Vehicle Display Controller Put display functions within reach - 5 hot keys for rapid navigation - Scroll with rotary encoder - Select with pushbutton - Navigate with joystick • Three Configurations - Optical Rotary Encoder - Encoder with Pushbutton - Joysticking Encoder with Pushbutton • J1939 and CANopen versions • Dimmable LED indicators and legends • Sealed to IP67 • Vibration and impact resistant • Operating Temp: -40oC to +85oC • Long Life: 500,000 cycles • Support for multiple key combinations • Designed for 12/24 volt systems • Custom legends and configurations Joysticking Encoder version Rotary Encoder version with Target Legends DIMENSIONS in inches (and millimeters) Blank keys shown below ISO Symbols shown below Your Experts in Cab Controls Recommended Panel Cut-out Esc www.grayhill.com www.grayhill.com Grayhill specializes in the design, development and production of human interface controls, including: - Cab user interface design - Customized control panels - CAN-bus interface devices ENVIRONMENTAL SPECIFICATIONS MECHANICAL PERFORMANCE Operating temperature ANSI/ASAE EP455 5.1.1 Level 2 -40°C for 4 hours to +85°C for 11 hours Storage Temperature ANSI/ASAE EP455 5.1.2 Level 2 -40°C 4 hours to +85°C 4 hours Thermal Shock ANSI/ASAE EP455 5.1.3 -40°C to 70°C at a rate of 4°C/ min (1 hour at extremes) Altitude (Barometric Pressure) ANSI/ASAE EP455 5.2 101.3kPa to 18.6kPa Sand and Dust ANSI/ASAE EP455 5.3 24 hours with 0.88g/m3 Solar Radiation ANSI/ASAE EP455 5.4 43 to 75W/m2 UV Radiation (280 to 400nm wavelength) for 300h Wash Down ANSI/ASAE EP455 5.6 Level 2 375 kPa and 8.3 L/min for 10 minutes @15°C Water temp Ingress Protection IP67 1 meter submersion for 30 minutes Humidity ANSI/ASAE EP455 5.13 96% Humidity at 35°C for 240 hours. Salt Fog ANSI/ASAE EP455 5.9 5% aqueous solution of NaCl @ 35°C and a pH between 6.5 and 7.2 for 48 hours Chemical resistance (Resistance to Solvents) ISO 16750-5 EP 455 (5.8.2) Thermal Cycling (Change of Temperature) ISO 16750-4 -40° to 85°C 2 hours at extremes change rate = 1°C/ min (8 hours) repeat for 30 cycles. ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS Vibration, Random ANSI/ASAE EP455 5.15.1 2 hours each axis @ 52.4 m/s2 RMS overall acceleration and spectral power density of 2m2/s3 from 50Hz to 2000Hz Vibration, Sinusoidal ANSI/ASAE EP455 5.15.2 A logarithmic sweep from 10Hz to 2000Hz to 10Hz over a period of 20 minutes for 4 hours in each of 3 orthogonal axes with amplitude of 1.5mm from 10Hz to 40Hz and a constant acceleration of 35m/s2 RMS from 40Hz to 2000Hz. Shock / Crash Safety ANSI/ASAE EP455 5.14 A single 11ms half sine pulse of 490 m/s2 in 3 perpendicular axes. Drop ANSI/ASAE EP455 5.14.2 Level 1 Drop component 400 mm onto a hardwood benchtop on all practical edges. Shipping integrity International Safe Transit Agency procedure 3A ELECTRICAL PERFORMANCE SPECIFICATIONS Maximum load ANSI/ASAE EP455 5.1.1 Level 2 -40°C 4 hours +85°C for 11 hours max load applied Jump start forward voltage ISO 16750-2 36V for 60 minutes Jump start reverse voltage ISO 16750-2 -36V for 60 minutes Short circuit protection ISO 16750-2 All outputs to ground for 60s Reverse polarity protection ISO 16750-2 28V for 60s Starting profile ISO 16750-2 Class A ESD ANSI/ASAE EP455 5.12 +/- 25kV for 10 pulses, 5 of each polarity Battery-less operation ANSI/ASAE EP455 5.11.3 Level 2 Apply 6+12.6sin(2*pi*f*t) f is swept from 500Hz to 1.5kHz 5min Radiated Immunity ISO14982 6.6 10MHz-1000MHz Range 48mA Bulk Current Injection 100V/m Load dump ISO 7637-2 Test Pulse 5b Class A Switching spikes – negative ISO 7637-2 Test Pulse 3a Class A Switching spikes – positive ISO 7637-2 Test Pulse 3b Class A Wire harness inductance ISO 7637-2 Test Pulse 2a and 2b Class A +/- inductive load pulse ANSI/ASAE EP455 5.11.4 14-300e^(-t/.001)V 1Hz for 300 cycles +/- mutual coupling ANSI/ASAE EP455 5.11.6 Level 2 14+200e^(-t/14x10^-6)V 1Hz for 300 cycles Alternator field decay ANSI/ASAE EP455 5.11.2 Class A Conducted Emissions SAE J1113-41 Class 3 Broadband Radiated Emissions ISO14982 6.4 64dB to 54dB, 30MHz-75MHz (linearly decreases) 54dB to 65dB, 75MHz-400MHz (linearly increases) 65dB, 400MHz1000MHz CE COMPLIANCE Agriculture and Forestry Machinery EMC ISO 14982 ESA Construction Machinery EMC EN 13309:2000 ESA ORDERING INFORMATION Series Code CONNECTION 3JXXX5-200N 4 pin Deutsch DT Connector. Power with 8V to 32V vehicle type inputs. Protocol Blank = J1939 N = CANopen Keypad Symbols 0 = Blank 1 = ISO Symbols (as shown in dimensional drawing) 2 = Targets Custom Designation 200 = Default Input Type 2 3 4 Signal Power Gnd CAN_H CAN_L 5 = Default MOUNTING INFO Center Pushbutton Use M6 Nut (1mm pitch) Max Torque 25 in-lbs 0 = No pushbutton 1 = Pushbutton (joystick always has pushbutton) Grayhill, Inc. www.grayhill.com 1 Configuration 0 = Encoder 1 = Joystick Encoder 561 Hillgrove Avenue LaGrange, Illinois 60525 Pin phone: (708) 354-1040 fax: (708) 354-2820 Custom options available Bulletin 1124 Rev 06/14 Contact Grayhill or your local Grayhill sales representative for more information.