180 dBc/Hz

Designed and
Manufactured
in Germany
Specification
Oscillator type:
Rev.: 3
Date: 2014-05-08
AXIOM5151
OCXO with Ultra-Low Phase Noise Floor of -180 dBc/Hz
Parameter
Frequency range
Standard frequencies
Frequency stability
Initial tolerance @ +25°C
vs. operating temperature range
vs. supply voltage variation (pushing)
Long term (aging) per day
st
Long term (aging) 1 year
Frequency adjustment range
Electronic Frequency Control (EFC)
EFC voltage VC
EFC slope (∆f / ∆VC)
EFC input impedance
RF output
Signal waveform
Load RL
Output level
Harmonics
Spurious
Warm-up time @ +25°C
G-Sensitivity
Phase Noise
Noise floor
Supply voltage VS (Note 3)
Current consumption (steady state)
Current consumption (warm-up)
Operating temperature range (Note 2)
min.
80
max.
Unit
125
100.000/120.000
MHz
MHz
±300
±200
±2
±200
ppb
ppb
ppb
ppb
ppb
10.0
ppm
V
±20
±1
0
±2
5.0
Positive
100
Condition
@ VC = 5.0 V
steady state (Note 2)
VS ±5%
after 30 days operation
after 30 days operation
kΩ
Sine wave
50
+16
+14
-40
-110
5
1.0
See table 1
11.4
-180
12.6
275
475
+60
12.0
-10
Enclosure (see drawing) (LxWxH)
Weight
Packing
Notes:
1.
2.
3.
typ.
51x51x19 max.
Ω
dBm
dBc
dBc
min
ppb/g
@ VC = 5.0 V
∆ffinal/f0 < ±0.2 ppm
per axis
Option 1
dBc/Hz @ ≥ 100 kHz
V
mA
@ +25°C
mA
°C
mm
g
85
Palette
Terminology and test conditions are according to IEC60679-1 and MIL-PRF-55310, unless otherwise stated
Other stability and temperature range on request
Other supply voltages on request
Absolute Maximum Ratings
Parameter
min.
max.
Supply Voltage VS
Control Voltage VC
Storage Temperature
-0.5
-0.5
-55
VS + 10%
15
+125
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXIOM5151 Rev.3
Drawing D0
Page 1(4)
Unit
Condition
V
V
°C
VS to GND
VC to GND
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Designed and
Manufactured
in Germany
Phase Noise – Option 1:
Offset
A
-90
-125
-155
-175
-180
10 Hz
100 Hz
1 kHz
10 kHz
≥100 kHz
Table 1
B
-95
-130
-158
-176
-180
100 MHz
C
-97
-132
-160
-176
-180
D
-100
-135
-162
-176
-180
E
-105
-137
-164
-178
-180
A
-85
-118
-148
-160
-180
B
-90
-122
-150
-165
-180
120 MHz
C
-95
-125
-153
-168
-180
D
-97
-127
-155
-171
-180
E
-100
-130
-157
-175
-180
Unit
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
Ordering Code
Option 1
Revision Frequency [MHz]
[Phase noise]
AXIOM5151
Table 1
Rev.3
100.000
Example: AXIOM5151-C_Rev.3 – 100.000 MHz
Model
Handling and Testing
Parameter
Handling and Testing
Processing
Parameter
Electrostatic discharge (ESD)
THD devices
SMD devices
Washable
RoHS- Compliant
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
Procedure
Application Note AXAN-011
Application Note AXAN-012
Procedure
IEC60749-26
IEC60749-27
Yes
Yes
AXIOM5151 Rev.3
Drawing D0
Page 2(4)
HBM
MM
No
No
Source
www.axtal.com
www.axtal.com
Condition
2000 V
200 V
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Designed and
Manufactured
in Germany
Enclosure drawing
Pin connections:
Pin # Symbol
1
VS
2
N.C.
3
GND
4
VC
SMA RF OUT
Function
Supply Voltage
No Connection
Ground
Control Voltage (EFC)
RF Output
* See Application Note AXAN-011
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXIOM5151 Rev.3
Drawing D0
Page 3(4)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Designed and
Manufactured
in Germany
Environmental conditions
Test
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC
60068
Part …
2-17
IEC
60679-1
Clause
5.6.2
MIL-STD202G
Method
112E
2-20
2-58
5.6.3
208H
210F
2-27
5.6.8
213B
Vibration,
2-6
5.6.7.1
201A
sinusoidal*
204D
Vibration,
2-64
5.6.7.3
214A
random*
Endurance tests
108A
- ageing
5.7.1
- extended aging
5.7.2
Other environmental conditions on request
MIL-STD810F
Method
MIL-PRF55310D
Clause
3.6.1.2
3.6.52
3.6.48
516.4
3.6.40
516.4-4
3.6.38.1
3.6.38.2
3.6.38.3
3.6.38.4
514.5
4.8.35
Test conditions (IEC)
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta Method 1
Test Td1 Method 2
Test Td2 Method 2
Test Ea, 3 x per axes 100g,
6 ms half-sine pulse
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g
Test Fdb
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
Data sheet is for information purposes only and may be subject to modifications or may be discontinued without notice.
Revision History
Rev.
Drawing
Date
[dd.mm.yyyy]
2
3
D1
D0
01.10.2012
08.05.2014
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
Remarks
Editorial changes
Various parameters updated, G-Sensitivity added,
environmental conditions updated, editorial changes
AXIOM5151 Rev.3
Drawing D0
Page 4(4)
Author
Checked
BN
HH
BN
HH
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]