XL403D - Sensors

XL403D
PRELIMINARY
[Patent Pending]
Advanced Digital Accelerometer
Built-in Analyses, Dynamic Interface, ±1 g to ±15 g
•
•
•
•
•
Built-in Analyses reduce the need for post-processing time
and equipment, plus shrink data file sizes. Simply request minimum values, maximum values, peak-to-peak, magnitude, tilt, or
threshold.
Dynamic Customer Interface - Set and query the XL403D
with SCPI-like commands such as CONFigure or MEASure.
Users may select the scan rates needed and set threshold
detection and actions as required. Employ start-up scripts and
run multiple sensors with data synchronization.
Flexible Output - Readouts at specified intervals can include
one, two or three axes plus temperature. Choose engineering
units (g, ° C), or raw ADC counts at RS232 or RS485 baud rates.
High Accuracy and Linearity over Wide Temperature
Range - Each sensor output is fully temperature compensated,
improving accuracy by minimizing variations due to temperature
and aging effects. Each axial sensor has been tested over the
-40° to + 85°C temperature range.
Built-in Calibration - Calibration data for each sensor is
maintained in the accelerometer. All data output is fully calibrated
in accordance with NIST standards.
•
Self-Test - Self-test signal and commands help verify channel
•
Rugged for Harsh Environments - The XL403D is robust
•
•
•
•
integrity and wiring connections.
and can be used in harsh environments. The unit will survive
5000 g powered or unpowered.
­Built-In Power Supply Regulation - Unregulated DC
power from +8.5 to +36 Volts is all that is required to measure
acceleration and temperature. Reverse power voltages of up
to -80 V can be withstood indefinitely. Transients of +80 V for
550 ms compatible with MIL-STD-704A can be withstood with
full operation.
Small Size - Completely conditioned triaxial accelerometer in
less than one cubic inch.
Earth Friendly Design - Lead-free design makes the
XL403D environmentally safe while Measurement Specialties’
assembly process ensures reliable functionality. Fully-potted
electronics eliminates the possibility of tin whiskers-related
failures.
Three-Year Warranty - This Measurement Specialties digital
accelerometer comes with a three-year factory warranty.
*Technical Data subject to change without notice
The XL403D is the first accelerometer to support SCPI-like commands, return data in engineering units, and
work with an ASCII terminal emulator. It also performs basic functions such as evaluating minimum, maximum,
magnitude, peak-to-peak, and tilt. The output is configurable by the customer - choose number of axes, units
returned, bandwidth, sample rates, function specifics, and analysis results.
The sensor also contains a temperature sensor, microcontroller, and analog outputs in a small, easy-to-install
package. The microcontroller takes 10-bit samples and performs temperature compensation and additional functions as programmed for output via the RS-485 interface.
Order the range option best suited for your application to measure from ±1 g to ±15 g, and set your own low
pass filter for bandwidths from 1 to 800 Hz.
XL403D Advanced Digital Accelerometer
precisionsensors.meas-spec.com 2236 N. Cleveland-Massillon Road
Akron OH 44333 PH : 330-659-3312 7/19/2013
www.meas-spec.com
Specifications for XL403D - improved specifications available upon request
TA = TMIN to TMAX; Acceleration = 0 g, unless otherwise noted; within one year of calibration.
Parameter
Min
Range - Measurement Full Scale
Typical
±1
Max
Units
Conditions/Notes
±15
g
On each axis. Must specifiy via Option Rnnn
Sensitivity
At 25°C, Option R005
Drift TMIN to TMAX
±0.65
±3
mV/g
%
Precise values on calibration certificate
Percent of sensitivity at 25°C
Zero g Bias Level
At 25°C
Drift TMIN to TMAX
2.500
10
20
V
mg
Precise values on calibration certificate
At 1.25°C/min. temperature rate of change
Alignment
Deviation from ideal axes
±1.0
±2.0
degrees
Precise values on calibration certificate
Can be compensated if required
Transverse Sensitivity
±0.25
%
Inherent sensor error, excluding misalignment
400*
Nonlinearity
0.1
Frequency Response
0
Noise Density
0.25
% FSR
Best fit straight line
Hz
Upper cutoff per Option Bnnn, -3 dB pt ±10%
5-pole Butterworth filter
µg/√Hz
10 Hz to 400 HZ
kΩ
Logic “1” ≥ 3.5 V, Logic “0” ≤ 1.5 V, “0” causes self test
±0.2
°C
Accuracy ±1 °C
2500
scans/sec
Default scan list (A1,A2,A3,T1)
800
100
Self Test Pull-up Resistor
5
Temperature Sensor
Scan Rate
0.0007
ADC Resolution
Absolute accuracy
Outputs
Output Voltage Swing
Capacitive Drive Capability
Power Supply (VS)
Input Voltage Limits
Input Voltage - Operating
Input Current
Rejection Ratio
10
±2
0.5
-80
+8.5
Temperature Range (TA)
1000
25
>120
-40
Mass
bits
LSB
4.5
V
pF
IOUT = ±0.5 mA
+80
+36
V
V
mA
dB
-80 V continuous, >38 V if ≤550 ms, duty <1%
Continuous
+85
°C
38
Shock Survival
-5000
+5000
DC
grams
Precise values on calibration certificate
g
Any axis for 0.5 ms, powered or unpowered
*Scale linearly with Range option Rnnn - see Ordering Information
Mechanical
Connections
T004
3
3
Pin
1
2
3
4
5
6
7
Signal Analog1+Analog2+Analog3+ Signal - RS485- RS485+ ST/Aux
Wire Brown
Red
Orange Yellow Green
Blue
Violet
8
+Vs
Grey
9
Gnd
White
Ordering Information
XL403D
-
X1
-
R006
-
T004
Instrument
XL403D
Axes
X1 : Uniaxial
X2 : Biaxial
X3 : Triaxial
Mounting
adapters
(sold
separately)
35173A Horizontal
XL403D Advanced Digital Accelerometer
precisionsensors.meas-spec.com 35172A Vertical
Termination Length
T004 : 4 ft. cable with DB9M
Tnnn : Custom length, nnn ft.
Range
Rnnn : Choose 001 (±1 g)
through 015 (±15 g)
Please note: PC Interface Kit is required
for digital sensor use (sold separately).
2236 N. Cleveland-Massillon Road
Akron OH 44333 PH : 330-659-3312 7/19/2013
www.meas-spec.com
XL403D Set up
Use the 35250AK0/AK1 interface kit (sold separately) to connect the XL403D to a computer with a serial port and supply power (USB adapters available if needed). Use an ASCII terminal emulator of your choice to interface with the sensor
(Tera Term Pro is recommended).
XL403D Sample Commands
Set commands
ROUT:SCAN
Query Commands
set channels to be scanned
*IDN?
device identification
ROUT:SCAN?
channels being scanned
READ?
show single scan
INP:FILT:FREQ
set cutoff frequency
INP:FILT:FREQ?
current cutoff filter setting
TRIG:SOUR:TIM
set time-based scan
TRIG:SOUR?
current trigger source
TRIG:COUNT
set maximum number of triggers
TRIG:COUNT?
current max number of triggers
INIT
begin scanning as configured
SYST:ERR?
current error status
OUT:FMT
format output
OUT:FMT?
current formatting
CONF:FNC <name>
configure function
CONF:FNC?
current function definitions
Display engineering units (FLT), HEX values; add a scan count or CRC to each scan
XL403D Functions
Configure XL403D’s built-in functions to execute as needed. Each unique function is performed on the scan measurements, with results maintained internally within the sensor.
MIN – tracks the minimum reading on each channel since the function was configured
MAX – tracks the maximum reading on each channel since the function was configured
MAG – calculates the magnitude of the vector sum of axes A1, A2 and A3
PTP – tracks the peak-to-peak value for each channel since the function was configured. This is equal to MAX – MIN for
each channel
TLT – calculates the 2-axis tilt angle for any 2 axes that are in scan
TH1 – tracks channels readings against individual channel threshold values
TH2 – tracks MAG or TLT values against a threshold
OU1/OU2/OU3 – output functions that print the values of functions on a configurable periodic basis
When the XL403D threshold function is set, external controls can be triggered when the threshold is reached. Receive a
warning, flip a switch, apply a brake - take action immediately when limits are exceeded.