Designed and Manufactured in Germany Specification Oscillator type: Rev.: 4 Date: 2014-04-18 AXIOM90 OCXO with Sine Wave Output and SMA Connector Parameter Frequency range Standard frequencies Frequency stability Initial tolerance @ +25°C vs. operating temperature range vs. supply voltage variation (pushing) vs. load change (pulling) Long term (aging) per day (after 30 days operation) (Note 2) st Long term (aging) 1 year (after 30 days operation) (Note 2) Frequency adjustment range Electronic Frequency Control (EFC) EFC voltage VC EFC slope (∆f / ∆VC) EFC input impedance RF output Signal waveform Load RL Output level (Note 3) Harmonics Spurious Warm-up time @ +25°C Phase Noise Supply voltage VS Current consumption (steady state) @ +25°C (Note 4) Current consumption (warm-up) (Note 4) Enclosure (see drawing) (LxWxH) Weight Packing Notes: 1. 2. 3. 4. min. typ. max. 10 40 10.000/20.000/30.000 Unit MHz MHz ±300 ppb VC @ centre value steady state ±10 ±10 ±10 ±2 ±500 ±200 ppb ppb ppb ppb ppb ppb VS ±5% RL ±10% AT-Cut SC-Cut AT-Cut SC-Cut ±5 ppm ppm V V AT-Cut SC-Cut Option 1 = “33” Option 1 = “50”, “12” Option 2 & 3 See tables 1 & 2 ±300 ±50 ±2 ±0.8 0.15 0.25 1.65 2.50 Positive 3.15 4.75 100 kΩ Sine wave 50 +3 3.15 4.75 11.4 Condition -30 -90 3 5 Consult factory 3.3 3.45 5.0 5.25 12.0 12.6 350 250 150 900 600 350 54.0x40.5x19.0 max. 60 Palette Ω dBm dBc dBc min ±10% V V V mA mA mA mA mA mA Option 1 = “33” Option 1 = “50” Option 1 = “12” Option 1 = “33” Option 1 = “50” Option 1 = “12” Option 1 = “33” Option 1 = “50” Option 1 = “12” mm g h = 2.0 mm ∆ffinal/f0 < ±0.1 ppm Terminology and test conditions are according to IEC60679-1 and MIL-PRF-55310, unless otherwise stated Lower aging on request Other output level on request May be higher for wide operating temperature range GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXIOM90 Rev.4 Drawing D0 Page 1(4) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Absolute Maximum Ratings Parameter min. max. Supply Voltage VS Control Voltage VC Storage Temperature -0.5 -0.5 -55 VS + 10% 15 +125 Unit Condition V V °C VS to GND VC to GND Frequency stability vs. temperature Option 2 05 10 25 50 100 200 Table 1 Stability [ppb] ±5 ±10 ±25 ±50 ±100 ±200 Lower Temperature Option 3 T [°C] 0 0 1 -10 2 -20 3 -30 4 -40 5 -55 Table 2 Upper Temperature Option 3 T [°C] A +50 B +60 C +70 D +75 E +80 F +85 Standard: “1B” = -10°C to +60°C Temperature Frequency stability [Option 2] range [°C] 05 10 25 50 100 200 0 ~ +50 SC SC SC AT AT AT -10 ~ +60 SC SC SC AT AT AT -20 ~ +70 O SC SC SC AT AT -30 ~ +70 O O SC SC SC AT -40 ~ +75 O O SC SC SC SC -40 ~ +85 O O O SC SC SC -55 ~ +85 O O SC SC SC Table 3 “Availability” AT, SC = AT-Cut, SC-Cut available, O = available on request, - not available Ordering Code Option 1 Option 2 Option 3 [Supply Voltage] [Stability] [Temperature range] AXIOM90 12, 33, 50 Table 1 Table 2 Example: AXIOM90-50-100-1B_Rev.4 – 30.000 MHz Model GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXIOM90 Rev.4 Drawing D0 Page 2(4) Revision Frequency [MHz] Rev.4 30.000 www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Enclosure drawing Pin connections Pin# Symbol 1 VC 2 GND 3 VS SMA RF OUT Function Control Voltage (EFC) Ground Supply Voltage RF Output * See Application Note AXAN-011 GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXIOM90 Rev.4 Drawing D0 Page 3(4) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Handling and Testing Parameter Procedure Handling and Testing Processing Source Application Note AXAN-011 Application Note AXAN-012 Parameter Procedure Electrostatic discharge (ESD) THD devices SMD devices Washable RoHS- Compliant IEC60749-26 IEC60749-27 Yes Yes www.axtal.com www.axtal.com Condition HBM MM No No 2000 V 200 V Environmental conditions Test Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* IEC 60068 Part … 2-17 IEC 60679-1 Clause 5.6.2 MIL-STD202G Method 112E 2-20 2-58 5.6.3 208H 210F 2-27 5.6.8 213B Vibration, 2-6 5.6.7.1 201A sinusoidal* 204D Vibration, 2-64 5.6.7.3 214A random* Endurance tests 108A - ageing 5.7.1 - extended aging 5.7.2 Other environmental conditions on request MIL-STD810F Method MIL-PRF55310D Clause 3.6.1.2 3.6.52 3.6.48 516.4 3.6.40 516.4-4 3.6.38.1 3.6.38.2 3.6.38.3 3.6.38.4 514.5 4.8.35 Test conditions (IEC) Gross leak: Test Qc, Fine leak: Test Qk Test Ta Method 1 Test Td1 Method 2 Test Td2 Method 2 Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Fdb 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C Data sheet is for information purposes only and may be subject to modifications or may be discontinued without notice. Revision History Rev. Drawing Date [dd.mm.yyyy] 3 4 D0 D0 14.10.2013 18.04.2014 GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany Remarks Extended ordering parameter list Various parameters updated, environmental conditions updated, editorial changes AXIOM90 Rev.4 Drawing D0 Page 4(4) Author Checked CG HH BN HH www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]