is “0”, the transponder returns only the data in the specified block to the reader/writer.
• Request
[Request from the reader/writer to the transponder]
Command
UID
SOF
Flag
(Read Single Block)
(Addressed mode)
8 bits (“20H”)
8 bits
Block number
CRC
8 bits
16 bits
64 bits
EOF
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
(2) When Error_flag not set
SOF
Flag
EOF
Block security status (option)
Data
CRC
8 bits
64 bits
16 bits
8 bits (“00H”)
EOF
2-2. Write Single Block command
On receiving the Write Single Block command, the transponder writes the single block data included in the
request to the specified block.
The transponder performs verification after writing and returns an error code if the writing has failed.
If the Option_flag (bit 7) is “0”, the transponder shall return its response when it has completed the write
operation starting after “t1nom (320.9 μs) + a multiple of 4096/fc (302.1 μs)” with total tolerance of ± 32/fc
(2.4 μs) and latest within 20 ms. If it is “1”, transponder shall wait for the reception of an EOF from the reader/
writer and upon such reception still return its response (However, if an EOF is not sent within 38 ms, the
time-out occurs and the transponder can receive another command).
• Request
[Request from the reader/writer to the transponder]
Command
UID
SOF Flag
(Write Single Block)
(Addressed mode)
8 bits
24
8 bits (“21H”)
64 bits
Block
number
Data
CRC
8 bits
64 bits
16 bits
EOF
DS411-00001-4v1-E
MB89R118C
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
(2) When Error_flag not set
SOF
Flag
CRC
8 bits (“00H”)
16 bits
EOF
EOF
2-3. Lock Block command
On receiving the Lock Block command, the transponder locks (write disable) permanently the data stored
in one specified single block.
The transponder performs verification after writing and returns an error code if the writing has failed.
If the Option_flag (bit 7) is “0”, the transponder shall return its response when it has completed the lock
operation starting after “t1nom (320.9 μs) + a multiple of 4096/fc (302.1 μs)” with total tolerance of ± 32/fc
(2.4 μs) and latest within 20 ms. If it is “1”, transponder shall wait for the reception of an EOF from the reader/
writer and upon such reception still return its response. (However, if an EOF is not sent within 38 ms, the
time-out occurs and the transponder can receive another command.)
Once the Lock Block command has been received, data in the locked block cannot be changed by any
command.
• Request
[Request from the reader/writer to the transponder]
Command
UID
SOF
Flag
(Lock Block)
(Addressed mode)
8 bits
8 bits (“22H”)
64 bits
Block number
CRC
8 bits
16 bits
EOF
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
(2) When Error_flag not set
SOF
DS411-00001-4v1-E
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
Flag
CRC
8 bits (“00H”)
16 bits
EOF
EOF
25
MB89R118C
2-4. Read Multiple Blocks Command
On receiving the Read Multiple Blocks command, the transponder reads the data stored in the specified
successive blocks to the reader/writer.
Up to 2 blocks of data can be read for one request.
If the Option_flag (bit 7) is “1”, the transponder adds block security status information in the response. If the
Option_flag (bit 7) is “0”, the transponder returns only the data in the specified blocks to the reader/writer.
The value of the “number of blocks” field specified in the request is the expected number of blocks minus 1.
Setting the number of blocks to “01H” makes a request to read 2 blocks. Setting the number of blocks to “00H”
makes a request to read 1 block (the request having the same effect as the Read Single Block command).
• Request
[Request from the reader/writer to the transponder]
Command
UID
SOF
Flag
(Read Multiple Blocks) (Addressed mode)
8 bits
8 bits (“23H”)
First block
number
Number of
blocks
CRC
8 bits
8 bits
16 bits
64 bits
EOF
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
(2) When Error_flag not set
SOF
Flag
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
Block security status (option)
Data
CRC
8 bits
64 bits
16 bits
8 bits (“00H”)
EOF
EOF
Repeated as required
2-5. Write Multiple Blocks Command
On receiving the Write Multiple Blocks command, the transponder writes the successive multiple-block data
included in the request to the specified blocks.
Up to 2 blocks of data can be written for one request.
The transponder performs verification after writing and returns an error code if the writing has failed. The
number of blocks specified in the Write Multiple Blocks command is similar to the number of blocks specified
in the Read Multiple Blocks command. The value of the number of blocks field specified in the Write Multiple
Blocks command is obtained by subtracting 1 from the number of the expected blocks to be written.
Setting the number of blocks to “01H” makes a request to write 2 blocks. Setting the number of blocks to
“00H” makes a request to write 1 block (the request having the same effect as the Write Single Block
command).
If at least one of the blocks specified by the request is locked, the transponder does not write any data and,
instead, returns an error code.
If the Option_flag (bit 7) is “0”, the transponder shall return its response when it has completed the write
operation starting after “t1nom (320.9 μs) + a multiple of 4096/fc (302.1 μs)” with total tolerance of ± 32/fc
(2.4 μs) and latest within 20 ms. If it is “1”, transponder shall wait for the reception of an EOF from the reader/
writer and upon such reception still return its response (However, if an EOF is not sent within 38 ms, the
time-out occurs and the transponder can receive another command) .
26
DS411-00001-4v1-E
MB89R118C
• Request
[Request from the reader/writer to the transponder]
SOF
Flag
8 bits
Command (Write
UID
Multiple Blocks) (Addressed mode)
8 bits (“24H”)
First block
number
Number of
blocks
Data
CRC
8 bits
8 bits
64 bits
or
128 bits
16 bits
64 bits
EOF
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
(2) When Error_flag not set
SOF
Flag
CRC
8 bits (“00H”)
16 bits
EOF
EOF
2-6. Select command
Of the transponders that received the Select command, only the transponder whose UID matches the UID
included in the request enters the select state and returns a response.
The other transponders, whose UIDs do not match the UID in the request, enter the ready state without
returning any response. The Select command is used only in Addressed mode.
• Request
[Request from the reader/writer to the transponder]
SOF
Flag
Command (Select) UID (necessary)
8 bits
8 bits (“25H”)
64 bits
CRC
EOF
16 bits
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
(2) When Error_flag not set
SOF
DS411-00001-4v1-E
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
Flag
CRC
8 bits (“00H”)
16 bits
EOF
EOF
27
MB89R118C
2-7. Reset to Ready command
On receiving the Reset to Ready command, the transponder enters the ready state.
• Request
[Request from the reader/writer to the transponder]
SOF
Flag
Command (Reset to Ready)
UID (Addressed mode)
CRC
64 bits
16 bits
8 bits (“26H”)
8 bits
EOF
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
(2) When Error_flag not set
SOF
Flag
CRC
8 bits (“00H”)
16 bits
EOF
EOF
2-8. Write AFI command
On receiving the Write AFI command, the transponder writes the data of AFI to FRAM.
The transponder performs verification after writing and returns an error code if the writing has failed.
If the Option_flag (bit 7) is “0”, the transponder shall return its response when it has completed the write
operation starting after “t1nom (320.9 μs) + a multiple of 4096/fc (302.1 μs)” with total tolerance of ± 32/fc
(2.4 μs) and latest within 20 ms. If it is “1”, transponder shall wait for the reception of an EOF from the reader/
writer and upon such reception still return its response (However, if an EOF is not sent within 38 ms, the
time-out occurs and the transponder can receive another command) .
• Request
[Request from the reader/writer to the transponder]
SOF
Flag
Command (Write AFI) UID (Addressed mode)
8 bits
8 bits (“27H”)
64 bits
AFI
CRC
EOF
8 bits
16 bits
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
(2) When Error_flag not set
SOF
28
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
Flag
CRC
8 bits (“00H”)
16 bits
EOF
EOF
DS411-00001-4v1-E
MB89R118C
2-9. Lock AFI command
On receiving the Lock AFI command, the transponder locks (write disable) permanently the data of AFI.
The transponder performs verification after writing and returns an error code if the writing has failed.
If the Option_flag (bit 7) is “0”, the transponder shall return its response when it has completed the lock
operation starting after “t1nom (320.9 μs) + a multiple of 4096/fc (302.1 μs)” with total tolerance of ±32/fc
(2.4 μs) and latest within 20 ms. If it is “1”, transponder shall wait for the reception of an EOF from the reader/
writer and upon such reception still return its response (However, if an EOF is not sent within 38 ms, the
time-out occurs and the transponder can receive another command) .
Once the Lock AFI command has been received, the data of AFI cannot be changed by the Write AFI
command.
• Request
[Request from the reader/writer to the transponder]
SOF
Flag
Command (Lock AFI) UID (Addressed mode)
8 bits (“28H”)
8 bits
CRC
64 bits
EOF
16 bits
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
(2) When Error_flag not set
SOF
Flag
CRC
8 bits (“00H”)
16 bits
EOF
EOF
2-10. Write DSFID command
On receiving the Write DSFID command, the transponder writes the data of DSFID to FRAM.
The transponder performs verification after writing and returns an error code if the writing has failed.
If the Option_flag (bit 7) is “0”, the transponder shall return its response when it has completed the write
operation starting after “t1nom (320.9 μs) + a multiple of 4096/fc (302.1 μs)” with total tolerance of ± 32/fc
(2.4 μs) and latest within 20 ms. If it is “1”, transponder shall wait for the reception of an EOF from the reader/
writer and upon such reception still return its response (However, if an EOF is not sent within 38 ms, the
time-out occurs and the transponder can receive another command) .
• Request
[Request from the reader/writer to the transponder]
SOF
Flag
Command (Write DSFID) UID (Addressed mode)
8 bits
DS411-00001-4v1-E
8 bits (“29H”)
64 bits
DSFID
CRC
8 bits
16 bits
EOF
29
MB89R118C
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
(2) When Error_flag not set
SOF
Flag
CRC
8 bits (“00H”)
16 bits
EOF
EOF
2-11. Lock DSFID command
On receiving the Lock DSFID command, the transponder locks (write disable) permanently the data of DSFID.
The transponder performs verification after writing and returns an error code if the writing has failed.
If the Option_flag (bit 7) is “0”, the transponder shall return its response when it has completed the lock
operation starting after “t1nom (320.9 μs) + a multiple of 4096/fc (302.1 μs)” with total tolerance of ± 32/fc
(2.4 μs) and latest within 20 ms. If it is “1”, transponder shall wait for the reception of an EOF from the reader/
writer and upon such reception still return its response (However, if an EOF is not sent within 38 ms, the
time-out occurs and the transponder can receive another command) .
Once the Lock DSFID command has been received, the data of DSFID cannot be changed by the any
command.
• Request
[Request from the reader/writer to the transponder]
SOF
Flag
Command (Lock DSFID)
8 bits
UID (Addressed mode)
CRC
64 bits
16 bits
8 bits (“2AH”)
EOF
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
(2) When Error_flag not set
SOF
30
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
Flag
CRC
8 bits (“00H”)
16 bits
EOF
EOF
DS411-00001-4v1-E
MB89R118C
2-12. Get System Information command
On receiving the Get System Information command, the transponder reads the chip information of UID, AFI,
DSFID, and so on to the reader/writer as a response.
• Request
[Request from the reader/writer to the transponder]
SOF
Flag
Command (Get System Information) UID (Addressed mode)
8 bits
8 bits (“2BH”)
64 bits
CRC
EOF
16 bits
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
(2) When Error_flag not set
SOF
Flag
Information flag
8 bits (“00H”)
8 bits
UID
DSFID
AFI
64 bits
8 bits
8 bits
Memory size IC reference
16 bits
8 bits
EOF
CRC
EOF
16 bits
The followings show the definitions of the Information flag and the memory size information (transponder
memory size information) included in the response of the Get System Information command. However, the
size of blocks and number of blocks in the user area shown in the memory size information about a transponder indicate one less than the actual value.
• Definition of information flag
Bit
Flag name
State
Description
0
DSFID is not supported or does not exist.
1
DSFID is supported or exists.
0
AFI is not supported or does not exist.
1
AFI is supported or exists.
0
Memory size information is not supported or does not exist.
1
Memory size information is supported or exists.
0
IC reference information is not supported or does not exist.
1
IC reference information is supported or exists.
1
DSFID
2
AFI
3
Memory size
4
IC reference
5
RFU*
⎯
6
RFU*
⎯
7
RFU*
⎯
8
RFU*
⎯
Set to “0”
* : Reserved for future use
Note : For MB89R118C, set “0FH” (set “1” for bit 1 to bit 4 and set “0” for bit 5 to bit 8) .
DS411-00001-4v1-E
31
MB89R118C
• Memory size information about a transponder
MSB
LSB
16
14 13
RFU*
9 8
Size of blocks (Number of bytes in 1 block)
1
Number of blocks in
the user area
* : Reserved for future use
Note : The memory size of the MB89R118C which consists of 250 blocks (8 bytes per block) in the user area,
the memory size information is hexadecimal “07F9H”.
2-13. Get Multiple Block Security Status Command
On receiving the Get Multiple Block Security Status command, the transponder reads the block security
status stored in a system area to the reader/writer as a response.
Up to 64 blocks of data can be read for one request. The number of blocks specified in this request must be
the value that is 1 block less than the actual number of the blocks whose security status is to be obtained.
The first block number specified in this request must be a multiple of 8.
• Request
[Request from the reader/writer to the transponder]
Command
UID
SOF
Flag
(Get Multiple Block
(Addressed mode)
Security Status)
8 bits
8 bits (“2CH”)
First block
number
Number of
blocks
CRC
8 bits
8 bits
16 bits
64 bits
EOF
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
(2) When Error_flag not set
SOF
Flag
8 bits (“00H”)
32
Block security status
CRC
8 bits
(repeated as required)
16 bits
EOF
EOF
DS411-00001-4v1-E
MB89R118C
3. Custom Command
The IC manufacturing code is required to use a Custom command. The IC manufacturing code for the
MB89R118C is “08H”.
3-1. EAS command
On EAS command reception, the transponder returns the response code “5AH” repeated 6 times after the
specified flag (“00H”) if the EAS bit is “1” or returns no response if the EAS bit is “0”. The EAS command can
be executed only when the transponder is in the ready or select state.
• Request
[Request from the reader/writer to the transponder]
SOF
Flag
Command (EAS)
IC manufacturer code
(necessary)
CRC
8 bits
8 bits (“A0H”)
8 bits (“08H”)
16 bits
EOF
• Response
[Response from the transponder to the reader/writer]
SOF
Flag
Response code
8 bits (“00H”)
CRC
48 bits (6 times repeat of “5AH”)
EOF
16 bits
3-2. Write EAS command
On Write EAS command reception, the transponder writes the EAS bit to FRAM.
The transponder performs verification after writing and returns an error code if the writing has failed.
The EAS bit must be set to “00H” to cancel anti-theft or goods-monitoring mode. The bit must be set to “01H”
to set up the goods-monitoring mode as the EAS data.
If the Option_flag (bit 7) is “0”, the transponder shall return its response when it has completed the write
operation starting after “t1nom (320.9 μs) + a multiple of 4096/fc (302.1 μs)” with total tolerance of ±32/fc
(2.4 μs) and latest within 20 ms. If it is “1”, transponder shall wait for the reception of an EOF from the reader/
writer and upon such reception still return its response (However, if an EOF is not sent within 38 ms, the
time-out occurs and the transponder can receive another command) .
• Request
[Request from the reader/writer to the transponder]
Command
IC manufacturer
UID
SOF Flag
(Write EAS) code (necessary) (Addressed mode)
8 bits 8 bits (“A1H”)
8 bits (“08H”)
64 bits
Data
CRC
8 bits (“00H” or “01H”)
16 bits
EOF
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
(2) When Error_flag not set
SOF
DS411-00001-4v1-E
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
Flag
CRC
8 bits (“00H”)
16 bits
EOF
EOF
33
MB89R118C
3-3. Read Multiple Blocks Unlimited Command
On receiving the Read Multiple Blocks Unlimited command, the transponder reads the data stored in the
specified successive blocks to the reader/writer as a response.
Up to 256 blocks of data can be read for one request.
If the Option_flag (bit 7) is “1”, the transponder adds block security status information in the response. If the
Option_flag (bit 7) is “0”, the transponder returns only the data in the specified blocks to the reader/writer.
The value of the “number of blocks” field specified in the request is the expected number of blocks minus 1.
Setting the number of blocks to “06H” makes a request to read 7 blocks. Up to “FFH” blocks can be set. (Note
that the maximum number of blocks is changed by setting the leading block number.)
• Request
[Request from the reader/writer to the transponder]
UID
Command
First block Number
IC manufacturer
(Addressed
SOF Flag
(Read Multiple
number of blocks
code (necessary)
mode)
Blocks Unlimited)
8 bits
8 bits (“A5H”)
8 bits (“08H”)
64 bits
8 bits
8 bits
CRC
EOF
16 bits
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
(2) When Error_flag not set
SOF
Flag
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
EOF
Block security status(option)
Data
CRC
8 bits
64 bits
16 bits
8 bits (“00H”)
EOF
Repeated as required
3-4. Fast Inventory Command
The Fast Inventory command is the same as the Inventory Command that executes the anti-collision sequence.
The data rate in the response is twice as defined in ISO/IEC 15693.
Even though an error is detected during execution of this command, a response indicating the error is not
returned.
The Inventory_flag (bit 3) must be set to “1”.
When the AFI_flag (bit 5) in the Inventory command frame is set as “1”, the response is returned in the
following cases.
• The AFI value of the transponder is in accord with the optional AFI value.
• The 4 bits value MSB of the Optional AFI is “0H”, and the 4 bits value LSB of the Optional AFI is in
accord with the 4 bits value LSB of the transponder.
• The 4 bits value LSB of the Optional AFI is “0H”, and the 4 bits value MSB of the Optional AFI is in
accord with the 4 bits value MSB of the transponder.
• The optional AFI value is “00H”.
34
DS411-00001-4v1-E
MB89R118C
• Request
[Request from the reader/writer to the transponder]
Command
IC manufacturer
SOF Flag
(Fast Inventory) code (necessary)
8 bits
8 bits (“B1H”)
Optional
AFI
Mask
length
Mask
value
CRC
8 bits
8 bits
0 to 64 bits
16 bits
8 bits (“08H”)
EOF
• Response
[Response from the transponder to the reader/writer]
SOF
Flag
DSFID
8 bits (“00H”)
8 bits
UID
CRC
64 bits
16 bits
EOF
3-5. Fast Read Single Block Command
The Fast Read Single Block command is the same as the Read Single Block command that reads the data
stored in the specific single-block. The data rate in the response is twice as defined in ISO/IEC 15693.
If the Option_flag (bit 7) is “1”, the transponder adds block security status information in the response. If the
Option_flag (bit 7) is “0”, the transponder returns only the data in the specified block to the reader/writer.
• Request
[Request from the reader/writer to the transponder]
Command
IC manufacturer
UID
Block
SOF Flag
(Fast Read Single Block) code (necessary) (Addressed mode) number
8 bits
8 bits (“C0H”)
8 bits (“08H”)
64 bits
8 bits
CRC
EOF
16 bits
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
(2) When Error_flag not set
SOF
Flag
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
EOF
Block security status(option)
Data
CRC
8 bits
64 bits
16 bits
8 bits (“00H”)
EOF
3-6. Fast Write Single Block Command
The Fast Write Single Block command is the same as the Write Single Block command that writes the singleblock data included in the request. The data rate in the response is twice as defined in ISO/IEC 15693.
The transponder performs verification after writing and returns an error code if the writing has failed.
If the Option_flag (bit 7) is “0”, the transponder shall return its response when it has completed the write
operation starting after “t1nom (320.9 μs) + a multiple of 4096/fc (302.1 μs)” with total tolerance of ±32/fc
(2.4 μs) and latest within 20 ms. If it is “1”, transponder shall wait for the reception of an EOF from the reader/
writer and upon such reception still return its response (However, if an EOF is not sent within 38 ms, the
time-out occurs and the transponder can receive another command) .
DS411-00001-4v1-E
35
MB89R118C
• Request
[Request from the reader/writer to the transponder]
SOF
Flag
8 bits
UID
Command (Fast
IC manufacturer
(Addressed
Write Single Block) code (necessary)
mode)
8 bits (“C1H”)
8 bits (“08H”)
64 bits
Block
number
Data
CRC
8 bits
64 bits
16 bits
EOF
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
(2) When Error_flag not set
SOF
Flag
CRC
8 bits (“00H”)
16 bits
EOF
EOF
3-7. Fast Read Multiple Blocks Command
The Fast Read Multiple Blocks command is the same as the Read Multiple Blocks command that reads the
data of the specified successive blocks.
Up to 2 blocks of data can be read for one request. The data rate in the response is twice as defined in ISO/
IEC 15693.
If the Option_flag (bit 7) is “1”, the transponder adds block security status information in the response. If the
Option_flag (bit 7) is “0”, the transponder returns only the data in the specified blocks to the reader/writer.
The value of the “number of blocks” field specified in the request is the expected number of blocks minus 1.
Setting the number of blocks to “01H” makes a request to read 2 blocks. Setting the number of blocks to “00H”
makes a request to read 1 block (the request having the same effect as the Fast Read Single Block command).
• Request
[Request from the reader/writer to the transponder]
UID
Command
IC manufacturer
(Addressed
SOF
Flag
(Fast Read
code (necessary)
mode)
Multiple Blocks)
8 bits
8 bits (“C3H”)
8 bits (“08H”)
64 bits
First
block
number
Number
of
blocks
CRC
8 bits
8 bits
16 bits
EOF
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
(2) When Error_flag not set
SOF
Flag
8 bits (“00H”)
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
EOF
Block security status(option)
Data
CRC
8 bits
64 bits
16 bits
EOF
Repeated as required
36
DS411-00001-4v1-E
MB89R118C
3-8. Fast Write Multiple Blocks Command
The Fast Write Multiple Blocks command is the same as the Write Multiple Blocks command that writes the
successive multiple-block data included in the request.
Up to 2 blocks of data can be written for one request. The data rate in the response is twice as defined in
ISO/IEC 15693.
The transponder performs verification after writing and returns an error code if the writing has failed. The
number of blocks specified in the Fast Write Multiple Blocks command is similar to the number of blocks
specified in the Read Multiple Blocks command. The value of the number of blocks field specified in the Fast
Write Multiple Blocks command is obtained by subtracting 1 from the number of the expected blocks to be
written.
Setting the number of blocks to “01H” makes a request to write 2 blocks. Setting the number of blocks to
“00H” makes a request to write 1 block (the request having the same effect as the Fast Write Single Block
command).
If at least one of the blocks specified by the request is locked, the transponder does not write any data and,
instead, returns an error code.
If the Option_flag (bit 7) is “0”, the transponder shall return its response when it has completed the write
operation starting after “t1nom (320.9 μs) + a multiple of 4096/fc (302.1 μs)” with total tolerance of ±32/fc
(2.4 μs) and latest within 20 ms. If it is “1”, transponder shall wait for the reception of an EOF from the reader/
writer and upon such reception still returns its response (However, if an EOF is not sent within 38 ms, the
time-out occurs and the transponder can receive another command) .
• Request
[Request from the reader/writer to the transponder]
First
UID
Command
Number
IC manufacturer
(Addressed block
SOF Flag
(Fast Write
of blocks
code
number
mode)
Multiple Blocks)
8 bits
8 bits (“C4H”)
8 bits (“08H”)
64 bits
8 bits
8 bits
Data
CRC EOF
64 bits
or
16 bits
128 bits
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
(2) When Error_flag not set
SOF
DS411-00001-4v1-E
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
Flag
CRC
8 bits (“00H”)
16 bits
EOF
EOF
37
MB89R118C
3-9. Fast Write EAS Command
The Fast Write EAS command is the same as Write EAS command that writes the EAS bit to FRAM. The
data rate in the response is twice as defined in ISO/IEC 15693.
The transponder performs verification after writing and returns an error code if the writing has failed.
The EAS bit must be set to “00H” to cancel anti-theft or goods-monitoring mode. The bit must be set to “01H”
to set up the goods-monitoring mode.
If the Option_flag (bit 7) is “0”, the transponder shall return its response when it has completed the write
operation starting after “t1nom (320.9 μs) + a multiple of 4096/fc (302.1 μs)” with total tolerance of ±32/fc
(2.4 μs) and latest within 20 ms. If it is “1”, transponder shall wait for the reception of an EOF from the reader/
writer and upon such reception still return its response (However, if an EOF is not sent within 38 ms, the
time-out error occurs and the transponder can receive another command) .
• Request
[Request from the reader/writer to the transponder]
IC manufacturer
UID
Command
code
SOF Flag
(Addressed mode)
(Fast Write EAS)
(necessary)
8 bits
8 bits (“D1H”)
8 bits (“08H”)
64 bits
Data
CRC
EOF
8 bits (“00H” or “01H”) 16 bits
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
(2) When Error_flag not set
SOF
Flag
CRC
8 bits (“00H”)
16 bits
EOF
EOF
3-10. Fast Read Multiple Blocks Unlimited Command
The Fast Read Multiple Blocks Unlimited command is the same as the Read Multiple Blocks Unlimited
command that reads the data of the specified successive blocks.
Up to 256 blocks of data can be read for one request. The data rate in the response is twice as defined in
ISO/IEC 15693.
If the Option_flag (bit 7) is “1”, the transponder adds block security status information in the response. If the
Option_flag (bit 7) is “0”, the transponder returns only the data in the specified blocks to the reader/writer.
The value of the “number of blocks” field specified in the request is the expected number of blocks minus 1.
Setting the number of blocks to “06H” makes a request to read 7 blocks. Up to “FFH” blocks can be set. (Note
that the maximum number of blocks is changed by setting the leading block number.)
• Request
[Request from the reader/writer to the transponder]
Number
UID
IC manufacturer
Command
First block
of
(Addressed
code
SOF Flag (Fast Read Multiple
number
blocks
mode)
(necessary)
Blocks Unlimited)
8 bits
38
8 bits (“D5H”)
8 bits (“08H”)
64 bits
8 bits
8 bits
CRC
EOF
16 bits
DS411-00001-4v1-E
MB89R118C
• Response
[Response from the transponder to the reader/writer]
(1) When Error_flag set
SOF
(2) When Error_flag not set
SOF
Flag
Flag
Error code
CRC
8 bits (“01H”)
8 bits
16 bits
EOF
Block security status (option)
Data
CRC
8 bits
64 bits
16 bits
8 bits (“00H”)
EOF
Repeated as required
4. Command Execution Time
4-1. Write Multiple Blocks Command Execution Time
The minimum time (processing in the Addressed mode) required to complete data writing to all user areas
(2000 bytes) of the FRAM and verification with the Write Multiple Blocks command is estimated to be 1.4
seconds.
4-2. Read Multiple Blocks Command Execution Time
The minimum time (processing in the Addressed mode) required to complete data reading for all user areas
(2000 bytes) of the FRAM with the Read Multiple Blocks command is estimated to be 1.5 seconds.
In addition, with the Fast Read Multiple Blocks command is estimated to be 1.1 seconds, and with the Fast
Read Multiple Blocks Unlimited command is estimated to be 0.35 seconds.
DS411-00001-4v1-E
39
MB89R118C
■ STATE TRANSITION DIAGRAM
• Definition of states
Each state of MB89R118C is defined as follows.
• Power-off state
: In the power-off state, a transponder cannot fulfill the function so that the voltage
from a reader/writer is underpowered.
• Ready state
: In the ready state, the MB89R118C can execute all commands if the Select_flag is
not set.
• Quiet state
: In the quiet state, the MB89R118C can execute the command for which the
Inventory_flag is not set and the Address_flag is set.
• Select state
: In the select state, the MB89R118C can execute the command for which the
Select_flag is set.
As shown in figure below, the MB89R118C moves from one state to another according to the status of power
and by a command.
• State transition diagram
Out of field
Power-off state
Out of field
Out of field
In field
Any other command
where Select_flag is not
set.
Ready state
Reset to Ready command
Reset to Ready command where
Select_flag is set or Select (different UID).
Select command (UID)
Stay Quiet command (UID)
Select command (UID)
Select state
Quiet state
Stay Quiet command (UID)
Any other command
where Address_flag is set
and where Inventory_flag
is not set.
40
Any other command
where Select_flag is set.
DS411-00001-4v1-E
MB89R118C
■ ABSOLUTE MAXIMUM RATINGS
Parameter
Ratings
Symbol
Unit
Remarks
Min
Max
Imax
⎯
90
mAp−p
IRF
⎯
30
mArms
Antenna connected.
ESD voltage immunity
|VESD|
⎯
2
kV
Human body model
Storage temperature
Tstg
− 55
+ 125
°C
Maximum antenna input current
Input current
WARNING: Semiconductor devices may be permanently damaged by application of stress (including, without
limitation, voltage, current or temperature) in excess of absolute maximum ratings.
Do not exceed any of these ratings.
■ RECOMMENDED OPERATING CONDITIONS
Parameter
Symbol
Minimum antenna input voltage
Value
Unit
Remarks
10.2
Vp-p
Antenna connected.
⎯
30
%
Antenna connected.
95
⎯
100
%
Antenna connected.
t1
6.0
⎯
9.44
μs
Antenna connected.
t2
3.0
⎯
t1
μs
Antenna connected.
t3
0
⎯
4.5
μs
Antenna connected.
t1
6.0
⎯
9.44
μs
Antenna connected.
t2
2.1
⎯
t1
μs
Antenna connected.
t3
1.0
⎯
4.5
μs
Antenna connected.
t4
0
⎯
0.8
μs
Antenna connected.
Input frequency
Fin
13.553
13.560
13.567
MHz
Antenna connected.
Operating temperature
Ta
− 20
⎯
+ 85
°C
Min
Typ
Max
VRF
⎯
7.5
ASK modulation index (10%)
m
10
ASK modulation index (100%)
m
ASK pulse width (10%)
ASK pulse width (100%)
WARNING: The recommended operating conditions are required in order to ensure the normal operation of
the semiconductor device. All of the device's electrical characteristics are warranted when the
device is operated under these conditions.
Any use of semiconductor devices will be under their recommended operating condition.
Operation under any conditions other than these conditions may adversely affect reliability of
device and could result in device failure.
No warranty is made with respect to any use, operating conditions or combinations not represented
on this data sheet. If you are considering application under any conditions other than listed herein,
please contact sales representatives beforehand.
However, because the communication characteristics is deeply related with the combination of
antenna, reader/writer, and operating environment, this condition does not ensure the complete
operation of transponders. Therefore it is recommended to confirm the communication characteristics with the actual antenna and reader/writer beforehand.
The values are confirmed with a reference antenna in the input capacitance 24 pF products and
its parameters are as follows.
External size
: 75 mm × 46 mm
Number of turns
:6
Width of conductor
: 1 mm
Space between 2 conductors : 0.4 mm
DS411-00001-4v1-E
41
MB89R118C
■ ELECTRICAL CHARACTERISTICS
DC characteristics
Parameter
Symbol
Load modulation resistance
Input capacitance*
24pF
96pF
RlSW
Cant
Value
Min
Typ
Max
⎯
1.1
⎯
22.8
24.0
25.2
86.4
96.0
105.6
Unit
Remarks
kΩ
pF
Voltage between
antennas = 2 Vrms
* : The capacitance value is an alternative value, which is distinguished with the part number. The values are
controlled by PCM (Process Control Monitor) in the wafer.
42
DS411-00001-4v1-E
MB89R118C
■ USAGE NOTES
• Notes on the radio interface
- The performance of transponder is determined by not only LSI specification but also antenna design and
reader/writer characteristics. Therefor it is recommended for the customers to optimize the antenna and
reader/writer according to the required communication distance and usage environment.
- If the user intends to access multiple transponders from a reader/writer, the interference between
transponders or between the reader/writer and a transponder may degrade communication performance
(transmission distance and communication time) . Therefore, a user who intends to design a system using
multiple transponders should consider this point.
• FRAM Characteristics
Item
Read/Write Endurance*1
Data Retention*2
Value
Min
Max
1012
⎯
10
⎯
30
⎯
Unit
Parameter
Times/byte Operation Ambient Temperature TA = + 85 °C
Years
Operation Ambient Temperature TA = + 85 °C
Operation Ambient Temperature TA = + 70 °C*3
*1 : Total number of reading and writing defines the minimum value of endurance, as an FRAM memory operates
with destructive readout mechanism.
*2 : Minimum values define retention time of the first reading/writing data right after shipment.
*3 : This value is calculated by reliability test results for reference as well.
• Differences of the function between ISO/IEC15693 and MB89R118C.
The comparison of the function between ISO/IEC 15693 and MB89R118C is shown in the table below.
MB89R118C does not support the following functions.
• 1 out of 256 data coding
• 2-subcarrier
The Read/Write Multiple Blocks command supports up to 2 blocks read/write. It does not support 3 or more
blocks read/write.
(A custom command “Read Multiple Blocks Unlimited command” enables to read 3 or more blocks.)
DS411-00001-4v1-E
43
MB89R118C
• MB89R118C functions compared with ISO/IEC15693
Parameter
ISO/IEC15693 specification
10% ASK
Support
100% ASK
Support
1 out of 256
Not support
1 out of 4
Support
1-subcarrier
Support
2-subcarrier
Not support
Inventory command
Support
Stay Quiet command
Support
Read Single Block command
Support
Write Single Block command
Support
Lock Block command
Support
Read Multiple Blocks command
Support up to 2 blocks
Write Multiple Blocks command
Support up to 2 blocks
Select command
Support
Reset to Ready command
Support
Write AFI command
Support
Lock AFI command
Support
Write DSFID command
Support
Lock DSFID command
Support
Get System Information command
Support
Get Multiple Block Security Status command
Support
Modulation
Data coding
Subcarrier
Mandatory command
Optional command
MB89R118C
■ RECOMMENDED ASSEMBLY CONDITIONS (WAFER)
The MB89R118C is recommended to be mounted in the following condition to maintain the data retention
characteristics of the FRAM memory when the chip is mounted.
- Mounting temperature of + 175 °C or lower, and 120 minutes or shorter when applied at high temperature, or
- Mounting temperature of + 200 °C or lower, and 60 seconds or shorter when applied at high temperature
Temperature [ °C]
Temperature [ °C]
+200
+175
+25
+25
44
120
60
Time [min]
Time [s]
DS411-00001-4v1-E
MB89R118C
■ ORDERING INFORMATION
Part number
MB89R118C1-DIAP15
MB89R118C1-DIAP15-P1
MB89R118C2-DIAP15
MB89R118C2-DIAP15-P1
DS411-00001-4v1-E
Input
capacitance
24pF
96pF
Shipping method
Marking of
Failed Chips
Wafer map
Wafer (After dicing) with Frame
Au Plating Bump
Wafer thickness: 150 μm ± 25.4 μm
Bad mark
Wafer map
Bad mark
45
MB89R118C
■ MAJOR CHANGES IN THIS EDITION
A change on a page is indicated by a vertical line drawn on the left side of that page.
Page
Section
Change Results
■ FEATURES
Revised the Data retention.
10 years ( + 85 °C)
→ 10 years ( + 85 °C) , 30 years ( + 70 °C)
• Types of AFI
Revised and corrected the table.
1
6
• Setting of Bit 5 to Bit 8 (When Inven- Revised the Nb_slots_flag.
tory command is selected [Inventory_flag = “1”])
13
40
• Setting of Bit 5 to Bit 8 (When the
command other than Inventory command is selected [Inventory_flag =
“0”])
Revised Select_flag.
0: Request shall be executed according to the setting of
Address_flag.
1: Select mode (Request shall be executed only by the
transponder in select state.)
The Address_flag shall be set to “0”.
■ STATE TRANSITION DIAGRAM
Revised Select state.
Any other command where Select_flag is set.
■ ABSOLUTE MAXIMUM RATINGS Revised the Symbol to absolute figure and value for VESD.
VESD : (Min) ± 2,(Max) “⎯” → |VESD| : (Min) “⎯” , (Max) 2
Revised the “Tstg”.
− 40 °C → − 55 °C
41
46
■ RECOMMENDED OPERATING
CONDITIONS
Revised the “Minimum antenna input voltage”.
(Typ) 6.2, (Max) 6.5 → (Typ) 7.5, (Max) 10.2
43
■ USAGE NOTES
• FRAM Characteristics
Revised the description.
45
■ ORDERING INFORMATION
Revised the table.
DS411-00001-4v1-E
MB89R118C
MEMO
DS411-00001-4v1-E
47
MB89R118C
FUJITSU SEMICONDUCTOR LIMITED
Shin-Yokohama Chuo Building, 2-100-45 Shin-Yokohama,
Kohoku-ku, Yokohama, Kanagawa 222-0033, Japan
http://jp.fujitsu.com/fsl/en/
All Rights Reserved.
FUJITSU SEMICONDUCTOR LIMITED, its subsidiaries and affiliates (collectively, "FUJITSU SEMICONDUCTOR") reserves
the right to make changes to the information contained in this document without notice. Please contact your FUJITSU
SEMICONDUCTOR sales representatives before order of FUJITSU SEMICONDUCTOR device.
Information contained in this document, such as descriptions of function and application circuit examples is presented solely for
reference to examples of operations and uses of FUJITSU SEMICONDUCTOR device. FUJITSU SEMICONDUCTOR disclaims
any and all warranties of any kind, whether express or implied, related to such information, including, without limitation, quality,
accuracy, performance, proper operation of the device or non-infringement. If you develop equipment or product incorporating the
FUJITSU SEMICONDUCTOR device based on such information, you must assume any responsibility or liability arising out of or
in connection with such information or any use thereof. FUJITSU SEMICONDUCTOR assumes no responsibility or liability for any
damages whatsoever arising out of or in connection with such information or any use thereof.
Nothing contained in this document shall be construed as granting or conferring any right under any patents, copyrights, or any other
intellectual property rights of FUJITSU SEMICONDUCTOR or any third party by license or otherwise, express or implied.
FUJITSU SEMICONDUCTOR assumes no responsibility or liability for any infringement of any intellectual property rights or other
rights of third parties resulting from or in connection with the information contained herein or use thereof.
The products described in this document are designed, developed and manufactured as contemplated for general use including
without limitation, ordinary industrial use, general office use, personal use, and household use, but are not designed, developed and
manufactured as contemplated (1) for use accompanying fatal risks or dangers that, unless extremely high levels of safety is secured,
could lead directly to death, personal injury, severe physical damage or other loss (including, without limitation, use in nuclear
facility, aircraft flight control system, air traffic control system, mass transport control system, medical life support system and
military application), or (2) for use requiring extremely high level of reliability (including, without limitation, submersible repeater
and artificial satellite). FUJITSU SEMICONDUCTOR shall not be liable for you and/or any third party for any claims or damages
arising out of or in connection with above-mentioned uses of the products.
Any semiconductor devices fail or malfunction with some probability. You are responsible for providing adequate designs and
safeguards against injury, damage or loss from such failures or malfunctions, by incorporating safety design measures into your
facility, equipments and products such as redundancy, fire protection, and prevention of overcurrent levels and other abnormal
operating conditions.
The products and technical information described in this document are subject to the Foreign Exchange and Foreign Trade Control
Law of Japan, and may be subject to export or import laws or regulations in U.S. or other countries. You are responsible for ensuring
compliance with such laws and regulations relating to export or re-export of the products and technical information described herein.
All company names, brand names and trademarks herein are property of their respective owners.
Edited: System Memory Business Division