CAN-bus Keypads for Off-Highway Vehicles • Five standard keypad form factors available • J1939 and CANopen versions • Dimmable LED indicators and legends • Sealed to IP67 • Vibration and impact resistant • Operating temp: -40oC to +85oC • Long life: 1,000,000 cycles per key • Support for multiple key press combinations • Designed for 12/24 volt systems • Custom legends and configurations available 3K SERIES KEYPADS CUSTOM OPTIONS Contact Grayhill to build your custom part number • Custom keytop legends • Up to 3 LED indicators per key • Indicator colors: Red, Amber, Green, Blue • Custom backlight colors: Red, Amber, Green • Factory configured parameters Your Experts in Cab Controls Grayhill specializes in the design, development and production of human interface controls, including: - Cab user interface design Keypads - CAN-bus Customized control panels - CAN-bus interface devices www.grayhill.com DIMENSIONS in inches (and millimeters) ISO Symbols shown in dimensional drawings 4 x 5 Keypad 3 x 5 Keypad Panel cut-out geometry for 4x5 and 3x5 keypads. MOUNTING INFO Use M6 Nut (1mm pitch) Max Torque 25 in-lbs STANDARD LEGEND SETS CONNECTION 4 pin Deutsch DT Connector. Power with 8V to 32V vehicle type inputs. Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois Pin 4: CAN L Pin 1: Power Pin 3: CAN H Pin 2: Ground 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com DIMENSIONS in inches (and millimeters) Panel cut-out geometry for 4x3 keypad. 4 x 3 Keypad 4 x 2 Keypad Panel cut-out geometry for 4x2 keypad. 2 x 4 Keypad Panel cut-out geometry for 2x4 keypad. Panel cut-out geometry for 2x3 keypad. 2 x 3 Keypad Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com ENVIRONMENTAL TESTING STANDARDS PHYSICAL TESTING STANDARDS Operating temperature, High ANSI/ASAE EP455 5.1.1 Level 2 +85°C for 11 hours Vibration, Random ANSI/ASAE EP455 5.15.1 2 hours each axis @ 52.4 m/s2 RMS overall acceleration and spectral power density of 2m2/s3 from 50Hz to 2000Hz Operating temperature, Low ANSI/ASAE EP455 5.1.1 Level 2 -40°C for 4 hours Storage Temperature, High ANSI/ASAE EP455 5.1.2 Level 2 +85°C 4 hours Vibration, Sinusoidal ANSI/ASAE EP455 5.15.2 A logarithmic sweep from 10Hz to 2000Hz to 10Hz over a period of 20 minutes for 4 hours in each of 3 orthogonal axes with amplitude of 1.5mm from 10Hz to 40Hz and a constant acceleration of 35m/s2 RMS from 40Hz to 2000Hz. Storage Temperature, Low ANSI/ASAE EP455 5.1.2 Level 2 -40°C 4 hours Thermal Shock ANSI/ASAE EP455 5.1.3 -40°C to 70°C at a rate of 4°C/ min (1 hour at extremes) Altitude (Barometric Pressure) ANSI/ASAE EP455 5.2 101.3kPa to 18.6kPa Shock / Crash Safety ANSI/ASAE EP455 5.14 A single 11ms half sine pulse of 490 m/s2 in 3 perpendicular axes. Sand and Dust ANSI/ASAE EP455 5.3 Solar Radiation ANSI/ASAE EP455 5.4 24 hours with 0.88g/m3 Drop 43 to 75W/m2 UV Radiation (280 to 400nm wavelength) for 300h ANSI/ASAE EP455 5.14.2 Level 1 Drop component 400 mm onto a hardwood benchtop on all practical edges. Shipping integrity International Safe Transit Agency procedure 3A Wash Down ANSI/ASAE EP455 5.6 Level 2 375 kPa and 8.3 L/min for 10 minutes @15°C Water temp Ingress Protection IP67 1 meter submersion for 30 minutes Humidity ANSI/ASAE EP455 5.13 96% Humidity at 35°C for 240 hours. Salt Fog ANSI/ASAE EP455 5.9 5% aqueous solution of NaCl @ 35°C and a pH between 6.5 and 7.2 for 48 hours Chemical resistance (Resistance to Solvents) Thermal Cycling (Change of Temperature) ISO 16750-5 EP 455 (5.8.2) ISO 16750-4 -40° to 85°C 2 hours at extremes change rate = 1°C/min (8 hours) repeat for 30 cycles. ELECTROMAGNETIC COMPATIBILITY STANDARDS ESD ANSI/ASAE EP455 5.12 +/- 25kV for 10 pulses, 5 of each polarity Radiated Immunity ISO14982 6.6 10MHz-1000MHz Range 48mA Bulk Current Injection 100V/m Conducted Emissions SAE J1113-41, Control/Signal lines only Class 3 for 3K120-4RC3AG, 3K108-2RC3AG. Class 4 for 3K115-3RC3AG, 3K112-4RC3AG, 3K108-4RC3AG ISO14982 6.4 64dB to 54dB, 30MHz-75MHz (linearly decreases) 54dB to 65dB, 75MHz-400MHz (linearly increases) 65dB, 400MHz1000MHz Broadband Radiated Emissions ORDERING INFORMATION Series Code 0 = Blank 1 = ISO Symbols (as shown above) 2 = Targets (6 and 8-key) Key Quantity 08 (2 or 4 row), 12 (4 row), 15 (3 row), 20 (4 row) 06 (2 row) www.grayhill.com Maximum load ANSI/ASAE EP455 5.1.1 Level 2 -40°C 4 hours +85°C for 11 hours max load applied Jump start forward voltage ISO 16750-2 36V for 60 minutes Jump start reverse voltage ISO 16750-2 -36V for 60 minutes Short circuit protection ISO 16750-2 All outputs to ground for 60s Reverse polarity protection ISO 16750-2 28V for 60s Starting profile ISO 16750-2 12V class B, 24V class A Battery-less operation ANSI/ASAE EP455 5.11.3 Level 2 Apply 6+12.6sin(2*pi*f*t) f is swept from 500Hz to 1.5kHz 5min Load dump ISO 7637-2 Test Pulse 5b Class A Switching spikes – negative ISO 7637-2 Test Pulse 3a Class A Switching spikes – positive ISO 7637-2 Test Pulse 3b Class A Wire harness inductance ISO 7637-2 Test Pulse 2a and 2b Class A +/- inductive load pulse ANSI/ASAE EP455 5.11.4 14-300e^(-t/.001)V 1Hz for 300 cycles +/- mutual coupling ANSI/ASAE EP455 5.11.6 Level 2 14+200e^(-t/14x10^-6)V 1Hz for 300 cycles Alternator field decay ANSI/ASAE EP455 5.11.2 Class A CE COMPLIANCE Agriculture and Forestry Machinery EMC ISO 14982 ESA Construction Machinery EMC EN 13309:2000 ESA CUSTOMIZATION OPTIONS 3K X X X - X R C 3 A G Keypad Symbols ELECTRICAL PERFORMANCE STANDARDS Default Comm Protocol C = J1939 N = CANopen Key Material R = Rubber Rows: 2, 3, 4 Contact Grayhill to build your custom part number • Custom keytop legends • Up to 3 LED indicators per key • Indicator colors: Red, Amber, Green, Blue • Custom backlight colors: Red, Amber, Green • Factory configured parameters Bulletin 1123 Rev 06/14