3K Series brochure

CAN-bus Keypads for
Off-Highway Vehicles
• Five standard keypad form factors available
• J1939 and CANopen versions
• Dimmable LED indicators and legends
• Sealed to IP67
• Vibration and impact resistant
• Operating temp: -40oC to +85oC
• Long life: 1,000,000 cycles per key
• Support for multiple key press combinations
• Designed for 12/24 volt systems
• Custom legends and configurations available
3K SERIES KEYPADS
CUSTOM OPTIONS
Contact Grayhill to build your
custom part number
• Custom keytop legends
• Up to 3 LED indicators per key
• Indicator colors:
Red, Amber, Green, Blue
• Custom backlight colors:
Red, Amber, Green
• Factory configured parameters
Your Experts in Cab Controls
Grayhill specializes in the design, development and production
of human interface controls, including:
- Cab user interface design
Keypads
- CAN-bus
Customized
control panels
- CAN-bus interface devices
www.grayhill.com
DIMENSIONS in inches (and millimeters)
ISO Symbols shown in dimensional drawings
4 x 5 Keypad
3 x 5 Keypad
Panel cut-out
geometry for 4x5
and 3x5 keypads.
MOUNTING INFO
Use M6 Nut (1mm pitch)
Max Torque 25 in-lbs
STANDARD LEGEND SETS
CONNECTION
4 pin Deutsch DT Connector.
Power with 8V to 32V vehicle type inputs.
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois
Pin 4: CAN L
Pin 1: Power
Pin 3: CAN H
Pin 2: Ground
60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
DIMENSIONS in inches (and millimeters)
Panel cut-out
geometry for
4x3 keypad.
4 x 3 Keypad
4 x 2 Keypad
Panel cut-out
geometry for
4x2 keypad.
2 x 4 Keypad
Panel cut-out
geometry for
2x4 keypad.
Panel cut-out
geometry for
2x3 keypad.
2 x 3 Keypad
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois
60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
ENVIRONMENTAL TESTING STANDARDS
PHYSICAL TESTING STANDARDS
Operating temperature, High
ANSI/ASAE EP455 5.1.1
Level 2
+85°C for 11 hours
Vibration, Random
ANSI/ASAE EP455 5.15.1
2 hours each axis @ 52.4 m/s2
RMS overall acceleration and
spectral power density of 2m2/s3
from 50Hz to 2000Hz
Operating temperature, Low
ANSI/ASAE EP455 5.1.1
Level 2
-40°C for 4 hours
Storage Temperature, High
ANSI/ASAE EP455 5.1.2
Level 2
+85°C 4 hours
Vibration, Sinusoidal
ANSI/ASAE EP455 5.15.2
A logarithmic sweep from 10Hz to
2000Hz to 10Hz over a period of
20 minutes for 4 hours in each of
3 orthogonal axes with amplitude
of 1.5mm from 10Hz to 40Hz and
a constant acceleration of 35m/s2
RMS from 40Hz to 2000Hz.
Storage Temperature, Low
ANSI/ASAE EP455 5.1.2
Level 2
-40°C 4 hours
Thermal Shock
ANSI/ASAE EP455 5.1.3
-40°C to 70°C at a rate of 4°C/
min (1 hour at extremes)
Altitude (Barometric Pressure)
ANSI/ASAE EP455 5.2
101.3kPa to 18.6kPa
Shock / Crash Safety
ANSI/ASAE EP455 5.14
A single 11ms half sine pulse of
490 m/s2 in 3 perpendicular axes.
Sand and Dust
ANSI/ASAE EP455 5.3
Solar Radiation
ANSI/ASAE EP455 5.4
24 hours with 0.88g/m3
Drop
43 to 75W/m2 UV Radiation
(280 to 400nm wavelength)
for 300h
ANSI/ASAE EP455 5.14.2
Level 1
Drop component 400 mm onto a
hardwood benchtop on all practical edges.
Shipping integrity
International Safe Transit
Agency procedure 3A
Wash Down
ANSI/ASAE EP455 5.6 Level 2
375 kPa and 8.3 L/min for 10
minutes @15°C Water temp
Ingress Protection
IP67
1 meter submersion for 30
minutes
Humidity
ANSI/ASAE EP455 5.13
96% Humidity at 35°C for 240
hours.
Salt Fog
ANSI/ASAE EP455 5.9
5% aqueous solution of NaCl
@ 35°C and a pH between 6.5
and 7.2 for 48 hours
Chemical resistance (Resistance to Solvents)
Thermal Cycling (Change of
Temperature)
ISO 16750-5 EP 455 (5.8.2)
ISO 16750-4
-40° to 85°C 2 hours at extremes change rate = 1°C/min
(8 hours) repeat for 30 cycles.
ELECTROMAGNETIC COMPATIBILITY STANDARDS
ESD
ANSI/ASAE EP455 5.12
+/- 25kV for 10 pulses, 5 of
each polarity
Radiated Immunity
ISO14982 6.6
10MHz-1000MHz Range 48mA
Bulk Current Injection 100V/m
Conducted Emissions
SAE J1113-41,
Control/Signal lines only
Class 3 for 3K120-4RC3AG,
3K108-2RC3AG.
Class 4 for 3K115-3RC3AG,
3K112-4RC3AG,
3K108-4RC3AG
ISO14982 6.4
64dB to 54dB, 30MHz-75MHz
(linearly decreases) 54dB to
65dB, 75MHz-400MHz (linearly
increases) 65dB, 400MHz1000MHz
Broadband Radiated Emissions
ORDERING INFORMATION
Series Code
0 = Blank
1 = ISO Symbols (as shown above)
2 = Targets (6 and 8-key)
Key Quantity
08 (2 or 4 row), 12 (4 row),
15 (3 row), 20 (4 row)
06 (2 row)
www.grayhill.com
Maximum load
ANSI/ASAE EP455 5.1.1
Level 2
-40°C 4 hours +85°C for 11 hours
max load applied
Jump start forward voltage
ISO 16750-2
36V for 60 minutes
Jump start reverse voltage
ISO 16750-2
-36V for 60 minutes
Short circuit protection
ISO 16750-2
All outputs to ground for 60s
Reverse polarity protection
ISO 16750-2
28V for 60s
Starting profile
ISO 16750-2
12V class B, 24V class A
Battery-less operation
ANSI/ASAE EP455 5.11.3
Level 2
Apply 6+12.6sin(2*pi*f*t) f is
swept from 500Hz to 1.5kHz 5min
Load dump
ISO 7637-2 Test Pulse 5b
Class A
Switching spikes – negative
ISO 7637-2 Test Pulse 3a
Class A
Switching spikes – positive
ISO 7637-2 Test Pulse 3b
Class A
Wire harness inductance
ISO 7637-2 Test Pulse 2a
and 2b
Class A
+/- inductive load pulse
ANSI/ASAE EP455 5.11.4
14-300e^(-t/.001)V 1Hz for 300
cycles
+/- mutual coupling
ANSI/ASAE EP455 5.11.6
Level 2
14+200e^(-t/14x10^-6)V 1Hz for
300 cycles
Alternator field decay
ANSI/ASAE EP455 5.11.2
Class A
CE COMPLIANCE
Agriculture and Forestry
Machinery EMC
ISO 14982
ESA
Construction Machinery EMC
EN 13309:2000
ESA
CUSTOMIZATION OPTIONS
3K X X X - X R C 3 A G
Keypad Symbols
ELECTRICAL PERFORMANCE STANDARDS
Default
Comm Protocol
C = J1939
N = CANopen
Key Material
R = Rubber
Rows:
2, 3, 4
Contact Grayhill to build your custom part number
• Custom keytop legends
• Up to 3 LED indicators per key
• Indicator colors: Red, Amber, Green, Blue
• Custom backlight colors: Red, Amber, Green
• Factory configured parameters
Bulletin 1123