Specification AXIS145 Oscillator type: SMD VCXO in CO27

Specification
Oscillator type:
Parameter
Frequency range
min.
Long term (aging) per year
Frequency adjustment range
Electronic Frequency Control (EFC)
EFC voltage VC
±50
±100
±150
0.15
0
Load
Amplitude
Jitter (PECL & LVDS versions only)
Supply voltage VS
Current consumption (Note 3)
Enclosure (see drawing) (LxWxH)
Weight
Packing
1.65
2.5
Positive
Negative
Date: 2014-04-05
max.
Unit
Condition
50
800
MHz
MHz
ppm
ppm
ppm
Sine wave
HCMOS, PECL, LVDS
±10 to ±100
See tables 1 & 2
EFC slope (∆f / ∆VC)
EFC input impedance
RF output
Signal waveform
typ.
10
1
Frequency stability
Overall stability
vs. operating temperature range
Notes:
1.
2.
3.
4.
Rev.: 2
AXIS145
SMD VCXO in CO27 package
±3
ppm
3.15
5
ppm
ppm
ppm
V
V
100
Option 3 & 4
Option 5 = “5”
Option 5 = “10”
Option 5 = “15”
Option 1 = “3”
Option 1 = “5”
Option 6 = blank
Option 6 = “N” (Note 2)
kΩ
Sine wave
HCMOS
PECL
LVDS
50 Ω
15 pF
50 Ω + Bias
0
dBm
+10
dBm
According to relevant Logic Standard
1.0
ps
3.15
3.3
3.45
V
4.75
5.0
5.25
V
15 ~ 70
mA
15 ~ 100
mA
25 ~ 100
mA
14.4x9.5x6.0 max.
2
Tape & Reel
mm
g
Option 2 = “S”
Option 2 = “H”
Option 2 = “P”
Option 2 = “L”
Option 2 = “S”
Option 2 = “H”
Option 2 = “P” or “L”
Option 2 = “S” / 3.3 V
Option 2 = “S” / 5.0 V
Option 2 = “H”, “P”, “L”
12 kHz ~20 MHz
Option 1 = “3”
Option 1 = “5”
Option 2 = “S”
Option 2 = “H”
Option 2 = “P”, “L”
IEC 61837 CO 27
IEC 60286-3
Terminology and test conditions are according to IEC60679-1 and MIL-PRF-55310, unless otherwise stated
Negative slope only available for HCMOS Output version (Option 2 = “H”)
Depending on frequency and supply voltage
All combinations of options might not be available. Please consult factory
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXIS145 Rev.2
Drawing D2
Page 1(4)
ww.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Absolute Maximum Ratings
Parameter
min.
max.
Supply Voltage VS
Control Voltage VC
Storage Temperature
-0.5
-0.5
-45
VS + 10%
6
+90
Unit
Condition
V
V
°C
VS to GND
VC to GND
Frequency stability vs. temperature
Option 3
10
15
20
30
50
100
Table 1
Stability
[ppm]
±10
±15
±20
±30
±50
±100
Lower Temperature
Option 4
T [°C]
0
0
1
-10
2
-20
3
-30
4
-40
Upper Temperature
Option 4
T [°C]
A
+50
B
+60
C
+70
D
+75
E
+80
F
+85
Ordering Code
Model
AXIS145
Option 1
[Supply
Voltage]
3 or 5
Option 2
[RF output]
Option 3
[Stability]
S, H, P, L
Table 1
Option 4
[Temperature
range]
Table 2
Option 5
Option 6
Revision
Frequency [MHz]
[Tuning Range]
[Tuning slope]
5, 10, 15
_ or “N”
Rev.2
10.000
Example: AXIS145-5-S-10-1B-N_Rev.2 – 10.000 MHz
Handling and Testing
Parameter
Procedure
Handling and Testing
Processing
Parameter
Application Note AXAN-011
Application Note AXAN-012
Procedure
Electrostatic discharge (ESD)
THD devices
SMD devices
Washable
RoHS compliant
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
IEC60749-26
IEC60749-27
Yes
Yes
AXIS145 Rev.2
Drawing D2
Page 2(4)
HBM
MM
No
No
Source
www.axtal.com
www.axtal.com
Condition
2000 V
200 V
ww.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Enclosure drawing
Pin connections
Sine wave and HCMOS Output:
Pin #
1
2
3
4
5
6
Symbol
VC
N.C.
GND
RF OUT
N.C.
Vs
Function
Voltage Control (EFC)
No Connection
Ground
RF Output
No Connection
Supply Voltage
PECL and LVDS Output:
Pin #
1
2
3
4
5
6
Symbol
VC
N.C.
GND
RF OUT
Comp OUT
Vs
Function
Voltage Control (EFC)
No Connection
Ground
RF Output
Complementary RF Output
Supply Voltage
Environmental conditions
Test
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC
60068
Part …
2-17
IEC
60679-1
Clause
5.6.2
MIL-STD202G
Method
112E
2-20
2-58
5.6.3
208H
210F
2-27
5.6.8
213B
Vibration,
2-6
5.6.7.1
201A
sinusoidal*
204D
Vibration,
2-64
5.6.7.3
214A
random*
Endurance tests
108A
- ageing
5.7.1
- extended aging
5.7.2
Other environmental conditions on request
MIL-STD810F
Method
MIL-PRF55310D
Clause
3.6.1.2
3.6.52
3.6.48
516.4
3.6.40
516.4-4
3.6.38.1
3.6.38.2
3.6.38.3
3.6.38.4
514.5
4.8.35
Test conditions (IEC)
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta Method 1
Test Td1 Method 2
Test Td2 Method 2
Test Ea, 3 x per axes 100g,
6 ms half-sine pulse
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g
Test Fdb
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
Data sheet is for information purposes only and may be subject to modifications or may be discontinued without notice.
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXIS145 Rev.2
Drawing D2
Page 3(4)
ww.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Revision History
Rev.
Drawing
Date
[dd.mm.yyyy]
2
2
D1
D2
12.10.2009
05.04.2014
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
Remarks
Editorial changes
Environmental conditions updated, editorial changes
AXIS145 Rev.2
Drawing D2
Page 4(4)
Author
Checked
BN
HH
BN
HH
ww.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]