ACUIX Analog Quick Installation Guide

ACUIX™ PTZ Dome Quick Installation Guide
Pre-installation Instructions and Warnings
!
Indoor pendant and in-ceiling: Ensure a 24 VAC @ 1.9A power source is available.
All types of installations must be performed by qualified technical personnel and must be in accordance with
all national and local mechanical and electrical codes.
!
Outdoor pendant and rugged: Ensure a 24 VAC @ 2.5 A power source is available.
These instructions are intended as a basic guide. It is recommended that you refer to the ACUIX
User Guide for details not included due to space limitations.
Ensure the mounting surface and installation hardware can hold the combined weight of the camera scan,
housing and mount. All mounting hardware must have a minimum pullout strength of 600 lb (272 kg) per
bolt.
Not all models or options shown. The step order may also vary depending on the type of
installation.
To prevent damage to the interface board, follow standard industry precautions for electrostatic discharge
sensitive devices.
Step
Properly seal all joints, bolts and screws to prevent moisture from entering the outdoor or rugged
housing, or if an indoor model is installed in a wet environment or subject to exposure to moisture.
1
Set the Housing Interface Board Switches
A
Housing Interface Board
U3
Set the RS485 termination and video selection switches.
Each RS-485 port on the HDCC8TP must be treated individually as
if each one is on a separate piece of equipment.
A
Function
SW1 = away from ON
RS-485 data not terminated (default)
SW1 = toward ON
RS-485 data terminated in 120 Ohms
75 Ohm coax video operation (default);
UTP video balun is disabled
120 Ohm UTP video operation; UTP
video balun is enabled
SW2 = toward ON
C
BNC connector
J3
J6
(RS-485)
2
If required for rugged dome installations, secure an installer
supplied safety cable to a building support. A 3/32” (2.5 mm) plastic
coated aircraft cable is recommended.
4
Step
Refer to
SW1
Set Camera Circuit Board DIP Switches
B
MAXPRO-mode
IntelliBus™
Diamond
VCL - RS485
VCL Video Telemetry
(Control over Coax)
Pelco P
Pelco D
SW6/1
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
SW5/1
SW5/2
SW5/3
SW5/4
SW5/5
SW5/6
SW5/7
SW5/8
OFF
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
SW6/2
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
SW6/3
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
SW6/4
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
Parity
None
Even
Odd
OFF
OFF
SW6/5
OFF
ON
OFF
SW6/6
OFF
OFF
ON
B
Camera Circuit Board
SW5
SW1 to SW4
camera address protocol
E
Value
Units digit
Tens digit
Hundreds digit
Thousands digit
Ceiling
mount
(HDCM1)
Pole mount adapter
(HDXPMA1)
Wall mount
(HDXWM1)
ON
For most installations, leave SW5-8 ON, otherwise users
can make changes to the address, protocol, baud rate and
parity from the OSD menu.
Install Housing
1
Install a 0.75” (19 mm) conduit fitting on the housing
2
Place the gasket between the hole and the conduit fitting. Tighten the
conduit nut and ensure water tight.
3
Route the field wiring through the hole in the side of the housing.
Secure the housing to the mounting bracket.
Corner adapter
(HDXCMA1)
D
Rugged Dome Housing
with Mounting Bracket
Mounting
bracket
Housing
(HDH00RA00)
E
Lower dome
In-Ceiling Housing*
Indoor in-ceiling
Housing (HDH00DA00)
In-ceiling (Dropped or Hard Ceiling)
1
SW6 baud
rate/parity
F
Address
SW1
SW2
SW3
SW4
Parapet and
roof mount
(HDPRM2)
Rugged
Default settings: MAXPRO-mode protocol, 9600, baud, even parity.
Protocol
Indoor and Outdoor Pendant
Mounts and Adapters
Wiring
access hole
D
Refer to
Use the hole pattern on the mount, adapter or bracket to drill holes
in the wall, ceiling or roof. Use the appropriate hardware for the
mounting surface. For rugged domes, the bracket can be at any
angle from 0° to 90° with respect to the housing; position the
housing horizontally and parallel to the floor.
J7 (UTP)
J1
(24 VAC)
2
1
SW2
J4
(alarms)
C
Pendant and Rugged Installations
D
Switch
SW2 = away from ON
Baud Rate
600
1200
2400
4800
9600
19200
38400
57600
115200
Install the Mount, Adapter or Bracket
Refer to
Refer to
Step
3
Step
Cut a 7 5/8” (194 mm) hole in ceiling. Seal perimeter to stop dust or debris
from fallling from ceiling. For dropped ceilings, remove ceiling plate and
place on dropped ceiling tile. Trim the tile and press into the plate.
2
If required, secure an installer supplied safety cable to a building support.
A 3/32” (2.5 mm) plastic coated aircraft cable is recommended.
3
Place tile (including plate for dropped ceilings) and housing on the ceiling
grid supports.
4
Insert through hole with wing tabs flat. Rotate tabs clockwise to tighten
against ceiling. Ensure the space between wing tab and housing is greater
than ceiling thickness, and wing tabs are staggered to different heights.
Indoor and Outdoor Pendant
1
Route field wiring from mount through top of housing.
To prevent the threads from binding, wrap the threaded nipple with Teflon® tape.
2
Thread housing onto mount.
In-ceiling lower dome
(smoked with black trim
shown - HDB00D0CB)
*For a dropped ceiling use the ceiling
plate included with the shipment
F
Pendant Housing and
Lower Dome
Indoor (white shown
HDH00PA00)
Outdoor
(HDH00WA00)
Pendant lower dome
(smoked with white trim
ring shown - HDB00P0SW)
Instructions continue on next page
Step
5
Connect Wiring to the Housing Interface Board
Each ACUIX requires a 24 VAC ± 10% power source when measured at the dome. Refer below for the wire gauge
required for maximum distances to maintain. The wire sizes and distances represent one 24 VAC power source for one
ACUIX.
Step
6
Refer to
Install Scan Assembly into Housing
Camera assembly installation is the same for all housing types.
Refer to
A
G
Remove the pluggable terminal strips from connectors J1 (24
VAC) and J6 (RS-485). If alarms are required, see inset G.
1
2
Loosen the screws on the terminal and insert wiring into the
correct terminal. Tighten screw.
3
Install the 24 VAC power wires, data wires, video wires (if UTP is
selected) and alarm wires to the correct positions on terminal
strips J1, J4, J6, and J7. Ensure the yellow labeled terminal strip
is plugged into the yellow labeled connector and the white
labeled terminal strip into the white labeled connector.
H
Connect incoming coaxial cable to coaxial pigtail on the housing interface board. Tighten the screw on the terminal strip to
secure the wire.
4
Plug the terminal strips into the respective connectors on the
interface board. If you are using a coaxial cable for video,
connect the field-run coaxial cable to J3.
5
Function
Terminal Strip J1
Pin 1
Pin 2
Pin 3
Terminal Strip J4
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Terminal Strip J6
Alarm 1 (A1)
Alarm Common (CM)
Alarm 2 (A2)
Alarm 3 (A3)
Alarm Common (CM)
Alarm 4 (A4)
Function
Outdoor Pendant and Rugged
24 VAC Camera + Heater and Blower (2.5A)
30 feet (9.1 meters)
22
Indoor Pendant and In-Ceiling
24 VAC Camera Only (1.9A)
39 feet (11.8 meters)
20
62 feet (18.9 meters)
47 feet (14.3 meters)
18
99 feet (30.2 meters)
75 feet (22.9 meters)
16
157 feet (47.9 meters)
120 feet (36.6 meters)
14
250 feet (76.2 meters)
190 feet (58 meters)
12
328 feet (100.0 meters)
302 feet (92 meters)
AWG
Recommended Video, Data, Power, Alarm and UTP Cabling
Type
Recommended Cable
Maximum Distance
Video
Coaxial Cable - RG59/U Connector BNC crimp on for RG59/U
1000 feet (305 meters)
Data
One shielded twisted pair, RS485
cable,can also be Cat5 or better
4000 feet (1219 meters)
Power
18 AWG 2-conductor
See gauge chart for each
unit
Alarm
Belden 8205
10,000 feet (3048 meters)
Cat5 or better; 1 twisted pair for
data, 1 twisted pair for video
1200 feet (365.7 meters)
Unshielded Twisted
Pair (UTP) Video
2
Rotate and line up the scan assembly yellow label to the
mounted housing yellow label. Gently push the scan into
the housing until the two guides lock/snap into the holes
on the housing guides.
Pin 1
Pin 2
Pin 3
Terminal Strip J7
Data + (D+)
Data – (D – )
Shield (SH)
Function
Step
Pin 1
Pin 2
Video + (V+) (UTP wiring)
Video – (V – ) (UTP wiring)
Refer to
3
Align yellow labels on
housing and scan
Housing* locking guide
with holes
Gently pull down on the assembly to ensure that it has
properly latched into place.
*Pendant housing shown
D
G
H
Camera assembly
locking guide (1 of 2)
If applicable, secure the wires from the terminal strip and BNC connector together with a wire tie to
ensure the cabling does not prevent the secure closure of the housing and lower dome. Feed extra wire
and cable up through the hole in the housing and route it so that it doesn't interfere with the pan and tilt
unit when it is inserted.
Wire Gauge Required for Maximum Distance to Dome
Remove the plastic lens cap. Do not touch the lens.
24 VAC (AC)
Earth Ground
24 VAC (AC)
Function
When connecting field wiring, connect to either J3 or J7, not to both
at the same time.
6
1
Terminal Strip Pins and Functions
7
Install the Lower Dome
Rugged
1
Clip the lanyard on the housing to the mounting post on the lower dome.
2
Align the four screw holes on the lower dome with the four holes on the housing.
3
Press the lower dome into the housing and turn the security screws using the special
hex key provided.
Alarm Input Terminal Block
E
1 Remove the plug-in terminal block on J4.
2 Connect a twisted-pair cable from each
peripheral alarm contact to each input at the
alarm number terminal and the alarm
common terminal on J4. The alarm is a dry
contact between the alarm terminal and the
common terminal.
F
In-ceiling
1
Clip the lanyard on the housing to the mounting post on the lower dome.
2
Align the lower dome tab hooks with the three mounting posts on the housing.
Twist to lock the lower dome into the housing.
Indoor and Outdoor Pendant
3 The alarms can be configured as normally
open or normally closed. The common
terminals are doubled up as shown. Refer to
the ACUIX User Manual to configure the
alarms.
Alarm 1
Alarm 2 Alarm 3
Alarm 4
1
Clip the lower dome lanyard to the housing retaining bracket clip. Confirm
o-ring is in place around the lower dome.
2
Press lower dome into the housing. Turn the screws to secure to the housing.
Honeywell Systems Group (Head Office)
2700 Blankenbaker Pkwy, Suite 150
Louisville, KY 40299
1.800.796.CCTV (2288)
www.honeywellvideo.com
800-02219 Rev B
October 2008
© 2008 Honeywell International Inc.
Lanyard
O-ring
*Pendant housing shown